Professional Documents
Culture Documents
Type: TR-AC-01
The transformer rectifier is mounted on a 19 rack Remote Monitoring and Control Systems (RMCS)
convenient indoor or outdoor installation (depending on
type of enclosure).
All transformer rectifier control modules are provided on
printed circuit boards.
Parallel operation
Example configuration:
PROJECT MOMBASA PORT KENYA
Multiple output module TR-AC-02 with touchscreen
operation and monitoring for 48 protection areas
TRANSFORMER RECTIFIERS
Oil-cooled, Type: TR-OC-01 German Cathodic Protection
Document No.: 02-201-R1
Sheet: 1 of 1
Type: TR-OC-01
which also has a toughened glass windows for convenient meter Oil level, temperature
indicator
reading.
Test sockets are provided underneath each meter to allow for Cable conduits
independet readings using portable meters. Hot dip galvanised
steel conduits are installed on the rear for cable entry and fixing. Oil tank
The back part of the cabinet is used for the connection of surge
diverters, circuit breakers, shunts, etc. Oil drain Earthing terminal
The transformer rectifier is supplied with a base frame and valve
fixing bolts for plinth mounting. The control cabinets an also be
supplied with sunshades. Options
A transformer rectifier comprises a main transformer,
an auto-transformer or thyristor modules, a stack of selenium Corrocontrol Output Regulator (CCOR)
or silicon rectifiers and other auxiliaries/accessories such as Further technical details can be found in Chapter 10
protection devices, meters, switches, fuses, indicating lamps, Document 10-100-R0
enclosure, etc.
The transformer rectifiers are designed to meet the German The computerised output controller unit
Standards (DIN/VDE) and the Standards of the International is equipped with a programmable micro-
Electrotechnical Commission (IEC), but can also be designed processor, which controls the functions of
in accordance with other recognised Standards. the transformer rectifier.
The transformer rectifiers are built for years of rugged service. The following output control modes are
selectable by on screen user menus:
Type: TR-ACP-01
Type: CCLU-01
Description
mounting. Pipeline 3
TRANSFORMER RECTIFIERS
Residual voltage compensating unit German Cathodic Protection
Document No.: 02-150-R1
Sheet: 1 of 1
The problem of corrosion inside insulating flanges is well known. It is caused by the potential difference between the
two flange sides, for example, where oil, gas or water wells and connected flowlines are cathodically protected by two
separate systems because of different required current densities. The residual voltage compensating unit has been
developed to eliminate such potential differences at insulating flanges without reducing the efficiency of the cathodic
protection system.
Specification
RVCU-01 RVCU-01
(Residual Voltage) (Potential)
Amplifier mode :
Input voltage Ui 10 mV...5 V 5 V
Output voltage Uo 5 V 5 V
Gain max. 500 max. 1
Accuracy 0.05 % 0.05 %
10 V RTI 0.2 mV RTI
Linearity 0.02 % 0.02 % Characteristics
Drift 1 V (Offset Ui) 20 V (Offset Ui) automatic control without system deviation
20 V(Offset Uo) 20 V(Offset Uo)
insulating flange compensation to zero
1)
is determined through basic current setting
accurate potential control by potential grading
I - FLANGE
FLOWLINE
GROUNDBED GROUNDBED
PRODUCTION WELL
TRANSFORMER RECTIFIERS
Selection guide
AIR-COOLED
ENCLOSURE OIL-COOLED
EXPLOSION-PROOF
SINGLE PHASE V
FREQUENCY Hz
VOLTAGE V
DC OUTPUT
CURRENT A
STEPS No.
CONSTANT VOLTAGE
CONTINUOUS
THYRISTOR
INDOOR
LOCATION
OUTDOOR
MAX. TEMPERATURE C
MIN. TEMPERATURE C
AMBIENT CONDITIONS
RELATIVE HUMIDITY %
Selection guide
AC VOLTMETER
AC AMMETER
DC VOLTMETER
DC AMMETER
POTENTIAL METER
SYNCHRONISABLE
CURRENT INTERRUPTER
NON SYNCHRONISABLE
Zn > Cu/CuSO4
LIGHTNING ARRESTER
WITHSTAND H.V. UP TO 3 kV AC
FAILURE ALARM
DC OUTPUT
CURRENT LIMITATION
Other Requirements