www.NOV.com/GrantPrideco
(in)
(in)
(in)
(in)
(in)
(in)
80 % Inspection Class
Nominal Weight Designation
25.60
(ft) 31.9
Drill Pipe Approximate Length
(in) 3/32 Raised
SmoothEdge Height
(psi) 120,000
Tool Joint SMYS
Upset Type
IEU
(in) 5.125
Max Upset OD (DTE)
Friction Factor
1.0
5.000
0.500
G-105
Range2
XT50
6.625
3.750
10
15
Drill-Pipe Length
Best Estimates
(without Coating)
80 % Inspection Class
Applied Make-up
Torque
Max Tension
Operational
Torque (ft-lbs)
(lbs)
(ft-lbs)
Maximum MUT
46,100
Minimum MUT
38,600
Tension Only
Combined Loading
Tension Only
Combined Loading
0
40,900
580,600
402,200
0
32,500
580,600
476,100
Fluid Displacement
Fluid Displacement
Fluid Capacity
Fluid Capacity
Drift Size
29.32
0.45
(Bbls/ft) 0.0107
(gal/ft) 0.63
(Bbls/ft) 0.0150
(in) 3.625
XT50
6.625
Applied Make-up
Tension at Shoulder
Torque
Separation
(ft-lbs)
46,100
38,600
(ft-lbs)
(lbs)
(lbs)
Tensile Limited
1,066,100
SmoothEdge Height
(in)
(lbs)
3/32 Raised
6.812
1,658,000
28.27
0.43
0.0103
0.65
0.0154
(lbs/ft)
0.62
0.0149
OD X
(in)
3.750
Tension at Connection
Yield
(lbs)
ID
(in)
120,000
(psi)
876,500
1,078,000
(in)
(in)
6.406
6.066
6.066
76,900
1,078,000
(least accurate)
(gal/ft)
Nominal
(with Coating)
Connection Performance
Maximum Make-up Torque
Minimum Make-up Torque
Range2
(in)
6.625
1,440,200
6.066
826,700
Nominal
Assumed Slip Length
Transverse Load Factor (K)
(lbs)
(in)
519,400
(ft-lbs)
(ft-lbs)
(psi)
(psi)
(in)
(in)
(in)
(in^2)
(in^2)
(in^2)
(in^3)
(in^3)
5 (in) OD
80 % Inspection Class
412,100
(lbs)
G-105 )
Note: Slip Crushing: Slip crushing load is calculated with the Spiri-Reinhold equation from Why Does Drill Pipe
Fail in the Slip Area World Oil, 1959 for the slip length and transverse load factor shown and is for reference
only. Slip crushing is dependent on the slip design and condition, coefficient of friction, loading conditions, time in
slips, drill pipe OD and wall variation, and other factors. Consult with the slip manufacturer for additional
information.
16.5
4.2
Nominal
Pipe Tensile Strength
Pipe Torsional Strength
TJ/PipeBody Torsional Ratio
80% Pipe Torsional Strength
Burst
Collapse
Pipe OD
Wall Thickness
Nominal Pipe ID
Cross Sectional Area of Pipe Body
Cross Sectional Area of OD
Cross Sectional Area of ID
Section Modulus
Polar Section Modulus
(in)
Note: Elevator capacity based on assumed Elevator Bore, no wear factor, and contact stress of 110,100psi.
Note: A raised elevator OD increases elevator capacity without affecting make-up torque.
