You are on page 1of 53

Concrete Structures

(.)

(.)

Reinforced Concrete (RC.)

Prestressed Concrete

Pre-Tensioning

Post-Tensioning

( )

()

Bonded

Unbonded

Concrete Structures :
, . (Reinforced Concrete, RC.)

Concrete Structures :
, . (Prestressed Concrete)
Pre-Tensioning

Post-Tensioning

Post-Tensioning Structures

Post-Tensioning
()

ARC245 Small-Scale Building Structural Systems


Faculty of Architecture, Rangsit University
Lecturer : Mr.Nakorn Paleethunyawong

...

Pre-Tensioning

(Prestressed Concrete)..."
Post-Tensioning

..." ???

(., Reinforced Concrete)



(Concrete)
Strength 180-240 ./..

(Formwork)
""

(Reinforcing Bars, Rebar)


2400 ./..
3000, 4000, 5000 ./..

(., Prestressed Concrete) "



(Concrete)
(Formwork)

Strength " 320 ./..


Transfer 240 ./..

""

(Prestressing Bars)
Wire, Strand
" 10,000 ./..

, .

, .

...
"
" "
Y" "
[ "
" "

Y " Y

ARC346 Building Construction 4

...
1. " (Span) " 6-15 .
2. 30-50 .
3. " , ""
4. """
5.
6. ""
7. " "
8. "Yc
9.

" ...",
, h
,
(Deformations) ", ", ",

" Span-to-Depth " ..." ,


, " (), "
"" (Precast) ...,
, , Y",
()
"
/h ""
Y"
"

2
1.

(Pre-Tensioning)
Y"



"

2.

(Post-Tensioning)
Y"


Mortar (
) " (Conduit)
" Bonded Tendon ("
" Unbonded Tendon)

"

Pre-Tensioning

Post-Tensioning

Post-Tensioning

ARC346 Building Construction 4

...
1.
2. "
3.
4. "

/ ... Pre-Tensioning

/ ... Pre-Tensioning

/ ... Pre-Tensioning

/ ... Pre-Tensioning

Post-Tensioning Slab Structures


Bonded System

Unbonded System

Post-Tension
Bonded System

Unbonded System

()

()

Bonded System

Unbonded System

()

()

Bonded System
()

PC.STRAND, ANCHORAGE,
"" GALVANIZED
STEEL GROUTING
CEMENT
" STRAND
" CEMENT GROUT "


" "
, , ,
, ,
, ,
Y

Unbonded System
()

PC.STRAND, ANCHORAGE,
""
POLYETHYLENE
STRAND "
" STRAND
"
" ANCHORAGE
2
""h
"

"
"
" "
["Y
"

Bonded System Unbonded System


"" 320 ./.. (Cylinder) 28 "
" 240 ./.. (Cylinder) (Stressing)
( PC Strand ) Y 7- Wire Stress Relieved Uncoated Strand Grade 270 k
Low Relaxation "h 12.7 . ( 1/2 ) ASTM A416 .420

Bonded Tendon

Unbonded Tendon

" Corrugated Duct


Galvanized
Steel Strip "" 0.3 .
Y
" Bonding
"
Grouting Portland Cement
Type 1

(PC Stand)
" Extruder "
Lithium Base
" High Density
Polyethylene
"" 1 ."
"

" Post-Tensioning
1 "

" Post-Tensioning
2 " "

" Post-Tensioning
3 PC Strand Profile

" Post-Tensioning

" Post-Tensioning
4 "

" Post-Tensioning
5

" Post-Tensioning
6 (Stressing) Compressive Strength "" 240 ksc.

" Post-Tensioning
7 Stressing "
" "Y

" Post-Tensioning
8 Grouting ( Bonded Tendon )

Post-Tensioning

" h...

Post-Tensioning
Punching Shear ()

Drop Panel

Column Capital

Post-Tensioning

Post-Tensioning

Floor to Floor

Floor to Floor

" "...

" "...

Post-Tensioning

L/45

L/25

" "...
"" 9 . Post-Tension Y... 900/45 = 20 .

Post-Tensioning

1. Flat Slab
L/4
L/2

L/4

"" ()...
5.0-8.0 .
" Y
: "
1:1.5

Post-Tensioning

" 10 %
" "

Post-Tensioning

2. Drop Panel
c (Drop Panel) c "
()... 5.0-14.0 .

L/4
L/2

t
L/4

L/3
t/4

Post-Tensioning

You might also like