You are on page 1of 7

()

()
CF K

:
:

(1) : 258B Thermocouple welder




(2) (Thermocouple reader): Fluke 52II
KJ
TE Type
(3) : T type K type

(4) :

(5) :
(Power supply)
(6) :
(7) :

(8) (Power supply) : GPC-3060D

1
(9) (Infrared Thermometer): Fluke 568


(
1C )

3-1 :

A B
E
Seebeck E
AB
E a T a T

10V

3-2 :

2


(C) (mV)
+ -

1. 1. CO


-200~1200 -5.89/-200C
K
2.
48.8/1200C 2.

-8.82/-200C 1. 1.
-200~800
E 61.02/800C
2.
-7.89/-200C 1. 1.
J -200~350
72.28/750C
-5.6/-200C 1. 1.300

T -200~350 17.82/350C

1.24/500C 1. 1.
500~1700
B 12.4/1700C

0/0C

R 0~1600

18.84/1600C
S -7.89/-200C
0~1600
72.28/750C

3-3

(1)
0C
0.5C

3
(2)
100C
0.5C
(3) ()
30

(T type)

(1)
(2)
(3) PURGE 1 (
)
(4) 20cm
(5) 1cm
(6)
3mm
3mm

(7)


(8) ()(
)
(9) WELD

(10) ()(
) () ()

(K type)

(1) 20cm
(2) T type (5)~(9)
(3) ()(
) () ()

(1) (Thermocouple reader)


(Type)
(2) 0C
0.5C (
)
(3)

(1)
(2) 10V 10 (
40~50C)
(3) T type (
)
(4) 0.10.51
()

T type
(C)
(C)


(C) (C)
()
0.1
0.5
1

(1) ?
(2)
(3) ?

THERMOUPLE
WIRES CLOSELY
TOGETHER

INSULATION

You might also like