INTECONT PLUS
Solids Flow Meter
Operating Manual
BV-H2219 GB
Contacts, Copyright
Service: 24h Emergency hotline: +49 (0) 172 - 650 17 00 Discontinuous Weighing Technology
+49 (0) 171 - 255 11 95 Continuous Weighing Technology
Email: service.process@schenck.net
Business Segments:
Vibrating Machines
Service Tel.: +49 (0) 61 51 32 - 10 75
Service Fax: +49 (0) 61 51 32 - 30 96
E-Mail: bvs.process@schenck.net
©Copyright 2004
SCHENCK PROCESS GmbH
Measuring and Process Systems
Landwehrstrasse 55, D-64293 Darmstadt
http://www.schenck-process.com
All rights reserved. Any reproduction of manual, regardless of method, without prior permission by
SCHENCK PROCESS GmbH in writing, even by excerpt, is prohibited.
Subject to change without prior notice.
INTECONT PLUS VDM
Contents
1. Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Power ON · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 4
LEDs · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 4
Normal Displays · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 5
Event Messages · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 6
Function Distributor · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 8
Keyboard Mode · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 9
START/STOP Feeder · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 9
EasyServe Active/Deactive · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 9
Batching Mode · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 10
Loading By Sight · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 13
Zero Setting · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 15
Read Parameters · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 17
3. Control Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
4. Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
5. Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
6. Setting Programs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Function Distributor · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 27
Calibrating Functions· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 28
TW Tare · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 28
CW Weight Check · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 29
0405
Simulation Mode · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 31
Set Time · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 31
7. Service Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
8. Parameterization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Select Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Enter Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Hardware Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Parameter Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
9. Event Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
System Message S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Electrical System E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Calibration C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Maximum H . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Minimum L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Signal Lamps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
10. Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Test Plug · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 65
11. Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Start Sources . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Batching. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Base Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Option Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Printer Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Edition : 0405
0405
0405
1. Overview
On INTECONT: For Further Reading:
Fieldbus manual BVH2220
INTECONT PLUS is designed as measuring and S5-RK512 (3964R) FH 458
evaluation system for Modbus (Comp) FH 525
O Z1 = 362.5 kg
E1 I = 1 0 0 0 kg/h
0405
gB Start/stop measurement
n Highly resolving analog-to-digital converter.
The integrated method is designed to efficiently
TU
suppress mains voltage interferences.
Preselect lower display n 16-bit microcontroller
Select functions
n
i
Unlimited storage of counter readings,
Reset counter configuration and calibration data.
B9 Enter parameters
Some Definitions:
Measuring Principle:
0405
The schematic below shows all inputs and outputs. MIN = Relay output for MIN limit value
The sample mechanical equipment presents a system MAX = Relay output for MAX limit value
equipped with crossed flexure strip.
ACK = Acknowledge event messages
O Z1 = 362.5 kg
I = 1498 kg/h
S = Measuring chute
24 V = Power supply
0405
ALARM = Relay output for ALARM
2. Control
Power ON LEDs
a
performed, followed by the display version number,
then by normal displays. (green) POWER OK
lit if all power supplies are OK.
b
Message E1
(green) CPU OK
lit if microprocessor is ready to
operate.
E1
Z1 = 2 5 0 0 kg
I = 0 kg/h X (red) ALARM
flashes if an Alarm is available.
In addition, the event code is
shown in lower display line.
X
scale. exceeded up.
WARNING: LED remains dark, symbol E1 does
not flash.
No acknowledgement required. READY: The two green signal lamps light;
Start scale manually or automatically. no Alarm is available.
0405
Upper Display
Left : Running message and operating modes. g Start totalization.
Condition : External Release signal
Rotating point indicates that totalization
and material prefeeder are active. available (selectable).
START_Source (B03) set
Right : Totalizing counter 1 to OP or Keyboard mode
active.
