You are on page 1of 4

Shenzhen Qianhai Lensen Technology Co.

, Ltd
Wireless Water Level Monitoring System

Features:
Monitor remote side water tanks level value and reveal on touch panel
Switches ON the pump when the water in the remote tank goes low level.
Switches OFF the pump when the water in the remote tank reaches high level.
Wireless connection, no need to switch ON/OFF the pump manually.
No more overflow thus saving water electricity & manpower.
Easy installation. No communication fee.

Hardware needed:
1. 24V DC Power supply (12V customize)
2. Thrown-in level sensor
3. LS-RAI02 analog acquisition module
4. Pump
5. LS-RDIO0202B (with antenna)
6. Solid state relay
7. HMI

System diagram

Contact: Sunny Web: www.lensen-tech.com Email: sunny@lensen-tech.com


Shenzhen Qianhai Lensen Technology Co., Ltd
How to connect tank side
Connect level sensor with our LS-RAI02

About LS-RAI02
It is an analog acquisition module. OK to collect 4-20mA analog signal and wireless transmit to remote
side. Support 2-wire sensor or 3-wire sensor. In this application, you use only 1AI.

Frequency 433MHz or 450MHz or 470MHz

Power output 1W for 2km LOS control

Products 1AI

Input type 4-20mA or 0-5V

Resolution ratio 24 bit

Accuracy 0.04%

Power supply 9-36V DC usually use 24V DC

Interface RS-485

Channel No. 16ch default, can program via DIP switch

Working temperature -35 C ~ +75 C industrial

Dimension 1159040(mm)

Fix way Standard 3.5 inch industrial DIN guild rail

Contact: Sunny Web: www.lensen-tech.com Email: sunny@lensen-tech.com


Shenzhen Qianhai Lensen Technology Co., Ltd
How to connect pump side
LS-RDIO0202 has 1 relay output, wireless RS485 port A3 and B3 to connect with HMI.

About LS-RDIO0202. In this project, you use only 1 output.


Parameter

Power output: 1W

Power supply 9V-30V (choose 24V DC or 12V DC)

Control distance: 3km or (1km version)

Output: 2 relay output, contact AC250V/5ADC30V/5A

Transmitting current: 450mA

Communication port RS485 (wireless RS485)

Frequency: 433MHz,400, 450,470 or other band

Channel No 16 channels, can change via DIP switch

Dimension: 1159040(mm)

Temperature: -35~+75( industrial)

Mounting method: Standard 3.5 inch industrial guild rail

Contact: Sunny Web: www.lensen-tech.com Email: sunny@lensen-tech.com


Shenzhen Qianhai Lensen Technology Co., Ltd
How to set channel and ID
2 modules should set with the same ID, the same channel.
One set as master and one set as slave

About the HMI program


If you could write HMI yourself, thats better. If not, we can also provide you HMI with program.
Any further questions about it, welcome to contact Sunny freely.

Contact: Sunny Web: www.lensen-tech.com Email: sunny@lensen-tech.com

You might also like