Professional Documents
Culture Documents
POWER COIL
90 kVA Solid-state GPU and Cable Coil in one enclosure
QUICK INSTALLATION
Traditionally, a 400 Hz ground power solution for passenger boarding bridges is made
up of entirely separate systems or parts. These typically include a GPU, a cable handling
system, interconnection cable and aircraft cable; components that are usually sourced
from different suppliers and require separate on-site installation and testing.
The AXA Power Coil combines all these parts in one state-of-the-art unit that comes
fully tested and adjusted from the factory - ready to be placed under the PBB. Mount
the unit under the bridge, connect the input cable and the power coil is ready for use.
This is easy and helps you save time and money!
Specifications
Denmark
tel: +45 63 18 60 00
fax: +45 63 18 60 49
e-mail: sales@itwgse.com
AXA 2400 Power Coil web: www.itwgse.com
August 2016_rev_A
Power: 90 kVA PF 0.8-1 MTTR: max. 20 minutes RS485
Voltage: 3 x 115/200 V Colour: RAL 7035 (standard) 26 or 28 m flexible composite cable
Frequency: 400 Hz 0.001 % Weight: 700 kg incl. 24 m cable instead of standard cable
Power factor: incl. strain relief
0.7 lagging to 0.95 leading Norms and Standards
Voltage regulation: Specifications for Coil DFS400 Specification for 400 Hz aircraft power
<0,5% for balanced and up to Cable/Connector ISO 6858 Aircraft ground support electric supplies
30% unbalanced loads Special twisted highly flexible cable BS 2G 219 General requirements for ground sup-
Voltage recovery: <8% and rec. time harness for power transfer from fixed
port equipment
<10 ms at 100% load change part to moving part
MIL-STD-704F Aircraft electric power characteristics
Total harmonic content: 24 m flexible composite cable
SAE ARP 5015 Ground equipment 400 Hz ground
<2% at linear load (typ. 1.5%), Aircraft connector with:
power performance requirement
<2% at non linear load according to - Start/stop push buttons
EN2282 Aerospace series characteristics of
ISO 1540 - Cable IN/OUT push buttons
aircraft electrical supplies
Crest factor: 1.414 3% - 90% Switch
Voltage modulation: <1.0% - Indication lamps EN62040-1-1 General & safety requirement
Phase angle symmetry: - Replaceable pins & front EN61558-2-6 General & safety requirement
120 1 for balanced load EN61000-6-4 Electromagnetic compatibility
120 2 for 30% unbalanced load Electro Mechanical System Generic emission standard
Cable drum with spiral cable trace EN61000-6-2 Generic immunity standard
Protection 1,1 kW gear motor EN1915-1&2 Machinery; general safety requirements
Protection class: IP55 VFD for gear motor EN12312-20 Machinery; general safety requirements
No break power transfer Coiling speed 40 m/min
Over/under voltage at output
Overload Protection
Internal high temperature Cable blocked
Control voltage error Motor overload
Short circuit at output
GPU Enable Common specification for GPU & Coil
90% switch interlock Input
Neutral voltage supervision Voltage range: 3 x 400 V 15%
Broken neutral supervision Frequency: 50/60 Hz 5 Hz
Leakage current supervision Rectification: Magnetic wave-shaping
incl. 12-pulse rectification Typically
Environmental Rated current: PF (load) 0.8 / PF 1 400 mm
[16 inch]
Operating temperature: 111 A 15% / 141 A 15%
-40C to +56C Line current distortion: <5%
(+60C at Aircraft Load) Power factor:
Relative humidity: 10-100% 90 kVA: 1 @ nominal load
1300 mm [51.4]