Operating Modes
Feature : Rotating point in left field
of upper display
B Stop totalization.
Feature: points stands still
Measured load continues being acquired.
f Acknowledge input.
Lower Display
N Delete faulty digits.
Left
Right
Event reported by alphanumeric code,
e.g. E1 for power failure.
Selectable
TU Select lower display
(see Normal Displays).
TU Select display
O Acknowledge event message.
Definitions Acknowledgement:
Not required.
All important scale functions are internally monitored.
Errors are reported by event message. n IGNORE No monitoring of events, save
MIN/MAX messages and deviation
For troubleshooting details, see chapter “Event via contact outputs and signal
Messages”. lamps.
Operation
n ALARM Display flashing and underscored. TU Scroll “Display Events” into lower display
X
field (normally not required).
In addition, red signal lamp
flashes. f Select function.
Totalization cuts off, scale is not
operable.
Start:
First remove cause of fault and
acknowledge message.
Acknowledgement:
If cause has not been removed
yet, flashing stops, underscores
are deleted, but message is still
available.
If fault is remedied after
acknowledgement, message
automatically effaces.
Acknowledgement:
If fault has not been remedied yet, 0405
underscore is faded out.
I = Feed rate
L/C = Load cell
1. Events S 2 = M06
No Release
* fault in device or cabling
Maximum H H1 I >MAX
H4 L/C Input > MAX
Abort Batch
function selected last. If an event is Deselect Batch
available, the “Display Events” function is Batch Number
displayed. Print Batch
f Start function.
Reload
Function
With opposed functions, e.g. START/STOP, only the
Display Events one currently availabe can be reached.
G
Service Values
START/STOP KEYB. MODE Call Display Check function.
TU
Select Batch B 1. All display elements rhythmically
EasyServe active/deactiv flash.
>0< Zero Set
f
2. Version number is displayed for
Programming approx. 10 s.
Calib.Functions S Test terminates automatically.
Print FMZ
Read Parameters
Enter Parameters S
Load Default Par. S INTECONT PLUS
Print Parameters VDM 20600-00 2063
Print Stat. Rep.
START/STOP Simulation
TW: Tare Example:
CW: Weight Check
Set Time VMD : Solids Flow Meter
20600-00 : Version number
0405
This function lets you shift the selected control source The “EasyServe Active/Deactive” functions let you
for START/STOP to the INTECONT keyboard. control your INTECONT using the EasyServe PC
After deselection of Keyboard mode, the former service tool.
source is active again.
Upon changeover from external source (e.g. serial) to
keyboard, START/STOP status is maintained. GT Call function distributor.
Select “EasyServe Active” function
In reverse direction, the external signals are active.
GT
To set communication parameters, use
Call function distributor. Block Q.
Select “START Keyboard Mode” or
“STOP Keyboard Mode” function.
Note: Upon power failure, the current status is
stored, i.e. “EasyServe Active” function
Display feature: needs not be re-called.
You will know Keyboard mode by the square in the left Connection to PC can also be made using a 9-pole
upper display field. SUB-D connector on X4 (RS 232 only) or a Phoenix
connector on X5 (RS232, RS422 or RS485).
See also Wiring Diagram in chapter DETAILS.
START/STOP Feeder
f Start function.
0405
1. Zb = Batch setpoint
Batching Mode
2. ZI = Batch actual value
Batching mode is used to feed a defined amount of (amount already
material. When batch setpoint is reached, batching discharged)
operation is complete.
TU
Lower display:
Use cursor keys to scroll 3
additional values into display field. 0405
P
command.
Prepare setpoint input.
Deselect Batch
19 Enter setpoint.
Max. 9 digits including decimal point.
Lets you deselect Batching mode, i.e. mode is removed
from available functions.
The unit is that of Counter 1. Totals sign Σ disappears from upper display, batching
f
values ZI, Zd, Zb and Nb are not longer available but
Acknowledge input. remain stored.
f
Select “Deselect Batch” function.
