Professional Documents
Culture Documents
SYMBOL
S3
THREE-WAY SWITCH
S4
FOUR-WAY SWITCH
SP
S WP
S WPL
SK
DESCRIPTION
Sa
TRANSFORMER
30AR
NF
30AR
20AF
FUSED DISCONNECT
# OF POLES
30/3
0 3R
S LV
SF
FAN SWITCH
DIMMER SWITCH
(1500 WATTS UNLESS OTHERWISE INDICATED)
UP
DN
EWC
WP
TS
SPRINKLER TAMPER
SWITCH CONNECTION
FS
SPRINKLER WATERFLOW
SWITCH CONNECTION
SURGE SUPRESSOR
C3 = SERVICE ENTRANCE DEVICE
B3 = DISTRIBUTION BOARD DEVICE
A3 = PANELBOARD DEVICE
ST
D. ALL CLEARANCES BETWEEN OUTLET BOX AND GYPSUM BOARD SHALL BE COMPLETELY
FILLED WITH JOINT COMPOUND (OR OTHER APPROVED MATERIAL).
E. PROVIDE A WALL AROUND OUTLETS LARGER THAN 16 SQUARE INCHES. THE INTEGRITY OF THE
WALL RATING SHALL BE MAINTAINED.
F. THE TOTAL AGGREGATE SURFACE AREA OF THE BOXES SHALL NOT EXCEED 100
SQUARE INCHES PER 100 SQUARE FEET.
G. OUTLET BOXES LOCATED ON OPPOSITE SIDES OF FIRE RESISTIVE ASSEMBLIES SHALL BE
SEPARATED BY A MINIMUM HORIZONTAL DISTANCE OF 24 INCHES.
H. OUTLET BOXES SHALL BE SECURELY FASTENED TO WALL FRAMING MEMBERS.
I. THE OPENING IN THE GYPSUM BOARD FACING SHALL BE CUT NOT TO EXCEED 1/8 INCH
BETWEEN THE EDGES OF THE OUTLET BOX AND THE EDGES OF THE OPENING.
5.
6.
ALL RECEPTACLES SHALL BE MOUNTED SUCH THAT THE GROUND PIN IS MOUNTED UP.
7.
8.
ALL PANELS IN THIS PROJECT SHALL BE PROVIDED WITH A TYPE WRITTEN DIRECTORY.
DESCRIPTION
MANUFACTURER
MODEL
VOLTAGE
TYPE
LAMP
QUANTITY
A1
A1E
FAIL-SAFE
FAIL-SAFE
FSR-SC-X-24-4-LD3-3-STD-40-UNV-80/97-ED1C
FSR-SC-X-24-4-LD3-3-STD-40-UNV-80/97-ED1C-EBP
277 V
277 V
WITH UNIT
WITH UNIT
122 VA
122 VA
METALUX
24EN-LD1-6700-UNV-EL14-L840-CD-1
277 V
WITH UNIT
70 VA
FAIL-SAFE
FAIL-SAFE
FSR-SC-X-24-2-LD3-3-STD-40-UNV-80/97-ED1C
FSR-SC-X-24-2-LD3-3-STD-40-UNV-80/97-ED1C-EBP
277 V
277 V
WITH UNIT
WITH UNIT
77 VA
77 VA
METALUX
22EN-LD1-34-UNV-EL14-L840-CD-1
277 V
WITH UNIT
35 VA
FAIL-SAFE
FMB-X-4-5000/2500-7-40-UNV-80/97-ED-EBP
277 V
WITH UNIT
105 VA
METALUX
VT-LD2-55-DR-W-EL400-UNV-L840-CD2-WL-VT2
277 V
WITH UNIT
81 VA
METALUX
277 V
WITH UNIT
81 VA
277 V
WITH UNIT
81 VA
FAIL-SAFE
FAIL-SAFE
VT-LD2-55-DR-W-UNV-L840-CD2-WL-VT2-CHAIN/SETU
VT-LD2-55-DR-W-EL400-UNV-L840-CD2-WL-VT2-CHAI
N/SET-U
FMSLP-X-12-4-7500-7-40-UNV-80/97-ED
FMSLP-X-12-4-7500-7-40-UNV-80/97-ED-EBP
277 V
277 V
WITH UNIT
WITH UNIT
105 VA
105 VA
FAIL-SAFE
FHL-7L-50-3A-UNV-TL
277 V
WITH UNIT
36 VA
FAIL-SAFE
FHL-7L-50-3A-UNV-TL-EBP
277 V
WITH UNIT
94 VA
LUMARK
XTORA9A-WG-XTORMX
277 V
WITH UNIT
86 VA
FAIL-SAFE
EXL-7-*-RW-*-*
277 V
LED
PROVIDED
WITH FIXTURE
A2E
B1
B1E
B2E
FAAP
D1E
E
D3
D3E
FIXTURE DESIGNATION
FLUORESCENT FIXTURE
a
CI
GE
CII
S1
X
TEE SPLICE
CIRCUIT NUMBER
BONDING PLATE
FLUORESCENT FIXTURE
DIAGONAL SHADING DENOTES HALF OF LAMPS
CONNECTED TO CRITICAL BRANCH, OTHER HALF
TO NORMAL BRANCH. (3 LAMP FIXTURES SHALL
HAVE 2 LAMPS CONNECTED TO CRITICAL,
1 LAMP CONNECTED TO NORMAL).
FLUORESCENT FIXTURE
COMPLETELY SHADED DENOTES LIGHT
FIXTURE CONNECTED TO LIFE SAFETY BRANCH
CIRCUIT.
F
FE
G
METALUX
LOAD
COMMENTS
SEAL
PRELIMINARY DOCUMENTS
NOT FOR CONSTRUCTION
1. SHADED FIXTURES IN PLAN VIEW ARE EMERGENCY LIGHTING FIXTURES PROVIDED WITH AN EMERGENCY BATTERY BACK-UP SOURCE.
2. VERIFY COLOR/FINISH OF ALL FIXTURES WITH THE ARCHITECT.
3. SINGLE FIXTURE LISTED IN SCHEDULE. ALL EQUIVALENT FIXTURES SHALL MEET OR EXCEED THE PERFORMANCE OF FIXTURES LISTED IN LIGHTING FIXTURE SCHEDULE.
GROUND TERMINAL
BONDING CONDUCTOR
GROUND BAR
DN
DOWN CONDUCTOR
COUNTERPOISE CONDUCTOR
FLUORESCENT FIXTURE
HALF SHADING DENOTES HALF OF LAMPS CONNECTED
TO LIFE SAFETY BRANCH, OTHER HALF TO NORMAL
BRANCH. (3 LAMP FIXTURES SHALL HAVE 2 LAMPS
CONNECTED TO LIFE SAFETY, 1 LAMP
CONNECTED TO NORMAL).
KEY PLAN
P
F
DN
SCALE
NOT TO SCALE
EDH-X
DUPLEX RECEPTACLE
LIGHTING
A
JUNCTION BOX
C3
FACP
CABLE TRAY
SS
CONDUIT TURNING UP
4.
