Hanson Building Products

precast concrete
box culverts
Box culverts
Easy to install, suitable for very shallow
or deep fill, ideal for use in a wide
variety of civil engineering applications

Hanson Building Products is the They are easy to install and can
largest producer of box culverts in be made to suit very shallow or
the UK, and are members of the deep fill. They also offer economy
Box Culvert Association. by being uniquely designed for
particular loading conditions and are
Since its introduction over 40 efficiently produced in standard sizes.
years ago the range of box
culverts we offer has continued As these advantages have become
to expand. Whilst offering widely recognised their range of
increased flexibility Hanson Box applications has increased making
Culverts retain all their original them ideal in a wide variety of civil
advantages. engineering applications to include:

Culverting Service Tunnels


Watercourses
Pumping Stations
Attenuation Tanks
Channels
Road Crossings
Portals
Multi-cell
Basements Solutions
Construction
CSO Chambers
Pipe Replacement
Pedestrian and
Vehicle Subways
Sea Outfalls
CULVERT Escape Tunnels
BOX

ASSOCIATION Shafts
Advantages of using box culverts
Flexibility of range to accommodate
almost any size requirement
Availability of multi-cell sections
Can be laid in multiple sections
Ease of installation
Accommodation of high storage volumes
Use with shaped invert for dry weather
flow situations eg. sloping v and half round
Qualified technical department with CAD
facilities, available to assist at all stages with
design specification and contract development
Box culvert design specific to client requirement

Hanson Box Culverts are available For larger culvert widths, twin or By comparison with arched or
in a range of 144 standard sizes multiple sections may also be circular sections no flow area is lost
from 1000mm x 600mm to considered. Unlike pipes and through either excessive spacing
6000mm to 3600mm. Non-standard corrugated steel assemblies, apart or curved profiles.
sizes and internal profiles can also box culverts can be designed to
be readily provided including carry vertical load without the All products are manufactured
shaped inverts and dwf channels. relieving effect of side pressure. under a Quality Management
System complying with ISO 9001:
Reference to our table of standard Therefore, when culverts are 2000 and we are registered within
sizes will give the size necessary used in multiple sections, they the BM Trada Certification Scheme
to meet any conditions which may can be laid side by side with only for approved quality systems.
be required in terms of storage a nominal gap between them.
volume, flow capacity etc.
Box culverts

Height Table No.1 Dimensions, flow area and discharge rate Width mm Flow area m2 Discharge rate m3/s
mm
1000 1200 1500 1800 2100 2400 2700 3000 3300 3600 3900 4200 4500 4800 5100 5400 5700 6000

600 0.53 0.65 0.83 1.01 1.19


0.50 0.64 0.86 1.07 1.29

800 0.73 0.89 1.13 1.37 1.61 1.85 2.09 2.33


0.77 0.99 1.33 1.67 2.01 2.36 2.71 3.06

1000 0.93 1.13 1.43 1.73 2.03 2.33 2.63 2.93 3.23 3.53 3.83 4.13 4.43 4.73
1.07 1.37 1.84 2.32 2.80 3.29 3.79 4.29 4.79 5.29 5.80 6.30 6.81 7.32

1200 1.37 1.73 2.09 2.45 2.81 3.17 3.53 3.89 4.25 4.61 4.97 5.33 5.69 6.02 6.38 6.74 7.09
1.76 2.37 3.00 3.64 4.29 4.95 5.61 6.28 6.95 7.62 8.29 8.97 9.64 10.28 10.96 11.64 12.32

1500 2.18 2.63 3.08 3.53 3.98 4.43 4.88 5.33 5.78 6.23 6.68 7.13 7.55 8.00 8.45 8.90
3.21 4.08 4.98 5.89 6.81 7.74 8.68 9.62 10.57 11.52 12.48 13.44 14.37 15.33 16.30 17.27

1800 3.17 3.71 4.25 4.79 5.33 5.87 6.41 6.95 7.49 8.03 8.57 9.08 9.62 10.16 10.70
5.21 6.38 7.57 8.78 10.00 11.24 12.48 13.74 15.00 16.26 17.54 18.79 20.07 21.35 22.64

