FLUORESCENT LAMP WIRING

Aim
To wire up a fluorescent lamp as per the wiring diagram.
Materials Required
Sr.
No
1
2
3
4
5

Materials
Tube frame with holder
Fluorescent lamp
Starter
Choke
Connecting wire

FLUORESCENT LAMP

Specification

quantity

250V,40W
250V,40W
250V,40W

1
1
1
1
100cm

Procedure
1
2
3
4
5
6

Draw the wiring diagram and lay out and get them approved by staff in charge.
Prepare the list of tools and materials required for the work and collect them.
Cut the conduit into required length and draw wires of respective color through the
conduit.
The magnetic or electronic choke is filled in the frame of tube set and connections are
made as per the wiring diagram.
In case of magnetic choke o glow type starter is also used. Thus the circuit is completed
by connecting it to ac supply.
Verify the connections and switch on the supply for testing.

Result
Wired up a fluorescent lamp and the circuit was tested.