COMBINATION AUDIBLE/VISUAL
NOTIFICATION DEVICE
C = CEILING-MOUNTED
CD = CANDELA RATING
NEW
FUTURE
XXCD
CLOCK RECEPTACLE
GND
EXISTING TO REMAIN
NOTE:
TICK MARKS SHOWN ON ANY DEVICE REPRESENTS
RECEPTACLE CONNECTED TO THE EMERGENCY CIRCUIT
(RED DEVICE) TYPICAL FOR ANY DEVICE IN LEGEND
EXISTING TO BE REMOVED
FLEXIBLE CONDUIT
IG
RT
FATC
CONDUIT CONTINUED
THE EXCLUSIVELY DEDICATED SPACE EXTENDING FROM FLOOR TO STRUCTURAL CEILING WITH
A WIDTH AND DEPTH OF THE PANELBOARD OR SWITCHBOARD MUST BE CLEAR OF ALL PIPING,
DUCTS, EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITECTURAL
APPURTENANCES IN ACCORDANCE WITH NEC 408.
CONDUIT STUB
B.
A. WORKING CLEARANCES FOR ELECTRICAL EQUIPMENT SHALL BE IN COMPLIANCE WITH NEC 110.
EQUIPMENT SHALL BE OF MATERIALS SUITABLE FOR AND RATED FOR THE ENVIRONMENT IN WHICH
THEY ARE TO BE INSTALLED.
EQ
3.
RECEPTACLES SHALL BE LOCATED 18 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF DEVICE,
UNLESS OTHERWISE NOTED. ABOVE COUNTER RECEPTACLES SHALL BE MOUNTED 6" ABOVE BACK
SPLASH TO CENTERLINE OF DEVICE.
R = RETURN
S = SUPPLY
2.
LIGHT SWITCHES SHALL BE MOUNTED 48 INCHES ABOVE FINISHED FLOOR TO CENTER LINE OF
DEVICE, UNLESS OTHERWISE NOTED.
SP
XXCD
DUPLEX RECEPTACLE
DESCRIPTION
1.
S MP
SL
SYMBOL
MCP
SIZE
GENERAL NOTES:
DESCRIPTION
BASIC MATERIALS
Pinellas County
VFD
DDC
NOTE: SOME SYMBOLS SHOWN ON THIS LEGEND MAY NOT PERTAIN TO THIS PROJECT.
No.
Description
Date
REVISIONS
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
ELECTRICAL
SYMBOL LEGEND
A
PROJECT NO.
E-000
SHEET NO.
50057109
1
ELECTRICAL KEY NOTES
KEYNOTE TEXT
#
1
2
3
4
5
6
F
7
GENERAL NOTES:
CR
OS
SB
AYO
U
VT
MH
2
VT
VT
2
MH
VT
T
T
"B"
PROPOSED NEW DUKE
ENERGY PRIMARY
SERVICE
"M1"
(HEALTH)
MH
145TH AVE N
"A"
SHERIFF ADMIN.
2
8
Pinellas County
SAFE HARBOR
PB
"C"
"M2"
SEAL
5
T
PRELIMINARY DOCUMENTS
VT
T
T
PB
VT
142ND AVE N
(CENTRAL)
PB
CENTRAL DIVISION
PB
PB
PB
POND
POND
EXISTING PRIMARY-SIDE,
MEDIUM VOLTAGE,
UNDERGROUND
FEEDERS. TYPICAL.
T
T
SOUTH DIVISION
(CJC)
("A" SOUTH)
49TH ST N
KEY PLAN
SCALE
PINELLAS COUNTY
CRIMINAL COURT
COMPLEX
1" = 100'-0"
"G"
POND
POND
VT
"F"
MAINTENANCE
"E"
"D"
"C"
(SA)
T
VT
No.
Description
Date
REVISIONS
T
SIR LB021
(FI R 1/2" LB1344 0.30' S., 0.50' W.)
VT
OHE
LAND LINE
JURISDICT IONAL WET
("F" SOUTH)
OHE
OHE
VT
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
ELECTRICAL SITE
PLAN
A
PROJECT NO.
E-001
50057109
1
#
1
2
1.1
6.9
WP
WP
A
J
A.1
A.1
7
4
BULK DRY
STORAGE
108
PROGRAM
MEETING ROOM
116
PROGRAM
MEETING ROOM
110
TV
WORKER
STAGING
122
WP
7
TV
LOADING
DOCK
105
INMATE
TOILET
121
WP
COILING DOOR #2
5
SEARCH
123
STORAGE
10
J J
10
SECURITY
ELECTRONICS
101
VAV BOX
SALLYPORT
SERVICE DRIVE
103
DOCK
FAN COILSTORAGE
UNIT
102
BULK REFIG
2 STORAGE
109
JANITOR
142
STORAGE
112
OFFICE
115
VAV BOX
INMATE
TOILET
113
AV CLOSET
117
JANITOR
114
VAV BOX
STAFF
118
STAIR
A
SA1
COILING DOOR #1
5
CORRIDOR
141
4
FEC
FEC
C
ELEVATOR
A
EA
OFFICE/
CONTROL
137
1
WP
WATER
HEATER
124
CART
WASH
139
ELECTRICAL
140
WP
WP
VAV BOX
WP
ELEVATOR
B 1
E-141
EB
WP
5
WP
STAIR
B
SB1
ELEVATOR
C
6
EC
GENERAL NOTES:
WP
WP
WP
INMATE
TOILET
119
VAV BOX
VAV BOX
WP
TV
DOCK
STAGING
107
PROGRAM
MEETING ROOM
111
F
WP
L104
L109B
L109A
L116
L108B
L101
WP
STAFF
TOILET
125
L108A
GARBAGE/
RECYCLE DOCK
106
Pinellas County
AIR
COMPRESSOR
126
4
WP
TRASH COMPACTOR
L115
SEAL
4
CLEAN LAUNDRY
STORAGE
135
TRASH COMPACTOR
WP
4
CENTRAL
LAUNDRY
138
PRELIMINARY DOCUMENTS
L111A
L111B
D
KEY PLAN
L111C
BEDDING
STORAGE
134
WP
PARKING AREA
VAV BOX
4
DRYERS
127
L111D
5
4
WATER TANK
STORAGE
104
L111E
MAINTENANCE
SUPPLY
133
SCALE
4
L111F
VAV BOX
1/8" = 1'-0"
4
RISER
ROOM
132
5
UNIFORM
STORAGE
131
INMATE
TOILET
129
BREAK
ROOM
130
CHEMICAL
STORAGE
128
E.9
L111G
L114A
L114B
4
L111H
4
2448
2448
E.9
WP
1.1
6.9
No.
Description
Date
REVISIONS
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
FIRST FLOOR
POWER PLAN
A
PROJECT NO.
E-110
SHEET NO.