Acknowledge.
O
batching mode.
Delete faulty digits. The old ZI, Zd , Zb and Nb values can be viewed
again.
0405
f Acknowledge.
in lower display.
Reloading operations belong to previous batch and
are not counted.
You can also abort batch using contact O02.
f Acknowledge function.
System prompts for input of reload
setpoint in kg or t.
The unit is that of counter 1.
Batch report can be printed only if a batch is complete The printing functions require an option card to be
(setpoint reached). present.
1. Call “Select Batch” function. Start of printout disables the “Reload” function for the
2. Select very high batch setpoint, e.g. 999999999 kg. batch in question.
Function can be called only in Batching mode.
3. Scroll batch actual value ZI into lower display field.
4. Start scale. Printing can be started:
5. If amount ZI is reached, stop scale.
6. Call “Stop Batch” function. 1. Manually via function distributor
7. Start printing (see “Print Batch”). 2. Automatically, after each complete batch
(Parameter I 06).
The “Reload” function can be performed only before
print command. GT Call function distributor.
Select “Print Batch” function.
For next batch, follow steps 4...7.
f Start function.
N Abort printing.
Batch Report
07.07.03 11:45:10
Events
E1 Power Failure M01
0405
Print Parameters
Lets you print out parameter list complete with current L1 : Event code
values. W1 : Message class, e.g. WARNING 1
Parameter values varying from default settings are
−> : Event has occurred
cross-marked (*).
As Appendix, a list of possible events and current <— : Cause removed; event
hardware assignment is printed. acknowledged, if required.
I < MIN : Explanation
f
available.
Start function.
For details, see “Event Messages”.
N Abort printing at any time.
Status Report
PRINT PARAMETERS
Printable at any time, the status report includes most
INTECONT PLUS VDM 20600-00 2063
significant status values and event messages output
03.06.03 7:39:25 after last printout. If status is printed for the first time,
counting starts from last power-on of INTECONT.
BLOCK A Scale Definitions
GT
01 Language ENGLISH
02 Units SI
Call function distributor.
BLOCK B Rated Data Select “Status Report”.
f
01 Feed Rate Unit ——— kg/h
02 Nominal Feed Rate * 1,000 t/h
usw.
Start function.
Voltage ON-time
Total voltage ON-time
Zero Setting
Scale ON-Time The zero setting program lets you acquire the
Total ON-time of measurement and INTECONT measuring system’s zero point error over a settable
time.
Events after last status report The acquired value is used to correct the current
Number and type of events since last report printout. measuring result during operation.
If report is printed for the first time, counting starts
from power-On. Effects:
G
Voltage ON-time : 35 h
Scale ON-time : 23 h
Counter 1 : 5635 kg
Counter 2 :6t Call function distributor.
Counter 3 :6t
-----------------------------------------------------------
Events after last status report
2 * S02 No Release
TU Scroll >0< (zero set) into lower display
field.
f Start function.
0405
0o Dev. 2.45%
Tarkor 3.50 %
Program Complete:
0405
Read Parameters
f
display field and acknowledge.
Scale Definitions
Block: A
N Return to blocks.
0405
0405
3. Control Overview
O Z1 = 362.5 kg
-- I = 100 kg/h
Control Keys:
T
1. Counters Z2, Z3 4. Measured load Q
2. Feed rate I 6. Batch displays Zb, ZI, Zd, Nb, Zbn, Zdn
3. Feed rate Ir in %
0405
Lower display field shows event message, if any, e.g. symbol S2 = No Release.
List of Events
Maximum H1 I >MAX
H4 L/C Input > MAX
I = Feed rate
L/C = Load cell
0405
4. Technical Data
n Panel-mounting unit: VEG 20600/20610 n Surface-mounting unit: with panel mounting unit
Front panel 96 x 288 mm: VEG 20...
