FACTORY ACCEPTANCE TEST

REPORT
FOR
261 EX d 400 Watt

BRAND : CHALMIT
PART : 261D/400/HS/C1
NUMBER
CLIENT: PETRONAS GAS
BERHAD
CONTRACT : BPE
OR
SITE : SEGAMAT
COMPRESSOR
STATION UNIT 1

Tested by : Signatur : Dat :


e e
Witnessed : Signatur : Dat :
by e e
Witnessed : Signatur : Dat :
by e e
Witnessed : Signatur : Dat :
by e e
Comments :

These procedures describe the methods for inspecting and checking the
unit to ensure that it meets the operational requirements.
1. REFERENCE DOCUMENT
Factory Acceptance Report from OEM, Datasheet and Ex Certificate

2. TESTING EQUIPMENT
Digital Multi-meter, Clamp meter

3. PROCEDURES
Physical Inspection

Test Acceptance Criteria YES/


NO
Dimensional Verify the critical dimensions correspond to
Inspection appropriate specifications and drawings
Label Verify against product information of the
Information part ordered
Enclosure Verify material to meet appropriate
specification
Reflector Check drawing and verify material to meet
appropriate specification
Cable Entries Verify to conform to the product information
of the part ordered

Functional Test

Test Acceptance Criteria YES/


NO
Running Test Energise product and verify its operation