50057109
1
GENERAL NOTES:
1.1
6.9
F
S1
S1
S1
A
S1
GE
FE
GE
A1E
GE
GE
G
BULK DRY
STORAGE
108
GE
FE
GE
A1E
A1
A1
GE
GE
A1
GE
GE
A1
A1E
A1
A1E
GE
SEARCH
B1 123
A1E
A1
A1E
A1
A1E
GE
GE
FE
S1
DOCK
STORAGE
102
JANITOR
114 B1
FE
FE
STORAGE
112
F
BULK REFIG
STORAGE
109
GE
GE
A1E
115
A2E
B1E
A1E
A1
A1E
GE
GE
GE
A1
D1E
S1
CE
A1E
GE
GE
A2E
A1E
A1
CART
WASH
139
FE
ELECTRICAL
140
D3E
D1E
ELEVATOR
B
EB
D1E
D1E
ELEVATOR
C
D1E
EC
GE
GE
GE
GE
GARBAGE/
RECYCLE DOCK
106
GE
UTILITY
WASH
136
FE
S1
C
CE
GE
FE
TRASH COMPACTOR
STAFF
TOILET
125
FE
GE
CE
B1
WATER
FE
HEATER
X
GE
FEC
STAIR
B
SB1
A1E
S1
A1E
D3E
OFFICE/
CONTROL
A2E 137 A2E
A1
A1
A1E
A1
D1E
A1E
A1
FEC
A1E
ELEVATOR
A
EA
A1E
CORRIDOR
141
A2E
A1E
A1
CE
A1E
INMATE
TOILET
119
F
STAFF
TOILET
118
B1E
A1
FE
FE
A1
FE
AV CLOSET
A2E
FE
CE
STAIR
A
SA1
A1E
FE
FE
A1
FE
STORAGE
A1E
FE
SALLYPORT
SERVICE DRIVE
103
B1
121
B1
G
A1
INMATE
FE
A1
A1
B
GE
S1
A1E
111
GE
D3E
A1E
DOCK
STAGING
107
A1E
A1E
A1
WORKER
STAGING
122
A1
A1E
FE
SECURITY
ELECTRONICS
101
A.1
A1
PROGRAM
MEETING ROOM
116
PROGRAM
MEETING ROOM
110
LOADING
DOCK
105
S1
A1E
A1E
GE
GE
GE
AIR
COMPRESSOR
126
GE
GE
S1
A1
A1
A1E
A1
GE
A1E
F
G
GE
A1E
GE
GE
A1
Pinellas County
A.1
S1
CE
SEAL
D3E
GE
GE
FE
GE
CLEAN
LAUNDRY
F
FE
STORAGE
135
S1
GE
GE
GE
PRELIMINARY DOCUMENTS
CENTRAL
LAUNDRY
138
D3
S1
D
KEY PLAN
GE
GE
GE
FE
FE
GE
GE
GE
BEDDING
STORAGE
134
PARKING AREA
D3E
DRYERS
127
D3
GE
GE
WATER TANK
STORAGE
104
FE
F
F
MAINTENANCE
SUPPLY
133
FE
GE
GE
GE
GE
SCALE
D3
GE
GE
1/8" = 1'-0"
D3E
RISER
ROOM
132
GE
FE
UNIFORM
STORAGE
131
FE
D3E
S1
INMATE
FE
TOILET
CHEMICAL
STORAGE
128
FE
G
D3E
E.9
E.9
FE
BREAK
ROOM
130
2448
S1
2448
F
S1
S1
S1
1.1
6.9
No.
Description
Date
REVISIONS
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
FIRST FLOOR
LIGHTING PLAN
A
PROJECT NO.
E-111
SHEET NO.
50057109
1
#
1
1.1
6.9
A
F
A.1
A.1
WP
PROGRAM
MEETING ROOM
116
PROGRAM
MEETING ROOM
110
GENERAL NOTES:
1. ALL NOTIFICATION DEVICES SHALL HAVE A LUMINOUS
INTENSITY OF 75 CANDELA UNLESS OTHERWISE NOTED.
WORKER
STAGING
122
BULK DRY
STORAGE
108
LOADING
DOCK
105
INMATE
TOILET
121
PROGRAM
MEETING ROOM
111
DOCK
STAGING
107
F
AV CLOSET
117
WP
STAFF
TOILET
118
F
F
F
STAIR
A
SA1
WP
CORRIDOR
141
FEC
TS
INMATE
TOILET
113
FS TS
WP
JANITOR
142
BULK REFIG
STORAGE
109
INMATE
TOILET
119
DOCK
STORAGE
102
SALLYPORT
SERVICE DRIVE
103
SECURITY
ELECTRONICS
101
OFFICE
115
STORAGE
112
Pinellas County
JANITOR
114
TS
1
E
FEC
TS
WATER
HEATER
124
ELEVATOR
A
EA
H
3
CART
WASH
139
OFFICE/
CONTROL
137
WP
WP
ELECTRICAL
140
H
2
ELEVATOR
B
EB
H
2
STAIR
B
SB1
ELEVATOR
C
EC
C
E
WP
STAFF
TOILET
125
AIR
COMPRESSOR
126
GARBAGE/
RECYCLE DOCK
106
UTILITY
WASH
136
TRASH COMPACTOR
WP
STORAGE
120
WP/110cd
SEARCH
123
SEAL
F WP
CLEAN LAUNDRY
STORAGE
135
PRELIMINARY DOCUMENTS
WP
F
110cd
110cd
CENTRAL
LAUNDRY
138
KEY PLAN
BEDDING
STORAGE
134
WP
PARKING AREA
WATER TANK
STORAGE
104
DRYERS
127
MAINTENANCE
SUPPLY
133
SCALE
1/8" = 1'-0"
RISER
ROOM
132
INMATE
TOILET
129
BREAK
ROOM
130
FS
TS
CHEMICAL
STORAGE
128
E.9
UNIFORM
STORAGE
131
2448
2448
E.9
1.1
6.9
No.
Description
Date
REVISIONS
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
FIRST FLOOR
FIRE ALARM &
MISC. SYSTEMS
PLAN
PROJECT NO.
E-112
SHEET NO.
50057109
1
ELECTRICAL KEY NOTES
KEYNOTE TEXT
#
1
1.1
6.9
GENERAL NOTES:
A.1
A.1
CHEMICAL STORAGE
(SECURE)
216
DRY FOOD
STORAGE
204
SECURED
STORAGE
209
BREAK
ROOM
211
WARE WASH
AREA
215
WP
WP
K209
K208.1
CORRIDOR
212
STORAGE/
FUTURE LINK
217
1
1
H
H
K329F
UNIFORM
205
WP
K329G
FOOD SERVICE
MGMT OFFICE
214
K329M
K329H
K329J
K329I
STAIR
A
SA2
FEC
DAIRY
COLDROOM
247
K101.2
K316B
1
C1
K102.4B
12"X12"
1075 CFM
.27" S.P.
G G
9"X8"
538 CFM
.07" S.P.
C
C
#321.2L
G
G
G G
12"X12"
937 CFM
.27" S.P.
12"X12"
937 CFM
.27" S.P.
CORRIDOR
229
STAFF
TOILET
226
TV
DAILY DRY
STORAGE
236
A/V
CLOSET
224
K306
K307
E.9
C
K311B
K102.10B
REF
K305
FINISH VEG
PREP
237
1
1
1
MIC MIC
FINISH MEAT
PREP
238
1
1
E.9
F
K309D
K308
K311A
CONNECTOR TO
CENTRAL TOWER
CN
1.1
1/8" = 1'-0"
REFER TO PARTIAL
PLAN ON SHEET E-140.
REF
H
H
SCALE
-10 FREEZER
239
MULTI-PURPOSE
223
K102.11B
-20 FREEZER
240
KEY PLAN
STAFF
TOILET
227
K302
K102.9B
K102.10A
K309C
1
12"X12"
937 CFM
.27" S.P.
