CEILING NOTES:

ROOFING NOTES:
50x100 Wall pieces against Tie beams, 50x100 Ceiling joists & 50x100 GENERAL NOTES:
28G Galvanised pre-coated Iron sheets, on 50x75 purlins at 1.3m c/c max, branding all at 600 c/c max against expanded Ceiling Wire lath 1:3 pricking 1. The contructor to check all dimensions on site, figured dimensions are prefered to be read out.
on 50x150 Rafters at 2m c/c max 50x100 ties & struts, on 50x100 Tie beams, morter to ceiling plastered with 1:4 morter finished in white calcium or equally Any queries arising should be referred to the Designer before commencement of work.
all on 100x75 Wall plates & 25x225 facia & Berge boards. Pitch angle 30. approved material 2. PV/O denotes permanent vents to be provided to all the external Windows & Doors connecting
the rooms internally.
3. All external Doors & Windows are to be supplied with louvers except internal Doors which
should carry fine light glazing unless or otherwise as indicated.
4. Provide 1000g polythene sheet damp proof course under all structural walls and 1000g
polythene damp proof membrane on 50mm selected quarry dust blinding throughout the
structure incase of any threats.
5. All reinforced concrete and columns,beams, wall, and structures should be in accordance to the
30°

structural engineers details.


30°

6. All works involving concrete and the like should be properly cured for atleast 7 days before the
commencement of the next job.
400

600

7. Provide at-least 150 end & 75 side laps between roofing sheets on purlins spaced 1300c/c
200

1200

maximum on trusses at 2000 c/c maximum.


600

8. All super structural brick work to be reinforced with 2no. 35x3 hoop irons at every two alternate
3000

3000

course in 1:4 mortar.


2600
2400

2400

9. All walls 200mm below ground level to be reinforced with 2no. 25x3 hoop irons at every two
1800

alternate courses in 1:3 mortar.


10. All drainage passing under building and drive areas to be of heavy duty cast iron and encased
with 100mm thick concrete.
11. All sanitary works to be in accordance to the MoH Rules and Regulations.
12. All works to be carried out in compliance with local Authority Regulations.
13. Foundation depth to be determined from site relative to the nature of soil. Steps unless or
otherwise are not encouraged. Anti-termites treatment should be done to foundation to a total
eradication of termites before casting the base concrete.
14. All dimensions should be checked on site and read out in units or millimeter(mm).
15. Provision should be made for Designer to periodically visit the to check if the contractor
FOUNDATION NOTES: adheres to the availed design unless otherwise permission is seeked for any alterations to be
made on site.
6
25X125 conc. skirting, on 30 APC 1:3, & cmt, sand scrd, on 100 plain conc. Floor slab (1:3:30 ), on 230 reinforced plinth walls in header (1:3 mortor mix), 16. The Designer shall carry no punishable blame for any defective works executed in his absence
6
against 230 hardcore blinded and well compacted, on 200 consolidated Murram, all in on 690x230 plain fdn conc. 1:3:30 ). on 150 Apron plinth wall thereby leading to any forms of structural failure as a result of lack of consultation.
against 150 hard core properly blinded and well compacted on consolidated Murram all on

PROJECT CLIENT DESIGNED BY: DRAWING NO. CHECKED BY: DATE: DISCRIPTION SCALE
PROPOSED COMMERCIAL
BUILDING TO BE Mr. YASIN AHUMAD Mr. ABDULKHADIR KHARIM VIGA
CONSTRUCTED AT ODROPI
PRCOBUCOODYTCYD M.A.T.E CONSULTANCY Typical Site Layout & Slab 1:150
VILLAGE, YUMBE TOWN Mob. 256-782-834-288 Mob. 256-783-661-690 NOV/2021
COUNCIL, YUMBE DISTRICT 256-783-551-996