Contents / Introduction

Contents

Contents

Introduction

Applications

Type Designation

Multi-turn Actuators

Design Principle

6-7

Functions
Open-Close Duty
Regulating Duty
Limit Switching
Torque Switching

8
8
8
9
10

Control Equipment
Micro Switches
Reduction Gear Unit
Position Indicators
Intermediate Switch
Manual Operation
Top Bevel Gear Set
Space Heater
Motors

11
11
12
12
13
13
13
13
14-15

Actuators for Regulating Duty


Actuator Types
Auma Norm Actuators
Auma Integral Starter Actuators
Control Versions
Auma Compact
Auma e-pac

16-20
21
21
21
22
22
23

Interface
Valve Attachment
Output Drives
Electrical Connection
Actuator Gearbox Combination

24
24
24
25
26

Service Conditions
Enclosure Protection
Ambient Temperature
Explosion Proof

27
27
27
28

General
Data Sheets
Technical Data Open-Close Duty
Electrical Data Open-Close Duty
Technical Data Regulating Duty
Electrical Data Regulating Duty
Dimension Sheet, Norm
Dimension Sheet, Compact
Dimension Sheet, E-pac
Output Drives
Linear Thrust Unit
Terminal Plan (Norm)
Wiring Diagram (Integral Starter)
Legend - Integral Starter

29
30-31
32-33
34
35
36
37
38
39
40
41
42
43

Introduction
In the course of ever increasing demand for
automation in all sectors of industries, electric
actuators for process control and regulation
have become more and more important. For
more than 30 years, Auma concentrates on
design, development and manufacturing of
electric actuators. During this period, Auma
has acquired a know-how in this field that can
hardly be surpassed. Auma today is one of the
leading manufacturers of electric actuators in
the world.
Auma India (Ltd.,) is now a subsidiary of
Auma Werner Riester Gmbh & Co. KG,
Germany manufacturing electric actuators
under brand name
. Auma (India) Ltd.,
started its operations in the year 1985 with HQ
and sophisticated manufacturing base at
Bangalore.
Sales support and after sales service are
provided by network consisting of regional
offices & service centers.

Applications
Auma multi-turn actuators of the type range SA
can be used wherever the automation of the
valve is required. The adoption to the
requirements of nearly every valve automation
task is possible. This is on account of :
An extermely wide torque range
Various combination possibilities with
Auma Valve Gear boxes. Thereby the torque
range can be further extended and / or the
multiturn actuator can be converted into
part turn, lever or linear actuator.
A large variety of versions, whether for open
or closed loop control, explosion proof
applications, a suitable version is available.
Energy
Power Plants
Air Pollution Control
District Heating
Pipelines

Water / Waste Water


Water Works
Water Pipelines
Sewage Treatment
Pump Stations
Locks / Dams

Chemical Industry
Petro-chemical
Chemical
Pharmaceutical

Others
Air Conditioning
Steel Mills
Ship Building
Cement Plants
Food Industry

Type Designation

Auma
Norm

OPEN-CLOSE Duty

Model : SA

Regulating Duty

Model : SAR

Auma
Compact
Actuator
Types

OPEN-CLOSE Duty Model :SA Compact


Regulating Duty

Model : SAR Compact

Auma
Integral Starter
Auma
e-pac

Regulating Duty

Model : SAR e-pac

Expl. Proof OPEN-CLOSE Duty Model :SAEx


Norm
Regulating Duty
Model : SAREx

Auma
Flame Proof /
Explosion Proof

Torque Ratings

OPEN-CLOSE Duty Model :SA e-pac

Expl. Proof OPEN-CLOSE Duty Model :SACEx


Compact Regulating Duty
Model : SARCEx
Output Drives

3 m kg
6 m kg
12 m kg
15 m kg
25 m kg
30 m kg
50 m kg
60 m kg
100 m kg

A Stem nut
B Plug Sleeve
C Dog Coupling
D Stub Shaft
E Bore with Keyway

4 rpm
5.6 rpm
8 rpm
11 rpm
16 rpm
22 rpm
32 rpm
45 rpm
63 rpm
90 rpm
125 rpm
180 rpm

