Professional Documents
Culture Documents
This
document may not, in whole or in part, be reproduced, stored, transmitted
or distributed in any form or by any means, whether electronic,
mechanical, by photocopy, recording or otherwise, without the prior
written permission of EX20. Except where otherwise expressly agreed in
writing by EX20, EX20 shall have no responsibility or liability for any loss
6 (direct, consequential or otherwise) which may arise from reliance on or
use of this document or the information contained therein.
4
10026-DWG-S100000-
AR-600058
250 2,800 250 8,695 250
120
150
Notes:-
2,150
2,150
1. This drawing indicates the Design intent only.
1,925
All Structure & MEP services shown are purely indicative
and must be verified and co-ordinated by qualified agencies prior
3,000
to the commencement of any work on site.
3
300
UPPER ROOF LEVEL 10026-DWG-S100000-
UPPER ROOF LEVEL 2. Do not scale off drawing.Use figured dimensions only.
300
300
AR-600058
40,390 40,390 3. All dimensions shown are in millimetres, and do not take into
account applied finishes, unless specifically indicated otherwise.
4. Any omissions or discrepancies found shall be reported to the
Engineer immediately.
5. Levels are given in metres to three decimal places above DM.
Datum level.
3,000
3,000
2,700
2,700
6. This drawing is to be read in conjunction with the relevant sections
of the specification and schedules.
3,681
3,545 4,200 1,200 7. The contractor shall submit full shop / setting out drawings for
3,000
approval (based on site dimensions) prior to commencement
4,596
+37,390 of any site works, or placing any orders and or manufacture of
ROOF FLOOR +37,390 ROOF FLOOR any fittings, Fixtures and components shown.
300
37,390 37,390
1,596
1,596
ARCHITECTURAL MESH
SCREEN SIDING PANEL
915
ON ALUMINIUM FRAMES
+35,494 ANCHORED TO +35,494
13
SIDE OF SLAB
3,950
3,950
12
250
3,650
11
10
13 RISERS @ 158MM
3,000
9
8
2,054 7
2,054
6
5
4
3
5
2,785
2
1 10026-DWG-S100000-
AR-600058 +33,440
SECOND FLOOR +33,440 SECOND FLOOR
3,700
300
33,440 33,440
1,596
1,596
915
3,000
13
+31,544
2 +31,544
3,950
3,950
12 10026-DWG-S100000-
250
3,650
11 AR-600058
10
13 RISERS @ 158MM
9
8 Description
No
7
2,054
2,054
6 SAFETY, HEALTH AND ENVIRONMENT INFORMATION
5 Brief details on the identified hazard symbol referencing the unusual residual
2,262
4 hazards / risks are listed above.
3
2
3,177
1 +29,490
FIRST FLOOR +29,490 FIRST FLOOR
300
29,490 29,490
3,000
1,073
1,073
915
250
9 RISERS @ 153MM
25
24
23
1,373
1,373
22
21
20
1,580
19 +26,745
+26,745
5,490
5,490
Programme/Project Management Consultant
2,495
250
1,123
1,123
3,015
915
8
250
9 RISERS @ 153MM
7
?
6
5
300 7
1,374
1,374
4
1
1,124
1,124
120
3 10026-DWG-S100000-
2 10026-DWG-S100000- AR-600058 Project Title
153
1 AR-600058
285
Drawing Title
STAIRCASE SECTIONS
AA 01/03/2017
Designed Drawn Checked
HA NA PM
Model File Ref: Scale A1 (594x841) Revision No
10026-MDL-S100000-AR-00104 1 : 50 A
Drawing No
10026-DWG-S100000- AR-400017
A360://Thematic Districts/10026-MDL-S100000-AR-000104_Mockup.rvt