You are on page 1of 10

WORK INSTRUCTION/ Ref. No.

: SPCT/Eng/WI/029
HNG DN CNG VIC Version: 1.0
ENGINEERING
DEPARTMENT Name: QC Maintenance Rope Tension

Written by: Reviewed by: Approved by:

Tran Minh Duc Nguyen Xuan Huy Do Thanh Vu

QC Maintenance rope
tension

Base on requirement of/ Tun th theo:

DPW Engineering Policy Standards ver. 4

SPCT Engineering Management System

Responsible person: Page 1 of 10 Effective Date:8 Dec2013


Shift Engineers Version No.: 1.0 Review Date: 8Dec2015

Uncontrolled document when printed, check SPCT Eng. Dept. for latest version if available.
WORK INSTRUCTION/ Ref. No.: SPCT/Eng/WI/029
HNG DN CNG VIC Version: 1.0
ENGINEERING
DEPARTMENT Name: QC Maintenance Rope Tension

Table of contentsPage No.

1.0 REVISION HISTORY/ LCH S HIU CHNH ..................................................... 3


2.0 PURPOSE/ MC CH ........................................................................................ 4
3.0 SCOPE/ PHM VI P DNG............................................................................... 4
4.0 REFERENCES/ TI LIU THAM KHO ............................................................. 4
5.0 TERMS AND DEFINITIONS/ THUT NG V NH NGHA ............................. 4
6.0 ROLES AND RESPONSIBILITIES/ VAI TR V TRCH NHIM ...................... 5
7.0 PROCEDURE AND REQUIREMENTS/ QUY NH V YU CU ...................... 6
8.0 ATTACHMENT AND FORMS/ TI LIU NH KM .......................................... 8

Responsible person: Page 2 of 10 Effective Date:8 Dec2013


Shift Engineers Version No.: 1.0 Review Date: 8Dec2015

Uncontrolled document when printed, check SPCT Eng. Dept. for latest version if available.
WORK INSTRUCTION/ Ref. No.: SPCT/Eng/WI/029
HNG DN CNG VIC Version: 1.0
ENGINEERING
DEPARTMENT Name: QC Maintenance Rope Tension

1.0 REVISION HISTORY/ LCH S HIU CHNH

Revision Date Description Prepared By/ Reviewed By/ Approved By/


Hiu chnh Ngy
M t Chnh sa bi Xem xt bi Ph chun bi

20-
1.0 Nov- Initial issue Trn minh c (SE ) Nguyn Xun Huy (ME) Thanh V(DE)
2012

Responsible person: Page 3 of 10 Effective Date:8 Dec2013


Shift Engineers Version No.: 1.0 Review Date: 8Dec2015

Uncontrolled document when printed, check SPCT Eng. Dept. for latest version if available.
WORK INSTRUCTION/ Ref. No.: SPCT/Eng/WI/029
HNG DN CNG VIC Version: 1.0
ENGINEERING
DEPARTMENT Name: QC Maintenance Rope Tension

2.0 PURPOSE/ MC CH
Tun th theo DPW Engineering Policy v SPCT Engineering Management
System.
Gip nhng ngi thc hin cng vic ny hiu bit mt cch chnh xc
cng vic cn lm t thao tc thun li hn
3.0 SCOPE/ PHM VI P DNG
p dng trn ton b QCs ca cng SPCT
4.0 REFERENCES/ TI LIU THAM KHO

No Reference

1 Hydraulic manual

2 DP World Engineering Policy Standards ver. 4, 20 Oct 2011

5.0 TERMS AND DEFINITIONS/ THUT NG V NH NGHA

Term/ Thut ng Definition/ nh ngha


Shift Engineer l ngi chiu trch nhim chnh cho vic thc thi cng vic ny.
Person(s) in
Bn cnh , cc manager ca b phn K Thut v cc nhn vin k thut
charge
c quy nh cng c th thay th trong trng hp c yu cu
L t vit tt ca cm t Lock out/ Tag out L mt bin php nhm m
LOTO bo an ton cho con ngi bng cch c lp cc thit b trc khi cng vic
c tin hnh
WI Work Instruction hng dn cng vic
Walkie-Talkie B m - Phng tin lin lc v tuyn trong phm vi gn
E-stop Cng tc dng khn cp

Responsible person: Page 4 of 10 Effective Date:8 Dec2013


Shift Engineers Version No.: 1.0 Review Date: 8Dec2015

Uncontrolled document when printed, check SPCT Eng. Dept. for latest version if available.
WORK INSTRUCTION/ Ref. No.: SPCT/Eng/WI/029
HNG DN CNG VIC Version: 1.0
ENGINEERING
DEPARTMENT Name: QC Maintenance Rope Tension