Output Speed

Type Designation : Example


SA
Model
Torque Rating

12

22
Output Speed in RPM
Output Drive

Multi-turn Actuators

Multi-turn Actuator SA3 - SA100


Torque range 3 m kg to 100 m kg
Output speed 4 rpm to 180 rpm

Multi-turn Actuator
Integral Starter - Compact

Multi-turn Actuator
Integral Starter - e pac

Multi-turn Actuator
Flame Proof / Explosion Proof
5

Design Principle

Manual Operation

Motor
Terminal
Compartment

Change Gears

Reduction Gearing

Valve Attachment

Switch Compartment

Design Principle
Motor

Terminal Compartment

Especially high starting torque is frequently


required to unseat valves from end positions.
The motors developed by Auma fulfil this
basic requirement.

All electrical connections are terminated inside


the terminal compartment. Screw type terminals
are provided for easy connections. Multi-pin
plug-socket connector can be provided for ease
of connections & maintenance.

Change Gears

Valve Attachment

Auma actuators are driven by special


combination of gears which are outside the
grease filled housing & require no lubrication.
If required, output speed can be easily altered
by changing the gear pair and / or motor at
site.

The mounting flange is according to ISO 5210 /


DIN 3210. Various output drives are available
for adaption to various types of valves.

Reduction Gearing

Manual Operation

A well proved principle of worm gearing is


used to reduce the motor speed to required
output speed of actuator. Self-locking feature
is achieved by worm gearing upto 90 output
rpm. Worm shaft and output shaft with worm
wheel run in ample sized bearings. The sliding
worm is positioned between two sets of
springs on worm shaft. The worm moves
axially in relation to thrust which is the
measure for torque. Via lever & gears the
torque is transmitted to control unit.

For commissioning or in an emergency, actuator


can be operated with hand wheel. When starting
the motor, the manual drive is automatically
disengaged.

Switch Compartment
Depending upon type of valve, the actuator
must be switched off at end positions by limit
switch or torque switch. For this purpose,
independent limit switching or torque
switching devices are provided in the switch
compartment. The switching devices are easily
accessible for any setting at site.

Functions
Open Close Duty
The characteristic feature of this actuator is
open loop. The normal valve positions in
OPEN-CLOSE Duty are end positions OPEN
and CLOSED. After receiving command, the
actuator operates the valve to one of the end
positions or if necessary to a preset
intermediate position. The valves are operated
relatively seldom, the time intervals can span
between a few minutes to several months.
Auma multi-turn actuators type SA for open
close service are rated for short time duty
S2-15min.
Typical Characteristics of
OPEN-CLOSE DUTY
Regulating / Modulating Duty
The characteristic feature of this actuator is
closed loop in which input command signal to
actuator is directly influenced by the flow
through the valve. Regulating / Modulating
duty actuator SAR operates between two set
bands between open-close positions depending
upon actual valve position and feedback signal.
The motors of these actuators are rated for
intermittent duty S4-25%. The mechanical
components and motor are designed to withstand
a large number of operations required for
modulating applications.

Typical Characteristics of
Regulating / Modulating Duty
Pemissible number of starts-stops depends upon
actuator size & speed. The details are available
in Data Sheets.

Short Time and Intermittent Duty IS 12824


Short time Duty S2

Intermittent Duty S4

Operation at constant load during a given


time, less than that required to reach thermal
equilibrium, followed by a rest and deenergized period of sufficient duration to reestablish machine temperatures within 2oC.

A sequence of identical duty cycles, each cycle


including a significant period of starting, a period
of operation at constant load and a rest and deenergized period. These periods being too short
to attain thermal equilibrium during one duty
cycle.

