SCHEDULE OF FINISHES

Walls
Footings 230x600mm in medium strength concrete to NBR standard and SANS 10400.
26.5 Walls are built with 90mm bricks - heights as per plan. External walls to plastered and
ROOF PITCH painted with 50mm cavity between internal and external skins with 2.5 butterfly wire ties

1,968
per square meter. All internal walls plastered with lime cement.
300 Brickforce in 4 layers over all openings, with precast concrete lintels to openings greater
300
than one metre.

Window-sills

4,518
DPC External & Internal, smooth finished cement plaster.

Roof Construction
Cement roof tiles @ 26.5 pitch on 38x38 SAP battens at maximum 320 centres on

2,550
prefabricated gangnail trusses at maximum 760 c/c, fixed to 114x38 wallplates and
anchored to brickwork with 30x2mmx1m hoop iron ties, built into walls for minimum of
600mm. SABS approved underlay to tiled roof. All roof timber to be minimum Grade 5 SA
PLASTER & PAINT Pine TAN treated. All gable ends to be tied with hoop iron built into wall for minimum 600mm
NGL and up to two trusses away from gable to SANS 10400-L where applicable. Bracing as
BEDRM BATHRM
DPC
250mic DPM
DPC FRONT ELEVATION 1 per A19 Engineer.
375mic DPM UNDER ALL WALLS 400x200 SCALE 1:100
MINIMUM 150mm ABOVE FGL THICKENED Eaves
FOUNDATION 300mm Open eaves overhang with 225mmx10mm painted fibre cement fascias.
600x230 600x230
SECTION A-A Rainwater Disposal
SCALE 1:100 Alu. gutters with PVC downpipes as per plan.

Ceilings
25mm Isoboard EPS ceiling on 38 x 38 SA Pine battens at 300mm spacing and 76mm Rhino
cornice with 155mm thick flexible polyester blanket(Isotherm).

Floors
3 Finished as per plan and/or client choice/building tender, on 25mm screed, on 80mm
7,200 concrete for ground storey, (as above) on 250 micron waterproof sheeting, on compacted
230 90 230 filling and sand blinding. All floor levels to be a minimum of 150mm above FGL.
3,160 3,490
230 90 90 230 Doors & Windows
3,160 880 2,520 Windows top-hung aluminium, as per plan codes & elevations.
Note : Safety glass to window panes larger than 1sq.m or closer than 500mm from FFL to
PLASTER & PAINT SANS 10137 and to comply to SANS 10400-N.
230

230
Drainage
ELEVATION 2
1,205

1,230
110mm Smooth uPVC Sewer pipe with minimum 1:60 fall with IL at minimum 450mm. 50mm
SCALE 1:100 2way vent valve on start of one pipe sewer system. All sewer lines passing under
BEDRM 2
1,800

B.I.C

B.I.C

BEDRM 1 structure to comply to SANS 10400-PP24 (encase in sand or concrete). All drainage to
(Carpet)
(900x1100)

comply to SANS 10400-P.


(1200x1200)
(Carpet)
2,850

900
W6

1,200

3,230
Electricals - as per building tender.
W2

Position of Oostersee Electrical connection box on exterior wall to be determined on site.


90

NOTES:
Figured dimensions takes preference to scaled dimensions.
1,850

1,410

All relevant levels and dimensions to be verified on site prior to construction.


90

All work to comply to NBR, Local Bylaws and Municipal Regulations.


90

BEDRM 3
(600X900)

EN-SUITE All levels to be determined on site and can/may be to adjusted to the descrepancy of the
(Carpet)
(900x1100)

1,200

(Tiles)
600

4
W3

developer and his appointed builder. Developer to approve plan prior to submission to
2,470

2
900
W6

council.
All glazing to SANS 10137 & SANS 10400-N. Printed dimensions take prference over
9,720

9,720
740
B.I.C

90

A BATH RM
A PLASTER & PAINT
scaled dimensions. All work to be carried out in strict accordence to NBR and local
bylaws.
(900x900)
HWC IN
ROOF

(Tiles)
1,600
1,680

900
W5
90

Finishes in builders contract takes preference over finishes specified on plan.


TV ELEVATION 3 In case of discrepances the author of the plan should be contacted before proceeding
SCALE 1:100 with any construction.
90
(1500x1500)

1,680
3,110

1,500
W1

KITCHEN
LOUNGE (Tiles)
2,960

(Tiles)
900
1,035
230 420 230

PD26
1,060

WM
W6
(900x1100)
230

230 x 230 mm BRICK COLUMN ON 800 x


W6
800 x 300mm MASS CONCRETE FOOTING
(900x1100)
RE2

WITH 2 x Y12 STEEL RODS IN CENTRE


BENT 90 INTO FOOTING FOR MIN. 300mm 37 VAN DER STEL STREET P.O. BOX 1399 TEL: 021 906 6770
KUILSRIVER KUILSRIVER FAX: 021 906 6775
1,165 900 1,165 900 1,085 900 1,085
ELEVATION 4 7579 7580 EMAIL : nationhousing@mweb.co.za
230 90 90 230 SCALE 1:100
3,160 880 2,520 ELECTRICAL
230 230 230 HOUSE PLAN- Type 6-68 sq.m DATE : AUG 2016
900 2,610 SANS 10400-XA TELEPHONE POINT DRAWING : Type 6-68sq.m
HWC DETAILS: CEILING LIGHT POINT
PROPOSED NEW DWELLING
7,200 MONTCLAIR
PIPING 15mm AND 22mm CLASS 1 FOR .......... ON ERF ........... , PROJECT : NATION HOUSING
WATERPROOF LIGHT POINT
COPPER TUBE
1 HWC KWIKOT ECONO STD GALV. 150L 15 AMP PLUG POINT
MONTCLAIR SCALE : 1:100
GEYSER.
15 AMP UNDERCOUNTER
FLOOR PLAN
SCALE 1:100
AREA HOUSE : 68 sq.m LAGGING (R=1) ON ALL EXPOSED
PIPES MOUNT PLUG POINT

WALLS EXT. 230 CAVITY 15 AMP PLUG POINT 2000mm HIGH


W1= 1.5x1.5 = 2.25 sq.m
1200mm HIGH PC WALL INT. 90 x 190 mm W2 = 1.2x1.2 = 1.44 sq.m DISTRIBUTION BOARD
W3 = 0.6 x 0.9 = 0.54 sq.m
W5 = 0.9 x 0.9 = 0.81 sq.m TV TV POINT
BUILDING LINES
NOTE: W6= (0.9x1.1) x 3 = 2.97 sq.m
RAINWATER CHANNEL
DP
FFL ABOVE NGL TO BE TOTAL =8.01 sq.m STOVE CONNECTION
RAINWATER D.P. FLOOR AREA : 68 sq.m
DETERMINED ON SITE. FENESTRATION PERCENTAGE :
110mm PVC SEWER
MINIMUM 150mm. 11.78% BALL FITTINGS TO ALL LIGHT POINTS
AT 1:40 GRADIENT