2100 4.34 4.97 5.60 6.23 6.86 7.49 8.12 8.75 9.38 10.01 10.61 11.24 11.87 12.50
7.83 9.31 10.82 12.36 13.92 15.49 17.07 18.67 20.27 21.88 23.48 25.11 26.74 28.37

2400 5.69 6.41 7.13 7.85 8.57 9.29 10.01 10.73 11.45 12.14 12.86 13.58 14.30
11.11 12.94 14.81 16.70 18.61 20.55 22.50 24.46 26.43 28.40 30.40 32.40 34.41

2700 7.22 8.03 8.84 9.65 10.46 11.27 12.08 12.89 13.67 14.48 15.29 16.10
15.11 17.32 19.56 21.84 24.14 26.46 28.80 31.15 33.52 35.90 38.29 40.70

3000 8.93 9.83 10.73 11.63 12.53 13.43 14.33 15.20 16.10 17.00 17.90
19.88 22.49 25.14 27.82 30.53 33.27 36.02 38.80 41.59 44.40 47.22

3300 10.82 11.81 12.80 13.79 14.78 15.77 16.73 17.72 18.71 19.70
25.48 28.52 31.59 34.71 37.85 41.02 44.22 47.44 50.68 53.93

3600 12.89 13.97 15.05 16.13 17.21 18.26 19.34 20.42 21.50
31.95 35.43 38.96 42.53 46.13 49.77 53.43 57.11 60.81

Table No.2 Table No.3 Table No.4 Notes


Circular pipe discharge rates for Gradient multiplier Roughness multiplier 1. The standard range of box culverts 5. All box culverts are manufactured to order
comparison with standard culverts generally have flat inverts and 190mm and to the specific required design criteria,
Diameter Flow area Discharge Roughness corner splays up to 4800mm span and the external loading conditions will govern
DN m2 rate m3/s Gradient Multiplier coefficient ks Multiplier 225mm splays from 5100mm to 6000mm the wall, roof and floor thickness, unit
span and a maximum length of 2m. length and reinforcement content.
900 0.64 0.67 1 in 1000 1.0 0.06 1.11
1 in 800 1.1 2. Sizes other than those stated can 6. Joints are a standard rebate within the
1050 0.87 1.00 0.15 1.05
be manufactured to suit customer wall of the unit and the box culverts can
1200 1.13 1.42 1 in 700 1.2 0.30 1.00 requirements. be jointed using sealant strip to provide
1350 1.43 1.93 1 in 600 1.3 0.60 0.93 a seal and flexible joint if required.
3. Special internal profiles, shaped inverts
1500 1.77 2.54 1 in 500 1.4 1.50 0.85 and dry weather flow channels can be 7. Special insert pins are cast in to each box
1 in 400 1.6 produced and are available on request. culvert to enable them to be lifted.
1650 2.14 3.25
1 in 300 1.8 4. Tapered units for bends, units with 8. Channel units can also be produced
1800 2.54 4.08
2100 3.46 6.11 1 in 250 2.0 Technical enquiries manhole openings and pipe access holes
can be produced and are available on
if required.

2400 4.52 8.65 Tel: (01773) 602432 request.


