55. Distortion of anchor bolts and excessive cracking of the concrete structures in which
the anchor bolts are embedded may be indications of:
Over pressure up lift condition.
56. Guidance for evaluation of an existing external floating roof shall be based on criteria
in:
API 650 appendix C.
57. The recommended procedure for accessing the risk of failure due to brittle fracture is
based on:
A decision tree analysis and appropriate factors.
58. Penetrations installed using insert plates shall have the butt-weld examined by means
of:
Full radiograph.
59. Certification that the tank has been reconstructed in accordance with API 653 is
normally done by:
Reconstruction organization.
60. All the following must be included in a general inspection report except:
Operating history of the tank.
61. Who has the ultimate responsibility for complying with the provisions of API 653?
Owner / Operator.