Panel cut-outs : 88 x 282, wall thickness
max. 10 mm n Wall-mounting housing
Mounting depth : min. 225 mm
(including 50 mm for Measuring
connectors) systems : width x height x depth
Protected to : IP 20, front to IP 65 410x330x236mm
Material : plastic grey to RAL 7022 Feeding
systems : width x height x depth
Display : fluorescent, 2 lines of 20
500x600x300mm
characters, 6 mm high
Protected to : IP 65
Keyboard : flexible membranes with
tactile touch Material : steel sheet, 1.5 mm, grey
Voltage supply : 90...264V/50Hz...60Hz
Signal lamps : LEDs, 2 x green, 3 x red
Power supply : 24 V(DC) +50 % -25%, Extension : Feed unit controller
max. 1 A,
n Environment
no fuse, pole-reversal
protective circuit Temperature : -25 °C ... +45 °C,
Ext. power supply : 90...264V/ 50HZ...60HZ tested to -40°C
Humidity : Class F (DIN 40 040) *
Interference
immunity : to IEC 801
Interference
P = 100.00 kg/h suppression : to VDE 871, EN 55 011
I= 0 kg/h
Housing safety : to IEC 348
EC recommen-
dations : CE label
n Storage temperature
n Connectors
n Control outputs
Number :
8 N/O relay contacts
Base board 3:
Option card 5:
Load :
max. 230 V(AC)
8 A resistive load, 1 A
inductive
0405 If error message “CPU Not OK” is output, all contacts
open.
Number : 5 Number : 1
Base card : 3 Current : raise ...20 mA impressed
Option card : 2 Raise : 0... 20 mA
Type : 24 V(DC) +/-30 %, 5 mA, Load : 500 ohms
galvanically isolated Reference : 0 V internal,
galvanically non isolated
Resolution : 10 bits +/- 1/2 d
n Control inputs (NAMUR) Acuracy: <0.4% over entire
temperature range
Number : 2
Type : NAMUR (DIN 19234),
short-circuit and cable n External totalizing pulse counter
breakage monitoring
Frequency : max. 10 Hz
Pulse length : selectable 50...1000 ms
Output : 24 V, max. 100 mA
optionally active low or
active high,
galvanically isolated,
n Analog output
short-circuit-proof, limited to
Number : 2 apr. 350 mA,
Base card : 1 negative amounts are stored
Option card : 1 internally and must be
compensated by positive
Current : raise ...20 mA impressed
amounts before new pulse is
Raise : 0... <20 mA
output.
Load : max. 500 ohms
This ensures integral
Reference : 0 V by user, accuracy also with minimal
galvanically isolated belt load.
Resolution : 12 bits +/- 1 d
0405
Number : 1
Type : RS232; RS422 or RS 485
max. 19200 baud
Data format : 8 data bits, 1 stop bit, odd
parity changeable to even or
no
Isolation : galvanically non-isolated
Connectors : Phoenix MSTB, contact
spacing 3.5 mm, max. 1.5
mm2 or 9-pole D-Sub HD20
0405
0405
5. Characteristics
Scale data, calibration values, counter readings and Upper display : Totalizing counter 1
pulses pending remain stored after power failure for Lower display: Totalizing counters 2...3
an unlimited period of time. The internal clock Feed rate absolute I
continues running for approx. 5 days. Feed rate relative Ir
Measured load absolute
Measured load relative
Batch data
n Dialog Language
for error messages, operation, and service Select lower display using cursor keys.
programs.
Eligible : DEUTSCH
ENGLISH n Signal Lamps (top down)
FRANCAIS
ESPANOL VOLTAGE OK (green)
ITALIANO PROCESSOR OK (green)
ALARM (red)
MIN (red) feed rate MIN limit
MAX (red) feed rate MAX limit
n Units (selectable)
0405
Zero setting is performed by an automatic program. Calibration as such is not required. All you have to
No material is required. do is enter some constructional data of load cells,
Program can be started speed transducer, belt inclination, etc. INTECONT
uses these data to compute all requisite display
1. manually via keyboard normalisations.
