Professional Documents
Culture Documents
Product Catalogue
E 57.000.0/ 03.15
HYDAC Cooling
with Global Reach
2
Contents
Page
Feed Pumps
llFZP, MFZP149
llVP, VPB, VPBM159
3
Your Partner for Expertise
in Sustainable Solutions
PM
HYDAC Cooling Modules for Engines of all Emission Levels
0.400 As a result of the increased requirements concerning energy efficiency and
noise development in mobile machines, cooling systems for these vehicles
have to be designed to the limits of physical possibility.
0.100 Stage IIIA/tier IIIA
(37 p < 75 kW) By combining multiple cooling circuits, integrating functions
(such as tank and filter functions) and using electrical and hydraulic fan controls,
HYDAC mobile coolers are well-equipped to deal with all requirements.
4
Research and Development
for Intelligent Solutions
Design Programs
and the KULI Simulation Software
To help you to find the perfect cooling solution for your particular requirements,
you can make use of the design software Cool-IT or the design program for
soldered plate heat exchangers. This is important because only correctly configured
components can provide an efficient cooling that saves energy, reduces strain
to your budget by minimizing Life Cycle Costs and extends the operational reliability
of your systems.
We can gladly assign you a specific HYDAC contact to help you with optimizing
your design to suit your needs.
Test bench for pressure pulsation Thermal shock test bench Wind tunnel
5
Industries and Applications
in Stationary Equipment
Industries
llPower plant technology
llOil and gas industry
llPlastic injection moulding machines
llForming machines
llIron and steel
llTransformers
llMining and tunnelling
llPaper industry
llShipping
llTest benches
llSolar power
llHydroelectric power
Applications
llHydraulic cooling
llGearbox cooling and lubrication
llBearing cooling and lubrication
llGenerator, inverter, transformer cooling
llEngine cooling
llCooling electric drives
llControl cabinet cooling
6
Industries and Applications
in Mobile Technology
Industries
Construction machinery
llWheel loaders
llExcavators
llRoad construction machinery
llTelescopic cranes
llTelescopic loaders
llMaterials handling
Municipal machines
Agricultural and forestry machines
llTractors
llField sprayers
llCombine harvesters
llHarvesters
Applications
Cooling of
llHydraulic oil
llGear oil
llRefrigerant
llCharge air
llFuel
7
Industries and Applications
for Machine Tools
Applications
llCooling of AC main drives
llCooling of motor spindles in processing machines
llFluid-cooled drives
llInverter cooling
llGearbox cooling
llCooling lubricant cooling
8
Industries and Applications
in Wind Energy
Applications
llSystem consultation and design
(also for extreme climate zones CCV and HCV)
llCooling and lubrication of gearboxes
llGenerator cooling
llCombined cooling of the gearbox and generator
llInverter cooling
Generator cooling
llWater glycol circuit
with air cooler or passive cooling element
Inverter cooling
llWater glycol circuit with air cooler
9
Air Coolers for
Stationary Industrial Applications
AC-LN 1-7
llStandard air cooler with axial fan 1 50 kW
ACA-LN 2-7
llAir cooler with pump
ACAF-LN 2-7
llAir cooler with pump and filter
AC-LN 8-14
llLow-noise air cooler with axial fan 50 200 kW
ACA-LN 8-11
llAir cooler with pump
ACAF-LN 8-11
llAir cooler with pump and filter
AC-LN MI 8-14
llLow-noise air cooler with axial fan 50 230 kW
llWith integrated frequency inverter
llContinuously adjustable speed-control in accordance
with the fluid temperature in the cooling element
llRegulated cooling capacity
OSCA/OSCAF 0-3
llOptimized air cooler with radial fan 1 16 kW
llOSCA: air cooler with pump
llOSCAF: air cooler with pump and filter
OK-ELC 0-7
llOil/air cooler 1 34 kW
llCompact motor-fan unit
ATEX version
llII 2G/ D de IIC T4
llFor 50 Hz and 60 Hz
llAvailable for AC-LN, AC-LNH, OK-ELH
E 5.700.6/ 03.15
10
Model/description
Accessories
llIntegrated bypass valve with pressure or temperature function
llThermostats
llAir filter grid/air filter mat
llVibration damper
llHydraulic and electric fan controllers
OK-ELD 0-6
llAir cooler with DC motor (12 V and 24 V) 2 34 kW
llCompact and performance-optimized
llCooling of oils or coolants
11
Plate Heat Exchanger
Model/description
Hxxx-LIQUID
llGasketed plate heat exchangers
llHeat exchanger plates made from stainless steel or titanium
llGaskets: NBR, Viton, EPDM
Pump-Transfer Cooler
Filtration Units
12
Feed Pumps
FZP, MFZP
ll(Motor) vane pump max. 6 bar
llIn direct drive version
llOutput: 5 200 l/min
Filling pumps
llFor hydraulic oil or diesel fuel
E 5.700.6/03.15
13
Cooling Systems
FLKS
llFluid/air cooling system up to 1.2 kW/K
llOperating fluid water glycol or mineral oil
llOptionally with speed control
FWKS
llFluid/water cooling system up to 100 kW
llOperating fluid water glycol or mineral oil
llOptionally with water control valve or electronic controller
RFCS
llCompressor cooling system up to 135 kW
llTo cool the fluid to ambient temperature or below
Higher cooling
capacities possible
as special design
HCC
llControl cabinet cooling system up to 15 kW
llPassive or active cooling systems
llFor roof installation or wall/door mounting
E 5.700.6/ 03.15
14
HYDAC Cooling Systems
Provide Certainty Thanks
to ...
Quality
In all the cooler components,
priority is given to high quality standards.
For this reason, our coolers undergo
a series of tests before being released
for market launch.
Reliability
As a high percentage of components are
produced in-house for each product,
high operational reliability is guaranteed.
Our expertise in design, sales and
service ensures that all functions are
able to run smoothly.
E 5.700.6/03.15
15
16
E 5.700.6/ 03.15
Air Coolers
Industrial / Mobile
Herringbone [mm]
Agricultural Machines
ANTI-CLOGGING
17
Production of cooling elements
18
Test rigs
Field measurements or tests carried out under real-life HYDAC test rigs fulfill all requirements in terms
conditions are important methods to analyse the cooler of testing accuracy and have been certified
performance and suitability for specific applications. by TV Sd.
Constancy and accuracy of the instruments used
for measurments are essential requirements. The test criteria and the testing equipment to be used
Only in thus way changes in the cooling system, are specified in the test procedures. The cooling capacity
e.g. the position of the fan in the fan housing, values indicated by HYDAC were derived following
can be accurately quantified. the specification EN 1048.
Further tests:
Wind tunnel
Carried out in order to determine the performance data of cooling element
combinations and to provide a database for cooler calculation using
the simulation software KULI.
ll Noise measurement
ll Vibration tests
ll Burst test
E 5.823.0/03.15
ll Leakage test
ll Corrosion tests in the salt spray chamber
ll Cold chamber
ll Thermal imaging camera
19
Development
Since product life cycles get shorter, it is necessary to develope cooling systems. Its purpose is to solve any given fluid
multiple realiable versions of a new cooler design as soon dynamic or thermodynamic problem using numerical methods.
as possible. Technical simulation plays an essential role For example, CFD can be used to analyse the effects
here because it helps reduce development costs and times. of real, customer-specific installation situations on the cooler
Moreover, simulation as part of the development process results performance.
in more accurate design and optimization, long before the
Finally the FEM method, i.e. the numerical analysis
prototypes are produced. Last but not least,real-life tests can
of problems in structural mechanics and thermal mechanics,
be kept to an absolute minimum.
is an important tool in development-stage simulation.
With KULI software is possible to assess the heat management Above all, it is used to assess structural stress and reduce
of a machine as a whole. But it can also be used to design hot spot stress in order to extend service life.
individual coolers or heat exchangers. By simulating various
A team of development engineers by HYDAC works
heat balances of individual components based on the
with the simulation methods depicted above in order
measurement data of a model heat exchanger in the wind
to optimise existing components and systems and to identify
tunnel, reliable coolers and cooling systems are the results.
new approaches to solutions, including custom solutions.
In addition to KULI, computational fluid dynamics (CFD) are
an important method to optimise coolers, heat exchangers and
Kuli software
Rapid and accurate prediction of cooling capacities. Simulations of passive cooling elements
Simulations of complete air coolers Simulations of air coolers in particular installation spaces
E 5.823.0/ 03.15
20
Air Coolers for all Applications
Industrial
Corrosion protection
Medium: Mineral oil
Three-phase motor
Cooling capacity
Hydraulic motor
Speed control
pump + filter
With pump /
Radial fan
DC motor
Axial fan
ATEX
CPL
up to
AC-LN
200 kW
OSCA / up to
OSCAF 16 kW
up to
OK-ELC *
34 kW
up to
AC-LN MI
250 kW
Mobile
up to
OK-ELD
34 kW
OK-ELH / up to
AC-LNH 140 kW
Oil,
Combin-
To customer water-glycol,
E 5.823.0/03.15
ation cooler
specification fuel,
CMS
charge air
21
and all Industries
Industry
Mobile
of these products and improve the environmental performance through Ecodesign. EU-wide standards are
defined for each product group for this purpose.
In this case, the required dissipation is determined for systems and machines that are
already in operation by first measuring the temperature increase in the medium over
a defined time period (but before the temperature stabilises). The heat load of the
system can be determined from the available data.
Example:
The oil temperature in a system increases from 20 C to 60 C over a period
of 30 minutes, the tank capacity is 400 l.
Calculation of the cooling capacity:
V 400 [l]
T (60-20) = 40 [C]
t 30 [min]
T1 60 [C]
T2 30 [C]
PV 15.3
P01 = = = 0.51 [kW/K]
T1 T2 6030
With 5 % safety margin (to allow for contamination), the specific cooling capacity
P01 x 1.05 = 0.53 [kW/K]
E 5.823.0/03.15
52 1.3
7S
48 1.2
44 1.1
40 1.0
36 7L 0.9
Heat dissipation [kW] at T = 40 C
28 0.7
6S
24 0.6
5S
20 6L 0.5
16 5L 0.4
4S
3H
12 0.3
4L
8 3S 0.2
2H
2S
4 0.1
1H
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340
Oil-flow [l/min]
Tolerance: 5 %
E 5.823.0/ 03.15
24
Sizing Software
Our design software, HYDAC Cool IT, was developed in order to speed up
and simplify selection from the HYDAC air cooler range.
You can also use our Specification sheet for air coolers in order to ensure you have
all of the necessary data to hand.
Contact our Technical Sales Office for further details.
E 5.823.0/03.15
25
Specification Sheet for Air Coolers
Please contact the Technical Sales Office for your customised combination cooler (CMS) design.
Project:
Contact:
Telephone:
E-mail:
Application:
Design data
Medium:
Version
Max. possible unit dimensions: mm HxWxD
26
Specification Sheet AC-LN 8-14 MI with Speed Control
Project:
Contact:
Phone:
E-mail:
Application:
Cooler type:
Data required
fmax
Fan speed [Hz]
Tmax Temperature at which the frequency converter switches to the highest speed
fmin
Toff* Temperature at which the frequency converter switches off the fan
Motor 1
Tmin C fmin rpm
Toff C
Toff C
Note
The temperature must between +20 C and + 85 C.
* Toff:
Ensure a slight hysteresis between Tmin and Toff in order to prevent the fan switching on and off continuously at low temperatures.
The hysteresis will vary depending on the environment and the system, usually a few degrees Celsius is sufficient.
27
Note
The information in this brochure
relates to the operating conditions.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications.
28
Air Cooler Industry
AC-LN 1-7 / ACA-LN 2-7 /
ACAF-LN 2-7
29
Application Field Design
Systems with small and medium AC-LN 1
cooling requirements, such as:
ll Hydraulic systems
ll Lubrication systems
ll Gears
ll Motors
ll Generators
ll Converters
ll Machine tools
Options
Integrated pressure bypass valve
(IBP) / Integrated thermal pressure
bypass valve (IBT) 3
4
The bypass channel is integrated in the
cooling element. If a particular pressure
is exceeded, the IBP opens the bypass
channel, thereby protecting the cooling 2
element from too high a pressure.
Furthermore, the IBT only opens the
cooling element path once a particular
temperature has been reached.
ATEX 1
The AC-LN (without pump and filter) 1 Axial fan with integrated motor
is also available for operation in gas 2 Fan housing
and dust explosive areas. The ATEX 3 Heat exchanger
certification applies for a frequency of
4 Electrical box
50 Hz and 60 Hz.
Marine
The MAR version is for aggressive
ambient conditions, such as industrial AC-LN 2-3-4-5-6
atmospheres, high humidity or high salt
content, which place great demands on
the corrosion resistance and robustness
of the materials used.
Cold Climate/Hot Climate
Use in extreme ambient conditions:
Cold Climate to - 40 C,
Hot Climate to + 60 C
1 3
1 Drive motor
E 5.816.0/ 03.15
2 Axial fan
3 Fan housing
4 Heat exchanger
30
Design
AC-LN 7
1 Drive motor
2 Axial fan
4 3 Fan housing
4 Heat exchanger
3
2 1
ACA-LN 2-6
1 Drive motor
2 Low-noise pump*
3 Axial fan
4 Fan housing
E 5.816.0/03.15
5 Heat exchanger
31
Design
ACA-LN 7
1 Drive motor
5
2 Axial fan
3 Low-noise screw pump
4 Fan housing
5 Heat exchanger
4
1
2 3
ACAF-LN 2-6
1 Drive motor
2 Low-noise pump*
3 Axial fan
4 Fan housing
5 5 Heat exchanger
6 Filter
6
2
3 1
E 5.816.0/ 03.15
32
Design
ACAF-LN 7
1 Drive motor
2 Axial fan
3 Low-noise screw pump
4 Fan housing 5
5 Heat exchanger
4
6 Filter
6
1
3
E 5.816.0/03.15
33
Technical Data
AC-LN
Weight [kg] 6)
[kW / A] 4)
[kW / A] 4)
Volume [l] 5)
Noise level
Fan motor:
Fluid [-] 1)
P/N
kW A kW A
AC-LN1H 3849085 F 120 650 - 0.03 0.23 0.03 0.21 60 0.3 7
AC-LN2S 3860765 F 180 900 4/63/B5 0.18 0.66 0.20 0.75 64 0.7 14
AC-LN2H 3860702 F 180 1,850 2/63/B5 0.25 0.76 0.30 0.76 80 0.7 14
AC-LN3S 3860382 F 180 1,400 4/63/B5 0.18 0.66 0.20 0.75 66 1.0 20
AC-LN3H 3860308 F 180 2,900 2/71/B14 0.55 1.21 0.66 1.50 85 1.0 20
AC-LN4L 3859982 F 200 1,600 6/71/B5 0.25 0.90 0.28 0.80 63 2.3 32
AC-LN4S 3860090 F 200 2,250 4/71/B5 0.37 1.20 0.40 1.10 72 2.3 32
AC-LN5L 3860913 F 250 2,050 6/80/B5 0.37 1.25 0.41 1.15 65 2.8 42
AC-LN5S 3860907 F 250 3,200 4/90/B5 1.10 2.60 1.30 2.20 75 2.8 45
AC-LN6L 3856579 F 250 2,800 6/80/B5 0.37 1.25 0.41 1.15 67 4.6 52
AC-LN6S 3859080 F 250 4,250 4/90/B5 1.10 2.60 1.30 2.20 77 4.6 52
AC-LN7L 3909026 F 300 4,800 6/90/B14 1.10 2.70 1.30 2.70 76 5.2 58
AC-LN7S 3909027 F 300 8,200 4/100/B14 3.00 6.00 3.60 7.20 84 5.2 63
1)
Medium: F = mineral oil or water-glycol, M = mineral oil
2)
Max. flow rate
3)
Air flow data at 50 Hz
4)
AC-LN1: each motor
5)
Fluid in cooling element
6)
Unfilled
E 5.816.0/ 03.15
34
Technical Data
ACA-LN / ACAF-LN
absorption [kW / A] 4)
Max. Viscosity [mm2/s]
continuous working 3)
power / current
Fluid flow [l/min] 2)
[kW / A] 4)
Weight [kg] 6)
Filter size [-]
Volume [l] 5)
Noise level
Fan motor:
Fluid [-] 1)
kW A kW A
ACA-LN2S M 13 900 10 500 4/71/B5 0.37 1.20 0.40 1.10 - 64 0.7 21
ACA-LN2H M 27 1,850 10 500 2/80/B5 1.50 3.10 1.80 3.10 - 80 0.7 21
ACAF-LN2S M 13 900 10 500 4/71/B5 0.37 1.20 0.40 1.10 LPF160 64 0.7 22
ACAF-LN2H M 27 1,850 10 500 2/80/B5 1.50 3.10 1.80 3.10 LPF160 80 0.7 22
ACA-LN3S M 36 1,400 28 500 4/90/B5 1.10 2.60 1.30 2.60 - 66 1.0 35
ACA-LN3H M 72 2,700 28 500 2/90/B5 2.20 4.50 2.6 4.5 - 85 1.0 35
ACAF-LN3S M 36 1,400 28 500 4/90/B5 1.10 2.60 1.30 2.60 LPF160 66 1.0 36
ACAF-LN3H M 72 2,700 28 500 2/90/B5 2.20 4.50 2.6 4.5 LPF160 85 1.0 36
ACA-LN4L M 24/34 1,600 28/40 350 6/90/B5 1.10 2.65 1.30 2.25 - 63 2.3 35
ACA-LN4S M 36/52 2,250 28/40 350 4/90/B5 1.80 3.70 2.10 3.60 - 72 2.3 35
ACAF-LN4L M 24/34 1,600 28/40 350 6/90/B5 1.10 2.65 1.30 2.25 LPF160 67 2.3 41
ACAF-LN4S M 36/52 2,250 28/40 350 4/90/B5 1.80 3.70 2.10 3.60 LPF160 72 2.3 41
ACA-LN5L M 24/34 2,050 28/40 350 6/90/B5 1.10 2.65 1.30 2.25 - 65 2.8 45
ACA-LN5S M 36/52 3,200 28/40 350 4/90/B5 1.80 3.70 2.10 3.60 - 75 2.8 45
ACAF-LN5L M 24/34 2,050 28/40 350 6/90/B5 1.10 2.65 1.30 2.25 LPF160 65 2.8 52
ACAF-LN5S M 36/52 3,200 28/40 350 4/90/B5 1.80 3.70 2.10 3.60 LPF160 77 2.8 52
ACA-LN6L M 24/34 2,800 28/40 350 6/90/B5 1.10 2.65 1.30 2.25 - 67 4.6 55
ACA-LN6S M 36/52 4,250 28/40 350 4/90/B5 1.80 3.70 2.10 3.60 - 77 4.6 55
ACAF-LN6L M 24/34 2,800 28/40 350 6/80/B5 1.10 2.65 1.30 2.25 LPF160 67 4.6 62
ACAF-LN6S M 36/52 4,250 28/40 350 4/90/B5 1.80 3.70 2.10 3.60 LPF160 77 4.6 62
ACA-LN7L M 100/150/180 4,800 40/58/69 320/130/240 6/90/B14 1.10 2.70 1.30 2.70 - 76 5.2 74
ACA-LN7S M 100/150/180 8,200 40/58/69 320/130/240 4/100/B14 3.00 6.00 3.60 7.20 - 84 5.2 74
ACAF-LN7L M 100/150/180 4,800 40/58/69 320/130/240 6/90/B14 1.10 2.70 1.30 2.70 LPF280 76 5.2 82
ACAF-LN7S M 100/150/180 8,200 40/58/69 320/130/240 4/100/B14 3.00 6.00 3.60 7.20 LPF280 84 5.2 82
1)
Medium: F = mineral oil or water-glycol, M = mineral oil
2)
Fluid and air flow data at 50 Hz
3)
Depends on pump displacement
4)
For the size 7 the power / current absorption data are those of the fan motor.
For the pump motor on feet refer to the following data:
40/58 cm3/U 3 [kW] / 6.7 [A]
69 cm3/U 5.5 [kW] / 10.4 [A]
5)
Fluid in cooling element
6)
Unfilled
35
Cooling Capacity and Pressure Difference p
Mineral oil
Cooling capacity:
Dependent on the oil flow rate and the
52 1.3
temperature difference T between oil
7S
48 1.2 inlet and air inlet.
44 1.1
Note:
40 1.0 The values are measured at
Heat dissipation [kW] at T = 40 C
8 3S 0.2
2H
4 2S 0.1
1H
0 0.0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340
Pressure difference p
3.5
1H 3S-H
3.0
2S-H
2.5
Pressure drop [bar]
2.0
7L-S
4L-S 5L-S
1.5
6L-S
1.0
0.5
0.0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340
Measured at 30 mm/s
Tolerance: 5 %
36
Cooling Capacity and Pressure Difference p
Water-glycol (60/40)
AC-LN
Cooling capacity:
Dependant on the water-glycol flow
42 1.4 rate and the temperature difference
39 7S 1.3 T between w/g inlet and air inlet.
36 1.2 Note:
33 1.1 The values are measured at
Heat dissipation [kW] at T = 30 C
Pressure difference p
1,400
1,300 1H
1,200
1,100
1,000
Pressure drop [mbar]
900 3S-H
800 2L-S
700
600
5L-S
500 4S-L 7L-S
400 6L-S
300
200
100
0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340
Measured at 2 mm/s
Tolerance: 5 %
E 5.816.0/03.15
37
Model Type
ACAF-LN 4S-40-1.0-B-M-A-LPF160-10-1-IBT
Cooler type
AC-LN = Air cooler (oil / water-glycol mix)
ACA-LN = Air cooler (oil) with integrated pump
ACAF-LN = Air cooler (oil) with integrated pump and filter
Size / motor speed
1-7 = Size
L = 6 poles (1,000 rpm)
S = 4 poles (1,500 rpm)
H = 2 poles (3,000 rpm)
Displacement cm3/rev
10 = Screw pump (ACA-LN / ACAF-LN2)
28 = Screw pump (ACA-LN / ACAF-LN3)
28 = Vane pump (ACA-LN / ACAF-LN4-6)
40 = Vane pump (ACA-LN / ACAF-LN4-6)
40/58/69 = Screw pump (ACA-LN / ACAF-LN 7)
Revision
Clogging indicators (only ACAF-LN)
A = Without clogging indicator
B = With visual indicator (Standard)
D = With electrical and optical indicator
Fluids
F = Mineral oil or water glycol mix (AC-LN)
M = Mineral oil (ACA-LN and ACAF-LN)
Motor voltage
Standard voltages and frequencies for 3 phase motor
A = 230/400 V 50 Hz / 265/460 V 60 Hz
B = 230/400 V 50 Hz
C = 265/460 V 60 Hz
AC-LN1 = 220-240 V 50/60 Hz, single phase (Standard)
(tolerance voltage 10 %)
Other voltages on request.
Size of filter (only ACAF-LN)
LPF160 = ACAF-LN2-6
LPF280 = ACAF-LN7
Filtration rating in micron (only ACAF)
5 = 5 m Betamicron-4-N (5 BN4HC)
10 = 10 m Betamicron-4-N (10 BN4HC) (Standard)
20 = 20 m Betamicron-4-N (20 BN4HC)
Color
1 = RAL 9002 (Standard)
Other colors on request.
Accessories
IBP = Heat exchanger with integrated bypass valve
IBT = Heat exchanger with integrated thermo-bypass valve
AITF = Thermostat (fixed)
For all possible accessories, like vibration absorber, air filter grid or
air filter mat please refer to brochure Accessories for air coolers.
E 5.816.0/ 03.15
38
Dimensions
AC-LN 1
A/2 A/2
256 10 B
Air
E1
A
Air
(4x) F
E2
Z1 (2x)
D2 E3
C D1
D3
AC-LN 2-6
B
A/2 A/2
Z1 (3x)
E1
Air
A
Z3
(4x) F
PLUG
D2 E3
E2
C D1
D3
A B C D1 D2 D3 E1 E2 E3 F Z1 Z3
10 25 10 2 2 2 5 5 5 Slot
AC-LN1H 355 143 200 255 150 295 288 41 88 9 G3/4" -
AC-LN2H 355 401 330 255 160 295 289 41 58 9 G3/4" -
AC-LN2S 355 396 330 255 160 295 289 41 58 9 G3/4" -
AC-LN3H 455 438 380 255 290 295 388 41 58 9 G3/4" -
AC-LN3S 455 404 380 255 290 295 388 41 58 9 G3/4" -
AC-LN4L 520 517 485 410 425 450 439 51 104 9x20 G1" -
AC-LN4S 520 517 485 410 425 450 439 51 104 9x20 G1" -
AC-LN5L 562 547 542 410 482 450 439 72 94 9x20 G1" -
E 5.816.0/03.15
AC-LN5S 562 563 542 410 482 450 439 72 94 9x20 G1" -
AC-LN6L 640 567 584 410 482 450 497 82 74 9x20 G1 1/4" M22x1.5
AC-LN6S 640 583 584 410 482 450 497 82 74 9x20 G1 1/4" M22x1.5
39
AC-LN 7
A/2 A/2
B
Z1 (3x)
Air
A
E1
Z3
(4x) Slot F
E3 D2
PLUG
E2
D1 C
D3
A B C D1 D2 D3 E1 E2 E3 F Z1 Z3
10 25 10 2 2 2 5 5 5 Slot
AC-LN7L 726 593 706 410 560 450 597 75 74 9x20 G1 1/4" M22x1.5
AC-LN7S 726 613 706 410 560 450 597 75 74 9x20 G1 1/4" M22x1.5
ACA-LN 2-6
A/2 A/2
C1 B
Z2 (OUT)
Rotation Z1 (IN)
Air
E1
A
(4x) Slot F
Z3
PLUG
E2
D2 E3
C D1
D3
A B C C1 D1 D2 D3 E1 E2 E3 F Z1 Z2 Z3
10 30 10 25 2 2 2 5 5 5 Slot (IN) (3x)
ACA-LN2S 355 567 330 414 370 160 410 289 41 58 9 G 1" G 3/4" -
ACA-LN2H 355 596 330 414 370 160 410 289 41 58 9 G 1" G 3/4"
ACA-LN3S 455 620 380 462 370 290 410 388 41 58 9 G 1" G 3/4" -
ACA-LN3H 455 620 380 462 370 290 410 388 41 58 9 G 1" G 3/4" -
ACA-LN4L 520 697 485 574 410 425 450 439 51 104 9x20 G1 1/4" G1" -
ACA-LN4S 520 699 485 574 410 425 450 439 51 104 9x20 G1 1/4" G1" -
ACA-LN5L 562 707 542 641 410 482 450 439 71.5 94 9x20 G1 1/4" G1" -
E 5.816.0/ 03.15
ACA-LN5S 562 709 542 641 410 482 450 439 71.5 94 9x20 G1 1/4" G1" -
ACA-LN6L 640 727 584 717 410 482 450 497 81.5 74 9x20 G1 1/4" G1 1/4" M22x1.5
ACA-LN6S 640 729 584 717 410 482 450 497 81.5 74 9x20 G1 1/4" G1 1/4" M22x1.5
40
ACA-LN 7
A/2 A/2
B C1
Z2 (OUT)
Air
E1
A
Z3
E2
(4x) Slot F E3 PLUG Z1 (IN)
D1 D2
D3 C
A B C C1 D1 D2 D3 E1 E2 E3 F Z1 Z2 Z3
10 30 10 25 2 2 2 5 5 5 Slot (IN) (3x)
ACA-LN7L 736 593 706 775 5601) 560 6001) 600 83 74 9x20 G 2" G1 1/4" M22x1.5
ACA-LN7S 736 607 706 775 560 1)
560 600 1)
600 83 74 9x20 G 2" G1 1/4" M22x1.5
1)
Version with pump displacement 69 [cm/U]: D1 = 830, D3 = 870
ACAF-LN 2-6
A/2 A/2
C1 B
Z2 (OUT)
Rotation Z1 (IN)
E1
A
Air
(4x) Slot F
Z3
PLUG
E2
D2 E3
C D1
D3
A B C C1 D1 D2 D3 E1 E2 E3 F Z1 Z2 Z3
10 30 10 25 2 2 2 5 5 5 Slot (IN) (3x)
ACAF-LN2S 355 567 330 467 370 160 410 289 41 58 9 G 1" G 3/4" -
ACAF-LN2H 355 596 330 467 370 160 410 289 41 58 9 G 1" G 3/4"
ACAF-LN3S 455 620 380 517 370 290 410 388 41 58 9 G 1" G 3/4" -
ACAF-LN3H 455 596 380 517 370 290 410 388 41 58 9 G 1" G 3/4" -
ACAF-LN4L 520 697 485 619 410 425 450 439 51 104 9x20 G1 1/4" G1" -
ACAF-LN4S 520 699 485 619 410 425 450 439 51 104 9x20 G1 1/4" G1" -
ACAF-LN5L 562 707 542 676 410 482 450 439 71.5 94 9x20 G1 1/4" G1" -
E 5.816.0/03.15
ACAF-LN5S 562 709 542 676 410 482 450 439 71.5 94 9x20 G1 1/4" G1" -
ACAF-LN6L 640 727 584 734 410 482 450 497 81.5 74 9x20 G1 1/4" G1 1/4" M22x1.5
ACAF-LN6S 640 729 584 734 410 482 450 497 81.5 74 9x20 G1 1/4" G1 1/4" M22x1.5
41
ACAF-LN 7
A/2 A/2
B C1
Z2 (OUT)
Air
E1
A
Z3
E2
(4x) Slot F E3 PLUG D2 Z1 (IN)
D1 C
D3
A B C C1 D1 D2 D3 E1 E2 E3 F Z1 Z2 Z3
10 30 10 25 2 2 2 5 5 5 Slot (IN) (3x)
ACAF-LN7L 736 593 706 775 5601) 560 6001) 600 83 74 9x20 G 2" G1 1/4" M22x1.5
ACAF-LN7S 736 607 706 775 560 1)
560 600 1)
600 83 74 9x20 G 2" G1 1/4" M22x1.5
1)
Version with pump displacement 69 [cm/U]: D1 = 830, D3 = 870
Note: Note
We recommend maintaining a minimum
The information in this brochure
distance to ensure an unimpeded air
relates to the operating conditions
inlet and air outlet. This is half the
and applications described.
height of the cooling element (A/2).
