You are on page 1of 2

Molecular Specialties, Inc.

Phone 414-258-6724 Fax 414-727-9578


E-mail rich.stevens@molspec.com

TPX Capillary & Holder


For use with Molecular Specialties' X-Band EPR Probe Loop Gap Resonator (Catalog No. XP-0201)

TPX Holder TPX Capillary


(Catalog No. TPX H-2) (Catalog No. TPX-2)

Maximizing Your Potential


Molecular Specialties' X-Band Loop Gap Resonator provides a host of features
crucial for your successful EPR experiments, including outstanding sensitivity, high filling
factor, and low Q Factor (600 unloaded).

Achieving optimal results is fast and easy with the TPX Capillary sample tube:

Accommodates both liquid and solid samples.

Ideal for studies where you want to control the amount of oxygen in a
sample; typically three to 10 times greater gas permeability than other plastics.

Accepts common sealants, which are removed after use with a piece of
common copper-coated wire.

Easily cleaned with distilled water and absolute alcohol so they can be used
again and again.
Using a TPX Capillary
1. Place your test sample into the TPX 8. Slide the wire completely through
Capillary. the TPX Capillary while rotating.

2. Wipe the outside of the tube with a 9. Clean the TPX Capillary with
delicate task tissue. distilled water and absolute alcohol.

3. Place the end of the tube into a sealant Its that easy!
pad, leaving a small pocket of space
between the sample and sealant.

4. Thread the tube into the thinner end of


the TPX Holder. (See photo at right.)

5. Conduct your experiment.

6. Dispose of your sample after the


experiment and acquire a small piece
of 26AWG copper-coated wire.

7. Create a small kink at the end of the


wire with your thumb and forefinger.

Threading a TPX Capillary into a TPX Holder.

Choosing a Sealant Molecular Specialties


A sealant typically a clay or wax must be Molecular Specialties, Inc. designs,
applied to the end of the TPX Capillary to prevent manufactures, and sells EPR-related
products, including modulation coils
escape of the sample during testing. Popular and probes. Its products serve a world-
sealants include: wide market, and engage the biophysics
and molecular/cellular chemistry
laboratories of academic institutions.
Fisherbrand Hemato-Seal Tube Sealing
For Further Information, Contact
Compound (Catalog No. 02-678) Richard J. Stevens, President & CEO
Molecular Specialties, Inc.
Bruker X-Sealant (Catalog No. 6130900) 10437 Innovation Drive, Suite 301
Milwaukee, WI 53226
Phone: 414-258-6724
Oxford Labware Critoseal Fax: 414-727-9578
(Catalog No. 8889-215003) E-mail: rich.stevens@molspec.com
Web: www.molspec.com