2. automatically with closed prefeeder Check, or recalibration, can be effected in two ways:
n Digital Outputs
n Maintenance Hints
Nummer Name Default
through display of event s
P04 DO I-MIN D01
1. Voltage ON-time P05 DO I-MAX DO2
2. Scale ON-time P01 DO ALARM D03
P02 DO Prefeeder ON D06
P03 DO Feeder ON D05
n Adaptions P07 Full Feed —-
P08 Dribble Feed —-
The electrical system needs not be redesigned nor P06 DO Batch Active —-
adapted.
0405
6. Setting Programs
Function Distributor Programming and Calibration functions lead to further
menus you can move through using cursor keys.
The function distributor lets you call further functions
and/or dialogs. B = If Batching mode is selected, additional
functions can be accessed in main
G
distributor.
Call function distributor.
If an event is available, “Display Events” Abort Batch
is displayed; if no event has occurred, Deselect Batch
display shows function selected last. Batch Number
f
Print Batch
Start function. Reload
N
S = Calibrating functions protected by
Return to normal displays, or abort password. Prompt for password input is
function. output after call of function.
E = If an event is available.
Display Events E
Display Check
START/STOP Feeder
Service Values
START/STOP Keyb. Mode
Select Batch B
EasyServe active/deactiv
>0< Zero Set
Programming
Calib.Functions S
Print FMZ
Read Parameters
Enter Parameters S
Load Default Par. S
Print Parameters
Print Stat. Rep
START/STOP Simulation
Tare
CW: Weigh Check
0405
Set Time
Menu item “Calibration Functions” lets you access 3 The taring program acquires zero point error of
functions: complete measuring system over a settable time
(Parameter C 01, default = 30 s).
1. TW Tare INTECONT uses this value to correct measuring
2. CW: Weight Check result during operation.
2. Set Time In contrast to zero setting program, zero setting range
is not monitored nor limited.
All functions are protected from unauthorized use by Taring program deletes the zero setting result.
password.
The operating sequence is the same for all programs.
TUf
2. Analog output is set to
Scroll CALIBRATION elevation value.
FUNCTIONS into lower display 3. Events continue being
field and acknowledge. monitored.
Display shows one of the setting programs, e.g. TW: Follow these steps:
Tare.
Gf Function distributor, Calibration functions,
password (see “Calibration Functions”).
TU
CALIBRATION FUNCTIONS
TW: Tare
Scroll “TW: Tare” function into lower
display field.
f Start function.
0405
Program running:
CW Weight Check
Conditions:
>0< Dev. 2.45 %
Tare 3.50%
1. Taring or zero setting performed
2. Effective check weight entered into Parameter C 05
3. Check weight applied in provided point
4. Scale cut off
Upper display : Deviation of tare value from
previous taring operation
in % of nominal measured load Sequence:
Lower display : Mean value of total tare TU Scroll “CW: Weight Check” into lower
display field.
in % of nominal measured load
f
f
Start program.
Accept taring result and enter value into
Parameter D 04.
Tare correction (D05) is set to zero.
N Abort at any time
Special Messages:
0405
Lower display : Continuously meaned SET/ACT Error > 5 % : COR < 0.95 or COR > 1.05
measuring result Multi-percent deviations suggest
wrong data input (e.g. belt
inclination not exactly known, lever
arms) and/or mechanical faults
Program complete (misalignment, distorsions).
C05
I = D02
Upper display : ACTUAL measured load in kg C04
Lower display : Mean value COR of SET/ACT over
total run time
I = Feed rate in t/h
C05 = Check Weight in kg
C04 = Device Constant in kg/(t/h)
D02 = Weight Correction
fN Exit program.
Since result is not acquired automatically,
the two keys are equivalent.