Anything below the minimum distance For applications and operating conditions
can influence the cooling capacity and not described, please contact the
the noise emissions. relevant technical department.
Subject to technical modifications.
42
Air Cooler Industry
AC-LN 8-14 / ACA-LN 8-11 /
ACAF-LN 8-11
43
Application Field Design
Systems with high cooling AC-LN 8-9-10-11
requirements, such as:
ll Hydraulic systems
ll Lubrication systems
ll Gears
ll Motors
ll Generators
ll Converters
ll Machine tools
Options
Integrated pressure bypass valve
(IBP) / Integrated thermal pressure
bypass valve (IBT)
The bypass channel is integrated 1 Motor
in the cooling element. If a particular
2 Axial fan
pressure is exceeded, the IBP opens
the bypass channel, thereby protecting 3 Fan housing
the cooling element from too high 4 Heat exchanger
a pressure. Furthermore, the IBT only
opens the cooling element path once
a particular temperature has been
reached. 4
Large coolers
Coolers with a higher cooling capacity 1
than standard are also available as 3
2
special versions.
Speed control: AC-LN MI
The integrated frequency converter
enables stepless speed control
dependent on the oil temperature AC-LN 12-14
in the cooling element.
ATEX
The AC-LN (without pump and filter)
is also available for operation in gas
and dust explosive areas. The ATEX
certification applies for a frequency
of 50 Hz and 60 Hz.
Marine
The MAR version is for aggressive
ambient conditions, such as industrial
atmospheres, high humidity or high
salt content, which place great
demands on the corrosion resistance
and robustness of the materials used. 4
1 Motor
E 5.814.0/ 03.15
2 Axial fan
3 Fan housing
4 Heat exchanger
44
Design
ACA-LN8-9-10-11
1 Drive motor
2 Axial fan
3 Low-noise screw pump
4 Fan housing
2
5 Heat exchanger
ACAF-LN8-9-10-11
4
2
1 3
6
45
Technical Data
AC-LN
50 Hz) [dB(A)]
Weight [kg] 5)
Volume [l] 4)
Fan motor:
Fluid [-] 1)
P/N
VERSION B: 50 Hz
AC-LN8L 3686293 F 350 5,800 6/90/B14 0.75 / 2.0 68 6 72
AC-LN8S 3686305 F 350 8,700 4/90/B14 1.5 / 3.3 79 6 72
AC-LN9L 3686306 F 350 7,500 6/90/B14 0.75 / 2.0 67 11 100
AC-LN9S 3770160 F 350 10,900 4/90/B14 1.5 / 3.3 80 11 100
AC-LN10L 3686307 F 540 11,300 6/90/B14 1.1 / 2.65 71 14 129
AC-LN10S 3773324 F 540 16,500 4/100/B14 3.0 / 6.0 77 14 129
AC-LN11L 3686308 F 540 17,400 6/112/B14 2.2 / 4.6 75 18 170
AC-LN11S 3773334 F 540 23,600 4/112/B14 4.0 / 7.7 81 18 170
AC-LN12L 3704261 F 840 22,600 6/90/B14 1.1 / 2.65 74 28 290
AC-LN12S 3773864 F 840 33,000 4/100/B14 3.0 / 6.0 80 28 290
AC-LN14L 3704260 F 840 34,800 6/112/B14 2.2 / 4.6 78 35 320
AC-LN14S 3773890 F 840 47,200 4/112/B14 4.0 / 7.7 84 35 320
VERSION C: 60 Hz
AC-LN8L 3763003 F 350 6,150 6/90/B14 0.9 / 2.0 71 6 72
AC-LN8S 3763036 F 350 8,700 4/90/B14 1.8 / 3.3 83 6 72
AC-LN9L 3763004 F 350 7,500 6/90/B14 0.9 / 2.0 70 11 100
AC-LN9S 3772994 F 350 10,900 4/90/B14 1.8 / 3.3 83 11 100
AC-LN10L 3733086 F 540 12,000 6/90/B14 1.3 / 2.7 74 14 129
AC-LN10S 3774291 F 540 16,400 4/100/B14 3.6 / 7.2 80 14 129
AC-LN11L 3763035 F 540 18,300 6/112/B14 2.6 / 4.6 78 18 170
AC-LN11S 3774293 F 540 23,600 4/112/B14 4.8 / 8.0 84 18 170
AC-LN12L 3765763 F 840 24,000 6/90/B14 1.3 / 2.7 77 28 290
AC-LN12S 3774304 F 840 32,800 4/100/B14 3.6 / 7.2 83 28 290
AC-LN14L 3765740 F 840 36,600 6/112/B14 2.6 / 4.6 81 35 320
AC-LN14S 3774312 F 840 47,200 4/112/B14 4.8 / 8.0 87 35 320
1)
Medium: F = mineral oil or water-glycol, M = mineral oil
2)
Max. flow rate
3)
Current requirement: B version at 400 V 50 Hz / C version at 480 V 60 Hz, AC-LN 12-14: each motor
4)
Fluid in cooling element
5)
Unfilled
E 5.814.0/ 03.15
46
Technical Data
ACA-LN / ACAF-LN
50 Hz) [dB(A)]
[kW/A] 3)
Weight [kg] 5)
Filter size [-]
Volume [l] 4)
Fan motor:
Fluid [-] 1)
40/58 69
VERSION B: 50 Hz
ACA-LN8L M 100/150/180 5,800 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/90/B14 0.75 / 2.0 - 68 6 102
ACA-LN8S M 100/150/180 8,700 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/90/B14 1.5 / 3.3 - 79 6 102
ACAF-LN8L M 100/150/180 5,800 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/90/B14 0.75 / 2.0 LPF280 68 6 110
ACAF-LN8S M 100/150/180 8,700 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/90/B14 1.5 / 3.3 LPF280 79 6 110
ACA-LN9L M 100/150/180 7,500 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/90/B14 0.75 / 2.0 - 67 11 132
ACA-LN9S M 100/150/180 10,900 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/90/B14 1.5 / 3.3 - 80 11 132
ACAF-LN9L M 100/150/180 7,500 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/90/B14 0.75 / 2.0 LPF280 67 11 140
ACAF-LN9S M 100/150/180 10,900 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/90/B14 1.5 / 3.3 LPF280 80 11 140
ACA-LN10L M 100/150/180 11,300 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/90/B14 1.1 / 2.65 - 71 14 172
ACA-LN10S M 100/150/180 16,500 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/100/B14 3.0 / 6.0 - 77 14 172
ACAF-LN10L M 100/150/180 11,300 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/90/B14 1.1 / 2.65 LPF280 71 14 180
ACAF-LN10S M 100/150/180 16,500 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/100/B14 3.0 / 6.0 LPF280 77 14 180
ACA-LN11L M 100/150/180 17,400 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/112/B14 2.2 / 4.6 - 75 18 212
ACA-LN11S M 100/150/180 23,600 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/112/B14 4.0 / 7.7 - 81 18 212
ACAF-LN11L M 100/150/180 17,400 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/112/B14 2.2 / 4.6 LPF280 75 18 220
ACAF-LN11S M 100/150/180 23,600 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/112/B14 4.0 / 7.7 LPF280 81 18 220
VERSION C: 60 Hz
ACA-LN8L M 120/180/215 6,150 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/90/B14 0.9 / 2.0 - 71 6 102
ACA-LN8S M 120/180/215 8,700 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/90/B14 1.8 / 3.3 - 83 6 102
ACAF-LN8L M 120/180/215 6,150 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/90/B14 0.9 / 2.0 LPF280 71 6 110
ACAF-LN8S M 120/180/215 8,700 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/90/B14 1.8 / 3.3 LPF280 83 6 110
ACA-LN9L M 120/180/215 7,500 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/90/B14 0.9 / 2.0 - 70 11 132
ACA-LN9S M 120/180/215 10,900 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/90/B14 1.8 / 3.3 - 83 11 132
ACAF-LN9L M 120/180/215 7,500 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/90/B14 0.9 / 2.0 LPF280 70 11 140
ACAF-LN9S M 120/180/215 10,900 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/90/B14 1.8 / 3.3 LPF280 83 11 140
ACA-LN10L M 120/180/215 12,000 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/90/B14 1.3 / 2.7 - 74 14 172
ACA-LN10S M 120/180/215 16,400 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/100/B14 3.6 / 7.2 - 80 14 172
ACAF-LN10L M 120/180/215 12,000 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/90/B14 1.3 / 2.7 LPF280 74 14 180
ACAF-LN10S M 120/180/215 16,400 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/100/B14 3.6 / 7.2 LPF280 80 14 180
ACA-LN11L M 120/180/215 18,300 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/112/B14 2.6 / 4.6 - 78 18 212
ACA-LN11S M 120/180/215 23,600 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/112/B14 4.8 / 8.0 - 84 18 212
ACAF-LN11L M 120/180/215 18,300 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 6/112/B14 2.6 / 4.6 LPF280 78 18 220
ACAF-LN11S M 120/180/215 23,600 40/58/69 320/130/240 3.0 / 6.7 5.5 / 10.4 4/112/B14 4.8 / 8.0 LPF280 84 18 220
1)
Medium: F = mineral oil or water-glycol, M = mineral oil
2)
Depends on pump displacement
3)
Current requirement: B version at 400 V 50 Hz / C version at 480 V 60 Hz
4)
Fluid in cooling element
5)
Unfilled
ll Stable cooling and filtration (independent of the cycle times of the system)
ll Continuous filtration is possible, cooling as required
ll Avoidance of pressure surges in the cooling element
ll Design of the cooler is in accordance with the cooling capacity required (not according to the maximum possible return flow volume)
47
Cooling Capacity and Pressure Difference p
Mineral oil
Cooling capacity:
Dependent on the oil flow rate
280 7.0 and the temperature difference T
260 14S 6.5 between oil inlet and air inlet.
240 6.0
Note:
220
14L 5.5 The values are measured
Heat dissipation [kW] at T = 40 C
Pressure difference p
2.75
2.50 11L-S
2.25 10L-S
2.00
8L-S
14L-S
Pressure drop [bar]
1.75
12L-S
1.50
1.25 9L-S
1.00
0.75
0.50
0.25
0.00
0 60 120 180 240 300 360 420 480 540 600 660 720 780 840 900 960
Measured at 30 mm/s
Tolerance: 5 %
48
Cooling Capacity and Pressure Difference p
Water-glycol (60/40)
AC-LN
50 Hz / 60 Hz
Cooling capacity:
Dependant on the water-glycol flow
270 9.0 rate and the temperature difference T
255 8.5 between w/g inlet and air inlet.
14S
240 8.0
225 7.5 Note:
210 7.0 The values are measured
Heat dissipation [kW] at T = 30 C
Pressure difference p
900
12L-S
800
14L-S
700 10L-S
11L-S
600
Pressure drop [mbar]
8L-S
500
400
9L-S
300
200
100
0
0 60 120 180 240 300 360 420 480 540 600 660 720 780 840 900 960
Measured at 2 mm/s
Tolerance: 5 %
E 5.814.0/03.15
49
Model Type
ACAF-LN 8S-40-1.0-B-M-B-LPF280-10-1-IBT
Cooler type
AC-LN = Air cooler (oil / water-glycol mix)
ACA-LN = Air cooler (oil) with integrated pump
ACAF-LN = Air cooler (oil) with integrated pump and filter
Size/motor speed
8-14 = Size
L = 6 poles (1,000 rpm)
S = 4 poles (1,500 rpm)
Displacement cm3/rev
40/58/69 (only ACA-LN/ACAF-LN 8-11)
Revision
Clogging indicators (only ACAF-LN)
A = Without clogging indicator
B = With visual indicator (Standard)
D = With electrical and optical indicator (24 V)
Fluids
F = Mineral oil or water glycol mix (AC-LN)
M = Mineral oil (ACA-LN and ACAF-LN)
Motor voltage
Standard voltages and frequencies for 3 phase motor
B = 230/400 V 50 Hz
C = 265/460 V 60 Hz
A = Special version 230/400 V 50 Hz / 265/460 V 60 Hz
(tolerance voltage 10 %)
Other voltages on request
Size of filter (only ACAF-LN)
ACAF-LN8-11 = LPF280
Filtration rating in micron (only ACAF-LN)
5 = 5 m Betamicron-4-N (5 BN4HC)
10 = 10 m Betamicron-4-N (10 BN4HC) (standard)
20 = 20 m Betamicron-4-N (20 BN4HC)
Color
1 = RAL 9002 (standard)
Other colors on request.
Accessories
IBP = Heat exchanger with integrated bypass valve
IBT = Heat exchanger with integrated thermo-bypass valve
AITF = Thermostat (fixed)
For all possible accessories, like vibration absorber, air filter grid or air filter mat
please refer to brochure Accessories for air coolers.
E 5.814.0/ 03.15
50
Dimensions
AC-LN 8-9-10-11
A/2 A/2
B
Z1 (3x)
E1
Air
A
Z3
(4x) E3 PLUG D2
E2
Slots F
D1 C
D3
AC-LN 12-14
A/4 A/4
E1 B
PLUG
Air
Z3 (4x)
Z1 (2x)
A
E2
Air
PLUG D2 D1
C D3
A B C D1 D2 D3 E1 E2 E3 F Z1 Z3
10 25 10 2 2 2 5 5 5 Slots
AC-LN8 L 725 596 705 410 560 450 627 58 74 9x20 G1 M22x1.5
AC-LN8 S 725 626 705 410 560 450 627 58 74 9x20 G1 M22x1.5
AC-LN9 L 880 750 790 750 700 790 757 76.5 148 12 G1 M22x1.5
AC-LN9 S 880 780 790 750 700 790 757 76.5 148 12 G1 M22x1.5
AC-LN10 L 1,030 766 930 750 700 790 907 76.5 147 12 G1 M22x1.5
AC-LN10 S 1,030 787 930 750 700 790 907 76.5 147 12 G1 M22x1.5
AC-LN11 L 1,180 811 1,050 750 700 790 1,057 76.5 147 12 G1 M22x1.5
AC-LN11 S 1,180 810 1,050 750 700 790 1,057 76.5 147 12 G1 M22x1.5
AC-LN12 L 2,130 718 1,000 750 760 870 907 1,075 - 13x30 SAE2 M22x1.5
E 5.814.0/03.15
AC-LN12 S 2,130 738 1,000 750 760 870 907 1,075 - 13x30 SAE2 M22x1.5
AC-LN14 L 2,297 763 1,140 750 900 870 1,057 1,166 - 13x30 SAE2 M22x1.5
AC-LN14 S 2,297 761 1,140 750 900 870 1,057 1,166 - 13x30 SAE2 M22x1.5
51
Dimensions
ACA-LN 8-9-10-11
A/2 A/2
B
C1
Z2 (OUT)
E1
Air
A
Z3
Z1 (IN)
E2
E3 PLUG D2
(6x)
Slots F D4 C
D1
D3
ACAF-LN 8-9-10-11
A/2 A/2
B
C1
Z2 (OUT)
E1
Air
A
Z3
Z1 (IN)
E2
(6x) PLUG
E3 D2
Slots F
D4 C
D1
D3
A B C C1 D1 D2 D3 D4 E1 E2 E3 F Z1 Z2 Z3
10 25 10 25 2 2 2 2 5 5 5 Slots (IN) (3x)
ACA-LN8L 760 596 705 837 830 560 870 560 627 94 74 9x20 G2 G1 1/4 M22x1.5
ACA-LN8S 760 626 705 837 830 560 870 560 627 94 74 9x20 G2 G1 1/4 M22x1.5
ACA-LN9L 905 730 790 914 830 700 870 560 757 102 128 9x20 G2 G1 1/2 M22x1.5
ACA-LN9S 905 760 790 914 830 700 870 560 757 102 128 9x20 G2 G1 1/2 M22x1.5
ACA-LN10L 1,055 746 930 1,053 830 700 870 560 907 102 127 9x20 G2 G1 1/2 M22x1.5
ACA-LN10S 1,055 767 930 1,053 830 700 870 560 907 102 127 9x20 G2 G1 1/2 M22x1.5
ACA-LN11L 1,205 791 1,050 1,164 830 700 870 560 1,057 102 127 9x20 G2 G1 1/2 M22x1.5
ACA-LN11S 1,205 790 1,050 1,164 830 700 870 560 1,057 102 127 9x20 G2 G1 1/2 M22x1.5
ACAF-LN8L 760 596 705 846 830 560 870 560 627 94 74 9x20 G2 G1 1/4 M22x1.5
ACAF-LN8S 760 626 705 846 830 560 870 560 627 94 74 9x20 G2 G1 1/4 M22x1.5
ACAF-LN9L 905 730 790 929 830 700 870 560 757 102 128 9x20 G2 G1 1/2 M22x1.5
ACAF-LN9S 905 760 790 929 830 700 870 560 757 102 128 9x20 G2 G1 1/2 M22x1.5
ACAF-LN10L 1,055 746 930 1068 830 700 870 560 907 102 127 9x20 G2 G1 1/2 M22x1.5
E 5.814.0/ 03.15
ACAF-LN10S 1,055 767 930 1,068 830 700 780 560 907 102 127 9x20 G2 G1 1/2 M22x1.5
ACAF-LN11L 1,205 791 1,050 1,193 830 700 870 560 1,057 102 127 9x20 G2 G1 1/2 M22x1.5
ACAF-LN11S 1,205 790 1,050 1,193 830 700 870 560 1,057 102 127 9x20 G2 G1 1/2 M22x1.5
52
Note:
We recommend maintaining a minimum
distance to ensure an unimpeded air
inlet and air outlet. For sizes 8 -11 this
is half the height of the cooling element
(A/2); for sizes 12 -14 it is a quarter
of the element height (A/4). Anything
below the minimum distance can
influence the cooling capacity and the
noise emissions.
E 5.814.0/03.15
53
Note
The information in this brochure
relates to the operating conditions
and applications described.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications.
54
Air Cooler Industry
AC-LN 8-14 MI
with integrated frequency inverter
55
Product Features Design
AC-LN MI coolers use high efficiency AC-LN 8-9-10-11 MI
axial fans driven by a frequency inverter.
This guarantees immediate adjustment
to required cooling performance under
changing load conditions.
ll Variable speed
The inverter controls the fan speed in
order to have a constant temperature.
ll Plug and Play
Simple installation thanks to the
integrated frequency inverter and
temperature probe.
ll Lower operating cost
The electric power is required only
when cooling power is needed 1 Motor with integrated inverter
allowing lower power consumption. 2 Axial fan
ll Lower average noise level 3 Fan housing
When less power is required the
4 Heat exchanger
cooler generates less noise.
ll PT1000 Temperature probe
with probe holder
Accurate and reliable temperature
4
measurement, no need to drain
the cooling system when probe 3
replacement is needed.
ll Fail-Safe operation
Operation at maximum speed 1 2
in case of Probe failure detection
(open or short circuit).
ll Own safety
If during operation the electronic
overheats, fan speed drops
AC-LN 12-14 MI
automatically.
ll Software interface
A user friendly interface is available
to check and modify all the
parameters directly on site
(see also Technical Data).
Options
Integrated pressure bypass valve
(IBP) / Integrated thermal pressure
bypass valve (IBT)
The bypass channel is integrated in the
cooling element. If a particular pressure
is exceeded, the IBP opens the bypass
channel, thereby protecting the cooling
element from too high a pressure.
Furthermore, the IBT only opens the
cooling element path once a particular
temperature has been reached.
1
E 5.817.0/ 03.15
56
Technical Data
AC-LN MI
Weight [kg] 5)
Volumen [l] 5)
Fan motor 3):
Fluid [-] 1)
P/N
Temperature control
The fan frequency will be controlled
by the measured fluid temperature
according to the following diagram. fmax
Frequency [Hz]
Note
The inverter parameters are set
according to the customer requirements
before cooler dispatch. For on site
parameters modification a free software fmin
interface is available at the HYDAC
homepage www.hydac.com.
The needed programming cable
has to be ordered separately
Toff Tmin Tmax
(HYDAC P/N: 3880225).
Fluid temp. [C]
Tmax Temperature at which the inverter turns the fan to max. speed [C]
57
PT1000 Temperature Probe
The platinum resistance PT1000 temperature probe offers reliable and accurate
temperature measurement. At the AC-LN MI the probe is installed directly in the
cooling element with a probe holder.
58
Cooling Capacity and Pressure Difference p
Mineral oil
AC-LN MI
Cooling capacity:
Dependent on the oil flow rate and the
temperature difference T between oil
280 7.0 inlet and air inlet.
260 6.5
14MI Note:
240 6.0
The values are measured at
Heat dissipation [kW] at T = 40 C
Pressure difference p
2.75
2.50
11MI
2.25 10MI
2.00
8MI
14MI
Pressure drop [bar]
1.75
12MI
1.50
1.25 9MI
1.00
0.75
0.50
0.25
0.00
0 60 120 180 240 300 360 420 480 540 600 660 720 780 840
900 960
Measured at 30 mm/s
Tolerance: 5 %
59
Cooling Capacity and Pressure Difference p
Water-glycol (60/40)
AC-LN MI
Cooling capacity:
Dependant on the water-glycol flow
rate and the temperature difference T
270 9.0
between w/g inlet and air inlet.
240 8.0
Note:
Heat dissipation [kW] at T = 30 C
14MI
Pressure difference p
900
12MI
800
14MI
700 10MI
11MI
600
Pressure drop [mbar]
8MI
500
400
9MI
300
200
100
0
0 60 120 180 240 300 360 420 480 540 600 660 720 780 840 900 960
Measured at 2 mm/s
Tolerance: 5 %
E 5.817.0/ 03.15
60
Model Type
AC-LN 8MI-1.0-F-A-1-IBT
Cooler type
AC-LN = Air cooler (mineral oil or water glycol mix)
Size Motor speed min. / max.
8MI = 400 / 1,800 min-1
9MI = 400 / 1,800 min-1
10MI = 400 / 1,500 min-1
11MI = 600 / 1,200 min-1
12MI = 400 / 1,500 min-1
14MI = 600 / 1,200 min-1
Revision
Fluids
F = Mineral oil or water glycol mix
Motor voltage
Supply
voltage = 350 520 V
Color
1 = RAL 9002 (standard)
Other colors on request.
Accessories
IBP = Heat exchanger with integrated bypass valve
IBT = Heat exchanger with integrated thermo-bypass valve
For all possible accessories, like vibration absorber, air filter grid or
air filter mat please refer to brochure Accessories for air coolers
E 5.817.0/03.15
61
Dimensions
AC-LN 8-9-10-11 MI
A/2 A/2
B
Z1 (3x)
E1
Air
A
Z3
E2
(4x) F E3 PLUG D2
D1 C
D3
AC-LN 12-14 MI
A/4 A/4
E1 PLUG B
Z3 (4x)
Z1 (2x)
A
E2
PLUG D2 (4x) F D1
C D3
A B C D1 D2 D3 E1 E2 E3 F Z1 Z3
[mm]
10 25 10 2 2 2 5 5 5 Loch
AC-LN8 MI 725 659 705 410 560 450 627 58.0 74 9x20 G 1-1/4" M22x1,5
AC-LN9 MI 880 813 790 750 700 790 757 76.5 148 12 G 1-1/2" M22x1,5
AC-LN10 MI 1,030 799 930 750 700 790 907 76.5 147 12 G 1-1/2" M22x1,5
E 5.817.0/ 03.15
AC-LN11 MI 1,180 813 1,050 750 700 790 1,057 76.5 147 12 G 1-1/2" M22x1,5
AC-LN12 MI 2,130 751 1,000 750 760 870 907 1,075.0 - 13x30 SAE 2" M22x1,5
AC-LN14 MI 2,297 764 1,140 750 900 870 1,057 1,166.0 - 13x30 SAE 2" M22x1,5
62
Note:
We recommend maintaining a minimum
distance to ensure an unimpeded air
inlet and air outlet. For sizes 8-11 this
is half the height of the cooling element
(A/2); for sizes 12-14 it is a quarter
of the element height (A/4). Anything
below the minimum distance can
influence the cooling capacity and the
noise emissions.
E 5.817.0/03.15
63
Note
The information in this brochure
relates to the operating conditions
and applications described.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications.
64
Air Cooler Industry
OSCA / OSCAF 0-3
Product Features
Installed off-line, the OSCAF provides
efficient cooling and filtration of the
hydraulic fluid regardless of the duty
cycle of the hydraulic system. And,
the cooler can be sized perfectly to
the necessary cooling performance,
rather than to the maximum return-line
flow rate. Off-line installation will also
eliminate flow variances of the hydraulic
fluid and resulting pressure spikes which
potentially could lead to a premature
cooler failure.