K321.2
K101.9
K102.11A
JAN
228
12"X10"
1353 CFM
.43" S.STEAM
P.
SAFET Y VA LVE
1/ 2" N PT
SATE
12"X10"CO N DEN
RETU RN
1352 CFM
.43" S.P.
FIRE CABINET
K102.9A
PRELIMINARY DOCUMENTS
K417
K322C
K101.8
K420
K415
K419
SEAL
K402
K322B
TV
K416
K309A
K321.1
1
1
K322A
1
STEAM
CO N TRO L
VALVE
1/ 2" N PT
CO N DEN SATE
RETU RN
11"X8"
1012 CFM
.29" S.P.
11"X8"
1011 CFM
.29" S.P.
12"X10"
809 CFM
.20" S.P.
K321.3
#321.1R
241
K327A
THAW/PULL
K102.7A
K102.7B
SAFET Y VA LVE
12"X10"
809 CFM
.20" S.P.
C D
K101.7
BULK
COLDROOM
242
G G
K102.8B
K319
1
#321.2R
SAFET Y VA LVE
1/ 2" N PT
SAFET Y VA LVE
1/ 2" N PT
SAFET Y VA LVE
K318A
K102.8A
1
1/ 2" N PT
CO N DEN SATE
RETU RN STEAM
CO N TRO L
VALVE
#321.1L
K403
STEAM
CO N TRO L
VALVE
CO N DEN SATE
12"
X9"
RETU RN
1216 CFM
.37" S.P.
K318B
K404
1
K326J
K323B
12"X10"
1379 CFM
.42" S.P.
12"X12"
937 CFM
.27" S.P.
K101.6
FINISHED BULK
COLDROOM
243
1
1
K326I
K327B
K326H
SERVING
231
K414
SATE
12"X9"CO N DEN
RETU RN
1217 CFM
STEAM
.37" S.P.
CO N TRO L
K315
1
1
K309B
K326F
FOOD PREP
SERVICE AREA
230
STEAM
CO N TRO L
VALVE
K326G
K413
1
1
J
FIRE CABINET
1
1
CORRIDOR
222
K101.5
K102.6B
K326E
K326D
STAFF DINING
MULTI-PURPOSE
232
K102.6A
1
1
K323A
K407
K326B
K326C
K412B
12"X11"
1648 CFM
.47" S.P.
K409
K326A
K101.3
BULK MEAT
COLDROOM
242
K102.5B
HOT FOOD
1
PRODUCTION
235
K412A
K216.2B
12"X12"
937 CFM
.27" S.P.
K102.5A
1
K329A
1CORRIDOR
251
FINISH PRODUCE
COLDROOM
1
1
245
H C
K329B
D1
#321.6R
E1
E2
G
D1
K411
K216.2A
#321.6L
E1
E2
G
K101.4
12"X10"
1456 CFM
.39" S.P.
K102.4A
K101.1
D2
C1
K316A
D2
BULK PRODUCE
COLDROOM
248
ELEC
233
STAIR
B
SB2
ELEVATOR
C
EC
ELEVATOR
B 2
EBE-141
ICE/BEV.
234
ELEVATOR
A
EA
VALVE
TRASH
HOLDING
246
K329K
K102.3B
JAN
249
STORAGE
218
CORRIDOR
221
CO N DEN SATE
TRAP AN D ST RAI N ER
K102.3A
K329L
CORRIDOR
250
FEC
CART STORAGE
AND WASHING
219
STAFF
TOILET
206
TRAY
MAKE-UP
220
INMATE
TOILET
207
K329E
OFFICE
213
Pinellas County
EQUIPMENT
STORAGE
203
JAN/EQUIP
SUPPLIES
202
K329D
KITCHEN/LAUNDRY
STORAGE
201
K329C
INMATE
TOILET
208
CORRIDOR
210
6.9
No.
Description
Date
REVISIONS
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
SECOND FLOOR
POWER PLAN
A
PROJECT NO.
E-120
SHEET NO.
50057109
1
GENERAL NOTES:
1.1
6.9
A.1
FE
FE
FE
DRY FOOD
STORAGE
204
FE
FE
FE
FE
A
C
FE
FE
FE
FE
A.1
CHEMICAL STORAGE
(SECURE)
216
SECURED
STORAGE
209
FE
BREAK
ROOM
211
FE
F
F
FE
FE
FE
WARE WASH
AREA
215
FE
X
FE
FE
B1E
EQUIPMENT
STORAGE
203
FE
A1E
A2E
A2E
UNIFORM
205
FE
STAFF
TOILET
206
FE
A1
B2E
A2E
FE
FE
FTRAY
MAKE-UP
220
FE
FE
FE
FOOD SERVICE
MGMT OFFICE
214
A2E
A2E
FE
B2E
FE
B2E
FE
CART STORAGE
AND WASHING
219
FE
STORAGE
218
FE
B2E
STAIR
A
SA2
FE
A1E
A1
A1E
A1
A1E
A1
A1E
A1
A1E
A1
A1E
A1
A1
A1
CORRIDOR
221
A1E
A1E
FEC
GE
DAIRY
COLDROOM
247
FE
FE
F
ICE/BEV.
234
ELEVATOR
A
EA
ELEVATOR
B
EB
ELEC
233
D3E
JAN
249
CE
D3E
FE
TRASH
HOLDING
246
FEC
FE
A1E
ELEVATOR
C
EC
STAIR
B
SB2
X
B1
FE
FE
F
A1E
FE
A1
A2E
FE
INMATE
TOILET
207
FE
JAN/EQUIP
SUPPLIES
202
FE
B1
STORAGE/
FUTURE LINK
217
KITCHEN/LAUNDRY
STORAGE
201
FE
CORRIDOR
212
CORRIDOR
B1
210
INMATE
TOILET
208
D2
CE
BULK PRODUCE
COLDROOM
248
E1
E2
D2
C1
FE
C1
FE
FE
X
E1
E2
A1
A1E
D1
A1
G
G
FOOD PREP
SERVICE AREA
230
A1E
12"X12"
937 CFM
.27" S.P.
FE
A1E
A1
B1E
12"X12"
937 CFM
.27" S.P.
STEAM
CO N TRO L
VALVE
12"X10"
1353 CFM
.43" S.STEAM
P.
A1E
A1
FE
B1
KEY PLAN
H C
FE
A1E
FE
A1
A1
FE
12"X12"
937 CFM
.27" S.P.
FIRE CABINET
A1
FE
FE
B1
223
A1
CORRIDOR
229
STAFF
FE
A1E
A1
A1E
A1E
FE
SCALE
A1E
FE
A1E
A1E
X
228
SAFET Y VA LVE
1/ 2" N PT
SATE
12"X10"CO N DEN
RETU RN
1352 CFM
.43" S.P.
11"X8"
1011 CFM
.29" S.P.
A1
CO N DEN SATE
TRAP AN D ST RAI N ER
1/ 2" N PT
CO N DEN SATE
RETU RN
11"X8"
1012 CFM
.29" S.P.
12"X10"
809 CFM
.20" S.P.
