The GPU-409 ground power unit has a compact yet powerful 90 kVA design. It features an electronic control system that regulates frequency and protects the engine. The unit puts out 400Hz 115/200V power and has a generator control module that monitors output. It is mounted on a rugged chassis with steering and brakes for mobility near aircraft.
Original Description:
TLD GPU 400 hz 90 KVA , Diesel Driven , 28VDC optional as additional output
The GPU-409 ground power unit has a compact yet powerful 90 kVA design. It features an electronic control system that regulates frequency and protects the engine. The unit puts out 400Hz 115/200V power and has a generator control module that monitors output. It is mounted on a rugged chassis with steering and brakes for mobility near aircraft.
The GPU-409 ground power unit has a compact yet powerful 90 kVA design. It features an electronic control system that regulates frequency and protects the engine. The unit puts out 400Hz 115/200V power and has a generator control module that monitors output. It is mounted on a rugged chassis with steering and brakes for mobility near aircraft.
ELECTRONIC CONTROL with DIGITAL DISPLAY ENGINE CONTROLS
The GPU-409 Ground Power Unit features a compact design Electronic engine governors provide precise frequency with full-size performance which allows for easier handling and regulation and fast transient response. Engine protection such better mobility near aircraft. It features a brushless, high as low oil pressure and high coolant temperature are efficiency generator running at an optimized 1846 RPM programmed into the ECM. An engine diagnostic connector is providing improved fuel efficiency and reduced sound level provided for communicating with the engine. Engine operating while ensuring rapid transient response and exceptional parameters are displayed via SAE J1939 CANBUS: frequency regulation. - Engine speed, voltage, and hours Powder-coated aluminum and fiberglass panels surrounding a - Oil pressure and coolant temperature rugged galvanized steel chassis provide the longest lasting - Real time % load finish. Mobility is enhanced by a rubber torsion axle, tight radius - Active and stored service codes th 5 wheel steering, simple direct-acting brakes, and a safe no- - Various languages, US and Metric units drop towbar. The unit can meet U.S. Tier 4i. Other engines are Fuel level is displayed as a %. Low fuel warning and shut available for all emissions-regulated locations. down, automatic warm up and cool down cycles, and GENERATOR SPECIFICATIONS emergency stop are all standard features. 400 Hz 115/200 volts, +/- 15% adjustable, 3 phase, 4 wire wye- connected, grounded neutral, revolving field, brushless, self- ELECTRICAL CHARACTERISTICS cooling, single bearing, directly connected to the engine. - Continuous rating: 90 kVA @ 1.0 PF - Overload rating: 125% for 5 minutes @ 0.8 PF GENERATOR CONTROLS - Meets MIL-STD-704F Digital generator control module (GCM) features voltage - Voltage regulation: +/- 1% over full load range regulation, fault protection, and an operating parameter display. - Voltage transient: +/- 13.8% no load to full load The GCM monitors 400 Hz output when 400 Hz is in use and - Voltage transient recovery time: +/- 1% of nominal 28.5 VDC output when optional 28.5 VDC is in use. 400 Hz and voltage within 100 milliseconds 28.5 VDC line drop compensation and DC current limiting are - Voltage modulation: 0.5% at steady state. built in. Voltage, current, power, and frequency are digitally - Phase balance: <1% at balanced 3-phase load. displayed on a backlit LCD. Faults are displayed and latched: <4% at 1/3 load on 1 phase and no-load on 2 phases - Over frequency: 420 Hz in 5 seconds - Harmonic content: THD <2%. Any 1 phase - Under frequency: 380 Hz in 7 seconds harmonic <1.5% at 0.8 PF linear load - Over voltage: 130 volts in 2 seconds - Crest factor: 1.414 +/- 0.07 - Under voltage: 100 volts in 7 seconds - Frequency regulation: +/-0.1% over full load range - Overload: 125% of rated load for 5 minutes - Frequency transient: +/- 2.5% no-load to full load ENGINE SPECIFICATIONS - Frequency transient recovery time: +/- 0.5% of - 24 volt starting motor - Dry-type air cleaner nominal frequency within 1.5 seconds - Heavy-duty spark - (2) 12-volt batteries - Line drop compensation: Increases up to 10 VAC arrestor / silencer - Pusher type fan L-N to compensate for aircraft cable voltage drop - Full-flow oil and fuel filters - Low coolant shutdown - 400 Hz data logging – downloadable via USB stick
Tolerances of data: +/- 5 %.
Some views may show optional equipment. Specifications may be altered due to a constant effort to improve performance. GROUND POWER UNIT GPU-409 90 KVA
CHASSIS CHARACTERISTICS OPTIONAL EQUIPMENT
- Extreme low noise: 71 dbA @ 7 meters - Cable plug stowage / towbar brake interlock - Easy access to all components - Second 400 Hz output - Side mounted cable trays with integral rollers - Transformer rectifier: 28.5 VDC with current - Fuel tank – 46 gallons for over 8 hrs of run time limiting, 800 amps continuous, 2500 amps peak. - 5th wheel steering with no-drop towbar brake Can be field installed. - Forklift pockets and tie down rings - Beacon: Amber or red, flashing or rotating - Cable plug holders - Low fuel warning and shutdown beacons - Low load ramp down / no load shut down - Engine block heater - Externally-mounted, lockable, battery switch - Fuel filter/water separator with heater
Our GPUs are available in several engine configurations.
Each version meets at least your latest local emissions regulation RATED MODEL KVA P.F. KW AMPS GPU-409 90 0.8 72 260
TLD Sales and Service headquarters:
• Asia TLD-ASIA, Hong Kong Tel: + 852 (2) 692-2181 Fax: + 852 (2) 691-2604 • Europe, Africa, Middle East, India TLD-EUROPE, France Tel: + 33 (0) 1 45 60 71 40 Fax: + 33 (0) 1 45 60 57 00 • North & South America, Japan, Australia & New Zealand Revised 25OCT2013 CY TLD-AMERICA, USA Tel: + 1 (860) 602-3400 Fax: + 1(860) 688-7895
GPU-409_Datasheet_C Contact us on our Web Site: www.TLD-GSE.com
Tolerances of data: +/- 5 %.