E 5.811.3/03.15
65
ll Stable cooling and filtration Design
(independent of the cycle times of the
system) OSCA 0
ll Avoidance of pressure surges in the
cooling element
ll Design of the cooler is in accordance
with the cooling capacity required (not
according to the maximum possible
return flow volume)
Low noise
ll Utilizes compact low noise screw
pump
Compact
ll Small in size and low in weight
1 Motor
ll Easy to attach external exhaust ducts
2 Screw pump
3 Radial fan
4 Fan housing 5
5 Heat exchanger
3
2
1
OSCA 1-3
Compact: filter integrated in heat exchanger
Efficient
ll Integration of several features in one
unit: pumping, cooling, filtration
ll No additional piping; fewer potential
leak points
ll Integrated filter with inside-outside
filter technology;
magnetic particle trap and standard
2.5 bar pressure bypass included
ll Low and easy maintenance (only
one plug to remove for filter element
change) 1 Motor
2 Screw pump
Application Field 3 Fan housing
Systems with small and medium 4 Radial fan
hydraulic systems, such as: 5 Heat exchanger
ll Lubrication systems
1
ll Machine tools
ll Hydraulic presses 2
ll Hydraulic systems
ll Hydraulic lifts
4 3
E 5.811.3/ 03.15
66
Design
OSCAF 0
1 Motor
5 2 Screw pump
3 Radial fan
4 4 Fan housing
3
5 Heat exchanger
6 External filter
2
1
6
OSCAF 1- 3
1 Motor
2 Screw pump
3 Radial fan
4 Fan housing 1
5 Heat exchanger
6 Integrated filter
2
3
5
E 5.811.3/03.15
67
Technical Data
OSCA/ OSCAF
Displacement [cm3/U]
at 50 / 60 Hz [dB (A)]
Motor: Power [kW] 2)
@ 400 V 50 Hz
Air flow [m3/h]
at 30 mm2/s 1)
Weight [kg] 4)
Volume [l] 3)
P/N
OSCA 0L 3926218 1.5 0.11 10 10 155 6/71 0.25 1.0 56/60 - 0.5 20
OSCA 0S 3926219 1.8 0.19 10 15 300 4/71 0.37 1.2 63/67 - 0.5 20
OSCAF 0L 3926223 1.5 0.11 10 10 155 6/71 0.25 1.0 56/60 LF60 0.5 25
OSCAF 0S 3926222 1.8 0.19 10 15 300 4/71 0.37 1.2 63/67 LF60 0.5 25
OSCA 1L 3768893 3.7 0.08 10 10 600 4/71 0.25 1.0 59/63 - 0.9 28
OSCA 1S 3684999 4.3 0.12 10 15 870 4/71 0.37 1.2 66/70 - 0.9 28
OSCAF 1L 3769020 3.7 0.13 10 10 600 6/71 0.25 1.0 59/63 NG080 1.6 31
OSCAF 1S 3708807 4.3 0.18 10 15 870 4/71 0.37 1.2 66/70 NG080 1.6 31
OSCA 2L 3647770 7.0 0.30 28 28 1,200 6/90 0.75 2.0 60/64 - 1.4 40
OSCA 2S 3647749 9.2 0.45 28 40 1,750 4/90 1.10 2.5 69/73 - 1.4 40
OSCAF 2L 3647771 7.0 0.50 28 28 1,200 6/90 0.75 2.0 60/64 NG080 2.4 43
OSCAF 2S 3647750 9.2 0.85 28 40 1,750 4/90 1.10 2.5 69/73 NG080 2.4 43
OSCA 3L 3764555 11.6 0.25 28 28 2,350 6/90 1.10 2.7 67/71 - 2.0 63
OSCA 3S 3672255 15.0 0.38 28 40 3,400 4/90 1.80 3.7 77/81 - 2.0 63
OSCAF 3L 3764557 11.6 0.44 28 28 2,350 6/90 1.10 2.7 67/71 NG080 3.3 66
OSCAF 3S 3675061 15.0 0.75 28 40 3,400 4/90 1.80 3.7 77/81 NG080 3.3 66
1)
At 50 Hz
2)
IE2 (only for 0,75 kW)
3)
Fluid in cooling element
4)
Unfilled
For other viscosities, the pressure loss must be multiplied by the conversion factor K:
Viscosity (mm/s) 10 15 22 32 46 68 100 150
Factor K 0.35 0.5 0.75 1 1.4 1.9 2.5 2.3
E 5.811.3/ 03.15
68
Model Type
OSCAF-2L-28-5.0-B-M-A-NG080-10-1-GP
Cooler type
OSCA = Air cooler with integrated pump
OSCAF = Air cooler with integrated pump and filter
Baugre/Motordrehzahl
0 -3 = Size
L = 6 pl (1,000 rpm)
S = 4 pl (1,500 rpm)
Displacement cm3/rev
10 = Screw pump (OSCA / OSCAF 0-1)
28 = Screw pump (OSCA / OSCAF 2-3)
Revision
Clogging indicators (only OSCAF)
A = Without clogging indicator
B = With visual indicator (Standard)
D = With electrical and optical indicator
Fluids
M = Mineral Oil
Motor voltage
Standard voltages and frequencies for 3 phase motor
A = 230/400 V 50 Hz / 265/460 V 60 Hz
(Tolerance voltage 10 %)
Other voltages on request.
Size of filter (only OSCAF)
LF60 = OSCAF 0
NG080 = OSCAF 1-2-3
Filtration rating in micron (only OSCAF)
OSCAF 0
5 = 5 m Betamicron-4-N (5 BN4HC)
10 = 10 m Betamicron-4-N (10 BN4HC) (Standard)
20 = 20 m Betamicron-4-N (20 BN4HC)
OSCAF 1-2-3
5 = 5 m SHC (K-10174 NG080-5)
10 = 10 m SHC (K-10174 NG080-10) (Standard)
20 = 20 m SHC (K-10174 NG080-20)
Color
1 = RAL 9002 (Standard)
Other colors on request.
Accessories
e.g. vibration absorber
E 5.811.3/03.15
69
Dimensions
OSCA 0
E1 E2 A/2
3A
Air
Z2 (OUT)
Z1 (IN)
A
E3
Air
D2 D1
C1 D4
D3
B
OSCA 1- 3
A/2
3A
Air
Z2 (OUT)
Z1 (IN)
E1
Air
A
C
F (Slots) PLUG
E2
E3 D2
D1 C1
D3
A B C1 D1 D2 D3 D4 E1 E2 E3 F Z1 Z2
10 10 10 2 2 2 2 2 2 2 Slot (IN) (OUT)
OSCA 0 372 495 335 205 285 275 255 269 33 341 9 G1" G3/4"
E 5.811.3/ 03.15
OSCA 1 360 674 370 420 290 481 - 195 91 54.5 9 G1" G3/4"
OSCA 2 433 766 449 455 373 521 - 288 83 37.5 9 G1" G3/4"
OSCA 3 542 841 555 520 450 584 - 404 79 59 9 G1" G3/4"
70
OSCAF 0
E1 E2 A/2
3A
Z2 (OUT)
Air
Z1 (IN)
A1
A
E3
Air
D2 D1
C1 D4
C2 D3
B
OSCAF 1- 3
3A
A/2
Air
Z2 (OUT)
Z1 (IN)
Air
A1
E1
F (Slots) PLUG
E2
E3 D2
D1 C1
D3 C2
A A1 B C1 C2 D1 D2 D3 D4 E1 E2 E3 F Z1 Z2
10 10 10 10 10 2 2 2 2 2 2 2 Slot (IN) (OUT)
OSCAF 0 372 381 495 335 345 205 285 275 255 269 33 341 9 G1" G3/4"
E 5.811.3/03.15
OSCAF 1 375 355 674 370 463 420 290 481 - 195 91 54.5 9 G1" G3/4"
OSCAF 2 453 433 766 449 540 455 373 521 - 288 83 37.5 9 G1" G3/4"
OSCAF 3 560 540 841 555 647 520 450 584 - 404 79 59 9 G1" G3/4"
71
Note: Note
We recommend maintaining a minimum
The information in this brochure
distance to ensure an unimpeded air
relates to the operating conditions
inlet and air outlet. This is half the
and applications described.
height of the cooling element (A/2).
Anything below the minimum distance For applications and operating conditions
can influence the cooling capacity and not described, please contact the
the noise emissions. relevant technical department.
Subject to technical modifications.
72
Air Cooler Industry
OK-ELC 0-7
Application Field
Systems with small and medium cooling
requirements, such as
ll Industrial power units
E 5.806.2/03.15
ll Lubrication systems
ll Machine tools
73
Options Design
Integrated pressure bypass OK-ELC 0
valve (IBP) / Integrated thermal
pressure bypass valve (IBT)
The bypass channel is integrated in the
cooling element. If a particular pressure
is exceeded, the IBP opens the bypass
channel, thereby protecting the cooling
element from too high a pressure.
Furthermore, the IBT only opens the
cooling element path once a particular
temperature has been reached.
2 PASS
OK-ELC 1
2 Fan housing
3 Heat exchanger 2
1
E 5.806.2/ 03.15
74
Design
OK-ELC 2-5
OK-ELC 6-7
1
E 5.806.2/03.15
75
Technical Data
OK-ELC 0-7
Fan motor:
Air flow [m3/h]
[kW / A]2)
Type of cooler
Weight [kg] 4)
Volume [l] 3)
N of poles
Voltage [V]
[dB(A)]
P/N
kW A
OK-ELC 1H 3117022 230 150 900 2 0.12 0.54 2/450 230 71 0.5 9.0
OK-ELC 1H 3117021 400 150 900 2 0.12 0.34 2/500 230 71 0.5 9.0
OK-ELC 2H 3110965 230 180 850 2 0.15 0.50 2/450 250 71 2.0 11.9
OK-ELC 2H 3099620 400 180 850 2 0.17 0.37 2/500 250 71 2.0 11.9
OK-ELC 3H 3108660 230 180 1,300 2 0.17 0.75 4/450 300 75 2.2 14.7
OK-ELC 3H 3100673 400 180 1,300 2 0.19 0.56 3/500 300 75 2.2 14.7
OK-ELC 4S 3979356 230 250 1,900 4 0.21 0.92 4/450 400 69 3.0 21.0
OK-ELC 4S 3979358 400 250 1,900 4 0.23 0.40 400 69 3.0 21.0
OK-ELC 5S 3979359 230 250 2,000 4 0.21 0.92 4/450 400 72 5.2 28.0
OK-ELC 5S 3979360 400 250 2,000 4 0.23 0.40 400 72 5.2 28.0
OK-ELC 6H 3115191 230 250 3,000 2 0.17 0.75 4/450 300 75 4.2 39.0
OK-ELC 6H 3106810 400 250 3,000 2 0.19 0.56 3/500 300 75 4.2 39.0
OK-ELC 7S 3115193 230 250 4,200 4 0.21 0.92 4/450 400 71 5.2 45.0
OK-ELC 7S 3106811 400 250 4,200 4 0.23 0.40 400 71 5.2 45.0
1)
Max. flow rate
2)
OK-ELC 6-7: each fan
3)
Fluid in cooling element
4)
Unfilled
E 5.806.2/ 03.15
76
Cooling Capacity and Pressure Difference p
OK-ELC 0-7
Cooling capacity:
Dependent on the oil flow rate and
32 0.8 the temperature difference T between
oil inlet and air inlet.
28 OK-ELC 7S 0.7
Note:
The values are measured at
Heat dissipation at T = 40 C [kW]
24 0.6
OK-ELC 4S
12 0.3
OK-ELC 3H
8 0.2
OK-ELC 2H
OK-ELC 1H
4 0.1
OK-ELC 0H
0 0.0
0 50 100 150 200 250
Pressure difference p
2.2
OK-ELC 6
OK-ELC 1
2.0
Pressure drop at 30 mm2/s [bar]
1.8
OK-ELC 4
1.6
1.4 OK-ELC 5
OK-ELC 2
1.2 OK-ELC 3
1.0
0.8
0.6
0.4
0.2
0.0
0 50 100 150 200 250
measured at 30 mm/s
Tolerance: 5 %
77
Model Type
OK-ELC-1H-1.0-230 V-1-S-AITF50
Cooler type
OK-ELC = Oil-Air cooler
Size / motor speed
0-7 = size (see cooling capacity)
H = 3,000 min-1
S = 1,500 min-1
Revision
Motor voltage
230 V = 230 V 50 Hz, 220 V 60 Hz
400 V = 400 V 50 Hz, 440 V 60 Hz
Color
1 = RAL 9005 (standard)
Other colors on request.
Air flow direction
S = Suction (standard)
Accessories
IBP = Heat exchanger with integrated bypass valve (not available for OK-ELC 0 and OK-ELC 1)
IBT = Heat exchanger with integrated thermo-bypass valve (not available for OK-ELC 0 and OK-ELC 1)
AITF = Thermostat (fixed)
For all possible accessories, like vibration absorber, air filter grid or air filter mat,
please refer to brochure Accessories for air coolers.
E 5.806.2/ 03.15
78
Dimensions
OK-ELC 0
A/2 A/2
Z
ROTATION
1 (2
AIR x)
Airflow
Rotation
E1
A
AIR E2
(4x) F D1 D2
D3 C2
B
C1
A B C1 C2 D1 D2 D3 E1 E2 F Z1
[mm]
5 10 5 5 2 2 2 5 5 /slot
OK ELC 0 200 135 240 220 60 190 80 72 79 6.5 G
Dimensions
OK-ELC 1
A/2 A/2
Z3
Z1 ROTATION
(2x
)
Z
1 (2
AIR
x)
E1
AIR
E2
D2 D4
E3 (6x) F D1
C D3
B
E 5.806.2/03.15
A B C D1 D2 D3 D4 E1 E2 E3 F Z1 Z3
[mm]
5 10 5 2 2 2 2 5 5 5 /slot
OK-ELC 1 298 197 340 110 270 136 50 200 65 300 8.5 G M22x1.5
79
Dimensions
OK-ELC 2-5
ROTATION
A/2 A/2
E5 E5
Z3 B
Z1
(2
x)
HYDAC
AIR
E1
E4
A
AIR
E2
D2
E3 (4x) F D1
C D3
A B C D1 D2 D3 E1 E2 E3 E4 E5 F Z1 Z3
[mm]
5 10 5 2 2 2 5 5 5 5 2 /slot
OK-ELC 2 328 290 384 255 160 295 199 72 324 288 80 9 G1 M22x1.5
OK-ELC 3 371 287 420 255 240 295 233 76 370 329 100 14x10 G1 M22x1.5
1)
OK-ELC 4 465 292 500 255 255 295 300 90 445 421 150 19x10 G1 M22x1.5
1)
OK-ELC 5 475 306 600 255 255 295 350 72 490 200 2)
580 2)
12 G1- M22x1.51)
1)
OK-ELC 3, OK-ELC 4 and OK-ELC 5 have two connections M22x1.5
2)
OK-ELC 5 has the front fixing holes in the lateral sides
E 5.806.2/ 03.15
80
Dimensions
OK-ELC 6-7
AIR
E1
E4
A
AIR
E2
D2 D1
E3 (4x) F D3
A B C D1 D2 D3 E1 E2 E3 E4 E5 F Z1 Z3
[mm]
5 10 5 2 2 2 5 5 5 5 2 /slot
OK-ELC 6 495 289 810 255 482 295 321 95 750 445 170 10x20 G1- M22x1.5
OK-ELC 7 547 289 950 255 482 295 373 96 888 503 200 9x21 G1- M22x1.5
Note:
We recommend maintaining a minimum
distance to ensure an unimpeded air
inlet and air outlet. This is half the
E 5.806.2/03.15
82
Air Cooler Industry
AC-MS
Modular Systems
General Design
The new AC-MS air coolers are Depending on the specific needs of the application it is possible to choose the coolers
specifically designed to meet the needs among these three configurations:
of electric power generation applications,
such as Diesel or gas generators,
gas turbines, cogeneration units, gas
compressors and general applications in Low Noise Coolers
oil and gas industry. ll Fixed fan speed rotation
ll Variable speed fan
ll Ultra-silent coolers for
Product Features special applications
Due to the high level of efficiency
achieved by our aluminium cooling
elements made with plate & bar
technology, the new AC-MS coolers
are designed to allow the installation
inside the standard and high cube
ISO 20-40 ft container, for Diesel / gas
engines, gas turbines and compressors
Compact Design
with the highest power output.
ll High performance
The modular design of the coolers in a compact design
makes possible the integration in several ll Side by side coolers
types of installations, and offers the ll Stacked coolers
possibility to expand the cooling capacity
of new and existing power plants.
The AC-MS coolers may be used
for cooling the following fluids:
ll Engine cooling circuits
HT High temperature circuit
for jacket water
ll LT Low temperature circuit for Heavy Duty Systems
air to water charge cooler ll Enhanced performance
ll Charge air for Diesel and ll Extreme ambient conditions
Gas turbo after-cooled engines
ll Lubricating and transmission
oil circuits
ll Diesel fuel
Application Field
ll Diesel and gas generators with a AC-MS Benefits
power output up to 3,000 kVA and over
ll Modularity: ll Efficiency:
ll Gas turbines
Expand your cooling capacity Low noise coolers reduce energy
ll Gas compressors
without limitation. consumption further by use of low
ll Combined heat and power
ll Compactness: speed fans.
applications (CHP)
Design is optimized for ll Low cost of maintenance due to
E 5.820.0/03.15
electrical power output of 40 kVA / 200 kVA / 300 kVA / 500 kVA / 800 kVA and
up to 1,400 kVA.
Modularity of the cooling systems allows to expand the cooling capacity to any
enhanced requirement.
84
AC-MS Compact Design
AC-MS compact coolers are the ideal choice for energy power applications that demand extremely high thermal capacity
in limited space.
The overall dimensions of the coolers are compatible with the height limits of standard or high cube 20/40 ft ISO container.
With electric motors for fan drives with electric power up to 22 kW with 2 and 4 poles and option for variable speed drive.
The modular design allows vertical and horizontal air flow direction. Mounting position of the cooling system in both vertical
and horizontal position meets any specific installation requirement.
E 5.820.0/03.15
85
AC-MS Heavy Duty
AC-MS Heavy Duty systems are designed to match the highest level of performances and reliability.
The radiator core is available with various core thicknesses, assembled in a structural steel frame suitable for outdoor installation.
Those coolers integrate a bunded tank required for leakage and for safe maintenance operation.
AC-MS coolers are available in several standard models that may be configured with options such as acoustic louvers,
hydraulic and electrical control box, air flow inlet and outlet conveyor.
All the parts are easily accessible for cleaning, inspections and testing procedures.
Typical applications are those in the energy market segment as well as for gas turbine lubrication oil bearing or
general industrial application.
86
AC-MS Installation Examples
AC-MS Compact HT/LT Circuit AC-MS Compact Modular table coolers
3,200 kVA Diesel engine Cooling systems for gas compressor power station
Emergency operation Baseload and standby units
E 5.820.0/03.15
87
AC-MS Options Available Note
ll Expansion / Filling tank The information in this brochure
ll ISO flanged / Victaulic hydraulic relates to the operating conditions.
connection For applications and operating conditions
ll Fluid temperature and level sensors not described, please contact the
ll Safety switches for electric motors relevant technical department.
maintenance Subject to technical modifications.
ll CPL version
(Corrosion Protection Level)
ll ATEX version
ll Customized solutions
ll Fan systems for engine room
temperature control with AC/DC
motors and brushless option
with PWM speed control
88
Air Cooler Industry / Mobile
AC-LN / AC-LNH ATEX Version
Certified to ATEX EU Directives
Oxy
ge
e
n
c
tan
le subs
mab
E 5.819.0/03.15
am
ce
Fl
ur
o
ns
I g n it i o
89
Certification Note
The information in this brochure
II 2G EX de IIC T4 relates to the operating conditions.
II 2GD EX de IIC T4 For applications and operating conditions
not described, please contact the
relevant technical department.
II Device group:
Subject to technical modifications.
I = Mining
II = all other explosive areas (non-mining)
2G / 2GD Category:
2 = present in normal operation
Explosive atmosphere:
G = gas
D = dust
Ex Explosion protection
de Type of protection:
de = fireproof with increased safety
T4 Temperature classes:
T4 = 135 C
90
Air Cooler Industry
AC-LN / ACA-LN / ACAF-LN 2-14
Corrosion Protection Levels (CPL)
Application Field
For all industrial applications, indoor and outdoor applications in an
aggressive environment where a high level of corrosion protection is requested.
e.g.
ll cranes
ll harbour
ll marine platforms
ll ships
ll chemical plants
ll agricultural sites
E 5.821.0/ 03.15
91
Model Type
AC-LN10L--CPL2
Corrosion Protection Level
n/a = Standard
CPL1 = Medium protection level
CPL2 = High protection level
CPLS = Special protection level
For CPLS version refer to the technical department.
Note
The information in this brochure
relates to the operating conditions.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications.
92
Air Cooler Mobile
OK-ELH 2-7
with hydraulic motor
93
Options
Integrated pressure bypass Dimension
valve (IBP) / Integrated thermal
pressure bypass valve (IBT)
The bypass channel is integrated in the
cooling element. If a particular pressure
is exceeded, the IBP opens the bypass
channel, thereby protecting the cooling 4
element from too high a pressure. L
Furthermore, the IBT only opens the G 1/4
cooling element path once a particular
46
30
temperature has been reached.
ATEX
36
The OK-ELH is also available for
100
T P
TP
operation in gas and dust explosive
areas. P (T)
94
Design
OK-ELH 2-4
E 5.808.1/ 03.15
95
Design
OK-ELH 5 OK-ELH 6 OK-ELH 7
OK-ELH 5
5
1
E 5.808.1/03.15
96
Technical Data
OK-ELH 2-7
Required pressure
(at 1 m distance)
Air flow [m/h] 1)
Type of cooler
Weight [kg]4)
Volume [l]3)
P/N
OK-ELH 2 3118399 6.3 1,500 - 3,000 180 420 250 20 10.5 69 2.0 11
OK-ELH 2 3118400 14.0 1,500 - 3,000 180 420 250 20 23.0 69 2.0 11
OK-ELH 3 3103131 6.3 1,500 - 3,000 250 740 250 20 10.5 69 2.2 13
OK-ELH 3 3103134 14.0 1,500 - 3,000 250 740 250 20 23.0 69 2.2 13
OK-ELH 3 3103523 22.0 1,500 - 3,000 250 740 150 20 36.6 69 2.2 13
OK-ELH 4 3106813 6.3 1,500 - 3,000 250 1,500 250 50 10.5 70 3.0 18
OK-ELH 4 3106816 14.0 1,500 - 3,000 250 1,500 250 30 23.0 70 3.0 18
OK-ELH 4 3106817 22.0 1,500 - 3,000 250 1,500 150 20 36.6 70 3.0 18
OK-ELH 5 3098892 6.3 1,500 - 3,000 250 1,700 250 70 10.5 70 5.2 24
OK-ELH 5 3103135 14.0 1,500 - 3,000 250 1,700 250 30 23.0 70 5.2 24
OK-ELH 5 3107149 22.0 1,500 - 3,000 250 1,700 150 20 36.6 70 5.2 24
OK-ELH 6 3128565 6.3 1,000 - 3,000 250 3,300 250 150 10.5 72 4.6 43
OK-ELH 6 3128566 14.0 1,000 - 3,000 250 3,300 250 70 23.0 72 4.6 43
OK-ELH 6 3128567 22.0 1,000 - 3,000 250 3,300 150 50 36.6 72 4.6 43
OK-ELH 7 3189345 14.0 1,000 - 2,000 250 7,800 250 220 23.0 77 5.2 50
OK-ELH 7 3189359 22.0 1,000 - 2,000 250 7,800 150 140 36.6 77 5.2 50
1)
Max. flow rate at 1,500 1/min
2)
at 34 mm/s
4)
Fluid in cooling element
3)
Unfilled
E 5.808.1/ 03.15
97
Cooling Capacity and Pressure Difference p
OK-ELH 2-7
Cooling capacity:
Dependent on the oil flow rate and
60 1.5 the temperature difference T between
OK-ELH 7 2,000 rpm oil inlet and air inlet.
56 1.4
52 1.3 Note:
The values are measured at
48 1.2 T = 40 C. For smaller T values,
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320
Pressure difference p
2.4
OK-ELH 4
2.2
OK-ELH 3
2.0
OK-ELH 6
1.8
1.6
OK-ELH 2 OK-ELH 7
Pressure drop [bar]
1.4 OK-ELH 5
1.2
1.0
0.8
0.6
0.4
0.2
0.0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320
measured at 30 mm/s
Tolerance: 5 %
98
Model Type
OK-ELH-2-1.0-H6.3TB -1-S-AITF60
Cooler type
OK-ELH = Oil-Air cooler
Size
2-7 = Baugre
Revision
Motor voltage
H6.3 = 6.3 cm3/r
H14 = 14 cm3/r
H22 = 22 cm3/r
H..TB = hydraulic motor with thermal bypass
Color
1 = RAL 9005 (standard)
Other colors on request.
Air flow direction
S = Suction (standard)
D = Blowing (on request)
Accessories
IBP = Heat exchanger with integrated bypass valve
IBT = Heat exchanger with integrated thermo-bypass valve
AITF = Thermostat (fixed)
FU = Feet
For all possible accessories, like vibration absorber, air filter grid or air filter mat
please refer to brochure Accessories for air coolers.
E 5.808.1/ 03.15
99
Dimensions
OK-ELH 2-4
ROTATION
HYDAC
HYDAC
AIR
Drain port
M12x1.5
15 depth13
E4
E1
A
35
A
AIR
E2
(4 ept
B
x) h1
E3 Z1 (2x)
M 3
6
C A (1:2.5)
A B B B C E1 E2 E3 E4 E5 F Z1 Z3
[mm] 5 10 10 10 5 5 5 5 2 2 /slot
6.3 cc 14 cc 22 cc
OK-ELH 2 313 270 283 283 384 199 57 324 288 80 14x10 G1" M22x1.5
OK-ELH 3 356 279 292 292 420 230 63 370 329 100 14x10 G1" M22x1.5 1)
OK-ELH 4 450 294 306 306 500 300 80 445 421 150 19x10 G1" M22x1.5 2)
1)
OK-ELH 3 and OK-ELH 4 have two connections M22x1.5.
OK-ELH 5
A/2 A/2
(4x) F
ROTATION
Z3 Z1 (2x)
HYDAC
15 Drain port
AIR M12x1.5
A depth13
E4
E1
A
E1
35
AIR 4x
M
6
de
pt
A (1:2.5) h
5
E2
E3 B
E5
C
A B B B C E1 E2 E3 E4 E5 F Z1 Z3
[mm] 5 10 10 10 5 5 5 5 5 5 /slot
6.3 cc 14 cc 22 cc
E 5.808.1/03.15
OK-ELH 5 460 311 323 338 602 350 55 495 200 2) 580 2) 12 G1-1/4" M22x1.5 2)
1)
The cooling element has two connections M22x1.5.
2)
OK-ELH 5 has the front fixing holes in the lateral sides.
100
OK-ELH 6
Top fixing points
Z1 (3x) M8 (2x)
A/2 A/2
ROTATION B2
AIR
15
Drain port
A M12x1.5
depth13
E1
A
35
Z3
4x
M
AIR
6
de
A (1:2.5)
pt
E2
h1
3
E3
D2 Plug
D1 (4x) F
C
D3
B1
A B1 B1 B1 B2 C D1 D2 D3 E1 E2 E3 F Z1 Z3
[mm] 5 10 10 10 5 5 2 2 2 5 5 5 /slot
6.3cc 14 cc 22 cc
OK-ELH 6 638 378 391 405 67 598 255 482 295 497 80 98 9 G1-1/4" M22x1.5
AIR 15
Drain port
M12x1.5
depth13
E1
A
35
A
13
pth
AIR Z3 A (1:2.5)
6 de
xM
4
E2
D2 Plug E3
C (4x) F D1
D3
A B1 B1 B1 B2 C D1 D2 D3 E1 E2 E3 F Z1 Z3
[mm] 5 10 10 10 5 5 2 2 2 5 5 5 /slot
6.3cc 14 cc 22 cc
OK-ELH 7 726 444 459 42 602 410 560 450 597 75 73 9x20 G1-1/4" M22x1.5
E 5.808.1/ 03.15
Note:
We recommend maintaining a minimum distance to ensure an unimpeded air inlet and air outlet.
This is half the height of the cooling element (A/2).
Anything below the minimum distance can influence the cooling capacity and the noise emissions.
101
Note
The information in this brochure
relates to the operating conditions.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications.
102
Air Cooler Mobile
OK-ELD 0-6
with DC motor
Application Field
Hydraulic systems in mobile machines
and vehicles, such as
ll Mobile cranes
ll Concrete mixers and pump trucks
ll Road paving machines
E 5.805.2/03.15
ll Construction machines
(excavators, wheel loaders)
ll Agricultural machines
ll Municipal machines
103
Options Design
Integrated pressure bypass OK-ELD 0
valve (IBP) / Integrated thermal
pressure bypass valve (IBT)
The bypass channel is integrated in the
cooling element. If a particular pressure
is exceeded, the IBP opens the bypass
channel, thereby protecting the cooling
element from too high a pressure.