FE
#321.1R
A1E
PRELIMINARY DOCUMENTS
THAW/PULL
241
G G
BULK
COLDROOM
242
SEAL
1/ 2" N PT
CO N DEN SATE
12"
X9"
RETU RN
1216 CFM
.37" S.P.
SAFET Y VA LVE
1/ 2" N PT
CO N DEN SATE
RETU RN STEAM
CO N TRO L
VALVE
FE
SAFET Y VA LVE
12"X10"
809 CFM
.20" S.P.
C D
A1E
STEAM
CO N TRO L
VALVE
12"X10"
1379 CFM
.42" S.P.
12"X12"
937 CFM
.27" S.P.
#321.1L
A1
VALVE
1/ 2" N PT
SAFET Y VA LVE
A1
FE
A1E
A1
FINISHED BULK
COLDROOM
243
A1
SERVING
231
9"X8"
538 CFM
.07" S.P.
FE
12"X10"
1456 CFM
.39" S.P.
CORRIDOR
222
A1E
G G
12"X12"
937 CFM
.27" S.P.
#321.2R
FE
SATE
12"X9"CO N DEN
RETU RN
1217 CFM
STEAM
.37" S.P.
CO N TRO L
SAFET Y VA LVE
A1
12"X12"
1075 CFM
.27" S.P.
G G
STEAM
CO N TRO L
VALVE
FIRE CABINET
FE
STAFF DINING
MULTI-PURPOSE
A1E
CE
A1
BULK MEAT
COLDROOM
242
A1
A1
#321.6L
GE
A1E
#321.6R
FE
FE
12"X11"
1648 CFM
.47" S.P.
CORRIDOR
251
FE
FINISH PRODUCE
COLDROOM
245
A1E
HOT FOOD
PRODUCTION
F
235
A1
G
D1
A1E
FE
FE
FE
Pinellas County
FE
A1E
FE
F
DAILY DRY
STORAGE
236
D3E
F
A/V
CLOSET
224
D3E
E.9
A1
A1E
A1
REF
FINISH VEG
PREP
237
A1
B1
A1E
A1
B1E
E.9
X
C
1/8" = 1'-0"
REFER TO PARTIAL
PLAN ON SHEET E-140.
A1E
REF
FINISH MEAT
PREP
FE
238
MIC MIC
-10 FREEZER
239
-20 FREEZER
240
F
CONNECTOR TO
CENTRAL TOWER
CN
1.1
6.9
No.
Description
Date
REVISIONS
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
SECOND FLOOR
LIGHTNG PLAN
A
PROJECT NO.
E-121
SHEET NO.
50057109
1
#
1.1
6.9
GENERAL NOTES:
1. ALL NOTIFICATION DEVICES SHALL HAVE A LUMINOUS
INTENSITY OF 75 CANDELA UNLESS OTHERWISE NOTED.
A.1
A.1
CHEMICAL STORAGE
(SECURE)
216
SECURED
STORAGE
209
DRY FOOD
STORAGE
204
WARE WASH
AREA
215
BREAK
ROOM
211
F
STORAGE/
FUTURE LINK
217
CORRIDOR
212
C/ F
75cd
F
CORRIDOR
250
CORRIDOR
221
FEC
TRASH
HOLDING
246
ELEVATOR
A
EA
ICE/BEV.
234
C/
95cd
ELEVATOR
HB
EB
ELEC
233
FEC
STAIR
B
SB2
ELEVATOR
C
EC
D2
D2
C1
C1
E
E1
E2
E1
E2
G
D1
D1
CORRIDOR
222
STEAM
CO N TRO L
VALVE
12"X12"
1075 CFM
.27" S.P.
G
G
G G
12"X12"
937 CFM
.27" S.P.
9"X8"
538 CFM
.07" S.P.
12"X10"
1456 CFM
.39" S.P.
VALVE
STEAM
CO N TRO L
VALVE
C/
95cd
12"X12"
937 CFM
.27" S.P.
PRELIMINARY DOCUMENTS
C
CO N DEN SATE
TRAP AN D ST RAI N ER
SAFET Y VA LVE
JAN
228
12"X12"
937 CFM
.27" S.P.
#321.2L
STEAM
CO N TRO L
VALVE
SAFET Y VA LVE
1/ 2" N PT
CO N DEN SATE
RETU RN
11"X8"
1012 CFM
.29" S.P.
12"X10"
1353 CFM
.43" S.P.
STEAM
12"X10"
809 CFM
.20" S.P.
1/ 2" N PT
CO N DEN SATE
RETU RN STEAM
CO N TRO L
VALVE
#321.1L
SAFET Y VA LVE
1/ 2" N PT
CO N DEN SATE
12"
X9"
RETU RN
1216 CFM
.37" S.P.
12"X12"
937 CFM
.27" S.P.
12"X10"
1379 CFM
.42" S.P.
SAFET Y VA LVE
1/ 2" N PT
SATE
12"X9"CO N DEN
RETU RN
1217 CFM
STEAM
.37" S.P.
CO N TRO L
SAFET Y VA LVE
#321.2R
FIRE CABINET
C D
SEAL
R
FINISHED BULK
COLDROOM
243
C/
95cd
R R
SERVING
231
D
BULK MEAT
COLDROOM
242
FOOD PREP
SERVICE AREA
230
#321.6L
12"X11"
1648 CFM
.47" S.P.
G G
FINISH PRODUCE
COLDROOM
245
CORRIDOR
251
STAFF DINING
MULTI-PURPOSE
232
HOT FOOD
PRODUCTION
235
#321.6R
BULK PRODUCE
COLDROOM
248
KEY PLAN
12"X12"
937 CFM
.27" S.P.
C
D
FIRE CABINET
STAFF
TOILET
227
MULTI-PURPOSE
223
H C
1/ 2" N PT
12"X10"
809 CFM
.20" S.P.
#321.1R
SATE
12"X10"CO N DEN
RETU RN
1352 CFM
.43" S.P.
THAW/PULL
241
G G
BULK
COLDROOM
242
11"X8"
1011 CFM
.29" S.P.
DAIRY
COLDROOM
247
TS
JAN
249
STORAGE
218
CART STORAGE
AND WASHING
219
STAIR
A
SA2
STAFF
TOILET
206
FS TS
FOOD SERVICE
MGMT OFFICE
214
UNIFORM
205
Pinellas County
INMATE
TOILET
207
TRAY
MAKE-UP
220
OFFICE
F
C / 213
75cd
EQUIPMENT
STORAGE
203
JAN/EQUIP
SUPPLIES
202
KITCHEN/LAUNDRY
STORAGE
201
INMATE
TOILET
208
CORRIDOR
210
CORRIDOR
229
SCALE
F
STAFF
TOILET
226
F
FINISH CVEG
PREP
237
DAILY DRY
STORAGE
236
A/V
CLOSET
224
REF
FINISH MEAT
PREP
238
1/8" = 1'-0"
REFER TO PARTIAL
PLAN ON SHEET E-140.
REF
MIC MIC
-10 FREEZER
239
-20 FREEZER
240
E.9
E.9
C
F
CONNECTOR TO
CENTRAL TOWER
CN
1.1
6.9
No.
Description
Date
REVISIONS
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
SECOND FLOOR
FIRE ALARM &
MISC. SYSTEMS
PLAN
PROJECT NO.
E-122
SHEET NO.
