You are on page 1of 22

TOWER CRANE

1.

TOWER CRANE

2. Design Criteria
2.1 .

- .. .1008 83-:
- AISC/ASD 360- 2010 : Specification for Structural Steel Buildings
- ASCE 7-2010 : Minimum Design Loads For Buildings and Other Structures
- ACI 318-99 :
2.2

- 2,400 /...
- 7,850 /...
- 7,850 /...
- 1,800 /...

- 6( ..2527 )
..2522

2.3

- 173 /2
- 150 /2
- 173 /2
- 173 /2

24-2527 SR 24
2,400 /2

24-
2527 SD 40 4,000 /2

1227-2539 SM 400
245 MPa (2,498 /2)

2.4

- 75
- 75
- 75 ()
- 50
- 40
- 40
- 20
- 20
: DESIGN LOAD
Tower Crane
MIDAS GEN
TOWER CRANE DL + LL

SUPPORT
REACTION FZ ( Design Shear 7.10 tons at Bracing )
REACTION FY ( Design tension 8.30 T at Bracing )
REACTION FX ( Design tension 4.80 T at Bracing )

ANCHOR ROD M24 mm L = 21cm

FZ SHEAR max = 7.10 T/ 5.56 = 1.27 ANCHOR ROD 4 - M24 / JOINT

FY TENSILE max = 8.30 T/ 6.47 = 1.28 ANCHOR ROD 4 - M24 / JOINT