Drill Pipe Performance Sheet

www.NOV.com/GrantPrideco

Phone: +1 (281) 878-8000

Drill Pipe Configuration


Pipe Body OD
Pipe Body Wall Thickness
Pipe Body Grade
Drill Pipe Length
Connection
Tool Joint OD
Tool Joint ID
Pin Tong
Box Tong

(in)
(in)

(in)
(in)
(in)
(in)

80 % Inspection Class
Nominal Weight Designation
25.60
(ft) 31.9
Drill Pipe Approximate Length
(in) 3/32 Raised
SmoothEdge Height
(psi) 120,000
Tool Joint SMYS
Upset Type
IEU
(in) 5.125
Max Upset OD (DTE)
Friction Factor
1.0

5.000
0.500
G-105
Range2
XT50
6.625
3.750
10
15

Note: Tong space may include hardfacing.

Drill-Pipe Length

Drill Pipe Performance

Best Estimates

Performance of Drill Pipe with Pipe Body at

(without Coating)

80 % Inspection Class
Applied Make-up
Torque

Max Tension
Operational
Torque (ft-lbs)
(lbs)

(ft-lbs)

Maximum MUT

46,100

Minimum MUT

38,600

Tension Only
Combined Loading

Tension Only
Combined Loading

0
40,900

580,600
402,200

0
32,500

580,600
476,100

Drill Pipe Adjusted Weight

Fluid Displacement
Fluid Displacement
Fluid Capacity
Fluid Capacity
Drift Size

29.32
0.45
(Bbls/ft) 0.0107
(gal/ft) 0.63
(Bbls/ft) 0.0150
(in) 3.625

XT50

6.625

Applied Make-up
Tension at Shoulder
Torque
Separation
(ft-lbs)

46,100
38,600

(ft-lbs)
(lbs)

(lbs)

Tensile Limited
1,066,100

SmoothEdge Height
(in)
(lbs)

3/32 Raised
6.812
1,658,000

Assumed Elevator Bore Diameter

28.27
0.43
0.0103
0.65
0.0154

(lbs/ft)

0.62
0.0149

OD X

(in)

3.750

Tension at Connection
Yield
(lbs)

ID

(in)

120,000

(psi)

Tool Joint Dimensions


Balanced OD

876,500
1,078,000

(in)

Minimum Tool Joint OD for API


(in)
Premium Class
Minimum Tool Joint OD for
Counterbore

(in)

6.406
6.066
6.066

76,900
1,078,000

Elevator Shoulder Information


Box OD
Elevator Capacity

(least accurate)

(gal/ft)

Note: The maximum make-up torque should be applied when possible.


Note: To maximize connection operational tensile, a MUT (T4) = 39,000 (ft-lbs) should be applied.

Tool Joint Torsional Strength


Tool Joint Tensile Strength

Nominal

(with Coating)

Note: Oil field barrel equals 42 US gallons.


Note: Drill pipe assembly values are best estimates and may vary due to pipe body mill tolerance, internal plastic coating, and other factors.

Connection Performance
Maximum Make-up Torque
Minimum Make-up Torque

Range2

(in)

Elevator OD 3/32 Raised


Nominal Tool Joint
Worn to Bevel
OD
Diameter

Worn to Min TJ OD for


API Premium Class

6.625
1,440,200

6.066
826,700

Pipe Body Slip Crushing Capacity

Pipe Body Configuration

Nominal
Assumed Slip Length
Transverse Load Factor (K)

(lbs)
(in)

Pipe Body Performance

519,400

(ft-lbs)

(ft-lbs)
(psi)
(psi)
(in)
(in)
(in)
(in^2)
(in^2)
(in^2)
(in^3)
(in^3)

5 (in) OD

80 % Inspection Class
412,100

Pipe Body Configuration

(lbs)

0.500 (in) Wall

G-105 )

API Premium Class


412,100

Note: Slip Crushing: Slip crushing load is calculated with the Spiri-Reinhold equation from Why Does Drill Pipe
Fail in the Slip Area World Oil, 1959 for the slip length and transverse load factor shown and is for reference
only. Slip crushing is dependent on the slip design and condition, coefficient of friction, loading conditions, time in
slips, drill pipe OD and wall variation, and other factors. Consult with the slip manufacturer for additional
information.

16.5
4.2

Nominal
Pipe Tensile Strength
Pipe Torsional Strength
TJ/PipeBody Torsional Ratio
80% Pipe Torsional Strength
Burst
Collapse
Pipe OD
Wall Thickness
Nominal Pipe ID
Cross Sectional Area of Pipe Body
Cross Sectional Area of OD
Cross Sectional Area of ID
Section Modulus
Polar Section Modulus

(in)

Note: Elevator capacity based on assumed Elevator Bore, no wear factor, and contact stress of 110,100psi.
Note: A raised elevator OD increases elevator capacity without affecting make-up torque.

5.219

Slip Crushing Capacity

6.318
1,096,600

6.812

742,200
73,200
1.05
58,500
18,375
18,900
5.000
0.500
4.000
7.069
19.635
12.566
7.245
14.491

5 (in) OD

80 % Inspection Class
580,600
56,800
1.35
45,400
16,800
16,042
4.800
0.400
4.000
5.529
18.096
12.566
5.621
11.243

0.500 (in) Wall

G-105 )

API Premium Class


580,600
56,800
1.35
45,400
16,800
16,042
4.800
0.400
4.000
5.529
18.096
12.566
5.621
11.243

Note: Nominal Burst


calculated at 87.5% RBW
per API.

Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully
responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied
warranty is intended. Drill pipe assembly properties are calculated based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear
conditions (remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance
ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the application. For API connections that have different pin and box IDs, tool joint ID refers to
the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.

www.NOV.com/GrantPrideco/CustomerFeedback

Customer Created 02-03-2014

Operational Limits of Drill Pipe


Connection
Pipe Body

XT50
80 % Inspection Class

Tool Joint OD

(in)

6.625

Tool Joint ID

Pipe Body OD

(in)

Wall Thickness (in) 0.500

(in)

Combined Loading for Drill Pipe at


Maximum Make-up Torque = 46,100
Operational Assembly
Torque
Max Tension
(ft-lbs)

0
2,200
4,300
6,500
8,600
10,800
12,900
15,100
17,200
19,400
21,500
23,700
25,900
28,000
30,200
32,300
34,500
36,600
38,800
40,900

(lbs)

580,600
580,100
578,900
576,700
573,900
570,000
565,400
559,600
553,300
545,600
537,300
527,500
516,600
505,000
491,600
477,400
461,000
443,800
423,800
402,200

Pipe Body Grade

G-105

Combined Loading for Drill Pipe at


Minimum Make-up Torque = 38,600

(ft-lbs)

Connection Max
Pipe Body
Max Tension Tension

(lbs)

Tool Joint Specified Minimum


120,000
(psi)
Yield Strength

3.750

Operationa Assembly
l Torque
Max Tension
(ft-lbs)

(lbs)

Pipe Body
Max Tension

(lbs)

(lbs)

(ft-lbs)

Connection
Max Tension

(lbs)

580,600

580,600

1,066,100

580,600

876,500

580,100

876,500

1,700

580,300

580,300

1,066,100

876,500

3,400

579,500

579,500

1,066,100
1,066,100

578,900
576,700

876,500

5,100

578,200

578,200

573,900

876,500

6,800

576,400

576,400

1,066,100

570,000

876,500

8,500

574,000

574,000

1,066,100

565,400

876,500

10,300

570,900

570,900

1,066,100

876,500

12,000

567,400

567,400

1,066,100

876,500

13,700

563,400

563,400

1,066,100

876,500

15,400

558,800

558,800

1,066,100
1,066,100

559,600
553,300
545,600
537,300

876,500

17,100

553,600

553,600

527,500

876,500

18,800

547,800

547,800

1,066,100

516,600

876,500

20,500

541,400

541,400

1,066,100

505,000

876,500

22,200

534,300

534,300

1,066,100

876,500

23,900

526,600

526,600

1,066,100

876,500

25,600

518,200

518,200

1,066,100

508,400

508,400

1,066,100
1,066,100

491,600
477,400
461,000

27,400

876,500

443,800

876,500

29,100

498,500

498,500

423,800

876,500

30,800

487,700

487,700

1,066,100

402,200

876,500

32,500

476,100

476,100

1,066,100

Operational drilling torque is limited by the Make-up Torque.

Operational drilling torque is limited by the Make-up Torque.

Connection
Make-up Torque Range
Make-up Torque
(ft-lbs)

Min MUT

Max MUT

38,600
39,400
40,300
41,100
41,900
42,800
43,600
44,400
45,300
46,100

Connection Max
Tension

(lbs)

1,066,100
1,067,400
1,041,800
1,019,000
996,200
970,600
947,800
925,000
899,300
876,500

Note: Recommended MUT should always be used when possible. If not possible, MUT should be as close to Recommended MUT as possible.
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.

02-03-2014

Connection Wear Table


Connection

XT50

Tool Joint OD

Connection
Wear

Tool
Joint OD

New OD

(in)

6.625
6.574
6.523
6.473
6.422
6.371
6.32
6.269
6.218
6.168
6.117
6.066

Worn OD

(in)

6.625

Tool Joint ID

(in)

Tool Joint Specified Minimum


120,000
(psi)
Yield Strength

3.750

Connection Max
Tension

Connection
Torsional
Strength (ft-lbs)

Max
MUT

76,900
76,900
76,900
76,900
76,900
75,000
72,300
69,600
67,000
64,400
61,800
59,300

46,100
46,100
46,100
46,100
46,100
45,000
43,400
41,800
40,200
38,600
37,100
35,600

(ft-lbs)

Connection Max
Tension

Min MUT

(lbs)

(lbs)

(ft-lbs)

876,500
871,700
866,800
861,700
856,300
880,200
916,800
952,800
988,000
1,022,600
1,036,000
995,600

38,400

1,060,600

38,400

1,066,300

38,400

1,072,300

38,400

1,077,400

38,400

1,070,700

37,500

1,067,900

36,100

1,036,500

34,800

1,007,700

33,500

978,900

32,200

949,600

30,900

905,100

29,600

827,800

Pipe Body
Combined Loading Table (Torque-Tension)
Pipe Body

Pipe Body OD

80 % Inspection Class

Pipe Body Torque

(in)

Wall Thickness (in) 0.500

Pipe Body Grade

G-105

5,200

10,300

15,500

20,600

25,800

31,000

36,100

41,300

46,400

51,600

56,700

578,100

570,900

558,500

541,000

517,100

486,300

448,000

398,300

334,400

241,900

27,100

(ft-lbs)

Pipe Body Max


580,600
Tension
(lbs)

Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.

02-03-2014