Conducted by Hoang Minh Hieu - Process Engineer in CCP
CALCULATE THE FLOW OF LP AND HP COMPRESSOR IN CCP
Input the parameters in the white cells
(1 ft3 = 0,028261 m3) Cc thng s PT, TT,
FT cn tnh lu
lng ly t HMI
Orifice reference temperature in Degrees R, T0
Efficiency of LP/ HP compressor, C'
11.60
Diffrerential Pressure (FT-0301, FT-0402) acrross the flow element in inches
W.C., H kpa
3890.00
Discharge pressure (PT-0306, PT-0405) in psia, P1
kpa
154.60
Gas flowing teperature (TT-0304, TT-0408) in Degrees, T1, oR
C
Flow rate in standard, Q, ft3/day (cubic feet per day) H .P1.T0
Q C '.
(Following to the formular AGA-3) T1
Flow rate in standard, Q, m3/hr (cubic meter per hr)
H .P1.T0
(Following to the formular AGA-3) Q C '.
T1
Following the above data sheet, allowable error percent is inputed in cell F15, the results following:
%Error = 1% LP and HP Compressor measurement element: OK, else other train: false
%Error = 2% - 3% LP compressor of train B/E; LP/ HP train F: OK; else any stages in trains: FALSE
%Error = 4% LP compressor measurement elements of trains: OK; HP compressor measure element of Train F: OK;
To abtain %error = (+/-) 4% or 5%, the flow measurement elements/ equipments of HP compressor in turbines Train A-E
+ Cng thc tnh ton ca Solar a ra (HMI)
(LP: C'=14437.8 cfh, HP: C'=7562.8 cfh) Q =Sqrt[( * 10)/1]
+ Cng thc tnh ton lu lng trong PLC (Scada)
(LP: C'=4851.753 scmh, HP: C'=2434.705 scmh) =Sqrt[(*2)*(1+101.3)/(1+273
+ Cng Thc tnh lu lng cp II Train-F (do bc Vinh vit) trong chng trnh PLC
Q = C * Sqrt[ H * (P1 + 101.325)/ (T1 + 273.15)]
Trong :
C = 1770000 scmd
H = Diffrerential Pressure, FT-0401, (inH2O)
P1 = Pressure Transmiter, PT-0401, (kpa)
T1 = Temp Transmiter,TT-0401, ( K)
TRAIN B
LP Compressor
Cc thng s PT, TT,
Gi tr c trn HMI Cng thc tnh ca Gi tr c t
Cng thc tnh Solar FT cn tnh lu
(Solar tnh) Scada SCADA
lng ly t HMI
774.27 Khng dng
14437.8 4851.75
46.569708 11.6 12.70
in H2O kpa kpa
571.9467 3890 11660.00
psi kpa kpa
768.87 154.6 155.30
R C C
56.7 1.7135
MMscfd MMscmd
66824.8267484553 74250 71397.1725471361 70724
Scmh Scmh Scmh Scmh
ains: FALSE
measure element of Train F: OK; else other HP compressor meaurement elements: FALSE
ompressor in turbines Train A-E need to be corrected again.
0)/1]
(1+101.3)/(1+273)]
T1 + 273.15)]
HP compressor
Cc thng s PT, TT,
Gi tr c trn HMI Cng thc tnh ca Gi tr c t
Cng thc tnh Solar FT cn tnh lu
(Solar tnh) Scada SCADA
lng ly t HMI
761.7 Khng dng
7562.78 2434.71
50.985801 12.7 11.90
in H2O kpa kpa
1714.3698 11660 4179.00
psi kpa kpa
762.39 155.3 156.20
R C C
53.6 1.5432
MMscfd MMscmd
63161.0369430726 50710 64300.8675759409 65188
Scmh Scmh Scmh Scmh
TRAIN C
LP Compressor
Cc thng s PT, TT,
Gi tr c trn HMI Cng thc tnh ca Gi tr c t
Cng thc tnh Solar FT cn tnh lu
(Solar tnh) Scada SCADA
lng ly t HMI
774.27 Khng dng
14437.8 4851.75
47.774097 11.9 12.70
in H2O kpa kpa
614.43837 4179 11614.00
psi kpa kpa
774.63 156.2 158.80
R C C
59.3535542536 1.793930655
MMscfd MMscmd
69891.283198347 72300 74747.1106261231 72847
Scmh Scmh Scmh Scmh
HP compressor
Cc thng s PT, TT,
Gi tr c trn HMI Cng thc tnh ca Gi tr c t
Cng thc tnh Solar FT cn tnh lu
(Solar tnh) Scada SCADA
lng ly t HMI
761.7 Khng dng
7562.78 2434.71
50.985801 12.7 11.90
in H2O kpa kpa
1707.60642 11614 4103.00
psi kpa kpa
762.39 158.8 141.20
R C C
53.5321398292 1.5339451683
MMscfd MMscmd
63036.3251546884 51900 63914.3820123172 65320
Scmh Scmh Scmh Scmh
TRAIN D
LP Compressor
Cc thng s PT, TT,
Gi tr c trn HMI Cng thc tnh ca Gi tr c t
Cng thc tnh Solar FT cn tnh lu
(Solar tnh) Scada SCADA
lng ly t HMI
774.27 0.00
14437.8 4851.75
47.774097 11.90 15.30
in H2O kpa kpa
603.26409 4103.00 11577.00
psi kpa kpa
774.63 141.20 153.80
R C C
58.8113710015 1.8098400934
MMscfd MMscmd
69252.8398280842 73220 75410.0038924195 75930
Scmh Scmh Scmh Scmh
HP compressor
Cc thng s PT, TT,
Gi tr c trn HMI Cng thc tnh ca Gi tr c t
Cng thc tnh Solar FT cn tnh lu
(Solar tnh) Scada SCADA
lng ly t HMI
761.7 0.00
7562.78 2434.71
61.423839 15.30 11.60
in H2O kpa kpa
1702.16631 11577.00 4066.00
psi kpa kpa
762.39 153.80 160.30
R C C
58.6631750028 1.6908142952
MMscfd MMscmd
69078.3328647979 54780 70450.5956319483 69858
Scmh Scmh Scmh Scmh
TRAIN E
LP Compressor
Cc thng s PT, TT,
Gi tr c trn HMI Cng thc tnh ca Gi tr c t
Cng thc tnh Solar FT cn tnh lu
(Solar tnh) Scada SCADA
lng ly t HMI
774.27
14437.8 4851.75
46.569708 11.6 14.20
in H2O kpa kpa
597.82398 4066 11608.00
psi kpa kpa
774.63 160.3 161.70
R C C
57.8029157818 1.7393498967
MMscfd MMscmd
68065.3417879249 71800 72472.9123612158 72143
Scmh Scmh Scmh Scmh
HP compressor
Gi tr c trn HMI Cng thc tnh ca Gi tr c t
Cng thc tnh Solar
(Solar tnh) Scada SCADA
761.7 Khng dng
7562.78 2434.71
57.007746 14.2
in H2O kpa
1706.72424 11608
psi kpa
762.39 161.7
R C
56.5906528674 1.6161713577
MMscfd MMscmd
66637.8516951916 54600 67340.4732382253 69859
Scmh Scmh Scmh Scmh