Box culverts
Standard specifications and
guidance on installation

Hydraulic design with an assumed roughness Box culverts carrying highway


coefficient of 0.6mm, the discharge loading or railway loading are
Discharge rates for box culverts in
rate is given by 4.29 x 1.4 x 0.93 designed to current standards
the Hanson standard range are
= 5.59m3/s. The flow capacity of a and specification as stipulated by
calculated for a gradient of 1 in
culvert is determined by a number the client.
1000 in accordance with the
of different factors. In addition to
Colebrook-White equation The lowest grade of concrete
the gradient and roughness
assuming the culvert running full used is C50 with a 20mm
coefficient, the geometry of the
under uniform flow conditions. maximum size of aggregate.
inlet and outlet and the tailwater
Comparable discharge rates for The nominal cover to
level can affect the mode of flow
circular pipes are given in the Table reinforcement is 30mm.
and may prevent the culvert from
2 (overleaf).
running full or under uniform flow
conditions. In such cases the flow An experienced team of engineers
capacity will be lower than the full and technicians backed by CAD
discharge rate. facilities provide a flexible and
comprehensive design and
Surface loading detailing service enabling the
clients design and specification
and fill depth
criteria to be satisfied.
Loading applied at the ground
surface and weight of fill material Delivery and offloading
produce a combination of vertical
and horizontal forces on the box It is the contractors responsibility
culvert. Surface loading may be to offload the box culverts on
specified as a standard loading delivery. A hard level access area
type, equivalent uniform loading or should be provided which can be
individual wheel loads. The critical used safely by standard articulated
load on a culvert can occur at delivery vehicles. The contractor
minimum or maximum fill. should provide a suitable crane of
adequate capacity for lifting the
For any gradient between 1 in 1000 Each enquiry for a culvert should culvert. For reasons of safety and
and 1 in 250, the gradient state the minimum and maximum economy certain box culverts are
multiplier (Table 3 overleaf) should fill depth and the amount or type of delivered to site on end rather than
be applied. A value of 0.3mm has surface loading. It is recommended as laid, and will require a safe
been assumed for roughness that the minimum fill depth should method of turning during
coefficient, ks, which depends be not less than 200mm or one offloading. A data sheet giving
upon the accuracy of laying and fifteenth of the internal width of guidance of lifting and turning is
jointing in addition to the quality of the culvert if this is greater. available and is issued to clients
the culvert surface. Where a prior to the first delivery.
Design and detailing
different value is required, the
discharge rate at the appropriate Box culverts are generally designed The offloaded box culverts should
gradient should be adjusted by the and detailed in accordance with be levelled carefully on a firm level
use of the roughness multiplier the Box Culvert Association base away from the edge of the
(Table 4 overleaf). Standard Specification which trench, and if any further
covers materials, manufacturing movement is required it should be
Thus, for a 2400 x 1200 section tolerances, external loading design by lifting; the culvert should never
laid at a gradient of 1 in 500 and and detailing standards. be dragged or dropped.
Bedding, laying and A culvert line is usually laid Jointing diagram
backfilling directly on the bedding starting
from the downstream end with
Excavation can be kept to a the sockets facing upstream,
minimum with only nominal to receive the next culvert.
working space required on each
Compressed
side of the box culvert. When The trench should be backfilled as strip if used

working in trenches the normal soon as possible after the culvert 25

requirements for health and safety has been laid and it should be
must always be observed. filled evenly on each side of the
75
trench. Backfilling should continue
Internal
The base of the trench should be in 200mm compacted layers to pointing
uniformly prepared before laying a if used
reach the required depth of cover.
Internal Face
200mm bedding of compacted
granular material over the full Where loads from construction
width of the trench. A surface plant may exceed the design approximately one tonne per metre
blinding of the fine material will load of the box culvert of strip plus about half of the
assist levelling. Local packings are protective measures will be weight of the culvert unit to
subject to settlement and should required. This is particularly overcome base friction, less if the
not be used. As an alternative to relevant at shallow fill depths. unit is suspended from the crane
granular bedding a concrete whilst jointing. Heat may be
blinding layer is sometimes required to soften the strip when
Jointing
preferred to protect the formation working at low temperature.
or to allow a faster rate of laying The culvert sections generally have
the culverts. rebated joints and can be laid When the box culvert is of
open, or sealed using pre formed sufficient size for access, it can be
A layer of unreinforced concrete strips and/or pointing materials. pointed internally with an
approximately 75mm thick on a Reference should be made to the elastomeric or bitumen based
trench bottom which has been well jointing material manufacturers material using a suitable primer.
prepared to provide a uniform specification and recommendation Not all methods of jointing,
support is generally sufficient. for use of the product. however, should be expected to
be completely watertight.
A system using preformed strip within
the joint is most commonly used.
When the strip is bitumen based
the joint faces should be cleaned, For further information,
primed and allowed to dry. The technical & sales enquiries
strip is then applied to the internal please contact:
corner of the socket just before Hanson Building Products
the culvert is laid in the trench. Birchwood Way,
Cotes Park Industrial Estate,
Joints are closed to a nominal gap Alfreton, Derbyshire, DE55 4NH
by pulling against previously laid Tel: (01773) 602432
culverts with an applied load of Fax:(01773) 603134
Floors and Precast Division Hanson Building Products
Head Office
0870 6097094 Stewartby
Bedford
MK43 9L2

Tel: 08705 258258


Website: www.hanson.biz