Furthermore, the IBT only opens the
cooling element path once a particular
temperature has been reached.
OK-ELD 1.5
1
E 5.805.2/ 03.15
104
Design
OK-ELD 1-4.5
OK-ELD 5-6
1
E 5.805.2/03.15
105
Technical Data
OK-ELD 0-6
Fan motor:
Air flow [m3/h]
[kW / A] 2)
Type of cooler
Weight [kg]4)
Volume [l]3)
Voltage [V]
[dB(A)]
P/N
[A]
kW A
OK-ELD 1 3083371 12 150 451 0.10 8.0 15.0 190 73 0.6 4.0
OK-ELD 1 3083596 24 150 451 0.10 3.2 7.5 190 73 0.6 4.0
OK-ELD 1.5 3106405 12 150 455 0.10 8.0 15.0 190 77 1.0 4.7
OK-ELD 1.5 3106406 24 150 455 0.10 4.0 7.5 190 77 1.0 4.7
OK-ELD 2 3083370 12 150 910 0.14 9.4 20.0 255 74 2.0 9.4
OK-ELD 2 3083597 24 150 910 0.14 5.2 15.0 255 74 2.0 9.4
OK-ELD 3 3083369 12 180 1,338 0.23 17.5 25.0 305 79 2.2 11.0
OK-ELD 3 3083678 24 180 1,338 0.23 8.0 20.0 305 79 2.2 11.0
OK-ELD 4 3809511 12 180 2,052 0.30 22.5 30.0 385 76 3.0 15.9
OK-ELD 4 3809078 24 180 2,052 0.30 10.5 20.0 385 76 3.0 15.9
OK-ELD 4.5 3979800 12 180 2,284 0.30 22.5 30.0 385 76 5.2 22.0
OK-ELD 4.5 3979801 24 180 2,284 0.30 10.5 20.0 385 76 5.2 22.0
OK-ELD 5 3083286 12 180 3,581 0.46 35.0 2x25 305 80 4.2 30.3
OK-ELD 5 3083681 24 180 3,581 0.46 16.0 2x20 305 80 4.2 30.3
OK-ELD 6 3982479 12 180 5,020 0.60 45.0 2x30 385 77 5.2 36.6
OK-ELD 6 3982420 24 180 5,020 0.60 21.0 2x20 385 77 5.2 36.6
1)
Max. flow rate
2)
OK-ELD 5-6: each fan
3)
Fluid in cooling element
4)
Unfilled
Counter connector
12V 3973604
OK-ELD 0
24V 3973656
106
Cooling Capacity and Pressure Difference p
OK-ELD 0-6
Cooling capacity:
Dependent on the oil flow rate and
the temperature difference T between
40 1,0 oil inlet and air inlet.
OK-ELD 4
16 0,4
12 OK-ELD 3 0,3
8 OK-ELD 2 0,2
OK-ELD 1.5
4 0,1
OK-ELD 1
OK-ELD 0
0 0
0 20 40 60 80 100 120 140 160 180 200
Pressure difference p
2.2
OK-ELD 6
2.0
1.8
OK-ELD 5
1.6
Pressure drop [bar]
1.4
1.2 OK-ELD 4
OK-ELD 2
1.0
OK-ELD 3
0.8
0.4
0.2
0.0
0 20 40 60 80 100 120 140 160 180 200
measured at 30 mm/s
Tolerance: 5 %
107
Model Type
OK-ELD-1H-3.1-12 VBL-1-S-AITF60
Cooler type
OK-ELD = Oil-Air cooler
Size / motor speed
0-6 = size
H = 2 pl (3,000 min-1)
Revision
Motor voltage
12 V = 12 V DC
24 V = 24 V DC
12 VBL = 12 V DC brushless
24 VBL = 24 V DC brushless
Color
1 = RAL 9005 (standard)
Other colors on request.
Air flow direction
S = Suction (standard)
D = Blowing
Accessories
IBP = Heat exchanger with integrated bypass valve
IBT = Heat exchanger with integrated thermo-bypass valve
AITF = Thermostat (fixed)
ESC = Electronic speed control
For all possible accessories, like vibration absorber, air filter grid or air filter mat,
please refer to brochure Accessories for air coolers.
E 5.805.2/ 03.15
108
Dimensions
OK-ELD 0
A/2 A/2
ROTATION
Z1 (2x)
AIR
E1
A
AIR
E2
E5 E3 E4 (4x) F
C B
Dimensions
OK-ELD 1.5
E3 E1 Z3 A/2 A/2
Z1 (2x)
ROTATION
AIR
A
E4
E2
(4x) F
AIR
E5
C B
E 5.805.2/03.15
109
Dimensions
OK-ELD 1-4
ROTATION
HYDAC
HYDAC
AIR
E1
E4
A AIR
E2
E3 Z1 (2x)
[mm] A B C E1 E2 E3 E4 E5 F Z1 Z3
5 10 5 5 5 5 5 2 /slot
OK-ELD 0 202 140 240 72 79 10 60 190 6.5 G"
OK-ELD 1 245 120 300 125 60 250 225 180 1)
9.0 M22x1.5 M22x1.5
OK-ELD 1.5 217 137 330 43 172 255 121 40 M8 M22x1.5 M14x1.5
OK-ELD 2 313 207 384 199 57 324 288 80 14x10 G1" M22x1.5
OK-ELD 3 356 207 420 230 63 370 329 100 14x10 G1" M22x1.5
OK-ELD 4 450 208 500 300 75 445 421 150 19x10 G1" M22x1.5 2)
OK-ELD 4.5 454 227 602 350 52 495 200 580 1)
12.0 G1-" M22x1.5 2)
1)
OK-ELD 1 and OK-ELD 4.5 have only the four external fixing points
2)
OK-ELD 4 and OK-ELD 4.5 have two connections M22x1.5
E 5.805.2/ 03.15
110
Dimensions
OK-ELD 5-6
ROTATION ROTATION
HYDAC
AIR
E1
E4
A
AIR
E2
E3 Z1 (2x) B
[mm] A B C E1 E2 E3 E4 E5 F Z1 Z3
5 10 5 5 5 5 5 2 /slot
OK-ELD 5 480 232 810 321 79 750 450 170 10x20 G1-" M22x1.5
OK-ELD 6 532 233 950 373 81 888 503 200 9x21 G1-" M22x1.5
Note:
We recommend maintaining a minimum
distance to ensure an unimpeded air
inlet and air outlet. This is half the
E 5.805.2/03.15
112
Mobile Coolers
CMS Cooling Mobile System
General
The Emissions Directive for engines in mobile machinery has been structured to
reduce emissions progressively which can lead to a drastic increase in the required
heat dissipation and a corresponding adjustment in cooler size. The limited installation
space available in a mobile machine must therefore be utilised efficiently and
intelligently.
In mobile machines, multiple cooling circuits can be combined together
in various ways in a CMS mobile cooler:
ll Charge air cooling
ll Coolant cooling
ll Oil-cooling:
gearbox, hydraulics,
fan drive, axles
Hydraulic oil cooling on loader crane: ll Fuel cooling
air cooler with DC motor ll Condenser
If required, a heat exchanger for the A/C condenser can
also be integrated into the cooling system
Product Features
The cooler comprises a set of cooling elements in different layouts,
either side-by-side or front-to-back. With the addition of a fan cover,
a protective grille and a fan (also available with motor) this cooler package
is supplied to the customer ready for installation.
KULI simulation software is used to determine the optimal combination and
configuration of heat exchangers and fan. In addition, CFD software can be used
to visualise and calculate air flow and heat management in the engine compartment.
This helps to reduce development costs.
Hydraulic oil cooling on concrete Special cooling fins ensure suitability for use in dusty environments,
pump: air cooler with hydraulic motor for example, in agriculture and forestry or for applications in the mining sector.
and integrated filter
E 5.812.1/03.15
Application Field
ll Municipal vehicles and municipal machines ll Mobile cranes
ll Cement mixers and concrete pump trucks ll Wheel loaders
ll Agricultural and forestry machinery ll Backhoe loaders
e.g. tractors, harvesters, sprayers, combine harvesters ll Wheeled excavators
ll Road construction machinery, and crawler excavators
e.g. paver finishers, rollers, bulldozers, graders ll Snow grooming vehicles
ll Dump truck ll Vibrator survey trucks
D
RA
H T Motor
C Y /
CO
A D C
ND
C
EN
SE
R
Configuration of the cooling elements in the engine compartment Combination cooler for sprayer:
air cooler for 4 cooling circuits
with hydraulic fan control
Note
The information in this brochure HYDAC COOLING GMBH Industriegebiet
relates to the operating conditions and 66280 Sulzbach /Saar
applications described. Germany
For applications and operating conditions Tel.: +49 6897 509-01
not described, please contact the Fax: +49 6897 509-454
relevant technical department. E-mail: cooling@hydac.com
Subject to technical modifications and Internet: www.hydac.com
corrections.
HYDAC AG Via Sceresa, Zona Industriale 3
Mezzovico 6805 Mezzovico
branch office Switzerland
E 5.812.1/ 03.15
114
Air Cooler Accessories
LFG
AITR AITF IBP IBT GP Fe ESC LFM
LS
Cooler
Size
1
AC-LN
2-14
ACA-LN
2-14
ACAF-LN
OK-ELC 1
2-7
0
OSCA
OSCAF
1-3
OK-ELD 1-1,5 with feet
2-6 with feet *
2-5 with feet
OK-ELH
6-7
AC-LNH 8-14
Note:
Overall dimensions could be increased due to the presence of accessories.
Please contact the technical sales department for combination of accessories.
115
Thermostat adjustable
TR/AITR
General
The TR/AITR is an electrical switch,
opening or closing the circuit at the
selected temperature.
TR could be mounted in the tank;
AITR is mounted in one of the cooling
element free ports.
TR/AITR are supplied with a probe
holder.
E 5.822.0/ 03.15
116
Dimensions
1/2 NPT
92
12
97
20
161.50 55
Installation
The position of the thermostat is in relation of the element design and position of ports.
OUT
IN
Model Type
Please check cooler compatibility in the table.
117
Thermostat fixed
AITF
118
Dimensions
63
M22x1.5
48
SW27
Model Type
Please check cooler compatibility in the table.
as accessory: / AITF 50
Switch-on temperature
AITF = Connection block with thermostat
E 5.822.0/03.15
119
Integrated
Pressure Bypass Valve
IBP
General
The IBP is a valve that closes the bypass
channel of the cooler. When the pressure
exceeds a certain value in the cooling
the IBP opens the bypass channel and
allows a part of the fluid to bypass the
element.
Note:
This valve requires a special cooling
element with integrated bypass channel.
Therefore, it cannot be retrofitted.
E 5.822.0/ 03.15
120
Installation
Inlet port is always placed on the tank where the IBP is assembled.
IBP
IBP
OUT
IN
Model Type
Please check cooler compatibility in the table.
as accessory: / IBP 2
Opening pressure (see table of IBP versions)
IBP = Integrated bypass valve
121
Integrated
Temperature Bypass Valve
IBT
Note:
This valve requires a special cooling
element with integrated bypass channel.
Therefore, it cannot be retrofitted.
E 5.822.0/ 03.15
122
Installation
Inlet port is always placed on the tank where the IBT is assembled.
IBT
IBT
OUT
IN
Model Type
Please check cooler compatibility in the table.
as accessory: / IBT 45 - 2
Opening pressure: 2, 3, 4 or 6 bar
Temperature at which IBT closes the bypass
(see table of IBT versions)
IBT = thermostatic bypass valve
as spare part: IBT 45 - 2
Opening pressure: 2, 3, 4 or 6 bar
Temperature at which IBT closes the bypass
(see table of IBT versions)
IBT = thermostatic bypass valve
E 5.822.0/03.15
123
Vibration Absorbers
GP
AC-LN 1-3
ACA-LN 2-3
6
20
OK-ELC1-7
6.5
M6
OK-ELH 6
AC-LNH 8 25
AC-LN 4-8
ACA-LN 4-6 20
OSCA 1-3
7
3
M8
OK-ELH 7
AC-LNH 9 30
ACA-LN 7-11
30
M8
7
40
AC-LN 9-11
4
20
AC-LN 12-14
45
E 5.822.0/ 03.15
M10
70
124
Mounting
GP Mounting Kit
Model Type
Please check cooler compatibility in the table.
as accessory: / GP
GP = Vibration absorber
125
Feet
General Mounting
OK-ELD and OK-ELH models are The foot has to be mounted using a screw already existing in the cooler
not equipped with feet as standard. (fixing the element to the housing) plus an additional screw supplied with the foot.
For these series feet are optional
available. Feet Mounting Kit
E 5.822.0/ 03.15
126
Dimensions
(4x) C
B
48
15
[mm] A B C [mm] A B C
Model Type
Please check cooler compatibility in the table.
as accessory: / FU
FU = Feet
FU = Feet
127
Electronic Speed Control
ESC
128
Options
500 10
STANDARD rotation:
ESC controls fan speed proportionally
with the fluid temperature.
REVERSE rotation 1 (Rev1): 1
Connector type:
Metri-pack 280 2 pole male pin
Standard + reverse rotation
The reverse rotation starts as soon as
2 Connector type:
the fan stops the normal rotation due to AMP Superseal 1.5 2 pole female pin
low temperature.
3 Connector type:
Metri-pack 280 2 pole female pin
REVERSE rotation 2 (Rev 2):
Standard + reverse rotation (cycle)
The reverse rotation starts in a 1 Input to ESC 2 Input signal 3 Output to fan motor
preset cycle, independent of the fluid
temperature.
Mounting
34 0.2
HYDAC
23.5 0.2
LABEL
86 0.5
76 0.2
56 0.5
3
5.
x)
(2
Model Type
Please check cooler compatibility in the table.
For information about temperature settings and cycles please contact technical sales department.
129
Element Protection Grid
LFG/LFM/LS
General LFG
Protective grid mounted in front of the Protective grid with a metal mesh to filter the air and prevent element clogging
element to protect the element from from sand, leaves, dust and small stones.
stones, sand, leaves, dust and any other
external agent that can clog the air side Mounting Kit
of element.
Only for sucking version of coolers
available.
LFM
Protective grid equipped with filter element to filter dirty air across air side
of the element.
The filter element can be exchanged easily.
Used to filter air from small particles of sand, dust and can offer protection
against stones.
Mounting Kit
E 5.822.0/ 03.15
130
LS
Protective grid against stones.
Mounting Kit
Model Type
Please check cooler compatibility in the table.
as accessory: / LFG
LFM = Air filter mat
LFG = Air filter grid
LS = Protection grid against stones
E 5.822.0/03.15
131
Note
The information in this brochure
relates to the operating conditions.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications.
132
Plate Heat Exchangers
General
Plate heat exchangers are used wherever thermal energy (heat)
has to be transferred from one fluid to another.
The advantage is that they can maintain the fluid temperature at a very
low and stable level depending on the temperature of the coolant.
Plate heat exchangers consist of a stack of stamped heat exchange plates
which are either brazed together or bolted together in a frame with gaskets.
Medium flows in the channels between the plates where hot medium (which will be
cooled) alternates with cold medium (which will be heated). The design of the plates
induces the turbulent flow required for efficient heat transfer.
133
Function
Fluids flow in counterflow through the plate heat exchanger:
In counterflow, the hot medium is cooled more rapidly than in parallel flow because the cold medium flows in the opposite direction
to the hot fluid.
C C
Distance x Distance x
Parallel flow principle: Counterflow principle:
Average temperature difference m decreases. Average temperature difference m remains constant.
With brazed plate heat exchangers it is possible to reverse With gasketed plate heat exchangers it is not possible to
the inlet and outlet connections of a medium without adversely change the connections because of the more complex plate
affecting the function. However, to guarantee the counterflow stamp pattern. In this case the connections can be selected
principle, the inlet and outlet of the other medium must also before manufacture of the plate heat exchanger.
be changed. However, changing the cold and hot side is not Please consult our technical sales department.
recommended. The plate heat exchangers are designed to have
E 5.815.0/ 03.15
hot fluid always flowing through the outer plate. If cold medium
flows through, condensation could form on the outside of the
heat exchanger.
134
Application Field Sizing Program
A plate heat exchanger can be used The sizing program for brazed plate heat exchangers
wherever there should be heat transfer helps you to select the right size and number of plates.
between two media. Please ask for the latest version from the technical sales department.
Typical applications are:
ll Hydraulic systems
ll Presses
ll Lubrication systems
ll Test rigs
ll Motors/engines
Sectional View
Cooling Capacity
The maximum cooling capacity of
a plate heat exchanger depends on
several factors:
ll the inlet temperature of
the hot and cold medium
ll the flow rate of the hot and
cold medium
ll the media used.
For gasketed plate heat exchangers please fill in the Specification Sheet
in this brochure and send it to the technical sales department.
We will help you to find the appropriate plate heat exchanger for
your specific application.
E 5.815.0/03.15
135
Specification Sheet for Plate Heat Exchangers
In order to be able to make the correct selection, it is necessary to have various data to hand.
The following check-list is designed to help.
Project:
Contact:
Telephone:
E-mail:
General
Design pressure bar
Hot side
Medium to be cooled Oil ISO VG SAE
Water
Water glycol % Glycol: %
Other medium
(Please attach technical datasheet for medium, if available.)
Inlet temperature: C
or
Outlet temperature: C
Cold side
Cooling medium: Oil ISO VG SAE
Water
Seawater (Gasketed PWT only)
Other medium
(Please attach technical datasheet for medium, if available.)
Inlet temperature: C
Comments
E 5.815.0/ 03.15
136
Brazed
Plate Heat Exchangers
HYDAC HEX Sxxx
Product Features
Brazed heat exchangers consist of a
stack of stamped heat transfer plates
with connections in stainless steel.
The plates are vacuum brazed with
copper or nickel.
The plates have smoothed edges and
the end plate is provided with edge
protection.
The special stamp pattern of the
plates induces a turbulent flow which
is necessary for optimum heat transfer
and which in addition has a self-cleaning
effect because the high level of wall
friction reduces deposits on the surface.
E 5.815.0/03.15
137
Application Field Model Type
Cooling circuits operated using water,
coolant, HFC operating fluid or oil. HYDAC HEX S400 -10 -00NI/G3/4"
Typical applications are: Size
ll Machine tools HYDAC HEX S400
HYDAC HEX S610
ll Presses HYDAC HEX S615
ll Injection moulding machines HYDAC HEX S522
ll Motors/engines HYDAC HEX S722
HYDAC HEX Z800
ll Test rigs
Other sizes on request
ll Generators
Number of plates
10 14 20 30 40 50 60 70 80 90 100 120 150 160 180 190
HYDAC HEX S400
HYDAC HEX S610
HYDAC HEX S615
Water
<6.0 0 0
Com- Con- pH value 6.0 9.0 0/+ +
Con- Cooling denser
sumer pressor
water >9.0 + 0
Economizer
<500 [ S/cm] + +
Electrical conductivity
>500 [ S/cm] + 0
Coolant Bypass
Coolant
Cl- (max. +60 C) <300 + +
receiver
<50 + +
SO4-2 50 300 + 0
Chiller
>300 0 0
Water- <50 + +
CaCO3
cooled Air inlet >50 0 0
motor
30 C <0.3 + +
Fe
>0.3 + 0
Cooling
water
<2 + +
30 C 30 C NH3 2 20 + 0
Pump Air outlet 25 C >20 + 0
25 C 25 C Cooling Transmission <100 + +
water oil NO3
Cooling >100 + 0
water
S-2 Not suitable
Vacuum pump
SiO2 <30 + +
NH4+ <0.1 + +
Free chlorine <0.1 + +
CO3-2 <0.4 + +
E 5.815.0/ 03.15
0: Corrosive
+: Suitable
For nickel-brazed versions, please contact the technical sales department.
138
Dimensions
HYDAC HEX S400
80 2
76 2
40
190 2
194 2
154
Female thread
G"
l = 18 mm
SW32 L 27
Dimension L Weight
HYDAC Part No. HYDAC Type Code
[mm] [kg]
3455621 HYDAC HEX S400-10-00/G3/4" 33 1.3
3383847 HYDAC HEX S400-14-00/G3/4" 42 1.5
3455623 HYDAC HEX S400-20-00/G3/4" 55 1.8
3399435 HYDAC HEX S400-30-00/G3/4" 78 2.3
3455655 HYDAC HEX S400-40-00/G3/4" 101 2.8
306 2
250
Female thread
G1"
l = 20 mm
SW41 L 27
Dimension L Weight
HYDAC Part No. HYDAC Type Code
[mm] [kg]
3366746 HYDAC HEX S610-10-00/G1" 34 2.5
3361012 HYDAC HEX S610-20-00/G1" 58 4.2
3366754 HYDAC HEX S610-30-00/G1" 82 5.5
3366759 HYDAC HEX S610-40-00/G1" 106 6.9
3366760 HYDAC HEX S610-50-00/G1" 130 8.25
3366761 HYDAC HEX S610-60-00/G1" 154 9.6
3366762 HYDAC HEX S610-70-00/G1" 178 10.9
E 5.815.0/03.15
139
106 2
HYDAC HEX S615 102 2
50
518 2
522 2
466
Female thread
G1"
l = 20 mm
SW41 L 27
Dimension L Weight
HYDAC Part No. HYDAC Type Code
[mm] [kg]
3366787 HYDAC HEX S615-10-00/G1" 34 5.3
3366788 HYDAC HEX S615-20-00/G1" 58 7.5
3366790 HYDAC HEX S615-30-00/G1" 82 9.7
3366792 HYDAC HEX S615-40-00/G1" 106 11.9
3366793 HYDAC HEX S615-50-00/G1" 130 14.1
3366794 HYDAC HEX S615-60-00/G1" 154 16.3
3366815 HYDAC HEX S615-80-00/G1" 202 20.7
3383853 HYDAC HEX S615-100-00/G1" 250 25.7
186 2
HYDAC HEX S722 182 2
92
609 2
613 2
519
Female thread
G1"
l = 25 mm
SW66 L 27
Dimension L Weight
HYDAC Part No. HYDAC Type Code
[mm] [kg]
3457465 HYDAC HEX S722-20-00/G1 1/2" 62 15.3
3457473 HYDAC HEX S722-30-00/G1 1/2" 86 19.4
3457474 HYDAC HEX S722-40-00/G1 1/2" 110 23.5
3457486 HYDAC HEX S722-50-00/G1 1/2" 134 27.6
3457489 HYDAC HEX S722-60-00/G1 1/2" 158 31.7
3457490 HYDAC HEX S722-70-00/G1 1/2" 182 35.8
3457491 HYDAC HEX S722-80-00/G1 1/2" 206 40.0
3457493 HYDAC HEX S722-90-00/G1 1/2" 230 44.0
3457494 HYDAC HEX S722-100-00/G1 1/2" 254 48.0
E 5.815.0/ 03.15
140
HYDAC HEX S522 246 2
241 2
174
523 2
528 2
456
Female
thread
G1"
l = 25 mm
SW55 L 27
Dimension L Weight
HYDAC Part No. HYDAC Type Code
[mm] [kg]
3383854 HYDAC HEX S522-20-00/G1 1/2" 60 17.6
3383906 HYDAC HEX S522-30-00/G1 1/2" 84 22.8
3383908 HYDAC HEX S522-40-00/G1 1/2" 108 28.0
3383909 HYDAC HEX S522-50-00/G1 1/2" 132 31.2
3383910 HYDAC HEX S522-60-00/G1 1/2" 156 38.4
3383911 HYDAC HEX S522-70-00/G1 1/2" 180 43.6
3383913 HYDAC HEX S522-80-00/G1 1/2" 204 48.8
3383914 HYDAC HEX S522-100-00/G1 1/2" 252 59.2
3651724 HYDAC HEX S522-110-00/G1 1/2" 276 60.8
3383925 HYDAC HEX S522-120-00/G1 1/2" 300 69.6
3383926 HYDAC HEX S522-150-00/G1 1/2" 372 85.2
3738950 HYDAC HEX S522-160-00/G1 1/2" 396 84.8
3383927 HYDAC HEX S522-190-00/G1 1/2" 468 106.0
a
(650)
650
746
751
a a
70 50 L 50
180
270
141
Installation
Clamping band
Cylinder
head screw
Mounting plate
Guide roller
Octagon nut
Rubber profile
M8
C 2
(10) B
L
HYDAC Part No. HYDAC Type Code c [mm] d [mm] l [mm] b [mm]
3092917 HYDAC HEX S400 194 80 239 219
3014028 HYDAC HEX S610 306 106 351 331
3014029 HYDAC HEX S615 522 106 566 546
3343306 HYDAC HEX S522 528 246 573 553
3013884 HYDAC HEX S722 613 186 658 638
E 5.815.0/ 03.15
142
Gasketed
Plate Heat Exchangers
Hxxx-LIQUID
143
Application Field Model Type
Cooling circuits in counterflow which
are operated using water, coolant, H-38-IG 10-12-TKTM33-LIQUID
HFC operating fluids or oil. For Size
applications using other fluids please
contact the specialist department. Frame type
Typical applications are: Pressure range
ll Hydraulic systems Number of plates
ll Presses
Plate type
ll Lubrication systems
Fluid
ll Test rigs
ll Motors/engines
Water Quality
Substances dissolved Concentration Notes below
in water of substance in mg/l relate to 1.4401
<0.2 A
Aluminium (Al) in solution
>0.2 A
<2 A
Ammonia NH3 2 20 A
>20 A
<250 A
Chloride Cl- (max. +60 C)
>250 B
<10 S/cm A
Electrical conductivity 10 500 S/cm A
>500 S/cm A
<0.2 A
Iron Fe in solution
>0.2 A
<5 A
Free aggressive carbonic
5 20 A
acid CO2
>20 A
Total hardness 4.0 8.5 dH A
<20 % A
Glycol percentage 20 50 % A
>50 % A
<1.0 A
HCO3- SO4-2
>1.0 A
<70 A
Hydrogen carbonate HCO3- 70 300 A
>300 A
<0.1 A
Manganese Mn in solution
>0.1 A
<100 A
Nitrate in solution NO3
>100 A
<6 B
6.0 7.5 A/B
pH value
7.5 9.0 A
>9 A
<70 A
Sulphate SO4-2 70 300 A
>300 C
<1 A
Sulphite SO3 /
15 A
Free chlorine gas Cl2
>5 A/B
<0.05 A
Hydrogen sulphide (H2S)
>0.05 A
H8 / H16
40
F1 18
70 F2 20
L
16 60
200 0 L+ 100
C
L+
H
Installation
F4
30
F3
200
12
200 30
F1 F1
126 126
F2 F2
H
H
C
C
F4 F4
160
F3 F3
160
L L
300 300
Frame 16 bar Frame 25 bar
L+
H28 994 mm 694 mm
Installation H40 1,194 mm 894 mm
145
H18 / H38 / H62
F1 F1
192 192
F2 F2
H
H
C
C
344 351
F4 F4
132
132
F3 F3
L L
395 395
18
140
35
H + 70
18
20
B- L
100 18 55
B L+
Installation
F1
225
H
F2
C
Frame
F4
205
F3
146
H74 / H102
140
35
H + 70
18
20
L
380 55
480
18
L+
F1 Installation
238 F2
H
C
F4
200
F3
L
18
20
B-
100 18 50
B L+
F1 Installation
296
F2
H
C
Frame
F4
275
F3
L
147
Note
The information in this brochure
relates to the operating conditions
and applications described.
For applications and operating
conditions not described, please contact
the relevant technical department.
Subject to technical modifications.