5.219
6.318
1,096,600
6.812
742,200
73,200
1.05
58,500
18,375
18,900
5.000
0.500
4.000
7.069
19.635
12.566
7.245
14.491
5 (in) OD
80 % Inspection Class
580,600
56,800
1.35
45,400
16,800
16,042
4.800
0.400
4.000
5.529
18.096
12.566
5.621
11.243
G-105 )
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully
responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied
warranty is intended. Drill pipe assembly properties are calculated based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear
conditions (remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance
ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the application. For API connections that have different pin and box IDs, tool joint ID refers to
the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
www.NOV.com/GrantPrideco/CustomerFeedback
XT50
80 % Inspection Class
Tool Joint OD
(in)
6.625
Tool Joint ID
Pipe Body OD
(in)
(in)
0
2,200
4,300
6,500
8,600
10,800
12,900
15,100
17,200
19,400
21,500
23,700
25,900
28,000
30,200
32,300
34,500
36,600
38,800
40,900
(lbs)
580,600
580,100
578,900
576,700
573,900
570,000
565,400
559,600
553,300
545,600
537,300
527,500
516,600
505,000
491,600
477,400
461,000
443,800
423,800
402,200
G-105
(ft-lbs)
Connection Max
Pipe Body
Max Tension Tension
(lbs)
3.750
Operationa Assembly
l Torque
Max Tension
(ft-lbs)
(lbs)
Pipe Body
Max Tension
(lbs)
(lbs)
(ft-lbs)
Connection
Max Tension
(lbs)
580,600
580,600
1,066,100
580,600
876,500
580,100
876,500
1,700
580,300
580,300
1,066,100
876,500
3,400
579,500
579,500
1,066,100
1,066,100
578,900
576,700
876,500
5,100
578,200
578,200
573,900
876,500
6,800
576,400
576,400
1,066,100
570,000
876,500
8,500
574,000
574,000
1,066,100
565,400
876,500
10,300
570,900
570,900
1,066,100
876,500
12,000
567,400
567,400
1,066,100
876,500
13,700
563,400
563,400
1,066,100
876,500
15,400
558,800
558,800
1,066,100
1,066,100
559,600
553,300
545,600
537,300
876,500
17,100
553,600
553,600
527,500
876,500
18,800
547,800
547,800
1,066,100
516,600
876,500
20,500
541,400
541,400
1,066,100
505,000
876,500
22,200
534,300
534,300
1,066,100
876,500
23,900
526,600
526,600
1,066,100
876,500
25,600
518,200
518,200
1,066,100
508,400
508,400
1,066,100
1,066,100
491,600
477,400
461,000
27,400
876,500
443,800
876,500
29,100
498,500
498,500
423,800
876,500
30,800
487,700
487,700
1,066,100
402,200
876,500
32,500
476,100
476,100
1,066,100
Connection
Make-up Torque Range
Make-up Torque
(ft-lbs)
Min MUT
Max MUT
38,600
39,400
40,300
41,100
41,900
42,800
43,600
44,400
45,300
46,100
Connection Max
Tension
(lbs)
1,066,100
1,067,400
1,041,800
1,019,000
996,200
970,600
947,800
925,000
899,300
876,500
Note: Recommended MUT should always be used when possible. If not possible, MUT should be as close to Recommended MUT as possible.
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
02-03-2014
XT50
Tool Joint OD
Connection
Wear
Tool
Joint OD
New OD
(in)
6.625
6.574
6.523
6.473
6.422
6.371
6.32
6.269
6.218
6.168
6.117
6.066
Worn OD
(in)
6.625
Tool Joint ID
(in)
3.750
Connection Max
Tension
Connection
Torsional
Strength (ft-lbs)
Max
MUT
76,900
76,900
76,900
76,900
76,900
75,000
72,300
69,600
67,000
64,400
61,800
59,300
46,100
46,100
46,100
46,100
46,100
45,000
43,400
41,800
40,200
38,600
37,100
35,600
(ft-lbs)
Connection Max
Tension
Min MUT
(lbs)
(lbs)
(ft-lbs)
876,500
871,700
866,800
861,700
856,300
880,200
916,800
952,800
988,000
1,022,600
1,036,000
995,600
38,400
1,060,600
38,400
1,066,300
38,400
1,072,300
38,400
1,077,400
38,400
1,070,700
37,500
1,067,900
36,100
1,036,500
34,800
1,007,700
33,500
978,900
32,200
949,600
30,900
905,100
29,600
827,800
Pipe Body
Combined Loading Table (Torque-Tension)
Pipe Body
Pipe Body OD
80 % Inspection Class
(in)
G-105
5,200
10,300
15,500
20,600
25,800
31,000
36,100
41,300
46,400
51,600
56,700
578,100
570,900
558,500
541,000
517,100
486,300
448,000
398,300
334,400
241,900
27,100
(ft-lbs)
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
02-03-2014