The duration of short time is limited to 15, 30


or 60 min.

The relative on time at S4-25% is limited to


25% of the cycle time.

Functions
Limit Switching
The limit switching enables to switch off the
actuator when reaching defined valve
position, usually end positions. The valve
travel is measured by mechanical counter gear
mechanism which when reaching the set

switching points operate the electrical limit


switches by cams. The setting accuracy is 1/10 of
a turn of actuator output shaft.
In limit switching, two train counter gear and
four train counter gear versions are available :

Two Train Counter Gear


For Two train counter gear, two limit switches,
one for each direction of travel having 1 NO
+ 1 NC or 2 NO + 2 NC contacts are provided.
The number of spindle turns can be set
between 1 and 480 or 1 and 4800.

Two Train Counter Gear


Four Train Counter Gear
If limit switching is required at two end
positions only, two train counter gear is used.
However, if two additional intermediate
switching positions are desired, Four Train
Counter Gear is required. This limit switching
has 4 counter gears and 4 micro switches. Two
counter gears are used to switch off at end
positions as in Two Train Counter Gear. The
other two are available for setting any desired
intermediate positions between end positions.
After cam actuation, the switches remain
actuated till reaching end of valve travel.
Examples of such application are :

The accuracy of setting is 1/10 of a turn of


actuator output shaft. For four train counter
gear, 4 limit switches of 1 NO + 1 NC or 2 NO
+ 2 NC contacts are provided.

To stop at intermediate position


Sequence control, that is to start
another equipment like pump or bypass
valve actuator after certain travel
of valve.
Four Train Counter Gear

Functions
Torque Switching
The torque switching enables to switch off the
actuator when pre-determined torque is
reached instead of a defined position. The
torque switching works on principle of sliding
worm.
Axial displacement of worm proportional to
thrust is transmitted to torque switches.
Torque switches operate in closing & opening
directions. The required tripping torque can be
easily set on the graduated dial. If limit switch
cut off is selected prior to torque switch, then
torque switch serves as overload protection.
For tight seating of certain valves, the actuator
must be operated to end position CLOSED
with defined force. Such operation can be
carried out by torque seating. Limit seating is
commonly used in the end position OPEN.

Running Indication
Blinker switch is provided in the actuator and
can be used as running indicator.

10

Torque Switching
When torque seating is used at end position,
limit switches can be used for signalization.
Therefore actuator controls can differentiate
whether actuator was switched off by torque
switch or by limit switch. Micro switches of
torque switching are provided with 1 NO + 1 NC
or 2 NO + 2 NC contacts for both open & close
directions.

Control Equipment
Micro Switches
With the help of micro switches, mechanical
parameters such as travel & torque are
converted into electrical signals for actuator
control. There are four switches in the basic
version :
One limit switch each for the end
positions OPEN and CLOSE
One torque switch each for the
directions OPEN and CLOSE.

Limit switches are tripped when an end position


is reached and torque switches are tripped when
the set tripping torque is exceeded.
The micro switches are sealed to enclosure
protection class IP66, as per IS 13947. The micro
switches have double break change over
potential free contacts. The circuit is interrupted
simultaneously at two points. The basic versions
of the switch contacts are of silver. For low
current ratings, micro switches with gold plated
contacts are available.

Single and Tandem Micro Switches


Switching another circuit also with
different voltage & current

Limit and Torque Switches are available in


single or tandem versions.

Safety function, to operate with single


switch
Multiplying the available contacts,
example for signalization.
For such applications, a relay is recommended
since there may be small differences in tripping
points of tandem switches.