50057109
1
#
1
2
1.1
6.9
CWP-2 ABS
CHWP-2 ABS
CWP-1 ABS
CHWP-1 ABS
SYSTEM PUMP
A.1
A.1
CHWPFUTURE
ABS
ELECTRIC CHILLER
CWP-2
ABS
ELECTRIC CHILLER
CHWP-2
ABS
CWP-1
ABS
CONTROL
CONFERENCE RM
313
4
CHWP-1
ABS
SYS PUMP
2
2
ELECTRIC CHILLER
2 CONTROL
ROOM
2
302
7
2
OFFICE
301
8
2
4
ABSORPTION CHILLER
RECIRC. PUMP
B
FUTURE ABSORPTION
CHILLER
STAIR
A
SA3
STAFF
TOILET
305
2 2
VESTIBULE
304
REF
3
CHW AHU
B
3
2
303
2
FAN COIL UNIT
CWP-FUTURE
WP
FUTURE CWP
4
CHWP-FUTURE
ELEVATOR
LOBBY
307
FUTURE CHWP
CWP-3
CHWP-3
CWP-2
CHWP-2
CWP-1
CHWP-1
4
FAN COIL UNIT
CWP-3
CHWP-3
CWP-2
CHWP-2
CWP-1
FEC
CHWP-1
ELEVATOR
A
EA
ELEVATOR
CONTROL
310
GENERATOR
4CONTROL
E-141309
FAN COIL UNIT
STAIR
B
SB3
I.T.
ROOM
306
ELEVATOR
C
EC
GENERAL NOTES:
REF
ELECTRIC CHILLER
FUTURE ELECTRIC
CHILLER
6
7
Pinellas County
CWPFUTURE
ABS
F
FUTURE CONDENSER
REFRIGERANT PURGE
WATER PUMP FAN
FUTURE CHWP ABSORPTION
ABSORPTION
5
E-141
COILING DOOR #3
4
4
ELECTRICAL
ROOM
312
3
E-141
WP
GENERATOR RADIATOR #1
LAUNDRY AHU
SEAL
4
GENERATOR #1
PRELIMINARY DOCUMENTS
NOT FOR CONSTRUCTION
EXTERIOR
ROOF
ER1
WP
GENERATOR
ROOM
311
EXTERIOR
ROOF
ER2
KEY PLAN
FUTURE GENERATOR
RADIATOR #2
K102
4
KITCHEN AHU
FUTURE GENERATOR #2
SCALE
4
WP
KITCHEN EQUIPMENT
CONDENSING UNIT
E.9
1/8" = 1'-0"
E.9
WP
1.1
6.9
No.
Description
Date
REVISIONS
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
THIRD FLOOR
POWER PLAN
A
PROJECT NO.
E-130
SHEET NO.
50057109
1
GENERAL NOTES:
1.1
6.9
A
GE
A.1
GE
GE
GE
GE
GE
A2E
A2E
A2E
A2E
A.1
CONTROL
CONFERENCE RM
A2E
G
GE
GE
GE
GE
GE
A2E
A2E
A2E
A2E
A2E
A2E
A2E
A2E
CONTROL
ROOM
302
A2E
A2E
REF
GE
GE
GE
GE
REF
B
G
FE
STAIR
GE
GE
GE
GE
GE
GE
STAFF
TOILET
FE
CHILLER
ROOM
308
SA3
FE
SECURITY
ELECTRONICS
303
VESTIBULE
FE
S1
X
FE
GE
GE
GE
GE
GE
GE
GE
FE
X
FE
ELEVATOR
LOBBY
307
FE
F
STAIR
B
SB3
D3E
GE
GE
D3E
GE
GE
ELECTRICAL
GE
ELEVATOR
ELEVATOR
A
EA
D3E
FEC
D3E
GE
310
GE
D3E
GENERATOR
CONTROL
309
GE
GE
GE
GE
D3E
D3E
ELEVATOR
C
EC
GE
D3E
D3E
FE
I.T.
ROOM
306
FE
D3E
GE
312
CE
GE
GE
S1
GE
GE
Pinellas County
GE
CE
S1
G
GE
GE
SEAL
GE
GE
GE
PRELIMINARY DOCUMENTS
NOT FOR CONSTRUCTION
S1
EXTERIOR
ROOF
ER1
GENERATOR
ROOM
311
S1
S1
GE
GE
GE
GE
GE
EXTERIOR
ROOF
ER2
S1
KEY PLAN
SCALE
1/8" = 1'-0"
G
E.9
GE
GE
S1
E.9
S1
1.1
6.9
No.
Description
Date
REVISIONS
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
THIRD FLOOR
LIGHTING PLAN
A
PROJECT NO.
E-131
SHEET NO.
50057109
1
#
1
2
1.1
6.9
A
110cd
A.1
F
110cd
A.1
CONTROL
CONFERENCE RM
313
GENERAL NOTES:
1. ALL NOTIFICATION DEVICES SHALL HAVE A LUMINOUS
INTENSITY OF 75 CANDELA UNLESS OTHERWISE NOTED.
CONTROL
ROOM
302
REF
OFFICE
301
4
FACP
110cd
REF
STAFF
TOILET
305
CHILLER
ROOM
308
SECURITY
ELECTRONICS
303
VESTIBULE
304
STAIR
A
SA3
Pinellas County
F
2
ELEVATOR
LOBBY
307
FS TS
2
QUANTITY: 5
STAIR
B
SB3
TS
TS
R
R
F
3
GENERATOR
CONTROL
309
I.T.
ROOM
306
ELEVATOR
C
H
EC
ELEVATOR
CONTROL
310
H
ELEVATOR
AH
EA
FEC
ELECTRICAL
ROOM
312
C
F
C/
80cd
E
3
C/
80cd
QUANTITY: 5
110cd
QUANTITY: 5
SEAL
PRELIMINARY DOCUMENTS
NOT FOR CONSTRUCTION
WP
F
WP
GENERATOR
ROOM
311
EXTERIOR
ROOF
ER1
EXTERIOR
ROOF
ER2
KEY PLAN
SCALE
1/8" = 1'-0"
E.9
F
E.9
110cd
1.1
6.9
No.
Description
Date
REVISIONS
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
THIRD FLOOR
FIRE ALARM &
MISC. SYSTEMS
PLAN
PROJECT NO.
E-132
SHEET NO.
50057109
1
#
1.1
6.9
1
2
A.1
A.1
S1
FE
FUTURE 2-CELL
COOLING TOWER
(ELECTRIC CHILLER)
S1
S1
STAIR
A
SA4
S1
FE
1
FE
1
110cd
WP
WP
WP
FE
WP
WP
WP WP
FE
2
F
WP WP
110cd
FE
S1
S1
S1
S1
S1
FE
Pinellas County
STAIR
B
SB4
FE
SEAL
GENERATOR SUPPLY FAN
GENERATOR EXHAUST
FAN
PRELIMINARY DOCUMENTS
NOT FOR CONSTRUCTION
KEY PLAN
SCALE
1/8" = 1'-0"
E.9
E.9
B
1
1.1
6.9
7
No.
Description
Date
REVISIONS
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
ROOF
ELECTRICAL PLAN
A
PROJECT NO.
E-140
SHEET NO.