148
Feed Pumps
FZP/ MFZP
149
Design
Rotor
Motor flange
Control disk
Pump flange
Interior ring
Retaining ring
O-ring
Liner
O-ring
Vane
Pressure limitation valve
O-ring
Note:
ll As few threaded connections as possible
ll Few pipe bends where bends are used, with large bending radius
ll Difference in height between pump and oil level as small as possible
E 5.701.6/ 03.15
150
Control Curves
FZP-1 FZP-2 FZP-3
V [mm2/s]
V [mm2/s]
1,000 1,000 1,000 F
F
E
800 800 800
E
600 600 600
D
400 400 400
C D E
B
200 200 200
D
A
A B C A B C
0 0 0
0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
p [bar] p [bar] p [bar]
E 5.701.6/03.15
151
Viscosity-temperature graph
to DIN 51519 viscosity index 50
10,000
5,000
4,000
IS
3,000 O
VG
2,000 IS
O 15
IS VG 00
O 1
1,000 IS VG 000
O 6
IS VG 80
500 O 46
400 IS VG 0
O 32
Kinematic viscosity in mm/s
300 IS VG 0
O 2
V 2
200 IS G 1 0
O
V 50
IS G 1
O
100 V 00
IS G 6
O
V 8
50 ISO G 46
V
40 ISO G 3
30 V 2
ISO G 22
20 VG
ISO 15
VG
ISO 10
10
VG
ISO 7
VG
5 5
4
ISO
VG
3 ISO V 3
G2
2
1
10 20 30 40 50 60 70 80 90 100
Temperature in C
Design
Pump (FZP or MFZP) selected in accordance with customer specifications.
Example:
Flow rate: 190 l/min
Counter-pressure: 5 bar
Viscosity: 200 cSt
Motor voltage: 400 V 50 Hz
Selection:
190 l/min FZP-3 / MFZP-3 (approx. 130 ccm/rev at 1,500 rpm)
5 bar and 200 cSt drive power 4 kW (= motor size 112)
Result:
FZP-3/3.0/P/100/130/RV6
MFZP-3/3.0/P/112/130/RV6/4/400-50
E 5.701.6/ 03.15
152
Dimensions
FZP B
H I
E4
S P
E3
E2
E1
G
A
K
C
J
L
45
D
[mm]
19 20 35 7
2 30 60 160 100 100 33 110 G 1 30.00 35.00 G1 130 9
24 25 35 7
E 5.701.6/03.15
153
Dimensions
MFZP
G F
E
C
A B H I
K D
[mm]
A B C D E F G H I
154
Model Type
MFZP-2-2.1-P-90/40-RV6-1.5/400-50
Motor pump group MFZP
(with motor)
Modification number
(see flow rate table)
Seals
P = Perbunan
V = Viton
(other seals on request)
Size 1:
0.18 kW
0.37 kW
Size 2:
0.75 kW
1.50 kW
Size 3:
2.20 kW
4.00 kW
155
Design Data Sheet, Feed Pumps
Project:
Contact:
Telephone:
E-mail:
Fluid temperature: C
Fluid purity:
Suction height: m
Electrical data
Motor rating: kW
Voltage: V Hz
Speed: rpm
Direction of rotation:
Installation position
of the pump:
Ambient temperature: C
Remarks /miscellaneous:
E 5.701.6/ 03.15
156
E 5.701.6/03.15
157
Note
The information in this brochure
relates to the operating conditions and
applications described.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications and
corrections.
158
Feed Pumps
VP/ VPB/ VPBM
159
Design
O-ring
Interior ring
Pump flange
(shown rotated by 90)
Motor flange
Rotor
P
Shaft
DU bearing DU bearing
Note:
ll As few threaded connections as possible
ll Few pipe bends where bends are used, with large bending radius
ll Difference in height between pump and oil level as small as possible
E 5.702.4/ 03.15
160
Control Curves
VP-2
1,000
800
V [mm2/s]
600
400 A 40 cm / rev0.75 kW
B 30 cm / rev0.75 kW
C 20 cm / rev0.75 kW
200
D 40 cm / rev1.50 kW
E 30 cm / rev1.50 kW
A B C D E F
0
F 20 cm / rev1.50 kW
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
p [bar]
VP-3
1,000
800
V [mm2/s]
A 130 cm / rev2.2 kW
600
B 130 cm / rev2.2 kW
C 70 cm / rev2.2 kW
400 D 130 cm / rev4.0 kW
E 100 cm / rev4.0 kW
F 70 cm / rev4.0 kW
200 H G 130 cm / rev5.5 kW
B F H 130 cm / rev7.5 kW
A C D E I
G I 100 cm / rev5.5 kW
0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
p [bar]
E 5.702.4/03.15
161
Viscosity-temperature graph
to DIN 51519 viscosity index 50
10,000
5,000
4,000
IS
3,000 O
VG
2,000 IS
O 15
IS VG 00
O 1
1,000 IS VG 000
O 6
IS VG 80
500 O 46
400 IS VG 0
O 32
Kinematic viscosity in mm/s
300 IS VG 0
O 2
V 2
200 IS G 1 0
O
V 50
IS G 1
O
100 V 00
IS G 6
O
V 8
50 ISO G 46
V
40 ISO G 3
30 V 2
ISO G 22
20 VG
ISO 15
VG
ISO 10
10
VG
ISO 7
VG
5 5
4
ISO
VG
3 ISO V 3
G2
2
1
10 20 30 40 50 60 70 80 90 100
Temperature in C
Design
Pump (VP, VPB or VPBM) selected in accordance with customer specifications.
Example:
Flow rate: 190 l/min
Counter-pressure: 5 bar
Viscosity: 200 cSt
Motor voltage: 400 V 50 Hz
Selection:
190 l/min VP-3 / VPBM-3 (approx. 130 ccm/rev at 1,500 rpm)
5 bar and 200 cSt drive power 4 kW (= motor size 112)
Result:
VP-3/1.0/P/-/130
VPBM-3/1.0/P/112/130/4/400-50
E 5.702.4/ 03.15
162
Dimensions
VP
D H G
Inlet Outlet
F f7
A
N
M
Parallel keys to
DIN 6885 Part 1
P
B C
VP-3 100 200 205 119.0 7 44 32 125 44 50 17.0 13.5 160 180
Ports
Inlet: G1"
Outlet: G1"
E 5.702.4/03.15
163
Dimensions
VPB
A D
N
B
E C I
F
H
VPBM
164
Model Type
VPBM-2-1.0-P-90/40-1.5/400-50
Pump
VP = pump
VPB = pump + PT + coupling
VPBM = pump + PT + coupling + motor
(PT = bell housing)
Assembly
2
3
Modification number
Seals
P = Perbunan
V = Viton
(other seals on request)
Motor version:
B5
165
Design Data Sheet, Feed Pumps
Project:
Contact:
Telephone:
E-mail:
Fluid temperature: C
Fluid purity:
Suction height: m
Electrical data
Motor rating: kW
Voltage: V Hz
Speed: rpm
Direction of rotation:
Installation position
of the pump:
Ambient temperature: C
Remarks /miscellaneous:
E 5.702.4/ 03.15
166
E 5.702.4/03.15
167
Note
The information in this brochure
relates to the operating conditions and
applications described.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications and
corrections.
168
Pump-Transfer
Cooler Filtration Unit
UF 1-3 / UKF 1-3
169
Design
There are different versions possible depending on the requirements:
UF Feed pump with filter
UK Feed pump with plate heat exchanger
UKF Feed pump with filter and plate heat exchanger
UKF-1
UKF-2
UKF-3
* Dependent on temperature difference and flow rate of the cold and warm medium (see also Pump-Transfer Cooler Filtration Unit Selection).
170
Water Quality
The following limits are based on a water temperature of + 60 C.
Substances dissolved in water Concentration Stainless steel Copper
<6.0 0 0
pH value 6.0 9.0 0/+ +
> 9.0 + 0
<500 [ S/cm] + +
Electrical conductivity
>500 [ S/cm] + 0
+ +
Cl- <300
0 0
<50 + +
SO4-2 50 300 + 0
>300 0 0
<50 + +
CaCO3
>50 0 0
<0.3 + +
Fe
>0.3 + 0
<2 + +
NH3 2 20 + 0
>20 + 0
<100 + +
NO3
>100 + 0
S-2 Not suitable
SiO2 <30 + +
NH4+ <0.1 + +
Free chlorine <0.1 + +
CO3-2 <0.4 + +
0: Corrosive
+: Suitable
E 5.405.0/03.15
171
Dimensions / Weight
UKF-1
Clearance for filter element removal approx. 50 mm
OUT
~ 250
~135
208
~ 550
~ 655
466
Water 250 HYDAC HEX S610 -10
OUT 110
12
G1
HYDAC HEX S615 -10
Water
IN
Water in
Water out
Oil
50
OUT
Oil out
Oil in
IN
OUT
Oil
IN
Weight (unfilled)
Basic unit (motor-pump unit + filter) + heat exchanger
Motor-pump unit Heat exchanger
Basic unit: 12 kg 610-10: 3 kg
E 5.405.0/ 03.15
610-20: 5 kg
615-10: 6 kg
615-20: 8 kg
172
UKF-2 Oil
OUT Oil
IN
30.2
UF-2
M
10
G1
MF180 58.7
~ 500
~ 450
LF500
~ 410
200
140
15
90
~ 485
430
12.5
208 Oil
IN
30.2
M
10
UKF-2
G1
58.7
MF180
~ 500
~ 450
~ 410
LF500
Water
OUT
~ 345
12.5
HYDAC HEX S610-XX
15
90
250
G1
Water
IN
15
140
50
200 Oil
OUT
Weight (unfilled)
Motor-pump unit + heat exchanger + filter
Motor-pump unit Heat exchanger Filter
0.75 kW: 16 kg 610-20: 11 kg MF180: 2 kg
E 5.405.0/03.15
173
UKF-3 Oil Oil
OUT IN
UF-3
2
M1
42.9
50
MF180 77.8
~ 625
~ 570
~ 525
LF660
6 x 11
95
240
~ 530
190
20
275
315
Oil
IN
UKF-3 42.9
50
M1
MF180 77.8
2
~ 625
~ 570
~ 525
LF660
~ 450 Water
OUT
G1
95
~ 580
466
190
Water
E 5.405.0/ 03.15
IN
6 x 11
20
275 50
Oil
OUT
174
UKF-3
Oil
IN
2
M1
42.9
50
MF180 77.8
~ 625
~ 570
~ 525
LF660
~ 375
Water Water
IN OUT
95
240
~ 670
190
6 x 11
20
275
Weight (unfilled)
Motor-pump unit + heat exchanger + filter
Motor-pump unit Heat exchanger Filter
1.5 kW: 44 kg 610-20: 11 kg MF180: 2 kg
2.2 kW: 48 kg 610-40: 14 kg LF330: 5 kg
4 kW: 52 kg 610-70: 17 kg LF500: 7 kg
610-100: 22 kg LF660: 8 kg
610-120: 25 kg
615-20: 14 kg
E 5.405.0/03.15
615-40: 18 kg
615-60: 24 kg
615-80: 30 kg
175
Model Type
UKF-2-1.0-P-40-1.5-610-40-MF180-10-D
Type
UKF = Pump + heat exchanger + filter
UF = Pump + filter
UK = Pump + heat exchanger
Version
1.0 = Heat exchanger series 610
2.0 = Heat exchanger series 615
1.2 / 2.2 = With filter bypass
Seals
P+V = Static seal Perbunan + Dynamic seal Viton
P = Static and dynamic seal Perbunan
Pump flow rate: cm3/revolution
cm3/revolution 1,000 1/min 1,500 1/min
UKF-1 3.5 5 l/min
5 7.5 l/min
7 10 l/min
10 15 l/min
UKF-2 15 15 l/min 20 l/min
UKF-2 / UKF -3 20 20 l/min 30 l/min
30 30 l/min 45 l/min
40 40 l/min 60 l/min
UKF-3 50 50 l/min 75 l/min
60 60 l/min 90 l/min
70 70 l/min 105 l/min
100 100 l/min 150 l/min
130 130 l/min 180 l/min
Motor
UKF-1 0.37 kW @ 1,500 1/min
0.55 kW @ 1,500 1/min
UKF-2 0.75 kW @ 1,500 1/min
UKF-2 / UKF -3 1.1 kW @ 1,000 1/min (6-pole motor)
1.5 kW @ 1,500 1/min
UKF-3 2.2 kW @ 1,500 1/min
2.2-6p kW @ 1,000 1/min (6-pole motor)
4 kW @ 1,500 1/min
4-6p kW @ 1,000 1/min (6-pole motor)
Filtration rating
-03 = 3 m
-05 = 5 m
-10 = 10 m
-20 = 20 m
For further details on filter elements, see relevant brochure in Fluid Filters catalogue.
E 5.405.0/ 03.15
176
Pump-Transfer Cooler Filtration Unit Selection
Determining the cooling capacity Selection of the plate heat exchanger:
Estimating the cooling capacity A sizing program is available to calculate accurately the required cooling capacity
requirements for mineral oil based on and a suitable plate heat exchanger. For this, five of the following seven variables are
increase in tank temperature required:
TxV 1 ll Oil inlet and outlet temperature
p = x ll Oil flow rate
t 35
ll Water inlet and outlet temperature
p = heat dissipation [kW] ll Water flow rate
T = temperature increase
in the reservoir [K] ll Cooling capacity
V = tank capacity [l] Additionally, the viscosity of the oil is required.
T = operating time [min]
The following graphs show the selection of plate heat exchangers
Example: based on cooling capacity.
In an system, the tank temperature
rises from +20 C to + 70 C (= 50 K)
in 30 minutes.
The tank volume is 100 l.
50x100 1
p= x
30 35
p = 4.8 [kW]
E 5.405.0/03.15
177
UKF-1
Q Oil
Operating condition: TOil = + 55 C; oil ISO VG 46; =1
Q Water
3.50
Cooling capacity kW
3.00
2.50
2.00
1.50
1.00
0.50
0
10 15 20 25 30 35 40
Water temperature C
5.00
4.00
3.00
2.00
1.00
0
10 15 20 25 30 35 40
Water temperature C
7.00
Cooling capacity kW
6.00
5.00
4.00
3.00
2.00
1.00
E 5.405.0/ 03.15
0
10 15 20 25 30 35 40
Water temperature C
178
UKF-2
Q Oil
Operating condition: TOil = + 55 C; oil ISO VG 46; =4
Q Water
9.00
8.00
7.00
6.00
5.00
4.00
10 15 20 25 30 35
Water temperature C
19.00
17.00
15.00
13.00
11.00
9.00
7.00
10 15 20 25 30 35
Water temperature C
25.00
20.00
15.00
10.00
E 5.405.0/03.15
10 15 20 25 30 35
Water temperature C
179
UKF-3
QOil
Operating condition: TOil = + 55 C; oil ISO VG 46; =4
Q Water
18.00
Cooling capacity kW
16.00
14.00
12.00
10.00
8.00
6.00
10 15 20 25 30 35
Water temperature C
40.00
35.00
30.00
25.00
20.00
15.00
10 15 20 25 30 35
Water temperature C
70.00
60.00
50.00
40.00
30.00
20.00
10 15 20 25 30 35
E 5.405.0/ 03.15
Water temperature C
180
Viscosity
Viscosity / temperature graph Viscosity / temperature graph
to DIN 51519 Viscosity index 50 Viscosity index 0 to 200 oil ISO VG 320
100,000
10,000 10,000
5,000
4,000
IS
3,000 O
VG
2,000 IS
O 15
IS VG 00
O 1
400 O 32
300 IS VG 0
O 2
V 2
200 IS G 1 0
O
V 50
IS G 1
O
100 V 00 100
IS G 6
O
V 8
50 ISO G 46
V VI = 200
40 ISO G 3 VI = 150
30 VG 2
ISO 2 VI = 100
20 VG 2 VI = 50
ISO 15 VI = 0
VG
ISO 10 10
10 VG
ISO 7
VG
5 5
ISO
4 VG
3 ISO V 3
G2
2
1 1
10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70
80
90
100
Temperature in C Temperature in C
To DIN 51519, viscosity index 50, The viscosity index indicates how much the viscosity of the oil
Temperature of medium (oil) +10 C to + 80 C; short-term changes with temperature.
operation at higher viscosities (cold start) is permitted. It is a measure of the temperature properties of different oils.
The higher the viscosity index of an oil, the smaller the change
in viscosity in relation to the temperature.
E 5.405.0/03.15
181
Graphs for Motor-pump Selection
UKF-1
Motor: 0.2 kW DC
900
3 cm/rev-0.2 kW
800 7 cm/rev-0.2 kW
10 cm/rev-0.2 kW
700
600
Viscosity mm/s
500
400
300
200
100
0
1 1.5 2 2.5 3 3.5 4
p bar
Motor: 0.37 kW
3,000
5 cm/rev-0.37 kW
7 cm/rev-0.37 kW
2,500 10 cm/rev-0.37 kW
2,000
Viscosity mm/s
1,500
1,000
500
0
1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6
p bar
E 5.405.0/ 03.15
182
UKF-2
Motor: 0.75 kW
400 15 cm/rev-0.75 kW
20 cm/rev-0.75 kW
350
30 cm/rev-0.75 kW
300 40 cm/rev-0.75 kW
Viscosity mm/s
250
200
150
100
50
0
1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6
p bar
Motor: 1.5 kW
2,000
15 cm/rev-1.5 kW
1,800 20 cm/rev-1.5 kW
1,600 30 cm/rev-1.5 kW
40 cm/rev-1.5 kW
1,400
Viscosity mm/s
1,200
1,000
800
600
400
200
0
1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6
p bar
E 5.405.0/03.15
183
UKF-3
Motor: 2.2 kW
700
30 cm/rev-2.2 kW
40 cm/rev-2.2 kW
600
50 cm/rev-2.2 kW
500
Viscosity mm/s
400
300
200
100
0
1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9
p bar
Motor: 4 kW
1,600
70 cm/rev-4 kW
1,400 100 cm/rev-4 kW
130 cm/rev-4 kW
1,200
Viscosity mm/s
1,000
800
600
400
200
0
1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9
p bar
E 5.405.0/ 03.15
184
Filter Selection
Cleanliness requirements for lubricating and hydraulic components.
The cleanliness level required in lubricating and hydraulic systems
is determined by the most sensitive component.
Depending on the conditions of the system and the environment, filters with the same filtration rating perform differently.
Typical fluid cleanliness classes achieved with HYDAC elements are shown below:
25 19/16/13 22/19/16
20 18/15/12 21/18/15
Filtration rating x
15 17/14/11 20/17/14
(x(c) 200)
10 15/12/9 19/16/13
5 12/9/6 17/14/11
3 10/7/4 13/10/7
10/7/4 11/8/5 12/9/6 13/10/7 14/11/8 15/12/9 16/13/10 17/14/11 18/15/12 19/16/13 20/17/14 21/18/15 22/19/16
185
Notes Note
On piping The information in this brochure relates
The pressure differential in a hydraulic line is dependent on: to the operating
ll Flow rate conditions and applications described.
ll Kinematic viscosity For applications and operating conditions
not described, please contact the
ll Pipe dimensions and can be estimated for hydraulic oils as follows: relevant technical department.
l [m] Subject to technical modifications.
p[bar]=5.84 x d4 x Q x v [bar]
[mm]
Notice
ll As few threaded connections as possible
ll Few pipe bends; if unavoidable, use large radius
ll Difference in height between pump and oil level as small as possible
ll Hoses must be suitable for a vacuum of min. 5,000mmW
ll Do not reduce pipe cross-section predetermined by the unit
186
Pump-Transfer
Cooler Filtration Unit
UKF for Gearboxes
187
Product Features Design
Continuous cooling and offline filtration Different versions are possible depending on the requirements:
extend the service life of the oil and of UF Feed pump with filter
the gears. The duplex filter enables the UKF Feed pump with filter and plate heat exchanger
filter to be changed without switching
off the unit. In addition, there is an Offline unit consisting of:
integrated thermal bypass valve which ll Gear pump
ensures that the system continues to run
even at low temperatures because the ll Filter (duplex filter available as an option)
cold oil is not fed through the plate heat ll Oil-water plate heat exchanger (brazed or gasketed)
exchanger. Once the oil is warm enough ll Thermal bypass valve (UKF-2 / UKF-3)
it can flow through the heat exchanger to
ll The offline circuit is fitted with check valves to isolate the filter when used with a
cool the unit.
positive head tank when changing the filter element
To guarantee a constant oil temperature
an optional water flow controller can be
fitted which supplies just enough water to UKF-1 Flow rate: 2.5 14 l/min
the plate heat exchanger as is necessary Motor rating: 0.55 kW
to achieve the required oil temperature. Cooling capacity*: 1 10 kW
Pressure, temperature or flow rate
sensors can also be added to the control
block.
* Dependent on temperature difference and flow rate of the cold and warm medium
188
Model Type
UKF-3-5.2-P+V-32-2.2-615-80-FLND400-10-D
Type
UKF = Pump + heat exchanger + filter
UF = Pump + filter
Size
1/2/3
Modification code
Seals
P+V = Static seal Perbunan + dynamic seal Viton
P = Static and dynamic seal Perbunan
Pump flow rate in ccm/rev
Motor
0.55 kW / 0.75 kW / 1.5 kW / 2.2 kW / 4 kW
Plate heat exchanger
Size 610 10-100 plates
Size 615 10-100 plates
Other sizes and gasketed plate heat exchangers on request.
Filter
Inline filter HFM75 / FLN 250 / FLN 400
Duplex filter FLND 250 / FLND 400
with filter bypass
Filtration rating in m
For further information on filter elements, see Filtration catalogue.
Differential pressure clogging indicator
D = VM 5 D.0 / -L24 (5 bar; visual-electrical)
Other clogging indicators on request.
For further information, see Filter Clogging Indicator brochure
E 5.423.0/03.15
189
Note
The information in this brochure
relates to the operating conditions
and applications described.
For applications and/or operating
conditions not described, please contact
the relevant technical department.
Subject to technical modifications
and corrections.
190
Fluid Cooling Systems
FLKS / FWKS / RFCS / HCC
General
The heat arising from internal thermal loss in main spindles, drives,
control cabinets, cooling lubricants and hydraulics can be channelled
away very effectively by fluid cooling.
Using HYDAC chiller systems with air cooling, water cooling or compressor
cooling allows all requirements to be fulfilled and a constant cooling temperature
to be achieved.
Energy-efficient control systems, such as the speed control used for fan drives,
not only reduce noise levels but also provide significant energy savings.
E 5.703.0/03.15
191
FLKS Fluid/Air Cooling Systems
Features
ll Cooling of circuits which use mineral oil or water glycol
ll Compact design with plastic tank, circulation pump,
cooling element and fan
ll Various sizes with cooling capacities up to 1.05 kW/K and
flow rates up to 150 l/min
Function
The pump conveys the cooled operating fluid from the tank through
the component that is to be cooled. The fluid absorbs heat from the
component and then flows back to the heat exchanger, where it is
returned to a cooler temperature by the air flowing from the installed fan.
Advantages
ll Cost-effective and efficient cooling system
ll Using immersion pumps
ll Sizes FLKS-1, FLKS-2, FLKS-3 and FLKS-4
with plastic tank housing
ll Energy-efficient thanks to optimized and adjusted drives and
the heat being released directly to the surroundings
ll Speed-controlled systems (optional):
The temperature of the operating fluid is controlled by adjusting
the fan speed with a set difference to the ambient temperature.
Function
The pump conveys the cooled operating fluid from the tank through the component
that is to be cooled. Once there, it absorbs the heat. It then flows back to the plate
heat exchanger, where it is returned to a cooler temperature by the cooling water.
Advantages
ll Cooling to below ambient temperatures also possible
(depending on temperature of the cooling fluid)
ll Using immersion pumps
ll Low release of heat to surroundings and low noise emission
ll Thermostatically or electronically controlled proportional valve available as
an option: the temperature of the operating fluid can thus be maintained at
a specific temperature value.
E 5.703.0/ 03.15
192
RFCS Compressor Coolers
Features
ll Fluid cooling system as separate auxiliary cooler or
for integration into a machine
ll Cooling capacities from 1 to 160 kW
ll Can be used for any cooling tasks
ll Stand-alone control of the system by means of innovative controller design
ll Condenser available as water-cooled or air-cooled variant
ll Several cooling circuits possible
ll Precise temperature control accuracies from 0.1 K
Function
The RFCS refrigerated fluid chiller system allows various fluids such as
water, water glycol and oil to be cooled. The chiller system consists of refrigerator,
pump, tank and controller and is able to set the temperature of the operating fluid
to a previously configured target value independently.
The energy-efficient, patented mixer principle, combined with a sealless submersible
pump, makes this system the ideal component for your machine tool.
Advantages
ll Target temperature can be set at or below ambient temperature
ll Leak-free immersion pump
ll Compact dimensions
ll User-friendly controller interface
ll Cleanable air filter
ll Plug & Play solution
ll Easy to service and user-friendly
Function
The HCC control cabinet cooler system is flexible in its installation and designed
to cool control cabinets. Special heat exchanger designs ensure energy-efficient
operation and a high level of operating reliability.
Regardless of the version used, whether air/air, air/water or refrigeration,
the HCC series ensures optimal conditions and improved service life for
electronic components.
Advantages
ll Compact design
ll Innovative heat exchanger designs
ll Optimal condensate separation
ll User-friendly controller interface
ll Plug & play solution
E 5.703.0/03.15
193
Note
The information in this brochure
relates to the operating conditions and
applications described.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications and
corrections.
194
Fluid-Air Cooling Systems
FLKS-1H
Application Field
ll Fluid-cooled drives:
Motor spindles, torque motors,
servomotors, linear motors
ll Inverter cooling
ll Gearbox cooling and lubrication
ll Bearing cooling
ll Tool cooling
E 5.818.0/03.15
195
Cooling Capacity
0.14
0.13
50/60Hz
0.12
0.11
P [kw/K]
0.10
0.09
0.08
0.07
0.06
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Q [l/min]
Cooling capacity tolerance: 5 %
Flow Rate
Electrical data:
TKY pump version
5.00 Permitted voltage range:
4.50 380 - 420 V 50 Hz 3 PH
400 - 480 V 60 Hz 3 PH
4.00
Voltage tolerance: +5 % / -10 %
3.50
2.50
Fan: 0.11 / 0.15 kW
2.00
1.50 60 Hz
1.00
50 Hz
0.50
0.00
0 1 2 3 4 5 6 7 8 9 10
Q [l/min]
Operating range: 2 10 l/min
Electrical data:
MTA50 pump version
1.10 Permitted voltage range:
1.05 380 - 415 V 50 Hz 3 PH
380 - 480 V 60 Hz 3 PH
1.00
60 Hz Voltage tolerance: +5 % / -10 %
0.95
0.85
Fan: 0.11 / 0.15 kW
0.80
0.75
50 Hz
0.70
0.65
0.60
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Q [l/min]
Operating range: 2 15 l/min
Flow rate tolerance: 9 %, pumping head tolerance: 7 % as per DIN EN ISO 9906 Cl. 2, App. A
Note:
E 5.818.0/ 03.15
The operating point of the pump (flow rate) depends on the characteristic curve (line sizes, line lengths, screwing elements).
In general, the fewer the system losses, the greater the flow rate and the greater the cooling capacity.
Please contact Technical Sales with questions on cooling capacity and flow rate data with other operating fluids,
as well as on special voltages or other pumps.
196
Electrical Connection
The motor is electrically connected
by the customer using a heavy-duty plug.
For example: housing 09300101541
and insert 09330102716 by Harting
Dimensions
[mm]
150 2
30 2
28.5 2 400 2 M8
P
+5
405
+5 min. +5 min.
457 100 281 150
Note:
E 5.818.0/03.15
We recommend maintaining the specified minimum distance to ensure unimpeded air entry and exit.
Anything below the minimum distance can affect cooling capacity and noise emissions.
197
Model Type
FLKS-1H-2.0-W-YA0-0-0
Model
FLKS = Fluid /Air Cooling System
Size
Type code
Operating fluid
W = Water-glycol (standard)
Pump
Y = Version with pump TKY
A = Version with pump MTA50
Other pumps on request.
Motor voltage
A = 380-420 V 50 Hz / 400-480 V 60 Hz, 3PH (pump TKY and MTA50)
See also electrical data.