Single Micro Switch

Limit or Torque Switches in tandem version


have additional switching contacts. These
contacts can be wired for following applications :

Tandem Micro Switch

Micro Switch Ratings


Type of Switch

Limit and
Torque

Blinker

Type of
Current

Rating in Amp at
75 V 125 V 250 V
30 V

AC, cos O = 0.8


Inductive

DC inductive

0.2

0.1

DC resistive

0.5

0.25

AC, cos O = 0.8


Inductive

Approx. Electrical
contact rating
500,000 cycles at
250 V AC, 5A
50,000 cycles at
250 V DC, 0.1A
50,000 cycles at
250 V DC, 0.25A

11

Control Equipment
Reduction Gear Unit
A reduction gear unit (RGU) in the actuator is
used for mechanical position indication,
remote position indication & for operation of
intermediate switches. The output shaft of the
actuator drives final output shaft of RGU
through a series of reduction gears and final
o
shaft turns by approximately 270 while
actuator output shaft performs full number of
turns as set on two train or four train counter
gear unit. The reduction gear ratio needed for
each particular case is fitted at works if the
ratio is known. For this purpose fixed RGU
is supplied. If the ratio needs to be altered

at site, variable ratio RGU is available which


allows simple modification at site depending
upon number of turns of output shaft for full
stroke of valve.

Reduction Gear Unit (RGU)


Position Indicators
Mechanical Position Indicator
The position of the valve is indicated
continuously by adjustable discs having
symbols for OPEN and CLOSE. The discs can
be seen through an indicator glass on switch
compartment cover. The open-close discs can
be set to coincide with limit switching. The
mechanical position indicator requires
reduction gear unit for operation.
Remote Position Indicator
The position of the valve can be transmitted as
a continuous signal for remote indication. A
potentiometer mounted on RGU is used for
this purpose. A power supply unit provides
necessary voltage to the potentiometer. The
o
potentiometer rotates through 270 for one full
stroke of valve & output signal from
potentiometer is proportional to valve travel.
Thus the actual position of the valve can be

Mechanical Position Indicator


read off continuously on position meter
calibrated & mounted on control panel.
Technical Data
Std: 220 ohms, 3W, Linearity + 3%
Optional : 100, 560, 1000 ohms,
Potentiometer 3W, Linearity + 3%
Precision : 200, 500, 1000 ohms,
1W, Linearity + 0.5%
Power
PS01, input 220V, 50Hz, output
Supply Unit 24V DC
0 - 100% in various sizes
Position
Meter
Digital Remote Position Indicator
Actual position display can be provided by
digital remote position indicator, which
displays open position in percentage.

Remote Position Indicator


12

Control Equipment
Intermediate Switches
With this limit switching, additional switching
points can be set for each direction of rotation.
The switching can be set between 25 and 75%
of valve travel in each direction. The switch
sub assembly consisting of 2 or 4 cam switches
is mounted on output shaft of RGU. Each
micro switch has 1 NO + 1 NC contact.
Intermediate Switches
Manual Operation
For commissioning or in an emergency when
there is no power supply, actuator can be
operated by hand wheel. The manual drive is
engaged by means of a lever. When motor
starts running, the manual drive gets
disengaged immediately & hand wheel does
not rotate during power operation.
In manual operation, hammer blow can be
effected with hand wheel. The hammer blow
makes it possible to open a jammed or rarely
operated valve.

Top Bevel Gear Set


Manual effort on hand wheel can be further
reduced by using a side mounted hand wheel
instead of standard hand wheel. Reduction
ratios available are
2:1
SA3 / 6 / 12 / 15
3:1
SA25 / 30 / 50 / 60
4:1
SA 100
Instead of hand wheel, a chain pulley can be
provided for actuators mounted in inaccessible
zones.
Top Bevel Gear Set
Space Heater
Condensation in the actuator is possible due to
wide fluctuation of the ambient temperature.
The heater integrated in the control unit
prevents the water condensation. The heater is
rated for continuous duty. This may be
continuously energized or when the actuator
is not operating.