6.0 ROLES AND RESPONSIBILITIES/ VAI TR V TRCH NHIM


Gim c k thut phi m bo
o Yu cu WI ny phi c tun th hon ton trong khu vc m h
chu trch nhim.
o m bo nhng ngun lc lin quan c sp xp hp l c th
hon thnh cng vic ny mt cch y nht.
o m bo hot ng xem xt, nh gi li c thc hin ng, nh k
WI ny lun ph hp vi cng vic.
o Tt c cc nhn vin c lin quan u phi c hun luyn v WI v
sau mi tin hnh cng vic trn.
o Tham kho kin v thng tin n cc nhn vin c lin quan.
Trng b phn k thut phi m bo
o Duy tr v nh gi nhm m bo WI ny c hiu lc thc thi trong
khu vc m h chu trch nhim.
o Nhng yu t cn thit thc hin WI ny c tham kho t cc
thnh vin c lin quan.
o m bo hot ng xem xt, nh gi li oc thc hin ng, nh k
WI ny lun ph hp vi cng vic.
o Cc hot ng, quy trnh mi hoc c nhng thay i cn phi c
nhn din, nh ngha v vn bn h.
o Tt c nhng giy t lin quan n WI ny c hon thin v duy tr
trong ni lu tr
o Tt c cc nhn vin c lin quan u phi c hun luyn v WI v
sau mi tin hnh cng vic trn.
Ngi thc hin cng vic phi m bo
o Tun th ng theo nhng yu cu ca WI ny trong mi trng hp.
o Tham gia cc kha hun luyn theo yu cu ca WI.
o Cung cp y nhng h tr v hng dn cho WI ny.
o Gim st y hot ng theo WI ny.
o Bo co nhng vn kh khn nu c.

Responsible person: Page 5 of 10 Effective Date:8 Dec2013


Shift Engineers Version No.: 1.0 Review Date: 8Dec2015

Uncontrolled document when printed, check SPCT Eng. Dept. for latest version if available.
WORK INSTRUCTION/ Ref. No.: SPCT/Eng/WI/029
HNG DN CNG VIC Version: 1.0
ENGINEERING
DEPARTMENT Name: QC Maintenance Rope Tension

7.0 PROCEDURE & REQUIREMENTS/ QUY NH V YU CU

ITEM ACTION INSTRUCTION PICTURES / DETAILS PERSON(S) IN


Bc Hot ng Hnh nh chi tit CHARGE
Ngi thao tc

Chun b dng c,
ngh,bo h lao ng, hai
1 ngi trc khi tho
lp(c l tua vit )..

Shift Engineer/
Technician

Treo bng cnh bo di


chn gantry trc khi
bo dng.
2

Shift Engineer /
technician

Responsible person: Page 6 of 10 Effective Date:8 Dec2013


Shift Engineers Version No.: 1.0 Review Date: 8Dec2015

Uncontrolled document when printed, check SPCT Eng. Dept. for latest version if available.
WORK INSTRUCTION/ Ref. No.: SPCT/Eng/WI/029
HNG DN CNG VIC Version: 1.0
ENGINEERING
DEPARTMENT Name: QC Maintenance Rope Tension

ng emergency ct
ngun trc khi bo
dng.

3
Shift Engineer /
technician

Ct bm khi bo dng.

Shift Engineer /
technician

Responsible person: Page 7 of 10 Effective Date:8 Dec2013


Shift Engineers Version No.: 1.0 Review Date: 8Dec2015

Uncontrolled document when printed, check SPCT Eng. Dept. for latest version if available.
WORK INSTRUCTION/ Ref. No.: SPCT/Eng/WI/029
HNG DN CNG VIC Version: 1.0
ENGINEERING
DEPARTMENT Name: QC Maintenance Rope Tension

M valve gim p cho


du v thng trc khi
thay pht xy lanh.

Shift Engineer /
technician
5 Valve gim p

.
M valve gim p cho
du tr v thng cha.

Shift Engineer /
technician
Valve gim p

Responsible person: Page 8 of 10 Effective Date:8 Dec2013


Shift Engineers Version No.: 1.0 Review Date: 8Dec2015

Uncontrolled document when printed, check SPCT Eng. Dept. for latest version if available.
WORK INSTRUCTION/ Ref. No.: SPCT/Eng/WI/029
HNG DN CNG VIC Version: 1.0
ENGINEERING
DEPARTMENT Name: QC Maintenance Rope Tension

M bulong xy lanh x du
tn ng li trc khi tho
pht xy lanh.

7 Shift Engineer /
technician

Bulong x y xy
lanh

Tho xy lanh thay


pht.Kim tra ng
ng,xy lanh t s r r.
Qui trnh lp th ngc
li.

Shift Engineer /
8 technician

Tho LOTO v safety


cone khi hin
trng,bn giao thit
b cho khai thc.

Responsible person: Page 9 of 10 Effective Date:8 Dec2013


Shift Engineers Version No.: 1.0 Review Date: 8Dec2015

Uncontrolled document when printed, check SPCT Eng. Dept. for latest version if available.
WORK INSTRUCTION/ Ref. No.: SPCT/Eng/WI/029
HNG DN CNG VIC Version: 1.0
ENGINEERING
DEPARTMENT Name: QC Maintenance Rope Tension

ATTACHMENT & FORMS/ TI LIU NH KM

Responsible person: Page 10 of 10 Effective Date:8 Dec2013


Shift Engineers Version No.: 1.0 Review Date: 8Dec2015

Uncontrolled document when printed, check SPCT Eng. Dept. for latest version if available.