Position pump connection
0 = Standard
Color
0 = none
(FLKS-1: white plastic tank housing)
Accessories
0 = no acessories (standard)
See table for corresponding accessory number.
Accessories
A Filling level and
60 C temperature switch
B Filling level switch
(2 switching points)
A/B D Flow switch
P
O Air filter
P Air deflection
Accessory number 0 1 44 30 14 36 43 59 82 122 124 105
See also Accessories for FLKS for more information.
D
O
FLKS-1H Standard
Part no. Designation Pump Version
3426850 FLKS-1H/2.0/W/YA0/0/0 TKY no accessories, fixed speed
3322575 FLKS-1H/2.0/W/AA0/0/0 MTA50 no accessories, fixed speed
E 5.818.0/ 03.15
198
Fluid-Air Cooling Systems
FLKS-1H PLUS
Application Field
ll Fluid-cooled drives:
Motor spindles, torque motors,
servomotors, linear motors
ll Inverter cooling
ll Gearbox cooling and lubrication
ll Bearing cooling
ll Tool cooling
E 5.818.0/03.15
199
Cooling Capacity
0.19
0.18
50/60Hz
0.17
0.16
0.15
P [kw/K]
0.14
0.13
0.12
0.11
0.10
0.09
0.08
0 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0
Q [l/min]
Cooling capacity tolerance: 5 %
Flow Rate
Electrical data:
601 pump version
5.00 Permitted voltage range:
380 - 420 V 50 Hz 3 PH
4.50 400 - 480 V 60 Hz 3 PH
Voltage tolerance: +5 % / -10 %
4.00
Motor output (50/60 Hz):
Pump: 0,50 / 0,70 kW
p [bar]
3.50
60 Hz Fan: 0,11 / 0,15 kW
3.00
2.50
50 Hz
2.00
0 5 10 15 20 25
Q [l/min]
Operating range: 5 25 l/min
Electrical data:
MTA50 pump version
1.10 Permitted voltage range:
1.05 380 - 415 V 50 Hz 3 PH
380 - 480 V 60 Hz 3 PH
1.00
Voltage tolerance: +5 % / -10 %
0.95
0.90
60 Hz Motor output (50/60 Hz):
Pump: 0,17 / 0,27 kW
p [bar]
0.85
Fan: 0,11 / 0,15 kW
0.80
0.75
0.70
50 Hz
0.65
0.60
0 5 10 15 20 25
Q [l/min]
Operating range: 2 15 l/min
Flow rate tolerance: 9 %, pumping head tolerance: 7 % as per DIN EN ISO 9906 Cl. 2, App. A
Note:
E 5.818.0/ 03.15
The operating point of the pump (flow rate) depends on the characteristic curve (line sizes, line lengths, screwing elements).
In general, the fewer the system losses, the greater the flow rate and the greater the cooling capacity.
Please contact Technical Sales with questions on cooling capacity and flow rate data with other operating fluids,
as well as on special voltages or other pumps.
200
Electrical Connection
The motor is electrically connected
by the customer using a heavy-duty plug.
For example: housing 09300101541
and insert 09330102716 by Harting
Dimensions
[mm]
150 2
30 2
M8
28,5 2 400 2
+5
433
+5 min. +5 min.
481 100 333 150
Note:
E 5.818.0/03.15
We recommend maintaining the specified minimum distance to ensure unimpeded air entry and exit.
Anything below the minimum distance can affect cooling capacity and noise emissions.
201
Model Type
FLKS-1H PLUS-2.4-W-601A2-0-0
Model
FLKS = Fluid /Air Cooling System
Size
Type code
Operating fluid
W = Water-glycol (standard)
Pump
601 = Version with pump 601
A = Version with pump MTA50
Other pumps on request.
Motor voltage
A = 380-420 V 50 Hz / 400-480 V 60 Hz, 3PH (pump 601 and MTA50)
See also electrical data.
Position pump connection
0 = Standard
2 = turned by 180
Color
0 = none
(FLKS-1: white plastic tank housing)
Accessories
0 = no acessories (standard)
See table for corresponding accessory number.
Accessories
A Filling level and
60 C temperature switch
B Filling level switch
(2 switching points)
A/B D Flow switch
P
O Air filter
P Air deflection
Accessory number 0 1 44 30 14 36 43 59 82 122 124 105
See also Accessories for FLKS for more information.
D
O
202
Fluid-Air Cooling Systems
FLKS-2S
Application Field
ll Fluid-cooled drives:
Motor spindles, torque motors,
servomotors, linear motors
ll Inverter cooling
ll Gearbox cooling and lubrication
ll Bearing cooling
ll Tool cooling
E 5.818.0/03.15
203
Cooling Capacity
0.35
0.33 60 Hz
0.31 50 Hz
0.29
0.27
P [kw/K]
0.25
0.23
0.21
0.19
0.17
0.15
0 5 10 15 20 25 30 35
Q [l/min]
Cooling capacity tolerance: 5 %
Flow Rate
Electrical data:
601 pump version
5.00 Permitted voltage range:
380 - 420 V 50 Hz 3 PH
4.50
400 - 480 V 60 Hz 3 PH
4.00 Voltage tolerance: +5 % / -10 %
3.00
60 Hz
Fan: 0.11 / 0.145 kW
2.50
2.00
50 Hz
1.50
1.00
0 5 10 15 20 25 30
Q [l/min]
Operating range: 5 25 l/min
Electrical data:
MTH 2-4 pump version
6.00 Permitted voltage range:
5.50 380 - 415 V 50 Hz 3 PH
380 - 440 V 60 Hz 3 PH
5.00
60 Hz Voltage tolerance: +5 % / -10 %
4.50
3.50
50 Hz Fan: 0.11 / 0.145 kW
3.00
2.50
2.00
1.50
1.00
0 5 10 15 20 25 30 35 40
Q [l/min]
Operating range: 10 40 l/min
Flow rate tolerance: 9 %, pumping head tolerance: 7 % as per DIN EN ISO 9906 Cl. 2, App. A
Note:
E 5.818.0/ 03.15
The operating point of the pump (flow rate) depends on the characteristic curve (line sizes, line lengths, screwing elements).
In general, the fewer the system losses, the greater the flow rate and the greater the cooling capacity.
Please contact Technical Sales with questions on cooling capacity and flow rate data with other operating fluids,
as well as on special voltages or other pumps.
204
Electrical Connection
The motor is electrically connected
by the customer using a heavy-duty plug.
For example: housing 09300101541
and insert 09330102716 by Harting
Dimensions
[mm]
200 2
110 2 400 2
25 2
M8
+5
max. 320
P
+5
max. 525
+5 min. +5 min.
625 130 311 200
Note:
E 5.818.0/03.15
We recommend maintaining the specified minimum distance to ensure unimpeded air entry and exit.
Anything below the minimum distance can affect cooling capacity and noise emissions.
205
Model Type
FLKS-2S-1.0-W-601A0-0-0
Model
FLKS = Fluid /Air Cooling System
Size
Type code
Operating fluid
W = Water-glycol (standard)
Pump
601 = Version with pump 601
H2-4 = Version with pump MTH2-4
Other pumps on request.
Motor voltage
A = 380-420 V 50 Hz / 400-480 V 60 Hz, 3PH (pump 601)
B = 380-415 V 50 Hz / 380-440 V 60 Hz, 3PH (pump MTH2-4)
See also electrical data.
Position pump connection
0 = Standard
Color
0 = none
(FLKS-2: white plastic tank housing)
Accessories
0 = no acessories (standard)
See table for corresponding accessory number.
Accessories
A Filling level and
60 C temperature switch
B Filling level switch
(2 switching points)
A/B D Flow switch
P
O Air filter
P Air deflection
Accessory number 0 1 44 30 14 36 43 59 82 122 124 105
See also Accessories for FLKS for more information.
D
O
FLKS-2S Standard
Part no. Designation Pump Version
3811499 FLKS-2S/1.0/W/601A0/0/0 601 no accessories, fixed speed
3905239 FLKS-2S/1.0/W/H2-4B0/0/0 MTH2-4 no accessories, fixed speed
E 5.818.0/ 03.15
206
Fluid-Air Cooling Systems
FLKS-2EC
with speed control
Application Field
ll Fluid-cooled drives:
Motor spindles, torque motors,
servomotors, linear motors
ll Inverter cooling
ll Gearbox cooling and lubrication
ll Bearing cooling
ll Tool cooling
E 5.818.0/03.15
207
Open-Loop Speed Control
The temperature sensor of the FLKS-2EC5 measures the water-glycol outlet
temperature from the cooling system. The 0 10 V analog signal of the sensor
is assigned a temperature range of +25 up to +45 C. The signal is forwarded to
the EC fan according to the measured fluid outlet temperature to control the speed.
The fan switches on at 1.5 V (= +28 C) and reaches its maximum speed at 10 V
(= +45 C).
Even at low ambient temperatures, the fluid temperature cannot drop below
+28 C given constant power input. This prevents condensation on electrical
components.
Application:
Specially suited for low air temperatures, e. g., outdoors
Application:
Primarily precision cooling (e. g., in machine tools)
208
Cooling Capacity
0.36
0.34
1,600 1/min
0.32
0.26
0.20
800 1/min
0.18
0.16
0.14
0 5 10 15 20 25 30 35
Q [l/min]
Cooling capacity tolerance: 5 %
Flow Rate
Electrical data:
601 pump version
5.00 Permitted voltage range:
4.50 Pump:
380 - 420 V 50 Hz 3 PH
4.00
400 - 480 V 60 Hz 3 PH
3.50 Voltage tolerance: + 5 % / -10 %
p [bar]
3.00
60 Hz Fan:
200 - 240 V 50/60 Hz 1 PH
2.50 Voltage tolerance: 10 %
2.00
50 Hz Motor output (50/60 Hz):
1.50 Pump: 0.50 / 0.70 kW
Fan: 0.14 kW
1.00
0 5 10 15 20 25 30
Q [l/min]
Operating range: 5 30 l/min
Electrical data:
MTH 2-4 pump version
6.00 Permitted voltage range:
5.50
Pump:
5.00 380 - 415 V 50 Hz 3 PH
60 Hz
4.50 380 - 440 V 60 Hz 3 PH
Voltage tolerance: + 5 % / -10 %
4.00
p [bar]
3.50 Fan:
50 Hz 200 - 240 V 50/60 Hz 1 PH
3.00
Voltage tolerance: 10 %
2.50
Note:
E 5.818.0/03.15
The operating point of the pump (flow rate) depends on the characteristic curve (line sizes, line lengths, screwing elements).
In general, the fewer the system losses, the greater the flow rate and the greater the cooling capacity.
Please contact Technical Sales with questions on cooling capacity and flow rate data with other operating fluids,
as well as on special voltages or other pumps.
209
Electrical Connection
The motor is electrically connected
by the customer using a heavy-duty
plug.
Additional 24 V DC control voltage,
more information available upon request.
Dimensions
[mm]
200 2
110 2 400 2
25 2
M8
+5
max. 320
P
+5
max. 525
+5 min. +5 min.
625 130 311 200
Note:
We recommend maintaining the specified minimum distance to ensure unimpeded air entry and exit.
Anything below the minimum distance can affect cooling capacity and noise emissions.
E 5.818.0/ 03.15
210
Model Type
FLKS-2-EC3-1.0-W-601A0-0-0
Model
FLKS = Fluid /Air Cooling System
Size
Open-loop / closed-loop speed control
EC3 = Closed-loop speed control (with PID controller)
EC5 = Open-loop speed control (with temperature sensor)
Type code
Operating fluid
W = Water-glycol (standard)
Pump
601 = Version with pump 601
H2-4 = Version with pump MTH2-4
Other pumps on request.
Motor voltage
A = 380-420 V 50 Hz / 400-480 V 60 Hz, 3PH (pump 601)
200 240 V 50/60 Hz, 1PH (fan)
B = 380-415 V 50 Hz / 380-440 V 60 Hz, 3PH (pump MTH2-4)
200 240 V 50/60 Hz, 1PH (fan)
See also electrical data.
Position pump connection
0 = Standard
Color
0 = none
(FLKS-2: white plastic tank housing)
Accessories
0 = no accessories (standard)
See table for corresponding accessory number.
E 5.818.0/03.15
211
Accessories
A Filling level and
60 C temperature switch
B Filling level switch
(2 switching points)
A/B D Flow switch
P
O Air filter
P Air deflection
Accessory number 0 1 44 30 14 36 43 59 82 122 124 105
See also Accessories for FLKS for more information.
D
O
FLKS-2EC Standard
Part no. Designation Pump Version
3900715 FLKS-2EC3/1.0/W/601A0/0/0 601 no accessories, closed-loop speed control
3951357 FLKS-2EC3/1.0/W/H2-4B0/0/0 MTH2-4 no accessories, closed-loop speed control
E 5.818.0/ 03.15
212
Fluid-Air Cooling Systems
FLKS-3S
Application Field
ll Fluid-cooled drives:
Motor spindles, torque motors,
servomotors, linear motors
ll Inverter cooling
ll Gearbox cooling and lubrication
ll Bearing cooling
ll Tool cooling
E 5.818.0/03.15
213
Cooling Capacity
0.55
0.50
60 Hz
0.45 50 Hz
0.40
P [kw/K]
0.35
0.30
0.25
0.20
0.15
0 10 15 20 25 30 35 40 45 50 55 60
Q [l/min]
Cooling capacity tolerance: 5 %
Flow Rate
Electrical data:
601 pump version
5.00 Permitted voltage range:
380 - 420 V 50 Hz 3 PH
4.50
400 - 480 V 60 Hz 3 PH
4.00 Voltage tolerance: +5 % / -10 %
3.00
60 Hz
Fan: 0.17 / 0.23 kW
2.50
2.00
50 Hz
1.50
1.00
0 5 10 15 20 25 30
Q [l/min]
Operating range: 5 30 l/min
Electrical data:
MTH 2-4 pump version
6.00 Permitted voltage range:
5.50 380 - 415 V 50 Hz 3 PH
380 - 440 V 60 Hz 3 PH
5.00
60 Hz Voltage tolerance: +5 % / -10 %
4.50
3.50
50 Hz Fan: 0.17 / 0.23 kW
3.00
2.50
2.00
1.50
1.00
0 5 10 15 20 25 30 35 40
Q [l/min]
Operating range: 530 l/min
Flow rate tolerance: 9 %, pumping head tolerance: 7 % as per DIN EN ISO 9906 Cl. 2, App. A
Note:
E 5.818.0/ 03.15
The operating point of the pump (flow rate) depends on the characteristic curve (line sizes, line lengths, screwing elements).
In general, the fewer the system losses, the greater the flow rate and the greater the cooling capacity.
Please contact Technical Sales with questions on cooling capacity and flow rate data with other operating fluids,
as well as on special voltages or other pumps.
214
Electrical Connection
The motor is electrically connected
by the customer using a heavy-duty plug.
For example: housing 09300101541
and insert 09330102716 by Harting
Dimensions
[mm]
K
230 2
93 2
100 2 300 3 M8 +5
max. 463
+5
708
+5 min. +5 min.
500 110 443 250
Note:
E 5.818.0/03.15
We recommend maintaining the specified minimum distance to ensure unimpeded air entry and exit.
Anything below the minimum distance can affect cooling capacity and noise emissions.
215
Model Type
FLKS-3S-3.0-W-601A0-0-0
Model
FLKS = Fluid /Air Cooling System
Size
Type code
Operating fluid
W = Water-glycol (standard)
Pump
601 = Version with pump 601
H2-4 = Version with pump MTH2-4
Other pumps on request.
Motor voltage
A = 380-420 V 50 Hz / 400-480 V 60 Hz, 3PH (pump 601)
B = 380-415 V 50 Hz / 380-440 V 60 Hz, 3PH (pump MTH2-4)
See also electrical data.
Position pump connection
0 = standard
Color
0 = none
(FLKS-3: white plastic tank housing)
Accessories
0 = no accessories (standard)
See table for corresponding accessory number.
Accessories
A Filling level and
60 C temperature switch
B Filling level switch
(2 switching points)
P D Flow switch
O
O Air filter
P Air deflection
Accessory number 0 1 44 30 14 36 43 59 82 122 124 105
See also Accessories for FLKS for more information.
D
A/B
FLKS-3S Standard
Part no. Designation Pump Version
3991017 FLKS-3S/3.0/W/601A0/0/0 601 no accessories, fixed speed
3991211 FLKS-3S/3.0/W/H2-4B0/0/0 MTH2-4 no accessories, fixed speed
E 5.818.0/ 03.15
216
Fluid-Air Cooling Systems
FLKS-3EC
with speed control
Application Field
ll Fluid-cooled drives:
Motor spindles, torque motors,
servomotors, linear motors
ll Inverter cooling
ll Gearbox cooling and lubrication
ll Bearing cooling
ll Tool cooling
E 5.818.0/03.15
217
Open-Loop Speed Control
The temperature sensor of the FLKS-3EC5 measures the water-glycol outlet
temperature from the cooling system. The 0 10 V analog signal of the sensor
is assigned a temperature range of +25 up to +45 C. The signal is forwarded to
the EC fan according to the measured fluid outlet temperature to control the speed.
The fan switches on at 1.5 V (= + 28 C) and reaches its maximum speed at 10 V
(= +45 C).
Even at low ambient temperatures, the fluid temperature cannot drop below
+28 C given constant power input. This prevents condensation on electrical
components.
Application:
Specially suited for low air temperatures, e. g., outdoors
Application:
Primarily precision cooling (e. g., in machine tools)
218
Cooling Capacity
0.55
0.50
1,520 1/min
0.45
1,200 1/min
0.40
1,000 1/min
P [kw/K]
0.35
800 1/min
0.30
0.25
0.20
0.15
0 10 15 20 25 30 35 40 45 50 55 60
Q [l/min]
Cooling capacity tolerance: 5 %
Flow Rate
Electrical data:
601 pump version
5.00 Permitted voltage range:
4.50 Pump:
380 - 420 V 50 Hz 3 PH
4.00
400 - 480 V 60 Hz 3 PH
3.50 Voltage tolerance: +5 % / -10 %
p [bar]
3.00
60 Hz Fan:
200 - 240 V 50/60 Hz 1 PH
2.50 Voltage tolerance: 10 %
2.00
50 Hz Motor output (50/60 Hz):
1.50 Pump: 0.50 / 0.70 kW
Fan: 0.165 kW
1.00
0 5 10 15 20 25 30
Q [l/min]
Operating range: 5 30 l/min
Electrical data:
MTH 2-4 pump version
6.00 Permitted voltage range:
5.50
Pump:
5.00 380 - 415 V 50 Hz 3 PH
60 Hz
4.50 380 - 440 V 60 Hz 3 PH
Voltage tolerance: +5 % / -10 %
4.00
p [bar]
3.50 Fan:
50 Hz 200 - 240 V 50/60 Hz 1 PH
3.00
Voltage tolerance: 10 %
2.50
Note:
E 5.818.0/03.15
The operating point of the pump (flow rate) depends on the characteristic curve (line sizes, line lengths, screwing elements).
In general, the fewer the system losses, the greater the flow rate and the greater the cooling capacity.
Please contact Technical Sales with questions on cooling capacity and flow rate data with other operating fluids,
as well as on special voltages or other pumps.
219
Electrical Connection
The motor is electrically connected
by the customer using a heavy-duty
plug.
Additional 24 V DC control voltage,
more information available upon request.
Dimensions
[mm]
K
230 2
93 2
100 2 300 3 M8 +5
max. 463
+5
708
+5 min. +5 min.
500 110 443 250
Note:
We recommend maintaining the specified minimum distance to ensure unimpeded air entry and exit.
Anything below the minimum distance can affect cooling capacity and noise emissions.
E 5.818.0/ 03.15
220
Model Type
FLKS-3-EC3-3.0-W-601A0-0-0
Model
FLKS = Fluid /Air Cooling System
Size
Open-loop / closed-loop speed control
EC3 = Closed-loop speed control (with PID controller)
EC5 = Open-loop speed control (with temperature sensor)
Type code
Operating fluid
W = Water-glycol (standard)
Pump
601 = Version with pump 601
H2-4 = Version with pump MTH2-4
Other pumps on request.
Motor voltage
A = 380-420 V 50 Hz / 400-480 V 60 Hz, 3PH (pump 601)
200 240 V 50/60 Hz, 1PH (fan)
B = 380-415 V 50 Hz / 380-440 V 60 Hz, 3PH (pump MTH2-4)
200 240 V 50/60 Hz, 1PH (fan)
See also electrical data.
Position pump connection
0 = standard
Color
0 = none
(FLKS-3: white plastic tank housing)
Accessories
0 = no accessories (standard)
See table for corresponding accessory number.
E 5.818.0/03.15
221
Accessories
A Filling level and
60 C temperature switch
B Filling level switch
(2 switching points)
P D Flow switch
O
O Air filter
P Air deflection
Accessory number 0 1 44 30 14 36 43 59 82 122 124 105
See also Accessories for FLKS for more information.
D
A/B
FLKS-3EC Standard
Part no. Designation Pump Version
3980425 FLKS-3EC3/3.0/W/601A0/0/0 601 no accessories, closed-loop speed control
4009719 FLKS-3EC3/3.0/W/H2-4B0/0/0 MTH2-4 no accessories, closed-loop speed control
E 5.818.0/ 03.15
222
Fluid-Air Cooling Systems
FLKS-4S
Application Field
ll Fluid-cooled drives:
Motor spindles, torque motors,
servomotors, linear motors
ll Inverter cooling
ll Gearbox cooling and lubrication
ll Bearing cooling
ll Tool cooling
E 5.818.0/03.15
223
Cooling Capacity
0.75
0.70 60 Hz
0.65
50 Hz
0.60
P [kw/K]
0.55
0.50
0.45
0.40
0.35
10 15 20 25 30 35 40 45 50
Q [l/min]
Cooling capacity tolerance: 5 %
Flow Rate
Electrical data:
601 pump version
5.00 Permitted voltage range:
380 - 420 V 50 Hz 3 PH
4.50
400 - 480 V 60 Hz 3 PH
4.00 Voltage tolerance: +5 % / -10 %
3.00
60 Hz
Fan: 0.45 / 0.70 kW
2.50
2.00
50 Hz
1.50
1.00
0 5 10 15 20 25 30
Q [l/min]
Operating range: 5 30 l/min
Electrical data:
MTH 2-6 pump version
9.00 Permitted voltage range:
8.50 380 - 415 V 50 Hz 3 PH
8.00 380 - 440 V 60 Hz 3 PH
7.50 Voltage tolerance: +5 % / -10 %
7.00
6.50
Motor output (50/60 Hz):
6.00 60 Hz
Pump: 0.845 / 1.28 kW
p [bar]
5.50
Fan: 0.45 / 0.70 kW
5.00
4.50
4.00
3.50 50 Hz
3.00
2.50
2.00
0 5 10 15 20 25 30 35 40 45 50 55
Q [l/min]
Operating range: 15 55 l/min
Flow rate tolerance: 9 %, pumping head tolerance: 7 % as per DIN EN ISO 9906 Cl. 2, App. A
Note:
E 5.818.0/ 03.15
The operating point of the pump (flow rate) depends on the characteristic curve (line sizes, line lengths, screwing elements).
In general, the fewer the system losses, the greater the flow rate and the greater the cooling capacity.
Please contact Technical Sales with questions on cooling capacity and flow rate data with other operating fluids,
as well as on special voltages or other pumps.
224
Electrical Connection
The motor is electrically connected
by the customer using a heavy-duty plug.
For example: housing 09300101541
and insert 09330102716 by Harting
Dimensions
[mm]
K
230 2
126 2
M8
25 2 520 3 +5
max. 483
+5
813
+5 min. +5 min.
570 110 463 300
Note:
E 5.818.0/03.15
We recommend maintaining the specified minimum distance to ensure unimpeded air entry and exit.
Anything below the minimum distance can affect cooling capacity and noise emissions.
225
Model Type
FLKS-4S-2.0-W-601A0-0-0
Model
FLKS = Fluid /Air Cooling System
Size
Type code
Operating fluid
W = Water-glycol (standard)
Pump
601 = Version with pump 601
H2-6 = Version with pump MTH2-6
Other pumps on request.
Motor voltage
A = 380-420 V 50 Hz / 400-480 V 60 Hz, 3PH (pump 601)
B = 380-415 V 50 Hz / 380-440 V 60 Hz, 3PH (pump MTH2-6)
Other pumps on request.
Position pump connection
0 = standard
Color
0 = none
(FLKS-4: white plastic tank housing)
Accessories
0 = no accessories (standard)
See table for corresponding accessory number.
Accessories
A Filling level and
60 C temperature switch
B Filling level switch
(2 switching points)
P D Flow switch
O
O Air filter
P Air deflection
Accessory number 0 1 44 30 14 36 43 59 82 122 124 105
See also Accessories for FLKS for more information.
D
A/B
FLKS-4S Standard
Part no. Designation Pump Version
3951597 FLKS-4S/2.0/W/601A0/0/0 601 no accessories, fixed speed
3932404 FLKS-4S/2.0/W/H2-6B0/0/0 MTH2-6 no accessories, fixed speed
E 5.818.0/ 03.15
226
Fluid-Air Cooling Systems
FLKS-4EC
with speed control
Application Field
ll Fluid-cooled drives:
Motor spindles, torque motors,
servomotors, linear motors
ll Inverter cooling
ll Gearbox cooling and lubrication
ll Bearing cooling
ll Tool cooling
E 5.818.0/03.15
227
Open-Loop Speed Control
The temperature sensor of the FLKS-4EC5 measures the water-glycol outlet
temperature from the cooling system. The 0 10 V analog signal of the sensor
is assigned a temperature range of + 25 up to +45 C. The signal is forwarded
to the EC fan according to the measured fluid outlet temperature to control the speed.
The fan switches on at 1.5 V (= +28 C) and reaches its maximum speed
at 10 V (= +45 C).
Even at low ambient temperatures, the fluid temperature cannot drop below +28 C
given constant power input. This prevents condensation on electrical components.
Application:
Specially suited for low air temperatures, e. g., outdoors
Application:
Primarily precision cooling (e. g., in machine tools)
228
Cooling Capacity
0.70
1,460 1/min
0.65
0.55
P [kw/K]
1,000 1/min
0.50
0.40
0.35
0.30
10 15 20 25 30 35 40 45 50
Q [l/min]
Cooling capacity tolerance: 5 %
Flow Rate
Electrical data:
601 pump version
5.00 Permitted voltage range:
380 - 420 V 50 Hz 3 PH
4.50
400 - 480 V 60 Hz 3 PH
4.00 Voltage tolerance: +5 % / -10 %
3.00
60 Hz
Fan: 0.53 kW
2.50
2.00
50 Hz
1.50
1.00
0 5 10 15 20 25 30
Q [l/min]
Operating range: 5 30 l/min
Electrical data:
MTH 2-6 pump version
9.00 Permitted voltage range:
8.50 380 - 415 V 50 Hz 3 PH
8.00 380 - 440 V 60 Hz 3 PH
7.50 Voltage tolerance: +5 % / -10 %
7.00
6.50
Motor output (50/60 Hz):
6.00 60 Hz
Pump: 0.845 / 1.28 kW
p [bar]
5.50
Fan: 0.53 kW
5.00
4.50
4.00
3.50 50 Hz
3.00
2.50
2.00
0 5 10 15 20 25 30 35 40 45 50 55
Q [l/min]
Operating range: 15 55 l/min
Flow rate tolerance: 9 %, pumping head tolerance: 7 % as per DIN EN ISO 9906 Cl. 2, App. A
E 5.818.0/03.15
Note:
The operating point of the pump (flow rate) depends on the characteristic curve (line sizes, line lengths, screwing elements).
In general, the fewer the system losses, the greater the flow rate and the greater the cooling capacity.
229
Electrical Connection
The motor is electrically connected
by the customer using a heavy-duty
plug.
Additional 24 V DC control voltage,
more information available upon request.
Dimensions
[mm]
K
230 2
126 2
M8
25 2 520 3 +5
max. 483
+5
813
+5 min. +5 min.