Technical Data
Volts, AC
Resistance
ohms
Rating
Watts

230

230

110

110

5K

2.7K

1.2K

0.6K

10

20

10

20

13

Control Equipment
Motors
As a standard, Auma multi turn actuators are
equipped with 3 phase induction motors.
Auma motors are class F insulated and
withstand winding temperature upto 140o C.

Single Phase AC Motors


Auma actuators can be supplied with single
phase AC motor. The required capacitor is fitted
in the terminal compartment cover.

The motors are used for short time duty (S2-15


min or S4-25% as per IS 12824) and provide
approximately three times rated torque for
short duration. The size of the motor is smaller
compared to continuous duty motor S1 of
same output power. This results in reduced
inertia of the rotor and therefore less
overshoot after switching off of motor. Auma
motors are designed for enclosure protection
class IP 68 when mounted on the actuator. All
motor cables are brought to terminal
compartment cover from inside of the actuator
thus avoiding terminal box.

DC Motors
Auma actuators are also available with DC
motors. These motors operate on 24 V, 110 V or
220 V DC supply.
AC Motors with Other Voltages and
Frequency
Three phase induction motors are available in
wide range of operating voltages from 220 V to
560 V and operating frequency of 50 or 60 Hz.

Technical Data

Voltages

Permissible Variation
in Voltage

3 ph AC Motor

1 ph AC Motor

50/60 Hz : 220 V, 380 V


400 V, 415 V
440 V, 460 V
480 V, 500 V
550 V

50/60 Hz :
220 V - 240 V
110 V - 220 V

+ 10%

+ 10%

Mounting

C Type Flange, B14, IS 2223

Enclosure Protection

IP 67 or IP 68 after mounting

Type of Cooling

Surface Cooled

Insulation Class

F Class, IS 325 (max. temp. rise 140 C)

Starting

Direct on line

Type of Duty

S2-15 min. or S4-25 % IS 12824

Direction of Rotation

Clockwise and anticlockwise

Motor Protection

3 thermo switches

14

DC Motor
220 V
110 V
48 V
24 V
+ 10%

2 thermo switches

4 thermo switches

Control Equipment
Motor Protection
Motor winding may get overheated if the
actuator is run beyond rated duty or if the
rotor is stalled for considerably longer time or
if too high ambient temperature is
encountered. In order to protect the motor
against over heating, thermo switches are
embedded in the windings of three phase,
single phase AC motors and DC motors. When
integrated into the control circuits, they will
protect the motor against damage due to
excessive winding temperature.

Technical Data
AC Voltage

Switch Rating

250 V AC
Cos O = 1
250 V AC
Cos O = 0.6

2.5 A
1.6 A

Tripping Temp 140o C


o

Reset Temp 90 - 110 C


The thermo switches interrupt the control
circuit as soon as winding temperature of
o
140 C is exceeded. After cooling down to a
o
temperature of approx. 110 C, the actuator can
be switched on once again. PTC thermistors
can also be provided for motor protection.

Note : The motor protection device must be


integrated into the controls, otherwise warranty
for motor is not valid.

Output Speeds
With large range of available output speeds,
almost every required operating time can be
achieved with Auma actuators.
The actuator output speed is determined by
the motor speed, change gears and reduction
gear ratio of worm / worm wheel.
The output speeds are available from 4 - 180
rpm in geometric progression of 1: 1.4.
During trial run, if found necessary, the
output speed can be easily changed by

exchanging the change wheels and or motor at


site. The grease filled housing need not be
opened for this purpose. The torque switch
setting & limit switch setting remains the same.
For actuators with output drive A (Stem nut),
max. permissible stem velocity must be
observed:
- for gate valves max. 500 mm/min
- for globe valves max. 250 mm/min
For higher velocities it is recommended to use
spring loaded stem nut type AF (special design).

