VISTA-128BPT SERIES

PARTITIONED COMMERCIAL BURGLARY


ALARM CONTROL PANELS

The VISTA-128BPT is a powerful member of the Honeywell The VISTA-128BPT and VISTA-128BPTSIA are listed for
family of commercial alarm panels, integrating burglary, CCTV residential burglary, residential fire and commercial burglary
and access control functions. Many features are available that applications (see agency listings in this document for
extend the applications of the VISTA-128BPT while simplifying more details). They are compatible with a wide range of
end-user operation. AlarmNet communications products for alarm reporting,
uploading /downloading and remote services.

FEATURES
Standard features Zone 7 may be used for keyswitch Group bypass
(VISTA-128BPT and VISTA-128BPTSIA): arming/disarming Arm faulted
Provides nine style-B hardwired zones Integrates with WIN-PAK access Event arming
Supports up to 119 additional zones control systems to provide increased
users, event log and scheduling Carbon monoxide (CO) zone
using a built-in polling (V-Plex,
type support
multiplex) loop interface Supports V-Plex addressable
VistaKey access control (up to eight Expanded high-speed RS-232
Supports up to 127 wireless zones
doors and 250 cards) capability for third party interface
using up to two 5800 series wireless
and automation
receivers (fewer if using hardwire Easily programmed and maintained
and/or polling loop zones) by Compass Windows-based Internet upload/download
downloader over AlarmNet GSM and/or
Provides one power-limited bell circuit
IP communicators over the panel's
delivering 1.7Amp (max) at 12VDC Supports up to 96 programmable keypad (ECP) bus
Provides the ability to control eight outputs
Ringback support for AlarmNet
separate partitions independently, Programmable to meet SIA false communicators (confirmation of
each functioning as if it had its own alarm prevention specifications. closing report)
separate control To meet UL approval for ANSI/SIA
CP-01-2010, order part number 24-hour dialer test support for
Accommodates 150 user codes with
V128BPTSIA AlarmNet devices
seven authority levels
Supports up to six touchscreen Supports V-Plex Smart Contact
Accommodates 32 keypad macro
Advanced User Interface (AUI) feature for improved responsiveness
commands per system
devices (6272 or later) on systems with many V-Plex zones
Keeps a log of up to 512 events
Smoke detector reset at keypad Telco line cut detection
Supports up to 16 compatible
two-wire smoke detectors on zone 1 Quick exit
VISTA-128BPT SERIES
PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS
ADDITIONAL FEATURES
Basic Hardwired Zones Wireless Expansion Eight Partitions
Provides nine style-B hardwired zones Supports up to 127 wireless zones Provides the ability to control eight
with the following characteristics: using up to two 5800 Series wireless separate areas independently, each
EOLR supervision (optional for zones receivers (fewer if using hardwire functioning as if it had its own separate
2-8) supporting N.O. or N.C. sensors and/or polling loop zones). control. Partitioning features include:
(EOLR supervision required for fire Wireless zones have the following A Common Lobby partition (1-8),
and UL burglary installations) characteristics: which can be programmed to arm
Individually assignable to one of Supervised by control panel for automatically when the last partition
eight partitions check-in signals (except certain that shares the common lobby is
non-supervised transmitters) armed, and to disarm when the first
Up to 16 two-wire smoke detectors
partition that shares the common
on zone 1 Tamper protection for supervised
lobby is disarmed
Four-wire smoke or heat detectors transmitters
A Master partition (9), used strictly to
on zones 1-8 (power to four-wire Individually assignable to one of
assign keypads for the purpose of
smoke detectors must be supervised eight partitions
viewing the status of all eight partitions
with an EOL device). Listed for Scheduling at the same time (master keypads)
residential fire only.
Provides the following scheduling All zones assignable to one of
Polling Loop Expansion capabilities: eight partitions
Supports up to 119 additional zones Open/close schedules (for control of Keypads assignable to one of eight
using a built-in polling (V-Plex, multiplex) arming/disarming and reporting) partitions or to Master partition 9 to
loop interface. Current draw can total
Holiday schedules (allows different view system status
up to 128mA. Polling loop zones have
time windows for open/close Ability to assign relays to one or all
the following characteristics:
schedules) eight partitions
Must use V-Plex devices
Timed events (for activation of relays, Ability to display fire and/or burglary
Supervised by control panel auto-bypassing and unbypassing, and panic and/or trouble conditions
Individually assignable to one of auto-arming and disarming, etc.) at all other partitions keypads
eight partitions Access schedules (for limiting system (selectable option)
Supports VSI Module access to users by time) Individually programmable account
Supports 4297 Expander Module End user output programming mode number, entry delay and exit delay
Maximum wiring distance = (provides 20 timers for output control) by partition
12,000 feet

V-Plex Loop

5193
4101SN DT7500SN FG1625SN Glassbreak 4208EX Eight-zone 4293SN Adapters Series Smoke Detectors
Relay Module V-Plex DUAL TEC V-Plex Expander and
Motion Sensor 4208SN Serialized Eight-zone
Remote Point Module 5881
ECP Bus Wireless
Receiver

6160
Console
710
Strobe
Light VISTA-128BPT
4204
Notification Relay
Appliances Keyswitch Module
Option
4146

Serial Printer PC Connection Phone Line to Central Station


748
Horn
RS-232
or or
7847i GSMV iGSMV

NOTE: Please refer to the website (www.honeywell.com/security/hsc) for the latest product information.
VISTA-128BPT SERIES
PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS

ACCESSORIES
Auxiliary Devices Passive Infrared Detectors 5819 - Shock Sensor
4204 - Relay Module, four form IS2500SN 5827BD - Bidirectional Keypad
C contacts
DT7500SN 5853 - Glassbreak Detector
5881 Series - RF Receiver supporting
V-Plex (Addressable) Contacts 5898 - Wireless DUAL TEC
5800 wireless detectors
Motion Sensor
4939SN-WH
6160 - Alpha Keypad/Annunciator
5800PIR-OD - Outdoor Motion Sensor
4944SN-WH
6220S - System Printer
5870API - Asset Protection Device
4959SN
Manual Pull Stations
5800PIR/5800PIR-RES/5800PIR-COM
V-Plex Glassbreak Detectors
5140MPS-1 - Wireless Motion Detectors
FG1625SN
5140MPS-2 5800CO (5800COA - Canada) -
VISTA Interactive Phone Module Wireless Carbon Monoxide Detector
V-Plex (addressable) Devices
4286 VIP Module 5800RP - Wireless Repeater
4101SN Single Relay/Zone Module
Optional Communicators 5808W3 (5808W3A - Canada) -
4190SN Remote Point Module -
Wireless Smoke Detector
two zones AlarmNet Internet/Intranet
communicators and digital cellular 5809 - Wireless Heat Detector
4193SN Two-zone Serial Interface
communicators
Module Commercial Listed
Access Control Wireless Devices
4208EX - Eight-zone expander for
ULC commercial installations VISTAKey V-Plex (addressable) 5817CB - Commercial UL Burglary,
Access Control Universal Contact Monitoring
4208SN Loop Expansion Module -
Transmitter*
eight zones VISTAKey-SK Starter Kit
5869 - Commercial UL Wireless
4209U Group Zoning Module - VISTAKey-EX Expansion Kit
Hold-up Button*
two/four zones
Wireless Devices
5881ENHC and 5883H Receivers
4293SN One-zone Serial
5804 - Wireless Key
Interface Module *When used with 5881ENHC and/or
5804BD - Bidirectional Key 5883H receiver.
4297 Isolation/Extender Module
5804BDV - Bidirectional Key
VSI Short/Overload Isolation Module
with voice
5193SD
5816 - Door/Window Transmitter
5193SDT

4190SN 4959SN 4944SN


4193SN Remote Point Module Overhead Door Contact Contact
IS2500SN 4208U Two-zone Serial Interface Module
V-Plex PIR Eight-zone
Motion Sensor Expansion Module VISTAKey V-Plex
5808W3
5881ENHC (5808W3A - Canada) Glassbreak Detectors Access Control
Commercial Wireless Receiver Wireless Module
ECP Bus (Max Two) Smoke Detector 5800
Series
Wireless 5800PIR Series
6160 5816 Devices Wireless PIRs
Console Door/Window
Transmitter 4209U
Group Zoning
Module
5869
Commercial UL Supports Up To
Wireless Hold-up 5817CB Universal 16 Conventional
4204 Two-Wire
Relay Button Contact Monitoring Smoke Detectors
Module Transmitter
VISTA-128BPT SERIES
PARTITIONED COMMERCIAL BURGLARY ALARM CONTROL PANELS

SPECIFICATIONS
Agency Listed to the Electrical Standby Time: Four hours min. with
Following Standards: Voltage Input: From Honeywell No. 750mA aux. load using 7AH battery
UL609 Grade A Local Mercantile 1361 Plug-In Transformer or Circuit Protectors: PTC circuit
Premises and Mercantile Safe 1361X10 transformer (for X-10 breakers are used on battery input to
and Vault installations) rated 16.5VAC, 40 VA protect against reverse battery
UL1610 Grades A, AA Use 1361CN plug-in transformer connections and on alarm sounder
Central Station for Canada output to protect against wiring faults
(shorts). A solid state circuit breaker
UL365 Grades A, AA Police Connect Alarm Sounder Output:
is used on auxiliary power output to
UL985 Household Fire 10VDC-13.8VDC, 1.7 amps max.,
protect against wiring faults (shorts).
(UL1023, UL609 installations);
UL1023 Household Burglar Alarm Main Dialer
750mA less aux. current draw
California State Fire Marshall (CSFM)
(UL985 installations) Formats Supported: ADEMCO
UL1635 - Digital Alarm Contact ID with support for four-digit
Auxiliary Power Output: 9.6VDC-
Communicator System Units and ten-digit accounts and
13.8VDC, 750mA max. For UL
CAN/ULC - S303 installations, the accessories ADEMCO 4 + 2 Express
CAN/ULC - S304 connected to the output must be UL Line Seize: Double Pole
CAN/ULC - S545 Listed, and rated to operate in the Ringer Equivalence: 0.7B
above voltage range
CAN/ULC - S1023 Cabinet Dimensions
Backup Battery: 12VDC, 4AH or 7AH
For commercial burglary attack 12-1/2" W X 14 1/2" H X 3" D
sealed-lead acid. YUASA NP4-12
proof requirements, use N5873V4BE (12V, 4AH) or NP7-12 (12V, 7AH)
attack proof enclosure provided in recommended
VISTA-ULKT kit

ORDERING
VISTA-128BPT Commercial Burglary Alarm Control Panel (UL Listed)
V128BPTSIA SIA Approved Enhanced Commercial Burglary Alarm Control Panel (UL Listed)
V128BPTCNKT VISTA-128BPT Commercial Burglary Alarm Control Panel with 1361CN Transformer (Canada only)

For more information:


www.honeywell.com/security/hsc
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747
L/VSTA128BPTD/D
1.800.467.5875 April 2011