You are on page 1of 3

Drill Pipe Performance Sheet

www.NOV.com/GrantPrideco

Phone: +1 (281) 878-8000


Warning: Connection thread shear strength is too weak; the connection must be streamlined or a waiver must be signed.

Drill Pipe Configuration

Pipe Body OD
Pipe Body Wall Thickness
Pipe Body Grade
Drill Pipe Length
Connection
Tool Joint OD
Tool Joint ID
Pin Tong
Box Tong

(in)
(in)

(in)
(in)
(in)
(in)

80 % Inspection Class
Nominal Weight Designation
41.05
(ft) 31.8
Drill Pipe Approximate Length
(in) 3/32 Raised
SmoothEdge Height
(psi) 120,000
Tool Joint SMYS
Upset Type
IEU
(in) 6.000
Max Upset OD (DTE)
Friction Factor
1.0

5.875
0.750
G-105
Range2
XT57
7.250
3.500
10
15

Note: Tong space may include hardfacing.

Drill-Pipe Length

Drill Pipe Performance

Best Estimates

Performance of Drill Pipe with Pipe Body at

(without Coating)

80 % Inspection Class
Applied Make-up
Torque

Max Tension
Operational
Torque (ft-lbs)
(lbs)

(ft-lbs)

Maximum MUT

81,500

Minimum MUT

67,900

Tension Only
Combined Loading

Tension Only
Combined Loading

0
70,700

984,700
736,800

0
55,600

984,700
840,000

Drill Pipe Adjusted Weight

Fluid Displacement
Fluid Displacement
Fluid Capacity
Fluid Capacity
Drift Size

48.53
0.74
(Bbls/ft) 0.0177
(gal/ft) 0.73
(Bbls/ft) 0.0174
(in) 3.375

XT57

7.250

Applied Make-up
Tension at Shoulder
Torque
Separation
(ft-lbs)

81,500
67,900

(ft-lbs)
(lbs)

(lbs)

Tensile Limited
1,700,100

SmoothEdge Height
(in)
(lbs)

3/32 Raised
7.438
1,539,200

Assumed Elevator Bore Diameter

46.83
0.72
0.017
0.76
0.018

(lbs/ft)

0.72
0.0172

OD X

(in)

3.500

Tension at Connection
Yield
(lbs)

1,463,500
1,748,300

ID

(in)

120,000

(psi)

Tool Joint Dimensions


Balanced OD

(in)

Minimum Tool Joint OD for API


(in)
Premium Class
Minimum Tool Joint OD for
Counterbore

(in)

7.337
6.566
6.566

135,800
1,748,300

Elevator Shoulder Information


Box OD
Elevator Capacity

(least accurate)

(gal/ft)

Note: The maximum make-up torque should be applied when possible.


Note: To maximize connection operational tensile, a MUT (T4) = 69,800 (ft-lbs) should be applied.

Tool Joint Torsional Strength


Tool Joint Tensile Strength

Nominal

(with Coating)

Note: Oil field barrel equals 42 US gallons.


Note: Drill pipe assembly values are best estimates and may vary due to pipe body mill tolerance, internal plastic coating, and other factors.

Connection Performance
Maximum Make-up Torque
Minimum Make-up Torque

Range2

(in)

Elevator OD 3/32 Raised


Nominal Tool Joint
Worn to Bevel
OD
Diameter

Worn to Min TJ OD for


API Premium Class

7.250
1,301,100

6.566
483,900

Pipe Body Slip Crushing Capacity

Pipe Body Configuration

Nominal
Assumed Slip Length
Transverse Load Factor (K)

(lbs)
(in)

Pipe Body Performance

834,800

(ft-lbs)

(ft-lbs)
(psi)
(psi)
(in)
(in)
(in)
(in^2)
(in^2)
(in^2)
(in^3)
(in^3)

5.875 (in) OD

80 % Inspection Class
661,900

Pipe Body Configuration

(lbs)

0.750 (in) Wall

G-105 )

API Premium Class


661,900

Note: Slip Crushing: Slip crushing load is calculated with the Spiri-Reinhold equation from Why Does Drill Pipe
Fail in the Slip Area World Oil, 1959 for the slip length and transverse load factor shown and is for reference
only. Slip crushing is dependent on the slip design and condition, coefficient of friction, loading conditions, time in
slips, drill pipe OD and wall variation, and other factors. Consult with the slip manufacturer for additional
information.

16.5
4.2

Nominal
Pipe Tensile Strength
Pipe Torsional Strength
TJ/PipeBody Torsional Ratio
80% Pipe Torsional Strength
Burst
Collapse
Pipe OD
Wall Thickness
Nominal Pipe ID
Cross Sectional Area of Pipe Body
Cross Sectional Area of OD
Cross Sectional Area of ID
Section Modulus
Polar Section Modulus

(in)

Note: Elevator capacity based on assumed Elevator Bore, no wear factor, and contact stress of 110,100psi.
Note: A raised elevator OD increases elevator capacity without affecting make-up torque.

6.125

Slip Crushing Capacity

6.721
662,000

7.438

1,267,900
139,200
0.98
111,400
23,457
23,386
5.875
0.750
4.375
12.075
27.109
15.033
13.786
27.571

5.875 (in) OD

80 % Inspection Class
984,700
106,600
1.27
85,300
21,447
20,169
5.575
0.600
4.375
9.378
24.411
15.033
10.560
21.119

0.750 (in) Wall

G-105 )

API Premium Class


984,700
106,600
1.27
85,300
21,447
20,169
5.575
0.600
4.375
9.378
24.411
15.033
10.560
21.119

Note: Nominal Burst


calculated at 87.5% RBW
per API.

Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully
responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied
warranty is intended. Drill pipe assembly properties are calculated based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear
conditions (remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance
ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the application. For API connections that have different pin and box IDs, tool joint ID refers to
the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.

www.NOV.com/GrantPrideco/CustomerFeedback

Customer Created 02-03-2014

Operational Limits of Drill Pipe


Connection
Pipe Body

XT57
80 % Inspection Class

Tool Joint OD

(in)

7.250

Tool Joint ID

Pipe Body OD

(in)

5.875

Wall Thickness (in) 0.750

(in)

Combined Loading for Drill Pipe at

(ft-lbs)

0
3,700
7,400
11,200
14,900
18,600
22,300
26,100
29,800
33,500
37,200
41,000
44,700
48,400
52,100
55,800
59,600
63,300
67,000
70,700

(lbs)

984,700
984,100
982,300
979,200
975,000
969,600
962,900
954,700
945,400
934,800
922,800
908,900
894,000
877,400
859,100
839,100
816,500
792,400
766,000
736,800

G-105

Minimum Make-up Torque = 67,900

(ft-lbs)

Connection Max
Pipe Body
Max Tension Tension

(lbs)

Pipe Body Grade

Combined Loading for Drill Pipe at

Maximum Make-up Torque = 81,500


Operational Assembly
Torque
Max Tension

Tool Joint Specified Minimum


120,000
(psi)
Yield Strength

3.500

Operationa Assembly
l Torque
Max Tension
(ft-lbs)

(lbs)

Pipe Body
Max Tension

(lbs)

(lbs)

(ft-lbs)

Connection
Max Tension

(lbs)

984,700

984,700

1,700,100

984,700

1,463,500

984,100

1,463,500

2,900

984,300

984,300

1,700,100

1,463,500

5,900

983,100

983,100

1,700,100
1,700,100

982,300
979,200

1,463,500

8,800

981,300

981,300

975,000

1,463,500

11,700

978,700

978,700

1,700,100

969,600

1,463,500

14,600

975,400

975,400

1,700,100

962,900

1,463,500

17,600

971,100

971,100

1,700,100

1,463,500

20,500

966,300

966,300

1,700,100

1,463,500

23,400

960,600

960,600

1,700,100

1,463,500

26,300

954,200

954,200

1,700,100
1,700,100

954,700
945,400
934,800
922,800

1,463,500

29,300

946,700

946,700

908,900

1,463,500

32,200

938,700

938,700

1,700,100

894,000

1,463,500

35,100

929,800

929,800

1,700,100

877,400

1,463,500

38,100

919,600

919,600

1,700,100

1,463,500

41,000

908,900

908,900

1,700,100

1,463,500

43,900

897,300

897,300

1,700,100

884,700

884,700

1,700,100
1,700,100

859,100
839,100
816,500

46,800

1,463,500

792,400

1,463,500

49,800

870,700

870,700

766,000

1,463,500

52,700

856,000

856,000

1,700,100

736,800

1,463,500

55,600

840,000

840,000

1,700,100

Operational drilling torque is limited by the Make-up Torque.

Operational drilling torque is limited by the Make-up Torque.

Connection
Make-up Torque Range
Make-up Torque
(ft-lbs)

Min MUT

Max MUT

67,900
69,400
70,900
72,400
73,900
75,500
77,000
78,500
80,000
81,500

Connection Max
Tension

(lbs)

1,700,100
1,737,600
1,722,100
1,685,500
1,648,900
1,609,900
1,573,300
1,536,700
1,500,100
1,463,500

Note: Recommended MUT should always be used when possible. If not possible, MUT should be as close to Recommended MUT as possible.
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.

02-03-2014

Connection Wear Table


Connection

XT57

Tool Joint OD

Connection
Wear

Tool
Joint OD

New OD

(in)

7.25
7.188
7.126
7.063
7.001
6.939
6.877
6.815
6.753
6.69
6.628
6.566

Worn OD

(in)

7.250

Tool Joint ID

(in)

Tool Joint Specified Minimum


120,000
(psi)
Yield Strength

3.500

Connection Max
Tension

Connection
Torsional
Strength (ft-lbs)

Max
MUT

135,800
131,700
127,600
123,500
119,500
115,500
111,600
107,800
104,000
100,200
96,500
92,800

81,500
79,000
76,500
74,100
71,700
69,300
67,000
64,700
62,400
60,100
57,900
55,700

(ft-lbs)

Connection Max
Tension

Min MUT

(lbs)

(lbs)

(ft-lbs)

1,463,500
1,514,900
1,565,600
1,577,500
1,545,500
1,509,300
1,463,500
1,346,200
1,233,700
1,124,900
1,023,600
926,800

67,900

1,700,100

65,800

1,657,700

63,800

1,617,500

61,700

1,539,800

59,700

1,427,900

57,800

1,322,500

55,800

1,218,900

53,900

1,121,500

52,000

1,028,100

50,100

937,700

48,200

852,100

46,400

772,000

Pipe Body
Combined Loading Table (Torque-Tension)
Pipe Body

Pipe Body OD

80 % Inspection Class

Pipe Body Torque

(in)

5.875

Wall Thickness (in) 0.750

Pipe Body Grade

G-105

9,700

19,400

29,100

38,800

48,500

58,200

67,900

77,500

87,200

96,900

106,600

980,600

968,200

947,300

917,100

876,900

825,000

759,200

676,300

566,700

410,900

21,700

(ft-lbs)

Pipe Body Max


984,700
Tension
(lbs)

Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.

02-03-2014

You might also like