Self Locking
Auma multi turn actuators SA/SAR3 to
SA/SAR100 are self locking (see note below)
with exception of output speeds 125 & 180
rpm. Actuators with 125 & 180 rpm are having
double start worm drive. After torque switch is
tripped, the sliding worm may move back to
initial position by the action of torque
measuring springs. This allows torque switch
to be released. If control system provides
continuous signal, this results in hunting of
motor. This can be avoided by the use of
auxiliary relay.

Note on Self Locking :


Self-locking gearing does not ensure safe
stopping after an operation. If this is required,
separate locking arrangement must be provided.

15

Actuators for Regulating Duty


Description of Regulating Duty
Auma actuators of type SAR are suitable for
Regulating duty / Modulating duty. SAR
actuator operates between two set bands in
closed loop and the motor is started, stopped
& reversed at short intervals to correct the
deviation from the set value. SAR actuators
differ from SA actuators in several respects :
- 4 pole motors are used to reduce overshoot
- Worm with high quality finish on flanks for
better efficiency
- Disc springs on worm shaft are pre
compressed to reduce dead band when
reversing.
While selecting Auma actuators for regulating
duty applications, following points should be
noted :

Max. No. of starts


1200 cycles / hour with motor power upto
0.55 kW & 600 cycles / hour with motor
power above 0.55 kW.
Output speed of actuator max. 45 rpm.
Torque for regulating duty should not exceed
50% of max. torque of actuator.
Max. torque of actuator can be used for
seating & unseating of the valve.
For reversing service, duration of impulse
should be minimum of 50 ms.
Electronic position transducer or precision
potentiometer should be used for remote
position indication.
The motor should be short time duty
class S4 - 25%.
The SAR actuator basically consists of
control units as explained in following
diagram.

Principle of Operation

SAR

Regulating duty actuator

CU01

: Electronic positioner

MSAR

Sensor for actuator, i.e.


position transmitter at actuator
(potentiometer or inductive
LVDT)

: Regulating valve

: Sensor for regulating valve

MU

: Signal converter for sensor

Signal converter for SAR i.e.


Electronic position transducer
(RWG 1001/RWG 2002) or
inductive position transmitter
(IWG 1002/ IWG 1003).

SE

: Setting nominal value

: Reference input

XR

: Input value at controller

YR

: Output value at electronic


positioner

MUSAR :

16

Actuators for Regulating Duty


Description of Electronic Units
Sensor for Actuator

Technical Data

A potentiometer is used as sensor for actuator.


Single turn wire wound potentiometer with
4.7 k ohms with linearity of + 0.5 % is available
for this purpose. It is available in single or
tandem version.

Resistance

4.7 k ohms + 0.5 %

Power rating

3 Watt at 40 C

Angle of rotation

275 + 5

Linearity

+ 0.5%

Electronic position transducer RWG 1001


This device is a signal converter for the
transformation of resistance value into
proportionate current signal. It can also be
placed in the actuator where the position
determined by the potentiometer is converted
into 4-20 mA current signal.
As position transmitter, preferably a
potentiometer of 4.7 k ohm should be used so
that the reference voltage source is not over
loaded. This device requires 24V DC power
supply regulated within + 15%. Auma power
supply unit PS01 is recommended for this
purpose. RWG 1001 is a 3 wire system and is
having linearity of 0.05 %.
Electronic position transducer RWG 2002
This is basically same as RWG 1001, however
with 2 wire system. The linearity is less than 1%.

RWG 2002

RWG 1001
Technical Data - RWG 1001
Configuration
3 Wire
24V DC
Supply Voltage
min. 18, max. 33V
0-20 mA
Output Current
(4-20 mA)
Input resistance
150 k ohms
Displacement of zero
+ 25%
position, max.
Displacement of end
from 50 to 100%
position, max.
Influence of supply
Max. 0.2%
voltage variation
Temp. drift
0.2% 10o C
Linearity not considering
0.05%
potentiometer
Technical Data - RWG 2002
Configuration
2 Wire
24V DC
Supply Voltage
min. 18, max. 33V
Output Current
4-20 mA
Input resistance
150 k ohms
Displacement of zero
+ 25%
position, max.
Displacement of end
from 60 to 100%
position, max.
Influence of supply
Max. 0.15%
voltage variation
Linearity not considering
< 1%
potentiometer
17