50057109
1
#
LDP
L1N
ELECTRICAL
H1N
140
TL1N
2
2
2
I.T.
ROOM
306
E
2
KDP
L2KB
1
ELEC
233
1
1
TL2KB
H2NK
H2N
Pinellas County
TL2N
TL2KA
L2KA
A1E
X
E.9
A1
F
A1E
CN
A1
DEDICATED ELECTRICAL CHASE BELOW FOR SERVICE FEEDERS.
SERVICE #1: 4,000A - TEN (10) 4" CONDUITS
SERVICE #2: 4,000A - TEN (10) 4" CONDUITS
SERVICE #3: 3,000A - EIGHT (8) 4" CONDUITS
H3NA
A1E
6.9
TL3NA
MDP-B
A1
SEAL
MDP-A
A1E
PRELIMINARY DOCUMENTS
L3NA
F
A1
PP-MECH
A1E
KEY PLAN
SCALE
As indicated
ELEV. CAB
ELEV.
MOTOR/CONTROLLER
FAN COIL UNIT
ELEV. CAB
310
ELEV.
MOTOR/CONTROLLER
ELEV.
MOTOR/CONTROLLER
No.
Description
Date
ELEV. CAB
REVISIONS
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
ENLARGED
ELECTRICAL
PLANS
PROJECT NO.
E-141
SHEET NO.
50057109
1
ELECTRICAL KEY NOTES
KEYNOTE TEXT
#
1
2
3
4
5
6
7
8
THREE HOUR CHASE FOR SERVICE ENTRANCE CONDUIT ROUTING. REFER TO ARCHITECTURAL
DRAWINGS FOR DETAILS.
DESIGN/BUILDER TO ROUTE ALL CONDUITS FOR ELECTRICAL SERVICES FOR PHASE 1 AND
FUTURE PHASES IN ELECTRICAL CHASE. STUB-UP AND CAP ALL FUTURE CONDUIT ON
EXTERIOR OF BUILDING.
REVERSE REVENUE METERING EQUIPMENT FOR CO-GENERATION SYSTEM. METERING
REQUIREMENTS PER DUKE ENERGY INTERCONNECTION STANDARDS.
DESIGN/BUILDER TO COORDINATE FINAL CONNECTION REQUIREMENTS TO ALL MECHANICAL
EQUIPMENT WITH FINAL EQUIPMENT SELECTIONS.
2.1 MW, 480/277V, 3 PH., 4 WIRE COGENERATION UNIT. BASIS OF DESIGN IS A GE/JENBACHER,
NATURAL GAS, RECIPROCATING ENGINE.
KITCHEN DISTRIBUTION PANEL AND ALL KITCHEN BRANCH CIRCUIT PANELS TO BE BASED ON
ALL FINAL LOAD INFORMATION IN FINAL DESIGN/BUILD DOCUMENTS.
LAUNDRY DISTRIBUTION PANEL AND ALL LAUNDRY BRANCH CIRCUIT PANELS TO BE BASED ON
ALL FINAL LOAD INFORMATION IN FINAL DESIGN/BUILD DOCUMENTS.
GENERATOR/UTILITY PARALLELING SWITCHGEAR. PROVIDE ALL REQUIRED RELAYING,
INSTRUMENTATION, AND CONTROL PER DUKE ENERGY INTERCONNECTION REQUIREMENTS.
REFER TO NARRATIVES AND SPECIFICATIONS FOR DETAILS.
GENERAL NOTES:
Pinellas County
ELECTRIC CHILLER 2
ELECTRIC CHILLER 1
ELECTRIC CHILLER 3 (FUTURE)
4
FUTURE
HOUSING
PP-MECH
(GEN.)
(UTILITY)
1200A-3P
SPACE
CONTROLS
AND
INSTRUMENTATION
1200A-3P
SPACE
2500A-3P
1200A-3P
SPARE
FUTURE
HOUSING
FUTURE
HOUSING
FUTURE
HOUSING
800A-3P
SPACE
800A-3P
SPACE
800A-3P
SPARE
4
FUTURE (4000A FRAME)
FUTURE
HOUSING
4000A-3P
800A-3P
SPARE
2000A-3P
800A-3P
800A-3P
SPACE
CONTROLS
AND
INSTRUMENTATION
2500A-3P
(GEN.)
4000A-3P
(UTILITY)
SPD
SPD
4000A-3P
MDP-A
3000A-3P
2500A-3P
1200A-3P
SPACE
1200A-3P
SPACE
MDP-B
(TIE)
H3NA
5
SECTION 1 SECTION 2
400A
SPD
4000A
SPD
H3NA
L3NA
L3NA
SECTION 1 SECTION 2
SPD
400A
225A
225A
4000A
ALL SIZES INDICATED ON THIS DRAWING SHALL BE VERIFIED BY DESIGN BUILDER AND
ADJUSTED AS REQUIRED BASED ON FINAL LOAD CALCULATIONS.
ALL FINAL LOAD CALCULATIONS SHALL INCLUDE ALL FUTURE WORK AS PART OF MASTER
PLAN ELEMENTS.
ALL UTILITY WORK TO BE PER DUKE ENERGY REQUIREMENTS.
REFER TO DESIGN CRITERIA NARRATIVES FOR ADDITIONAL DETAILS.
REFER TO MECHANICAL AND ELECTRICAL SPECIFICATIONS AND NARRATIVES FOR COGENERATION DESCRIPTION AND DETAILS.
TL3NA
75KVA XFMR
2000A
LEVEL 3
FUTURE
1
TO BUILDING STEEL
AND COLD WATER
PIPING
TO BUILDING STEEL
AND COLD WATER
PIPING
SEAL
TO BUILDING STEEL
AND COLD WATER
PIPING
PRELIMINARY DOCUMENTS
NOT FOR CONSTRUCTION
KDP
L2KA
L2KA
L2KA
L2KB
400A
KEY PLAN
L2KB
L2KB
SPD
400A
400A
400A
400A
H2NK
SECTION 1
400A
H2N
SPD
SECTION 1
L2N
L2N
SECTION 1 SECTION 2
SPD
400A
225A
225A
800A
TL2KA
TL2KB
TL2N
112.5KVA XFMR
112.5KVA XFMR
75KVA XFMR
LEVEL 2
L1N
L1N
3
UTILITY XFMR 'C'
M
3
FUTURE UTILITY XFMR 'B'
400A
NOT TO SCALE
LDP
H1N
SECTION 2 SECTION 1
SCALE
SECTION 1
400A
400A
SPD
SPD
TL1N
600A
112.5KVA XFMR
LEVEL 1
GROUNDING
ELECTRODE
SYSTEM
No.
Description
Date
REVISIONS
Scale: N.T.S.
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
ELECTRICAL
RISER DIAGRAM
A
PROJECT NO.
E-200
SHEET NO.
50057109
CLOCK OUTLET
EXIT
h
TELEVISI
ON
OUTLET
PANELBOARD
CENTERED OVER DOOR
(WHERE APPLICABLE)
AHU-X
90"
480V, 3
FED FROM "NDH1-4"
REMOTE TEST
VOLUME CONTROL
120/208V, 3, 4W
FED FROM PANEL "XXXX"
VIA T-XXX
80"
FA PULL
STATION
DUPLEX RECEPTACLE
h
h
TELE. OUTLET
EQUIPMENT VOLTAGE
h
6" AFC
EQUIPMENT NAME
54"
SWITCH
48"
78" MAX.