Special hints:
0405
Simulation Mode lets you check all scale functions Unlike the other programs, date and time can be
without material at the time of commissioning. changed in Start and Stop states of scale and be read
During simulation, scale is cannot operate in normal off under SERVICE VALUES.
mode.
TU
password (see “Calibration Functions”).
TU Scroll “Set Time” into lower display field.
f
Scroll “Start Simulation” into lower display
field. Call menu.
Display :
Event message S7
In upper line, “=” symbol
0 3 Enter year, e.g. 03, month, day, hour,
minute, and second.
flashes.
Function can be cut off in the same way (STOP
Simulation). f Acknowledge every input.
When seconds have been
acknowledged, new date is acquired.
0405
0405
7. Service Values
The Service table includes detailed system 6. Inputs switching conditions
information. Call does not affect weighing functions.
I+ : DI = 1 1 1 1 1 + 0
Displays: 7. EL = 22 h
Scale On-time
O Z1 = 1500100 kg
Opt..IND : 1
Condition : Totalization ON
Monitoring : Parameter K 03, Message
S3
0405
14. ZE = 53
15. ZO = 1
Pulses still to be output.
If value keeps exceeding zero, pulse
frequency is higher than 10 Hz.
Increase weighting of smallest display digit of
Counter 1 (Parameter B 10).
16. AI = 12.54 mA
17. CS = 10851
0405
8. Parameterization
Display units and format Let you select from various options, e.g. WARNING,
Limit values ALARM.
Nominal and calibration data, etc.
Numeric parameters
Some parameters can be set in accordance with
requirements (e.g. display formats), others have to be
taken from Spec Sheet supplied. Enter numeric value, e.g. nominal feed rate.
During parameter input, all functions are maintained.
However, during operation, only parameters with no
influence on measurement, e.g. display filters, should
be changed.
Call Parameter Menu
Bf
Identification
Enter password 07734.
The parameters are organised into function blocks A,
B, ... and, within a block, described by
TU Selection parameter:
value flashes.
Rated Data Scroll desired value into lower
Block: B display field.
B9 Numeric parameters:
TU Move through blocks A, B ... up
and down.
Feature - - - - - - - - - - - - - - - -
Enter value using number keys.
f
Block letter flashes.
f Select block.
Acknowledge input.
Next parameter is displayed.
O
Display shows parameter
selected last. Delete digits.
0405
OP
G Select PROGRAMMING function,
call DEFAULT PARAMETERS.
v
—
B1 YES = 1
NO = 0
DI I+ DI1-DI7 HI, LO
AI I+
Power Failure
As you can see, with “Fieldbus” (FB), “Operator
Panel” (OP), “Speed” (v) and “Not Assigned” (—) no Parameters remain stored for an unlimited period of
additional input is required. time.
“Digital Inputs” (DI) and “Digital Outputs” (DO) require
unit, channel and level to be indicated.
With “Analog Input” (AI), the unit is firmly set to I+.
Sample:
Description Source
B06 START Source OP
Alternatives FB, DI
6
right) let you shift between source,
channel and level.
0405
This list applies to software: VDM 20600-00 01 Value for I-MIN 5.0 % Io
02 Event Class I-MIN W1 (L 01)
BLOCK A Scale Definitions 03 Value for I-MAX 120.0 % Io
04 Event Class I MAX W1 (H 01)
01 Language * ENGLISH
02 Units SI
BLOCK G Filter Setting
0405
BLOCK N Linearization
01 Linearization ON NO
02 Lin.-S1 25.00 % Io
03 Lin.-I1 25.00 % Io
04 Lin.-S2 50.00 % Io
05 Lin.-I2 50.00 % Io
06 Lin.-S3 75.00 % Io
07 Lin.-I3 75.00 % Io
08 Lin.-S4 100.00 % Io
09 Lin.-I4 100.00 % Io
10 Lineariz. error W2 (B 09)
0405
A 01 Language A 02 Units
Range: SI Default: SI
Range: DEUTSCH Default: DEUTSCH
NON-SI
ENGLISH*
AMERICAN ENG*
FRANCAIS Lets you change over displays and parameter inputs
ESPANOL from SI units to American units.