Actuators for Regulating Duty


Description of Electronic Units
Dual Output Position Transmitter RWG 2002 DG :
It is a signal converter device for the
transformation of resistance value into
proportionate galvanically isolated two current
outputs. This device requires 24 V DC power
supply regulated within + 10%. Auma power
supply unit PS01 is recommended for
this purpose.

Technical Data - RWG 2002 DG


24V DC
Supply Voltage
+ 10% regulated
Output 1 (Isolated)
0/4-20 mA
Output 2 (Isolated)
0/4-20 mA
Current Drawn
100 mA
Adjustability of Span
+ 50%
Adjustability of Zero
+ 25%
Change in Output due to
< 0.2%
Input Supply Variation
Operating Temperature
o
o
- 20 C to + 80 C
Range
Linearity Error for both
< 1%
Outputs

Inductive Position Transmitter IWG 1002


When using Auma actuators for regulating duty
with demand of high accuracy, an inductive
position transmitter can be fitted to give precise
read out of position.
The output signal is used as feed back to
electronic positioner or for position indicator.
The system consists of two parts, a linear
variable differential transformer (LVDT) and
an electronic unit. The smallest change of
magnetic core in the measuring coil is
transformed into proportional signal. The
transmitter has no moving contacts. This device
requires 24 V DC power supply regulated
within + 15%. Auma power supply
unit PS01 is recommended for this purpose.
The linearity of the unit is less than 0.3%.

IWG 1002
Technical Data - IWG 1002
Configuration
2 Wire
24V DC
Supply Voltage
+ 15% regulated
Output Current
4-20 mA
Resistance max.
600 ohms
Displacement of zero
position, max.

+ 25%

Displacement of end
position, max.

60 to 100%

Temp. drift
Linearity (not
considering LVDT)
18

0.4% / 10o C
< 0.3%

Actuators for Regulating Duty


Description of Electronic Units
Inductive position transmitter IWG 1003
IWG 1003 is similar to IWG 1002 however with
3 wire system.

Technical Data - IWG 1003


Configuration
3 Wire
24V DC
Supply Voltage
+ 15% regulated
Output Current
0 / 4-20 mA
Resistance max.

IWG 1003

Displacement of zero
position, max.
Displacement of end
position, max.
Temp. drift
Linearity (not
considering LVDT)

600 ohms
+ 25%
60 to 100%
0.4% / 10oC
< 0.3%

Electronic Positioner CU01


The electronic positioner CU01 is designed as a
three level positioner for regulating of actuator.
By comparing two input signals (reference
signal W & regulating signal X), the positioner
determines the difference. In case this exceeds a
certain value, the actuator is switched on by
relays. The direction of rotation (opening or

closing) depends upon the plus or minus sign of


the deviation. Thus the regulating signal
generated by potentiometer or LVDT changes &
when the regulating signal & reference signal
become equal, the actuator stops as long as no
new correction is required.

Technical Data
Input WE1
XE2
Time delay
Adjustment of zero
point
Adjustment of end
position
Sensitivity (dead
band)
Relay output (max.
resistive load

0-20 mA (4-20 mA)


0-20 mA (4-20 mA)
or 0-Uref
0.5-15 secs.
0 - 20%
60 to 100%
1% - 2.5%
230V, 10A

CU 01

19

Actuators for Regulating Duty


Description of Electronic Units
Signal Isolator
Auma signal isolators are available in various
versions :
Power supply conditions :
230V AC, 110V AC or 24V DC
Various input signals :
4-20 mA or 1-5 V

Various output signals :