570 110 463 300
Note:
We recommend maintaining the specified minimum distance to ensure unimpeded air entry and exit.
Anything below the minimum distance can affect cooling capacity and noise emissions.
E 5.818.0/ 03.15
230
Model Type
FLKS-4-EC3-2.0-W-601A0-0-0
Model
FLKS = Fluid /Air Cooling System
Size
Open-loop / closed-loop speed control
EC3 = Closed-loop speed control (with PID controller)
EC5 = Open-loop speed control (with temperature sensor)
Type code
Operating fluid
W = Water-glycol (standard)
Pump
601 = Version with pump 601
H2-6 = Version with pump MTH 2-6
Other pumps on request.
Motor voltage
A = 380-420 V 50 Hz / 400-480 V 60 Hz, 3PH (pump 601)
B = 380-415 V 50 Hz / 380-440 V 60 Hz, 3PH (pump MTH2-6)
See also electrical data.
Position pump connection
0 = standard
Color
0 = none
(FLKS-4: white plastic tank housing)
Accessories
0 = no accessories (standard)
See table for corresponding accessory number.
E 5.818.0/03.15
231
Accessories
A Filling level and
60 C temperature switch
B Filling level switch
(2 switching points)
P D Flow switch
O
O Air filter
P Air deflection
Accessory number 0 1 44 30 14 36 43 59 82 122 124 105
See also Accessories for FLKS for more information.
D
A/B
FLKS-4EC Standard
Part no. Designation Pump Version
3902038 FLKS-4EC3/2.0/W/601A0/0/0 601 no accessories, closed-loop speed control
3901788 FLKS-4EC3/2.0/W/H2-6B0/0/0 MTH2-6 no accessories, closed-loop speed control
E 5.818.0/ 03.15
232
Fluid-Air Cooling Systems
FLKS-5S
Application Field
ll Fluid-cooled drives:
Motor spindles, torque motors,
servomotors, linear motors
ll Inverter cooling
ll Gearbox cooling and lubrication
ll Bearing cooling
ll Tool cooling
E 5.818.0/03.15
233
Cooling Capacity
0.80
0.75 60 Hz
0.70 50 Hz
0.65
0.60
P [kw/K]
0.55
0.50
0.45
0.40
0.35
10 20 30 40 50 60 70
Q [l/min]
Cooling capacity tolerance: 5 %
Flow Rate
Electrical Data:
601 pump version
5.00 Permitted voltage range:
380 - 415 V 50 Hz 3 PH
4.50
380 - 440 V 60 Hz 3 PH
4.00 Voltage tolerance: +5 % / -10 %
3.00
60 Hz
Pump MTH 2-6: 0.845 / 1.28 kW
2.50 Fan: 0.45 / 0.70 kW
1.00
0 5 10 15 20 25 30
Q [l/min]
Operating range: 5 30 l/min
5.50
5.00
4.50
4.00
3.50 50 Hz
3.00
2.50
2.00
0 5 10 15 20 25 30 35 40 45 50 55
Q [l/min]
Operating range: 15 55 l/min
Flow rate tolerance: 9 %, pumping head tolerance: 7 % as per DIN EN ISO 9906 Cl. 2, App. A
Note:
E 5.818.0/ 03.15
The operating point of the pump (flow rate) depends on the characteristic curve (line sizes, line lengths, screwing elements).
In general, the fewer the system losses, the greater the flow rate and the greater the cooling capacity.
Please contact Technical Sales with questions on cooling capacity and flow rate data with other operating fluids,
as well as on special voltages or other pumps.
234
Electrical Connection
The motor is electrically connected
by the customer using a heavy-duty plug.
For example: housing 09300101541
and insert 09330102716 by Harting
Dimensions
[mm]
K
123 5
380 2
21
11
640 2 min. +5 min.
110 595 350
+5
950
+5
670 5 647
Note:
E 5.818.0/03.15
We recommend maintaining the specified minimum distance to ensure unimpeded air entry and exit.
Anything below the minimum distance can affect cooling capacity and noise emissions.
235
Model Type
FLKS-5S-2.0-W-H2-6B0+601B0-2-0
Model
FLKS = Fluid /Air Cooling System
Size
Type code
Operating fluid
W = Water-glycol (standard)
Pump
Version with 2 pumps:
H2-6 = Pump MTH2-6
601 = Pump 601
Version with only one pump on request.
Motor voltage
B = 380-415 V 50 Hz / 380-440 V 60 Hz, 3PH (pump MTH2-6 + pump 601)
See also electrical data
Position pump connection
0 = Standard
Color
2 = light grey RAL 7035
Accessories
0 = no accessories (Standard)
See table for corresponding accessory number.
Accessories
A Filling level and 60 C temperature switch
B Filling level switch (2 switching points)
D Flow switch
O Air filter
O Accessory number 0 1 44 30 14 59 122 105
See also Accessories for FLKS for more information.
A/B
FLKS-5S Standard
Part no. Designation Pump Version
3953543 FLKS-5S/2.0/W/H2-6B0+601B0/2/0 MTH2-6 + 601 no accessories, fixed speed
3956364 FLKS-5S/2.0/W/H4-6B0/2/0 MTH4-6 no accessories, fixed speed
E 5.818.0/ 03.15
236
Fluid-Air Cooling Systems
FLKS-5EC
with speed control
Application Field
ll Fluid-cooled drives:
Motor spindles, torque motors,
servomotors, linear motors
ll Inverter cooling
ll Gearbox cooling and lubrication
ll Bearing cooling
ll Tool cooling
E 5.818.0/03.15
237
Open-Loop Speed Control
The temperature sensor of the FLKS-5EC5 measures the water-glycol outlet
temperature from the cooling system. The 0 10 V analog signal of the sensor
is assigned a temperature range of +25 up to + 45 C. The signal is forwarded
to the EC fan according to the measured fluid outlet temperature to control the speed.
The fan switches on at 1.5 V (= +28 C) and reaches its maximum speed at 10 V
(= +45 C).
Even at low ambient temperatures, the fluid temperature cannot drop below +28 C
given constant power input. This prevents condensation on electrical components.
Application:
Specially suited for low air temperatures, e.g., outdoors
Application:
Primarily precision cooling (e.g., in machine tools)
238
Cooling Capacity
0.85
0.80 1,460 1/min
0.75
1,200 1/min
0.70
0.65
0.60
1,000 1/min
P [kw/K]
0.55
0.50 800 1/min
0.45
0.40
0.35
0.30
0.25
10 20 30 40 50 60 70
Q [l/min]
Cooling capacity tolerance: 5 %
Flow Rate
Electrical data:
601 pump version
5.00 Permitted voltage range:
380 - 415 V 50 Hz 3 PH
4.50
380 - 440 V 60 Hz 3 PH
4.00 Spannungstoleranz +5 % / -10 %
3.00
60 Hz
Pump MTH 2-6: 0.845 / 1.28 kW
2.50 Fan: 0.53 kW
1.00
0 5 10 15 20 25 30
Q [l/min]
Operating range: 5 30 l/min
5.50
5.00
4.50
4.00
3.50 50 Hz
3.00
2.50
2.00
0 5 10 15 20 25 30 35 40 45 50 55
Q [l/min]
Operating range: 15 55 l/min
Flow rate tolerance: 9 %, pumping head tolerance: 7 % as per DIN EN ISO 9906 Cl. 2, App. A
Note:
E 5.818.0/03.15
The operating point of the pump (flow rate) depends on the characteristic curve (line sizes, line lengths, screwing elements).
In general, the fewer the system losses, the greater the flow rate and the greater the cooling capacity.
Please contact Technical Sales with questions on cooling capacity and flow rate data with other operating fluids,
as well as on special voltages or other pumps.
239
Electrical Connection
The motor is electrically connected
by the customer using a heavy-duty
plug.
Additional 24 V DC control voltage,
more information available upon request.
Dimensions
[mm]
K
123 5
380 2
21
11
640 2 min. +5 min.
110 595 350
+5
950
+5
670 5 647
Note:
We recommend maintaining the specified minimum distance to ensure unimpeded air entry and exit.
Anything below the minimum distance can affect cooling capacity and noise emissions.
E 5.818.0/ 03.15
240
Model Type
FLKS-5-EC3-2.0-W-H2-6B0+601B0-2-0
Model
FLKS = Fluid /Air Cooling System
Size
Open-loop / closed-loop speed control
EC3 = Closed-loop speed control (with PID controller)
EC5 = Open-loop speed control (with temperature sensor)
Type code
Operating fluid
W = Water-glycol (standard)
Pump
Version with 2 pumps:
H2- 6 = pump MTH2-6
601 = pump 601
Version with only one pump on request.
Position pump connection
B = 380-415 V 50 Hz / 380-440 V 60 Hz, 3PH (pump MTH2-6 + pump 601)
See also electrical data.
Position pump connection
0 = standard
Color
2 = light grey RAL 7035
Accessories
0 = no accessories (standard)
See table for corresponding accessory number.
E 5.818.0/03.15
241
Accessories
A Filling level and 60 C temperature switch
B Filling level switch (2 switching points)
D Flow switch
O Air filter
O Accessory number 0 1 44 30 14 59 122 105
See also Accessories for FLKS for more information.
A/B
FLKS-5EC Standard
Part no. Designation Pump Version
3956717 FLKS-5EC3/2.0/W/H2-6B0+601B0/2/0 MTH2-6 + 601 no accessories, closed-loop speed control
3956722 FLKS-5EC3/2.0/W/H4-6B0/2/0 MTH4-6 no accessories, closed-loop speed control
E 5.818.0/ 03.15
242
Fluid-Air Cooling Systems
FLKS-6S
Application Field
ll Fluid-cooled drives:
Motor spindles, torque motors,
servomotors, linear motors
ll Inverter cooling
ll Gearbox cooling and lubrication
ll Bearing cooling
ll Tool cooling
E 5.818.0/03.15
243
Cooling Capacity
0.13
1.20
60 Hz
1.10
50 Hz
1.00
P [kw/K]
0.90
0.80
0.70
0.60
0.50
0.40
10 20 30 40 50 60 70 80 90 100
Q [l/min]
Cooling capacity tolerance: 5 %
Flow Rate
Electrical data:
MTH 4-4 pump version
6.00 Permitted voltage range:
5.50 380 - 415 V 50 Hz 3 PH
5.00 380 - 440 V 60 Hz 3 PH
4.50 60 Hz Voltage tolerance: +5 % / -10 %
4.00
Motor output (50/60 Hz):
3.50
Pump: 0.96 / 1.51 kW
p [bar]
3.00 50 Hz
Fan: 0.69 / 1.05 kW
2.50
2.00
1.50
1.00
0.50
0.00
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
Q [l/min]
Operating range: 10 70 l/min
Electrical data:
MTH 4-6 pump version
6.00 Permitted voltage range:
5.50 380 - 415 V 50 Hz 3 PH
5.00 Voltage tolerance: +5 % / -10 %
4.50
4.00 Motor output (50 Hz):
Pump: 1.34 kW
3.50 50 Hz Fan: 0.69 kW
p [bar]
3.00
2.50
2.00
1.50
1.00
0.50
0.00
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
Q [l/min]
Operating range: 30 100 l/min
Flow rate tolerance: 9 %, pumping head tolerance: 7 % as per DIN EN ISO 9906 Cl. 2, App. A
Note:
E 5.818.0/ 03.15
The operating point of the pump (flow rate) depends on the characteristic curve (line sizes, line lengths, screwing elements).
In general, the fewer the system losses, the greater the flow rate and the greater the cooling capacity.
Please contact Technical Sales with questions on cooling capacity and flow rate data with other operating fluids,
as well as on special voltages or other pumps.
244
Electrical Connection
The motor is electrically connected
by the customer using a heavy-duty plug.
For example: housing 09300101541
and insert 09330102716 by Harting
Dimensions
[mm]
K
123 5
380 2
21
11
min. +5 min.
640 2 110 595 400
+5
1,038
+5
670 5 650
Note:
E 5.818.0/03.15
We recommend maintaining the specified minimum distance to ensure unimpeded air entry and exit.
Anything below the minimum distance can affect cooling capacity and noise emissions.
245
Model Type
FLKS-6S-2.0-W-H4-4B0-2-0
Model
FLKS = Fluid /Air Cooling System
Size
Type code
Operating fluid
W = Water-glycol (standard)
Pump
H4-4 = Version with pump MTH4-4
H4-6 = Version with pump MTH4-6
Other pumps on request.
Motor voltage
B = 380-415 V 50 Hz / 380-440 V 60 Hz, 3PH (pump MTH4-4)
C = 380-415 V 50 Hz, 3PH (pump MTH4-6)
See also electrical data.
Position pump connection
0 = standard
Color
2 = light grey RAL 7035
Accessories
0 = no accessories (standard)
See table for corresponding accessory number.
Accessories
A Filling level and 60 C temperature switch
B Filling level switch (2 switching points)
D Flow switch
O Air filter
O Accessory number 0 1 44 30 14 59 122 105
See also Accessories for FLKS for more information.
A/B
FLKS-6S Standard
Part no. Designation Pump Version
3952152 FLKS-6S/2.0/W/H4-4B0/2/0 MTH4-4 no accessories, fixed speed
3952766 FLKS-6S/2.0/W/H4-6C0/2/0 MTH4-6 no accessories, fixed speed
E 5.818.0/ 03.15
246
Fluid-Air Cooling Systems
FLKS-6EC
with speed control
Application Field
ll Fluid-cooled drives:
Motor spindles, torque motors,
servomotors, linear motors
ll Inverter cooling
ll Gearbox cooling and lubrication
ll Bearing cooling
ll Tool cooling
E 5.818.0/03.15
247
Open-Loop Speed Control
The temperature sensor of the FLKS-6EC5 measures the water-glycol outlet
temperature from the cooling system. The 0 10 V analog signal of the sensor
is assigned a temperature range of +25 up to +45 C. The signal is forwarded
to the EC fan according to the measured fluid outlet temperature to control the speed.
The fan switches on at 1.5 V (= +28 C) and reaches its maximum speed at 10 V
(= +45 C).
Even at low ambient temperatures, the fluid temperature cannot drop below +28 C
given constant power input. This prevents condensation on electrical components.
Application:
Specially suited for low air temperatures, e. g., outdoors
Application:
Primarily precision cooling (e. g., in machine tools)
248
Cooling Capacity
1.30
1.20
1,600 1/min
1,400 1/min
1.10
1,200 1/min
1.00
1,000 1/min
0.90
800 1/min
P [kw/K]
0.80
0.70
0.60
0.50
0.40
0.30
0.20
10 20 30 40 50 60 70 80 90 100
Q [l/min]
Cooling capacity tolerance: 5 %
Flow Rate
Electrical data:
MTH 4-4 pump version
6.00 Permitted voltage range:
5.50 380 - 415 V 50 Hz 3 PH
5.00 380 - 440 V 60 Hz 3 PH
4.50 60 Hz Voltage tolerance: +5 % / -10 %
4.00
Motor output (50/60 Hz):
3.50
Pump: 0.96 / 1.51 kW
p [bar]
3.00 50 Hz
Fan: 0.98 kW
2.50
2.00
1.50
1.00
0.50
0.00
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70
Q [l/min]
Operating range: 10 70 l/min
Electrical data:
MTH 4-6 pump version
6.00 Permitted voltage range:
5.50 380 - 415 V 50 Hz 3 PH
5.00 Voltage tolerance: +5 % / -10 %
4.50
4.00 Motor output (50 Hz):
Pump: 1.34 kW
3.50 50 Hz Fan: 0.98 kW
p [bar]
3.00
2.50
2.00
1.50
1.00
0.50
0.00
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
Q [l/min]
Operating range: 30 100 l/min
Flow rate tolerance: 9 %, pumping head tolerance: 7 % as per DIN EN ISO 9906 Cl. 2, App. A
Note:
E 5.818.0/03.15
The operating point of the pump (flow rate) depends on the characteristic curve (line sizes, line lengths, screwing elements).
In general, the fewer the system losses, the greater the flow rate and the greater the cooling capacity.
Please contact Technical Sales with questions on cooling capacity and flow rate data with other operating fluids,
as well as on special voltages or other pumps.
249
Electrical Connection
The motor is electrically connected
by the customer using a heavy-duty
plug.
Additional 24 V DC control voltage,
more information available upon request.
Dimensions
[mm]
K
123 5
380 2
21
11
min. +5 min.
640 2 110 595 400
+5
1,038
+5
670 5 650
Note:
We recommend maintaining the specified minimum distance to ensure unimpeded air entry and exit.
Anything below the minimum distance can affect cooling capacity and noise emissions.
E 5.818.0/ 03.15
250
Model Type
FLKS-6-EC3-2.0-W-H4-4B0-2-0
Model
FLKS = Fluid /Air Cooling System
Size
Open-loop / closed-loop speed control
EC3 = Closed-loop speed control (with PID controller)
EC5 = Open-loop speed control (with temperature sensor)
Type code
Operating fluid
W = Water-glycol (standard)
Pump
H4-4 = Version with pump MTH4-4
H4-6 = Version with pump MTH4-6
Other pumps on request.
Motor voltage
B = 380-415 V 50 Hz / 380-440 V 60 Hz, 3PH (sump MTH4-4)
C = 380-415 V 50 Hz, 3PH (sump MTH4-6)
See also electrical data.
Position pump connection
0 = standard
Color
2 = light grey RAL 7035
Accessories
0 = no accessories (standard)
See table for corresponding accessory number.
E 5.818.0/03.15
251
Accessories
A Filling level and 60 C temperature switch
B Filling level switch (2 switching points)
D Flow switch
O Air filter
O Accessory number 0 1 44 30 14 59 122 105
See also Accessories for FLKS for more information.
A/B
FLKS-5EC Standard
Part no. Designation Pump Version
3952994 FLKS-6EC3/2.0/W/H4-4B0/2/0 MTH4-4 no accessories, closed-loop speed control
3952889 FLKS-6EC3/2.0/W/H4-6C0/2/0 MTH4-6 no accessories, closed-loop speed control
E 5.818.0/ 03.15
252
FLKS Accessories
K Flow Switch
1 4
For monitoring the continuous flow of the operating fluid.
Accessory no.: 30
Air Deflection
For directing the flow of air upward.
FLKS-5S/-5EC and FLKS-6S/-6EC come with an air deflection standard.
Accessory no.: 36
E 5.818.0/03.15
253
Possible Accessories Combinations:
Flow switch
Air filter
Air deflection
254
Fluid-Air Cooling Systems
Speed Controlled Systems
FLKS-2EC, FLKS-3EC, FLKS-4EC,
FLKS-5EC und FLKS-6EC
Lower speed
= lower noise level
= lower energy consumption
= lower contamination level
= no condensation in electrical
components at low ambient
temperatures
The FLKS-EC HYDAC Cooling series
offers various possibilities for open-loop
and closed-loop control. This means
the right solution can be found for every
application.
It is available in sizes FLKS-2EC,
FLKS-3EC, FLKS-4EC, FLKS-5EC and
FLKS-6EC.
E 5.818.0/03.15
255
FLKS with a Constant Speed (FLKS-xS)
The FLKS with AC fan drive operates with a constant speed
and is therefore ideally suited to use in air conditioned machine halls.
1 AC fan
20
10
T
0
-10
Time
256
FLKS with Open-loop Speed Control (FLKS-xEC5)
The FLKS with an EC fan drive is also equipped with a temperature sensor. The analog signal 0 10 V of the sensor is assigned
a temperature range of +25 up to +45 C. An analog signal is forwarded to the EC fan for open-loop control according to the fluid
outlet temperature measured. The fan switches on at 1.5 V (= +28 C) and reaches its maximum speed at 10 V (= + 45 C).
This FLKS is particularly suited to outdoor installation (e.g. for inverter cooling in cogeneration plants).
1 [1/min]
1,600
240
30
Temperature
25
20
variable speed T
15
10
0
Time
257
FLKS with Closed-loop Speed Control (FLKS-xEC3)
Closed-loop control is when measurements are continually taken to determine to what extent the control variable corresponds
with the reference variable and in contrast to open-loop control a deviation automatically leads to adjustment of the control
variable.
A temperature sensor measures the outlet temperature (control variable). This is continuously compared with the reference
variable (ambient temperature + T). The PID controller continually adjusts the speed of the fan, in order to align the outlet
temperature with the ambient temperature.
The FLKS with closed-loop speed control is mainly used in machine tools where high fluid temperature accuracy is required.
3 2
26
24
22
constant speed
20
Time
E 5.818.0/ 03.15
258
Note
Inlet and outlet of the fluid refer
to the cooling system, i.e. inlet
from the appliance to FLKS,
outlet from FLKS to the appliance.
The diagrams on the FLKS
with constant speed and with open-loop
speed control were created from tests
in the cold chamber; the diagrams on
closed-loop speed control were created
from measuring results from practical
tests on a machine tool.
E 5.818.0/03.15
259
Fluid/Air Cooling System (FLKS) Design Sheet
Project:
Contact:
Phone:
E-mail:
Author: Date:
Application:
Operating fluid temperature: Flow to consumer: C
Altitude: m..NN
Site: Indoors
Outdoors
Cavity: Height: mm Width: mm Depth: mm
Control options of
operating fluid temperature: None
Open-loop speed control (FLKS-xEC5), e.g. for outdoors
Closed-loop speed control (FLKS-xEC3)
E 5.818.0/ 03.15
260
Accessories: Filling level and temperature switche
Filling level switch
Flow switch
Air filter
Air deflection
Other
Other requirements:
E 5.818.0/03.15
261
Note
The information in this brochure
relates to the operating conditions.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications.
262
Fluid-Water
Cooling Systems
FWKS
Application Field
ll Fluid-cooled drives:
Motor spindles, torque motors,
servomotors, linear motors
ll Inverter cooling
ll Gearbox cooling and lubrication
ll Bearing cooling
ll Tool cooling
E 5.618.0/03.15
263
Function
The pump conveys the operating fluid
from the tank through the part of the Inlet
operating fluid
consumer being cooled.
The operating fluid absorbs the heat and
flows through the plate heat exchanger,
Outlet
where it is cooled by the coolant flowing coolant
in the opposite direction.
The operating fluid is then fed back Outlet
to the tank. operating fluid
Inlet
coolant
Control Options
In unregulated systems, the maximum quantity of coolant is always pumped through the plate heat exchanger regardless
of the power input of the consumer. The FWKS with temperature control can change that by adding a valve that adjusts
the amount of coolant to the requirements of the consumer. This means only the coolant that is needed to maintain
the specified flow temperature is used. This is why regulated systems are particularly energy-efficient and conservative.
The FWKS series offers a number of control and regulating options.
This means the right solution can be found for any application.
Application:
ll Fixed value control to 3 C
ll Power cooling
ll Protection against condensation
ll No electricity required for controller
Application:
ll Precision cooling to 0.5 C
ll Protection against condensation
ll Fixed value setting or differential temperature regulation
E 5.618.0/ 03.15
264
FWKS-0/1.x FWKS-2/1.x
FWKS-2/2.x FWKS-3/2.x
E 5.618.0/03.15
265
Specification Sheet Fluid/Water Cooling System (FWKS)
Project:
Contact:
Phone:
E-mail:
Date Author
General
Required cooling capacity: kW
Site:
Hot side
Operating fluid: Operating fluid: % glycol: %
Viscosity at 10 C: cSt
Viscosity at 40 C: cSt
Operating fluid temperature: Flow to consumer: C
Cold side
Coolant supply:
266
Control of operating
fluid temperature: None
Mechanical control
Electronic control
Accessories:
Filling level and temperature switch
Flow switch
Other requirements:
E 5.618.0/03.15
267
Note
The information in this brochure
relates to the operating conditions.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications.
268
Chiller System
RFCS
Application Field
Symbol
ll Machine tools Whether integrated into a machine or used as a
Refrigeration circuit Condenser separate auxiliary cooler or insertion cooler, the
ll Presses
Cooling circuit RFCS range of chillers will tackle any cooling
ll Milling machines task and guarantees quality for your products
Safety and with utmost precision.
regulation unit ll Welding systems
Compressor ll Laser cooling
Pump Evaporator
RFCS-G series
Cooling fluid
General
The RFCS cooling unit (chiller) is used
to cool various liquids such as water,
water glycol or oil down to the ambient
temperature or below. The chiller
system consists of refrigerator, pump,
tank and controller and is able to set
RFCS-D series
the temperature of the cooling media
to a previously configured target value
independently.
Product Features
ll Fluid cooling system as separate Separate auxiliary coolers with
auxiliary cooler or for integration into high capacities up to 160 kW
a machine for cooling tasks in the machine
tool sector. Several units can be
ll Can be used for any cooling tasks connected in parallel to expand
ll Stand-alone control of the system by the capacity as required.
means of innovative controller design
ll Condenser available as water-cooled
or air-cooled variant
ll Multiple cooling circuits Separate auxiliary cooler for
ll Precise temperature control cooling tasks in machine building
accuracies from 0.1 K (integration into the machine tool),
capacities up to 7 kW
ll Optional outdoor installation Temperature control / remote maintenance
ll Think green act green: energy-
efficient mixer principle available as
an option
E 5.824.1.0/03.15
269
Operating Data
Condenser Refrigerant
Cooling
Pump capacity / Electrical Dimensions Weight
Series power 1)
air- water- Direct 4) flow rate supply 1) LxDxH [mm] [kg]
[kW]
cooled cooled DI 2)
IW 3)
(without tank)
100 6) 150 l/min @ 3 bar 400/440V - 50/60Hz 1,860 x 1,000 x 2,021 780
135 6) 250 l/min @ 3 bar 400/440V - 50/60Hz 1,860 x 1,000 x 2,021 800
155 6) 250 l/min @ 3 bar 400/440V - 50/60Hz 1,860 x 1,000 x 2,021 900
1) Cooling capacity based on +35 C ambient air / water to condenser and +20 C process fluid supply temperature
2) DI = deionized water
3) IW = industrial water
4) Direct = Direct vaporization without refrigerant
5) Standard, additional voltages on request
6) Available as air-cooled variant with external condenser or heat exchanger
Accessories
ll Higher capacity pumps available
ll Several parallel circuits
ll Ambient temperature-dependent control
using separate temperature sensor
ll Serial interface for system monitoring
ll Filtration units for the refrigerant circuit
ll Flow indicator and flow monitoring
ll Extremely accurate control up to 0.1 K,
standard 1.5 K
ll Speed-controlled fans
E 5.824.1.0/03.15
270
Design
In the standard versions, the RFCS cooling units are designed complete with compressor, air cooled condenser,
submersible pump and electronic control. Optionally available with energy-efficient mixer control where a small
hysteresis is required.
G0 D2 D3
D4 G4 G5
E 5.824.1.0/03.15
G6 G7
271
Centralized Cooling Systems
RFCS water-chiller
with heat exchanger and HY-ECOBOX
Heat exchanger:
RFCS cooling units with water-cooled
condenser require a cooled water supply
for heat removal. A heat exchanger is
used when it is either not practical or not
desirable to utilize mains water. Functioning at high external temperatures
HY-ECOBOX:
The HY-ECOBOX is an optional module
which contributes to improved energy
saving: when the ambient temperature
drops below a certain level, the cooling
machine's active cooling is switched off.
The system then operates in passive
cooling mode, using the heat exchanger.
This energy manager can therefore
only be used in combination with a heat
exchanger.
Advantages:
ll Saves resources,
as no water is used
ll High energy-saving potential
thanks to the HY-ECOBOX*
ll The RFCS transfers no heat
into the building
Functioning at low external temperatures
* ECOBOX: optional accessory for
passive free cooling operation
E 5.824.1.0/03.15
272
From the prototype to series production
ll Planning and advice from our specialists on site.
You provide the task, we supply the solution.
ll Our own development centre produces market-driven, energy-efficient and cutting-edge solutions,
to stay one step ahead of the state of the art.
ll The coolers are produced in the Bavarian town of Friedberg
and rightly deserve the Made in Germany seal of quality!
ll In order to provide quality that is consistently very good, all equipment must undergo a function and performance test.
ll For service you can call on an international network of service engineers.
