You are on page 1of 2

GROUND POWER UNIT

GPU-409 90 KVA

ELECTRONIC CONTROL with DIGITAL DISPLAY ENGINE CONTROLS


The GPU-409 Ground Power Unit features a compact design Electronic engine governors provide precise frequency
with full-size performance which allows for easier handling and regulation and fast transient response. Engine protection such
better mobility near aircraft. It features a brushless, high as low oil pressure and high coolant temperature are
efficiency generator running at an optimized 1846 RPM programmed into the ECM. An engine diagnostic connector is
providing improved fuel efficiency and reduced sound level provided for communicating with the engine. Engine operating
while ensuring rapid transient response and exceptional parameters are displayed via SAE J1939 CANBUS:
frequency regulation. - Engine speed, voltage, and hours
Powder-coated aluminum and fiberglass panels surrounding a - Oil pressure and coolant temperature
rugged galvanized steel chassis provide the longest lasting - Real time % load
finish. Mobility is enhanced by a rubber torsion axle, tight radius - Active and stored service codes
th
5 wheel steering, simple direct-acting brakes, and a safe no- - Various languages, US and Metric units
drop towbar. The unit can meet U.S. Tier 4i. Other engines are
Fuel level is displayed as a %. Low fuel warning and shut
available for all emissions-regulated locations.
down, automatic warm up and cool down cycles, and
GENERATOR SPECIFICATIONS emergency stop are all standard features.
400 Hz 115/200 volts, +/- 15% adjustable, 3 phase, 4 wire wye-
connected, grounded neutral, revolving field, brushless, self- ELECTRICAL CHARACTERISTICS
cooling, single bearing, directly connected to the engine. - Continuous rating: 90 kVA @ 1.0 PF
- Overload rating: 125% for 5 minutes @ 0.8 PF
GENERATOR CONTROLS - Meets MIL-STD-704F
Digital generator control module (GCM) features voltage - Voltage regulation: +/- 1% over full load range
regulation, fault protection, and an operating parameter display. - Voltage transient: +/- 13.8% no load to full load
The GCM monitors 400 Hz output when 400 Hz is in use and - Voltage transient recovery time: +/- 1% of nominal
28.5 VDC output when optional 28.5 VDC is in use. 400 Hz and voltage within 100 milliseconds
28.5 VDC line drop compensation and DC current limiting are - Voltage modulation: 0.5% at steady state.
built in. Voltage, current, power, and frequency are digitally - Phase balance: <1% at balanced 3-phase load.
displayed on a backlit LCD. Faults are displayed and latched: <4% at 1/3 load on 1 phase and no-load on 2 phases
- Over frequency: 420 Hz in 5 seconds - Harmonic content: THD <2%. Any 1 phase
- Under frequency: 380 Hz in 7 seconds harmonic <1.5% at 0.8 PF linear load
- Over voltage: 130 volts in 2 seconds - Crest factor: 1.414 +/- 0.07
- Under voltage: 100 volts in 7 seconds - Frequency regulation: +/-0.1% over full load range
- Overload: 125% of rated load for 5 minutes - Frequency transient: +/- 2.5% no-load to full load
ENGINE SPECIFICATIONS - Frequency transient recovery time: +/- 0.5% of
- 24 volt starting motor - Dry-type air cleaner nominal frequency within 1.5 seconds
- Heavy-duty spark - (2) 12-volt batteries - Line drop compensation: Increases up to 10 VAC
arrestor / silencer - Pusher type fan L-N to compensate for aircraft cable voltage drop
- Full-flow oil and fuel filters - Low coolant shutdown - 400 Hz data logging – downloadable via USB stick

Tolerances of data: +/- 5 %.


Some views may show optional equipment. Specifications may be altered due to a constant effort to improve performance.
GROUND POWER UNIT
GPU-409 90 KVA

CHASSIS CHARACTERISTICS OPTIONAL EQUIPMENT


- Extreme low noise: 71 dbA @ 7 meters - Cable plug stowage / towbar brake interlock
- Easy access to all components - Second 400 Hz output
- Side mounted cable trays with integral rollers - Transformer rectifier: 28.5 VDC with current
- Fuel tank – 46 gallons for over 8 hrs of run time limiting, 800 amps continuous, 2500 amps peak.
- 5th wheel steering with no-drop towbar brake Can be field installed.
- Forklift pockets and tie down rings - Beacon: Amber or red, flashing or rotating
- Cable plug holders - Low fuel warning and shutdown beacons
- Low load ramp down / no load shut down - Engine block heater
- Externally-mounted, lockable, battery switch - Fuel filter/water separator with heater

Our GPUs are available in several engine configurations.


Each version meets at least your latest local emissions regulation
RATED
MODEL KVA P.F. KW
AMPS
GPU-409 90 0.8 72 260

TLD Sales and Service headquarters:


• Asia
TLD-ASIA, Hong Kong
Tel: + 852 (2) 692-2181 Fax: + 852 (2) 691-2604
• Europe, Africa, Middle East, India
TLD-EUROPE, France
Tel: + 33 (0) 1 45 60 71 40 Fax: + 33 (0) 1 45 60 57 00
• North & South America, Japan, Australia & New Zealand
Revised 25OCT2013 CY TLD-AMERICA, USA
Tel: + 1 (860) 602-3400 Fax: + 1(860) 688-7895

GPU-409_Datasheet_C Contact us on our Web Site: www.TLD-GSE.com

Tolerances of data: +/- 5 %.


Some views may show optional equipment. Specifications may be altered due to a constant effort to improve performance.

You might also like