TO TOP DEVICE
PANEL "XXXX"
AHU-X
COMPUTER
OUTLET
480V, 3
FED FROM "NDH1-4"
TELE. OUTLET
36"
AFF
18"
AFF
PANEL "XXX"
PANELBOARD VOLTAGE
PANELBOARD NAME
277/480V, 3, 4W
FED FROM PANEL "XXXX"
PANELBOARD SOURCE
EQUIPMENT SOURCE
(PANEL & CIRCUIT)
TYPICAL EQUIPMENT
42" A.F.F. W/ 36" COUNTER,
39" A.F.F. W/ 30" COUNTER,
48" A.F.F. WITHOUT COUNTER
OR AS NOTED ON PLANS
FINISHED FLOOR
DUPLEX RECEPTACLE
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
10"
JOISTS
#6-32 (TYP.)
CADWELD
B544A018
OR EQUAL
1-1/8"
PRIMARY EQUIPMENT
GROUNDING CONDUCTOR
(PER NEC 250-122)
FS
TS
TYPICAL INDICATING
DEVICES
DELTA
GROUND BAR
TYPICAL INDICATING
DEVICES
TYPICAL CONTROL
RELAYS
FS
TS
DEDICATED TELEPHONE
CONNECTION
FOR THIRD PARTY NOTIFICATION
DIALER
TYPICAL INITIATING
DEVICES
FIRE ALARM
ANNUNCIATOR
PANEL (FAAP)
SECONDARY PHASE
CONDUCTORS
NEUTRAL
COMMUNICATIONS CABLING TO
EXISTING FACP IN CENTRAL
120V POWER
HE
(SI AVY
BY ZED DUTY
ST
CH
RU
AN
CT
NE
UR
L IR
LE
A
L
ON
N
EN
JO GTH
GIN
IST
T
E
ER
SA OM
)
S R ATC
EQ
H
UIR
ED
BONDING JUMPER
(PER NEC 250.28,102)
PERMANENT FIRE
ALARM
ZONE LEGEND
#6 GROUNDING CONDUCTOR TO
NEAREST METAL WATER PIPE.
GROUNDING ELECTRODE,
VIA GROUND BAR
(PER NEC 250.30)
TYPICAL SPRINKLER
TAMPER AND FLOW
SWITCHES
FIRE ALARM
CONTROL PANEL
+
WYE
SECONDARY EQUIPMENT
GROUNDING CONDUCTOR
(PER NEC 250.122)
NOT TO SCALE
NOT TO SCALE
r" NEOPRENE
ISOLATION
PAD
FRONT VIEW
GROUND CONDUCTORS
QUANTITY AS
REQUIRED.
SEAL
STANDOFF BRACKET
PRELIMINARY DOCUMENTS
NOT FOR CONSTRUCTION
NOTES:
COMMUNICATIONS CABLING TO
EXISTING FACP IN "A" SOUTH
1st FLOOR
#6 TO COMMUNICATIONS RACK
GROUNDING ELECTRODE
CONDUCTOR
(PER NEC 250.66)
TYPICAL INDICATING
DEVICES
FACP
ADDRESSABLE
FIRE ALARM
SYSTEM WITH
NETWORK
INTERFACE
CARD(S) AND
BATTERY
BACKUP AS
A3
REQUIRED
SPD
TR
AN
SF
OR
ME
R
9/32"
(TYP.)
DRY-TYPE TRANSFORMER
TYPICAL SPRINKLER
TAMPER AND FLOW
SWITCHES
4"
TYPICAL INITIATING
DEVICES
1"
INSULATOR
GROUND LUGS
1"
3/4"
PRIMARY PHASE
CONDUCTORS
Pinellas County
1.
2.
3.
NOT TO SCALE
CADWELD
B544A018
OR EQUAL
DOUBLE NUT WITH
LOCK WASHERS
KEY PLAN
INSULATOR
ISOMETRIC ELEVATION
NOT TO SCALE
7
SCALE
BREAKER FEEDING
SURGE
SUPPRESSOR
(TYP)
NOT TO SCALE
OPTIONAL TVSS
DEVICE
LOCATIONS (CAT
B3
OR C1 AS
INDICATED
ON DRAWINGS)
No.
NEUTRAL BUS
CONNECTION
BREAKER FEEDING
SURGE SUPPRESSOR
Date
REVISIONS
NEUTRAL BUS
CONNECTION
PANELBOARD
Description
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
ELECTRICAL
DETAILS
NOT TO SCALE
PROJECT NO.
E-201
SHEET NO.
50057109
FINISHED GRADE
PARAPET
COPPERWELD
GROUND ROD
5/8" X 20'-0"
VERTICALLY
DRIVEN.
HIGHER ROOFTOP
5 1/4" DIA VALVE BOX
COPPERWELD GROUND
ROD
5/8" X 20'-0" VERTICALLY
DRIVEN.
CABLE TO GROUND
ROD
HEAVY DUTY TYPE
CADWELD "GT"
SERIES.
24"
(1) 1"C.
CONCEALED
WITHIN WALL
GROUND WIRE
#115000CM
COPPER
CABLE
APPROVED
EXOTHERMIC
CONNECTION
2'-0" MAX. TO
OUTSIDE
EDGE OF ROOF
2" MIN.
MAIN
CONDUCTOR
(COPPER)
CL ROD
ROD CL
AIR TERMINAL
CADWELD BONDED
CONNECTION
TO BUILDING STEEL
PREMANUFACTURED THRUROOF
PENETRATION
MAIN CONDUCTOR (COPPER)
MAINTAIN
20'-0"
BETWEEN
RODS
3" MIN.
COMPACTED GRAVEL
CADWELD BONDED
CONNECTIONS
TO BUILDING STEEL
LIGHTNING CONDUCTOR
LOWER ROOFTOP
NOT TO SCALE
GROUND ROD
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
CLASS 1 COPPER
LIGHTNING
CONDUCTOR (32 x 17
AWG)
CONNECTOR
LOOP WITH
STAINLESS
STEEL SHEET
METAL
SCREW
1\2" DIA.
BRASS
THREADED
RISER
BAR
METAL MOUNT
POINT BASE
WITH STAINLESS
STEEL
SHEET METAL
SCREW
ROOF
SEAL
OFFSET WALL POINT
BASE
BOLT & LEAD
ANCHOR
W/ SEALANT
AROUND BASE
CLASS 1 COPPER
LIGHTNING
CONDUCTOR (32 x 17
AWG)
VERTICAL CONNECTOR
10" MIN
2'-0" MAX
PRELIMINARY DOCUMENTS
NOT FOR CONSTRUCTION
NOT TO SCALE
Pinellas County
KEY PLAN
NOT TO SCALE
NOT TO SCALE
NOT TO SCALE
8
SCALE
NOT TO SCALE
No.
Description
Date
REVISIONS
DRAWN BY
JMB
APPROVED BY
GAC
CHECKED BY
GAC
DATE
03/19/2014
TITLE
ELECTRICAL
DETAILS
A
PROJECT NO.
E-202
SHEET NO.
50057109