4-20 mA single or dual or 4-20 mA & 1-5V
Isolation is provided between input and output
and between two outputs.
Technical Data
Power Supply
Input
Output
Accuracy
Zero & span
adjustment

230V AC + 15%
110V AC + 15%
24V DC + 1V
4-20 mA
1-5V
4-20 mA single
4-20 mA dual
4-20 mA & 1-5 V
+ 0.1% of output span
+ 2% min. at zero
+ 10% min. at span

Signal Isolator

Power supply unit PS01


This unit gives 24V DC power supply for
regulating system (example : for CU01) & for
remote position indication (example : by a
voltmeter suitably calibrated). There are two
versions available:
Version I : For regulating application with
CU01 :
The output voltage Uo & Uc require no trimming
potentiometer. The voltage Uc is diverted from
voltage Uo, thus Uc can serve as common
reference potential for whole regulating system.
This version is suitable for IWG 1003 or
RWG 1001.
Supply voltage to PS01 is 220V or 110V +
15%, 50 Hz
The maximum output voltage is
Uo = 24V + 1 V DC
Uc = 5.5V + 0.5V DC

Version I
20

Version II : For remote position indication with


potentiometer 220 ohms as position transmitter :
In this two additional potentiometers P1 and P2
are provided for positions zero and maximum.

Version II
Technical Data - PS01
Supply voltage and
frequency

220V or 115V (+ 15%)


50 Hz or 60 Hz

Power drawn

9 VA

Output voltage
max.

24V +1V DC

Mounting

Snap on type for DIN


rail 46277

Actuator Types
Auma Norm Actuators
This actuator offers a complete actuator type SA
with electric motor, torque switch for open close direction, limit switches for both end
positions & blinker switch for running
indication. The required reversing contactor
should be installed separately & wired to the
motor. For signalization of the switching and to
trip the contactors over micro switches, control
wires are required from actuator terminal
compartment cover to reversing contactor
installed separately.
Auma Norm
Auma Integral Starter Actuators
The purpose of offering Integral motor controls
for the actuator is to enable the customer to save
high installation costs for external controls.
Actuators with integral controls include control
& switching elements and are supplied
ready for use.
All electrical components such as limit, torque,
thermo switches, all monitoring elements &
position transmitter are integrated into modern
controls.This results in following simplification.
- No extensive wiring in the external control
cabinet

- Several actuators can be connected to common


supply cable using isolating switch for each
actuator.
- Actuator signals are processed in the controls,
only feed back to process control system is
necessary.
- Integral starter housing can be easily
exchanged due to multi pin plug connector
between actuator & integral starter unit.
- Actuator can be operated from Local or
Remote position by means of selector switch
on the integral starter unit.

Auma Integral Starter

21

Actuator Types
Control Versions of Integral Starter Units
Auma Compact
This is a simpler version of Integral Starter Unit
with selector switch & push buttons. The
selector switch has 3 positions :
LOCAL :
The actuator can be operated locally i.e. at the
actuator by push buttons OPEN-OFF-CLOSE.
The running direction is indicated by LEDs.
REMOTE :
The actuator can be operated from remote
control station. The running direction is
indicated by LEDs on the actuator.
OFF :
The actuator cannot be operated with local
controls or from remote.

Auma compact is available as Norm or


Regulating duty actuator. Depending upon Norm
or Regulating duty, following features /
optionals are available :
Reversing contactors
Selector switch
Push buttons & indicating lamps
Thermal overload relay
Power supply unit PS01 for 24 V DC output
Electronic positioner CU01
Electronic position transducer RWG / IWG
Phase discriminator
Signal isolator
DC relay for remote operation
Remote annunciation relay for supply
indication
Multi pin connector can be provided between
actuator and compact and between compact &
terminals for customer connections.

The selector switch can be locked in any position


with pad lock. The compact unit is completely
wired with reversing contactors and no
additional control box is required.

Auma Compact

22