Consultation and service with global reach.
E 5.824.1.0/03.15
273
Design Data Sheet, RFCS Cooling Unit
Project:
Contact:
Telephone:
E-mail:
Date Created by
Application
Active cooling (RFCS): air-cooled
water-cooled
Series/housing*: D G
Technical data
Required cooling capacity: kW
at C operating temperature
Supply voltage: V Ph Hz
Cooling fluid/refrigerant
Cooling fluids: Water glycol % glycol: %
Pump specifications
Flow rate: l/min
274
Equipment Comment
Tank heating
Flow monitoring
Flow indicator
Controlled fan
DI cartridges
Conductance monitoring
Main switch
Design:
Supply / elec. connection (e.g. industrial connector, multi-pin)
Interface specification
Other accessories:
Comments:
* Series/housing:
The D basic housing is equipped with a horizontal condenser, making for flexible air routing/setup as access to the insides of
the devices only needs to be possible from one side. The G basic housing is fitted with an upright condenser to provide compact
E 5.824.1.0/03.15
275
Note
The information in this brochure
relates to the operating conditions and
applications described.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications and
corrections.
Germany
Tel.: +49 6897/509-01
Fax: +49 6897/509-454
E-mail: cooling@hydac.com
Internet: www.hydac.com
276
Cabinet Cooling
HCC
Product Features
ll Control cabinet cooler for roof
installation or wall/door mounting
ll Cooling capacities from 0.1 to 15kW
ll For all cooling applications in
switchgears or control cabinets Machine tools Thermal power plants Plastic injection machines
ll Stand-alone control of the system by
means of innovative controller design
ll Active cooler with compressor and
passive cooler with air/air or
air/water available
277
Technical Data
Active coolers
HCC-T-C HCC-S-C
current consumption
Power consumption
Cooling capacity
Starting current
setting range
Temperature
temperature
Dimensions
[V- Ph - Hz]
Maximum
Electrical
Ambient
Weight
supply
[mm]
[kg]
[C]
[C]
[W]
[W]
[A]
[A]
278
HCC-S-C side-mounted refrigeration cooler
Ambient temperature
current consumption
Power consumption
Cooling capacity
Electrical supply
Starting current
setting range
Temperature
Dimensions
[V- Ph - Hz]
Maximum
Weight
[mm]
[kg]
[C]
[C]
[W]
[W]
[A]
[A]
230-1-50/60 360-380 1.3 / 1.4 9.8 190 - 220
HCC-S-C-03 443 x 324 x 206 +25 / +45 +20 / +55 17.0
115-1-60 380 2.9 18.0 220
230-1-50/60 550-580 1.35 / 1.5 15.0 310 - 340 +25 / +45 23.0
400-2-50 500 0.7 15.0 310 - 340 +25 / +45 26.0
HCC-S-C-05 460-2-60 550 642 x 313 x 223 0.75 15.0 310 - 340 +25 / +45 +20 / +55 23.0
48 V DC 500 5.7 300 +25 / +35 23.0
115-1-60 580 4.7 17.0 340 +25 / +45 23.0
HCC-S-C-07S 230-1-50/60 800-850 550 x 279 x 286 1.9 / 2.0 9.6 450 - 490 +25 / +45 +20 / +55 20.0
230-1-50/60 850-900 2.6 / 2.7 20.0 420 - 600 27.0
400-2-50 800-850 1.0 20.0 420 - 600 30.0
HCC-S-C-08 642 x 313 x 223 +25 / +45 +20 / +55
400-2-60 800-850 1.4 20.0 420 - 600 30.0
115-1-60 900 7.2 28.0 600 27.0
230-1-50/60 1,100-1,150 3.1 / 3.4 18.0 510 - 650 44.0
400-2-50 1,050-1,100 1.7 / 1.8 30.0 510 - 650 50.0
HCC-S-C-11 912 x 410 x 248 +25 / +45 +20 / +55
460-2-60 1,050-1,100 1.7 / 1.8 30.0 510 - 650 50.0
115-1-60 1,150 7.5 34.0 650 44.0
230-1-50/60 1,500-1,600 3.9 / 4.3 28.0 750 - 825 46.0
400-2-50 1,400-1,500 2.5 / 2.6 110.0 750 - 825 53.0
HCC-S-C-15 912 x 410 x 248 +25 / +45 +20 / +55
460-2-60 1,400-1,500 2.5 / 2.6 100.0 750 - 825 53.0
115-1-60 1,600 9.4 50.0 825 46.0
230-1-50/60 1,500-1,600 3.9 / 4.3 28.0 750 - 825
HCC-S-C-15S 400-3-50 1,400-1,500 950 x 400 x 304 2.0 / 2.2 20.0 810 - 890 +25 / +45 +20 / +55 65.0
460-3-60 1,400-1,500 2.0 / 2.2 20.0 810 - 890
230-1-50/60 2,100-2,200 4.8 / 5.5 34.0 1,120 -1,240
400-3-50 2,000-2,100 2.5 / 2.7 22.0 1,100 -1,200
HCC-S-C-20 1,005 x 409 x 263 +25 / +45 +20 / +55 48.0
460-3-60 2,000-2,100 2.5 / 2.7 22.0 1,100 -1,200
115-1-60 2,200 60.0 1,240
230-1-50/60 2,550-2,750 4.2 / 5.2 18.0 1,100 -1,280 65.0
HCC-S-C-25S 400-3-50 2,400-2,600 1,580 x 400 x 305 3.0 / 3.2 22.0 1,230 -1,380 +25 / +45 +20 / +55 68.0
460-3-60 2,400-2,600 3.0 / 3.2 22.0 1,230 -1,380 68.0
230-1-50/60 3,000-3,150 5.0 / 5.5 35.0 1,370 -1,510 75.0
HCC-S-C-30 400-3-50 2,850-3,000 1,217 x 511 x 347 2.7 / 3.0 19.0 1,370 -1,510 +25 / +45 +20 / +55 80.0
460-3-60 2,850-3,000 2.7 / 3.0 19.0 1,370 -1,510 80.0
230-1-50/60 4,000-4,100 8.2 / 9.4 42.0 1,730 -1,950 80.0
HCC-S-C-40 400-3-50 3,950-4,050 1,217 x 511 x 347 2.9 / 4.0 25.0 1,730 -1,950 +25 / +45 +20 / +55 85.0
460-3-60 3,950-4,050 2.9 / 4.0 25.0 1,730 -1,950 85.0
400-3-50 5,600-5,950 4.2 / 5.7 2,670 - 3,600
HCC-S-C-60 1,405 x 554 x 404 53.0 +25 / +45 +20 / +55 100.0
460-3-60 5,600-5,950 4.2 / 5.7 2,670 - 3,600
HCC-T-C HCC-S-C
279
Technical Data
Passive coolers
HCC-S-AA
HCC-S-AW HCC-T-AW
Ambient temperature
Specific capacity
Electrical supply
setting range
consumption
consumption
Temperature
Dimensions
[V- Ph - Hz]
in watt/K
Current
Weight
Power
[mm]
[kg]
[C]
[C]
[W]
(A)
230-1-50/60 64
HCC-S-AA-16 16 410 x 204 x 109 0.60 -5 / +55 -5 / +55 4.6
115-1-60 40
HCC-S-AA-30 48 V DC 30 780 x 255 x 90 4.30 210 -5 / +55 -20 / +55 15.0
230-1-50/60 0.72 160
HCC-S-AA-35 230-1-60 35 780 x 254 x 90 0.80 150 -5 / +55 -5 / +55 7.5
115-1-60 1.10 180
230-1-50/60 0.72 160
HCC-S-AA-50 230-1-60 50 780 x 312 x 90 0.80 150 -5 / +55 -5 / +55 9.5
115-1-60 1.40 180
230-1-50/60 0.76 / 0.80 170 - 180 -20 / +55
HCC-S-AA-60 48 V DC 60 1,030 x 365 x 110 4.30 210 -5 / +55 -20 / +55 16.0
115-1-60 2.20 265 -40 / +55
E 5.825.1.0/03.15
Temperature range,
Specific capacity
Electrical supply
cabinet side
Dimensions
[V- Ph - Hz]
T = 25K
Current
Weight
[kPa]
[kPa]
[mm]
[l/h]
[kg]
[C]
[W]
(A)
230-1-50/60 0.28 / 0.24 33 / 36 +10 / +50
HCC-S-AW-06 230-1-60 870 403 x 306 x 113 0.50 24 150 500 2 0.2 7.0
115-1-60 0.50 24 0.2
230-1-50/60 0.26 / 0.34 58 / 75 +10 / +50
HCC-S-AW-15 230-1-60 2,200 916 x 402 x 206 0.80 75 150 1,000 30 0.2 21.0
115-1-60 0.80 90 0.2
230-1-50/60 0.38 / 0.40 85 / 90 +10 / +50
HCC-S-AW-25 230-1-60 3,100 916 x 402 x 206 1.00 90 500 1,000 63 0.2 22.0
115-1-60 1.00 115 0.2
230-1-50/60 0.70 / 0.95 115 / 215 +10 / +50
HCC-S-AW-50 230-1-60 6,700 916 x 402 x 206 1.30 285 860 1,000 40 +10 / +50 39.0
115-1-60 2.00 155 +10 / +50
Optional: Thermostat with solenoid valve, special colouring, UL design and stainless-steel housing available on request
Power consumption
Water temperature
Maximum current
Specific capacity
Power supply
consumption
Dimensions
[V- Ph - Hz]
T = 10 C
Weight
[mm]
[kg]
[C]
[W]
[A]
HCC-T-AW-15H 230-1-50/60 2,200 200 x 800 x 400 0.26 / 0.34 58 / 75 +10 / +50 +10 / +30 C 30.0
HCC-T-AW-50H 230-1-50/60 6,700 255 x 905 x 509 0.70 / 095 155 / 215 +10 / +50 +10 / +30 39.0
281
From the prototype to series production Note
ll Planning and advice from our specialists on site. The information in this brochure
You provide the task, we supply the solution. relates to the operating conditions and
ll Our own development centre produces market-driven, energy-efficient and applications described.
cutting-edge solutions, to stay one step ahead of the state of the art. For applications and operating conditions
ll In order to provide quality that is consistently very good, all equipment must not described, please contact the
undergo a function and performance test. relevant technical department.
ll For service you can call on an international network of service engineers. Subject to technical modifications and
Consultation and service with global reach. corrections.
Germany
Tel.: +49 6897/509-01
Fax: +49 6897/509-454
E-mail: cooling@hydac.com
Internet: www.hydac.com
282
Gearbox Cooling Systems
Filtration
In the main flow:
Combined filter consisting of a fine filter with bypass valve and a coarse filter
ll High contamination retention capacity, low differential pressure
ll High retention rates with excellent x value stability
Offline:
With compact offline flow filter specially designed for removing products
of oil ageing, solid particles and water (optional / customisable).
Cooling
Efficient and compact air cooling
with optional
ll Integrated thermal bypass (IBT)
ll Hot climate/cold climate versions
ll Fixings as part of the housing
Also available with a plate heat exchanger.
Circulation
For supplying the lubrication points
ll Electric and/or mechanical pump
ll Clogging indicator on the filter
ll Option to have MCS in the main flow to detect metallic particles
ll Gearbox inlet block with pressure and temperature monitoring available
Application Field
Large gearboxes between 100 kW and several MW
e.g. in
ll Wind power
ll Cable winches
ll Vertical milling machines
E 5.705.0/03.15
283
Specification Sheet for Gearbox Cooling Systems
Project:
Contact:
Telephone:
E-mail:
Application
Gearbox designation:
Gearbox manufacturer:
Type/size: MW
Heat load / required
dissipation: kW
Oil:
Max. permissible
oil sump temperature: C (typically + 70C)
Start temperature
of the pump: C (typically 0 .. + 5C)
Location (country):
284
Electrical data
Voltage: 50 Hz: V 60 Hz: V
Documents
Specification available: Version no.
Number of items
Expected quantity
required per year 1st year 2 nd year 3 rd year
Items supplied:
Oil circulator
Cooler
Hoses
Steel frame
Sensors
285
Note
The information in this brochure
relates to the operating conditions and
applications described.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications and
corrections.
286
Water Glycol Circuits
WGK
Benefits:
ll Stops condensation from forming
ll No temperature shocks when turning on the air cooler at low air temperatures
ll By connecting additional fans, the cooling capacity can be adjusted as required
T
fan on
40C
(fan on)
30C
regulated mixing valve
25C
fan off
20C
unregulated
5C
heating
0C t
-10C
Application Field
ll Converters
ll Generators
ll Transformers
ll Inverters
E 5.706.0/03.15
287
Specification Sheet for Water Glycol Circuits
Project:
Contact:
Telephone:
E-mail:
Manufacturer:
Design
Ambient conditions
Ambient temperature
Electrical data
E 5.706.0/ 03.15
Rated power: MW
288
Ports
Ports on the component
being cooled:
Planned hose
length/nominal diameter:
Gearbox:
Others:
Comments
E 5.706.0/03.15
289
Note
The information in this brochure
relates to the operating conditions and
applications described.
For applications and operating conditions
not described, please contact the
relevant technical department.
Subject to technical modifications and
corrections.
290
Buyers Guide
Order Direct by Phone, Fax or Email
The products listed here are preferred sizes:
ll Single units are available ex stock or within 10 days
ll Easy to order using Part Number
ll Over 40 years experience in hydraulics
AC-LN
ll Axial fan
ll For oils and water glycol
ll Dynamic operating pressure: 16 bar
Cooling Cooling
Part No. Designation capacity capacity
Mineral oil* Water glycol*
3860765 AC-LN 2S/1.0/F/A/1 5.0 kW 5.3 kW
3860382 AC-LN 3S/1.0/F/A/1 9.0 kW 9.3 kW
3860090 AC-LN 4S/1.0/F/A/1 15.5 kW 17.3 kW
3859080 AC-LN 6S/1.0/F/A/1 25.0 kW 31.3 kW
3686305 AC-LN 8S/1.0/F/B/1 55.0 kW 57.3 kW
OSCA
ll Radial fan
ll For oils
ll With screw pump
Cooling Pump
Part No. Designation capacity flow rate
Mineral oil*
3926219 OSCA 0S/10/1.0/M/A/1 1.8 kW 15 l/min
3768893 OSCA 1L/10/1.0/M/A/1 3.7 kW 10 l/min
3684999 OSCA 1S/10/1.0/M/A/1 4.3 kW 15 l/min
3647770 OSCA 2L/28/5.0/M/A/1 7.0 kW 28 l/min
3647749 OSCA 2S/28/5.0/M/A/1 9.2 kW 40 l/min
3672255 OSCA 3S/28/5.0/M/A/1 15.0 kW 40 l/min
* At T = + 40 C
For further information, see brochure no. 5.811 (OSCA / OSCAF 1-3).
E 5.704.0/03.15
291
Brazed Plate Heat Exchangers
ll Stainless steel plates (AISI 316), copper-brazed
ll Stainless steel connections with female thread (standard)
ll Permitted operating pressure: 30 bar
For further information, see brochure no. 5.815 (Plate Heat Exchangers).
E 5.704.0/ 03.15
292
Clamping Bands for Brazed Plate Heat Exchangers
Part No. Designation Exchanger type
3092917 HRGBLPU 25 HEX-400 ST HYDAC HEX S400
3014028 HRGBLPU 25 HEX-610 ST HYDAC HEX S610
3014029 HRGBLPU 25 HEX-615 ST HYDAC HEX S615
3343306 HRGBLPU 25 HEX-522 ST HYDAC HEX S522
3013884 HRGBLPU 25 HEX-722 ST HYDAC HEX S722
For further information, see brochure no. 5.815 (Plate Heat Exchangers).
For 60 plates and above it is recommended that two clamping bands are used for installation.
MFZP
ll Vane pump with flanged motor
ll In direct drive version
ll Operating pressure: max. 6 bar
VPBM
ll Vane pump with bell housing, coupling and motor
ll Low-noise version
ll Operating pressure: max. 16 bar
For further information, see brochure no. 5.701 (Pumps FZP/ MFZP) and
brochure no. 5.702 (Pumps VP/ VPB/ VPBM).
E 5.704.0/03.15
293
Note
The information in this brochure
relates to the operating conditions and
applications described.
For applications and/or operating
conditions
not described, please contact the
relevant technical department.
Subject to
technical modifications and corrections.
294
STERREICH HYDAC-Bro Mnchen MEXICO KOREA
ROK
MEX
(Slovenia, Croatia, Bosnia- Herzegovina, Am Anger 8 HYDAC International SA de CV HYDAC Duwon Co. 13
A
Serbia and Montenegro, Macedonia) D-82237 Wrthsee/Etterschlag Pirul, 212 4th oor Wonwook Bldg.
HYDAC Hydraulik Ges. m.b.H. Tel.: 0 81 53 / 9 87 48-0 54090 Los Reyes Ixtacala 768-12 Bangbae, Seocho
Industriestr. 3 Fax: 0 81 53 / 9 87 48-4822 Tlalnepantla (Edo. de Mexico) ROK-Seoul 137-069
A-4066 Pasching HYDAC-Bro Nrnberg MEXICO Tel.: (0082) 2/591 09 31
Tel.: (0043) 72 29 / 6 18 11-0 Bauhofstrae 4 Tel.: (0052) 555 / 565 85 11 Fax: (0082) 2/591 09 32
Fax: (0043) 72 29 / 6 18 11-35 D-90571 Schwaig Fax: (0052) 555 / 390 23 34 E-mail: johnkim@hydackorea.co.kr
E-mail: info@hydac.at Tel.: 09 11 / 24 46 43-0 NORGE ROMANIA
ROM
AUSTRALIA Fax: 09 11 / 24 46 43-4260 HYDAC AS HYDAC SRL
N
AUS
HYDAC Pty. Ltd. DENMARK Postboks 657 Str. Vanatori Nr. 5 B
111 Dohertys Road, N-1401 SKI RO-100576 Ploiesti
DK
HYDAC A/S
Altona North. Havretoften 5 Tel.: (0047) 64 85 86 00 Tel.: (0040) 244 57 57 78
AUS-Vic. 3025 DK-5550 Langeskov Fax: (0047) 64 85 86 01 Fax: (0040) 244 57 57 79
postal address: Tel.: (0045) 702 702 99 E-mail: rmapost@hydac.no E-Mail: hydac@hydac.ro
P.O. Box 224, Altona North. Fax: (0045) 63 13 25 40 NETHERLANDS SVERIGE
AUS-Vic. 3025
NL
E-Mail: hydac@hydac.dk HYDAC B.V. HYDAC Fluidteknik AB
S
Tel.: (0061) 3 / 92 72 89 00 Vossenbeemd 109 Domnarvsgatan 29
Fax: (0061) 3 / 98 360 80 70 ESPAA
HYDAC TECHNOLOGY SL NL-5705 CL Helmond S-16308 Spnga
E
E-mail: info@hydac.com.au Tel.: (0031) 492 / 597470 Tel.: (0046) 8 / 4452970
Capcir 5, P.O. Box 162
BELGIQUE E-08211 Castellar del Valles Fax: (0031) 492 / 597480 Fax: (0046) 8 / 4452990
HYDAC sprl E-mail: nl-info@hydac.com Internet: www.hydac.se
B
NZ
HYDAC Ltd. SINGAPORE
SGP
Tel.: (0032) 12 260 400 EGYPT
Unit 14, 13 Highbrook Drive Hydac Technology Pte Ltd.
ET
Fax: (0032) 12 260 409 Yasser Fahmy Hydraulic Eng.
65-66-68 Saudi Building, Kobba East Tamaki 2A Second Chin Bee Road
BULGARIA P.O. Box 6550 Sawah 11813 NZ-Auckland Singapore 618781
BG
HYDAC EOOD ET-Cairo Tel.: (0064) 9271 4120 Tel.: (0065) 6741 7458
Business Center Iskar Yug Tel.: (0020) 2 / 45 20 192, 45 30 922 Fax: (0064) 9271 4124 Fax: (0065) 6741 0434
Mnchen-Str. 14 45 30 923, 45 01 970 PORTUGAL SLOVAKIA
BG-1528 Soa
SK
Fax: (0020) 2 /45 30 638 CUDELL Engenharia & Servios, Lda. HYDAC, s.r.o.
P
Tel.: (00359) 2 970 6000, E-Mail: yasserf@yf-hydraulic.eg Rua Eng. Ferreira Dias, 954 Schmidtova 14
(00359) 2 970 6060 P-4149-008 Porto SK-03601 Martin
Fax: (00359) 2 970 6075 FRANCE
HYDAC S..r.l. Tel.: (00351) 22 / 6158029 Tel.: (00421)- 43-4135893, 4237394
F
SL
Fax: (0033) 3 87 85 90 81 Rua Prof. Henrique de Barros 5 B HYDAC d.o.o. Slovenia
BY 220035 Minsk Belarus E-Mail (sige): 2685-339 Prior Velho Zagrebska c. 20
Tel.: (00375) 17 209 01 32-33 hydac_france@hydac.com P-1801 Lisboa Codex SL-2000 Maribor
Fax: (00375) 17 209 01 35 E-Mail (agence Nord-Est): Tel.: (00351) 219 429 900 Tel.: (00386) 2 /460 15 20
E-Mail: info@hydac.com.by ag_nest@hydac.com Fax: (00351) 219 413 500 Fax: (00386) 2 /460 15 22
Internet: www.hydac.com.by Internet: www.movicontrol.pt E-mail: info@hydac.si
AGENCE DE PARIS:
BRASIL Tel.: (0033) 1 60 13 97 26 E-Mail: geral@movicontrol.pt THAILAND
BR
T
Rua Fukutaro Yida, 225
PL
AGENCE DE LYON: (Lithuania, Latvia) 169/4, 169/5 Moo 1
CEP 09852-060 HYDAC Sp. z o.o. Rangsit-Nakhonnayok Rd.
BR-Sao Bernardo do Campo-SP Tel.: (0033) 4 78 87 83 02
E-mail: ag_lyon@hydac.com ul. Reymonta 17 Lampakkud, Thanyaburi
Tel. (0055) 11/43 93 66 00 PL-43-190 Mikoow Patumthanee 12130
Fax: (0055) 11/43 93 66 17 AGENCE DE BORDEAUX: Tel.: (0048) 32 226 26 55, 32 326 29 00 Tel.: (0066) 2577 2999 (30 lines)
E-mail: hydac@hydac.com.br Tel.: (0033) 5 57 54 25 20 Fax: (0048) 32 226 40 42, 32 326 29 01 Fax: (0066) 2577 2700
CANADA E-Mail: info@hydac.com.pl Email: info@aerouid.com
CDN
AGENCE DE CHATEAUNEUF
HYDAC Corporation LES MARTIGUES: CHINA TURKEY
PRC
14 Federal Road
TR
Tel.: (0033) 4 42 49 61 35 HYDAC Technology (Shanghai) Ltd. HYDAC Ltd. Sti.
Welland, Ontario 28 Zhongpin Lu Namk Kemal Mahallesi
L3B 3P2 FINLAND
Shanghai Minhang Economic & Adile Nasit Bulvar
FI
TW
Allmendstr. 11 HYDAC International HYDAC Technology Ltd.
CH-6312 Steinhausen/Zug GREAT BRITAIN
GB
HYDAC TECHNOLOGY Limited ul. 4-ya Magistralnaya, 5, ofce 31 No. 18 Shude 1st Lane, South District
Tel.: (0041) 41 / 747 03 20 RUS 123007 Moscow TW-Taichung City/Taiwan 40242
Fax: (0041) 41 / 747 03 29 De Havilland Way, Windrush Park
GB-Witney, Oxfordshire Tel.: (007) 495 980 80 01-03 Tel.: (00886) 4 / 2260 22 78
E-mail: hydac-engineering-AG@hydac.com Fax: (007) 495 980 70 20 Fax: (00886) 4 / 2260 23 52
Internet: www.hydac.ch OX29 0YG
Tel.: (0044) 1993 866366 E-Mail: info@hydac.com.ru E-Mail: sales@hydac.com.tw
HYDAC S.A. Fax: (0044) 1993 866365 Internet: www.hydac.com.ru UKRAINE
UKR
Zona Industriale 3, Via Sceresa Internet: www.hydac.co.uk Technical Ofce St. Petersburg HYDAC Ukraine
CH-6805 Mezzovico E-Mail: info@hydac.co.uk Obvodnyi chanel emb., 138, Bro Kiev
Tel.: (0041) 91 / 935 57 00 blok 101, of 401 ul. Novokonstantinovskaya, 9,
Fax: (0041) 91 / 935 57 01 GREECE
GR
Delta-P Technologies Ltd. RUS 190020 St. Petersburg Korpus 13, 2 Etage
E-mail: info.coolingsystems@hydac.ch Tel.: (007) 812 495 94 62 UA 04080 Kiev
Internet: www.hydac.ch 2, Grevenon Str.
GR-11855 Athens Fax: (007) 812 495 94 63 Tel.: (0038) 044 495 33 96
ESK REPUBLIKA Tel.: (0030) 210 3410181 E-Mail: petersb@hydac.com.ru (0038) 044 495 33 97
CZ
HYDAC S.R.O. Fax: (0030) 210 3410183 Technical Ofce Novokuznetsk Fax: (0038) 044 495 33 98
Kanadska 794 E-Mail: delta_pi@otenet.gr ul. Nevskogo, 1, ofce 300 E-mail: info@hydac.com.ua
CZ-39111 Plan nad Luznici RUS 654079 Novokuznetsk USA
MAGYARORSZG
USA
HYDAC-Bro Sdost Tsim Sha Tsui Kowloon, Hong Kong HYDAC TECHNOLOGY Executive ofce, Room 7,
Wiesestr. 189 Tel: (00852) - 23 - 69 35 68 ARGENTINA S.R.L. 364, Cong Hoa Street,
D-07551 Gera Fax: (00852) - 23 - 69 35 67 Av. Belgrano 2729 Tan Binh District
Tel.: 03 65 / 73 97-5320 (B1611DVG) Don Torcuato VN-Ho Chi Minh City
Fax: 03 65 / 73 97-5310 ITALIA Tel.: (00848) 812 0545 Etx: 215 & 214
HYDAC S.p.A. RA-Tigre / Buenos Aires
I
D-14979 Grobeeren Tel.: (0039) 039 / 642211 E-Mail: argentina@hydac.com (Namibia, Zimbabwe)
Tel.: 0 33701 / 3389-0 Fax: (0039) 039 / 6899682 CHILE HYDAC Technology Pty Ltd.
RCH
Fax: 0 33701 /3389-4499 Internet: www.hydac.it HYDAC Tecnologia Chile Ltda 165 Van der Bijl Street
HYDAC-Bro Bremen E-mail: hydac@hydac.it Las Araucarias # 9080 - 9110 Edenvale 1614
Riedemannstrae 1 Parque Industrial Las Araucarias ZA-Johannesburg
INDIA Tel.: (0027) 11 723 90 80
IND
D-45145 Essen
Tel.: 02 01 / 3 20 89 51-00 Route dEsch, C.P. 38
Fax: 02 01 / 3 20 89 52-22 L-3801 Schifange
Tel.: (00352) 54 52 44
HYDAC-Bro Mitte Fax: (00352) 54 52 48
Dieselstr. 9
MALAYSIA
MAL
D-64293 Darmstadt
Tel.: 0 61 51 / 81 45-0 HYDAC Technology Sdn. Bhd.
Fax: 0 61 51 / 81 45-22 No. 16 Jalan Pengacara U1/48
Temasya Industrial Park
HYDAC-Bro Sdwest
E 57.000.0/ 03.15
295
Accumulator Technology 30.000
Global Presence.
Local Expertise.
www.hydac.com
Filter Technology 70.000
Process Technology 77.000
Filter Systems 79.000
Compact Hydraulics 53.000
HYDAC Headquarters
HYDAC Companies
HYDAC Sales and Service Partners
Accessories 61.000
Electronics 180.000