ITALIANO
Selection holds for all displays, event messages and
American Unit SI Unit Conversion *
parameters. lb kg 1 lb = 0.453593 kg
t t 1 t = 0.907185 t = 2000 lb
* identical f m 1 f = 0.3048 m
inch cm 1 inch = 2.54 cm
0405
Note
0405
PNENN = nominal
n feed rate in kg/h or t/h
Zmin = smallest display digit of counter 1
(B 04) in kg or t
0405
Measuring time for taring and zero settings programs The check weight is used to check weighing system
using calibration program “CW: Weight Check”.
C 04 Device Constant
Range: 0.00100...1.0 kgh/t Default:
0.04 kgh/t
Q kg
GK = in
I t/h
0405
Nominal measured load serves as reference for limit Result of taring program
values and zero setting programs.
Attention!
If you enter Parameters D 02 ... D 05 in manual, enter
D 02 first.
0405
E 01 Source AO 1
Range: I (feed rate) Default: I
Q (measured load)
X = I, Q Xnom = nominal value
Note:
One of these values can be output in analog fashion.
1) Maximum output current is 20 mA.
Filters: Parameters G 02, G 04 2) Minimum output current corresponds to elevation E
02.
3) In Stop state of scale, output for I is set to elevation
value; for Q, measurement value is output.
E 02 Elevation AO 1
Range: 0.00...20.00 mA Default: 4.00 mA E 04 Source A02
Output current of 0% value I, or Q. Range: I (feed rate) Default: Q
Q (measured load)
E 03 Limit Value AO 1
See Parameter E01
Range: 0.00...1000.00 mA Default: 20.00 mA
E 05 Elevation A02
Range: 0.00...20.0 mA Default: 4.00 mA
X
i = ELEV + (END - ELEV)
Xnom
0405
0405
Feed rate display During specified time, totalization goes on after scale
stop.
G 03 Q Display
Range: 0.0...600.0 s Default: 3.0 s
G 04 L/C Filter
Range: 0.0...600.0s Default: 1.0 s
0405
No display feature.
0405
If batch setpoint (I 01-I 02) is reached, dribble feed Pre-cut-off amounts I 01 and I 02 are adapted
output (P08) is set. automatically so that the system better fits the
Signal can be used, e.g. to reduce prefeeder rate. situation upon next batch.
If batch setpoint has reached pre-cut-off amount I 02, Intermediate values cause a filtered adaption which is
batching terminates and prefeeder stops. preferable in plants with unprecise repeatability
behaviour.
I 04 Batch Tolerance
Range: 0.0...2200000.0 kg Default:
100000.000 kg
I 02 considers material afterflow, if any.
Related to batch setpoint
I 05 Out of Tolerance B1
Range: WARNING 1 Default:
WARNING 2 WARNING 1
ALARM
IGNORE
I 06 AUTO Print
Range: NO Default: NO
YES
06.03.03 16:20:16
Batch Setpoint 200 kg
Batch Actual Val. 205 kg
Counter 1 31779 kg
Counter 2 32 t
Batch-Number 6
I 07 Batch Source
Range: OP
FB Default: OP
0405
0405
0405
L 07 Physics
L 03 Comm. Error Host S9
Range: RS232 Default: RS 485
Range: IGNORE Default: IGNORE RS 422
W1 (WARNING 1) RS 485
W2 (WARNING 2)
A (Alarm) Sets interface physics for Modbus
0405
L 11 Physics L 16 Configuration
Range: RS 232 Default: RS 422 Range: FIXED-1 Default: FIXED-1
RS 422 FIXED-2
NO-PARA-ID
PARA-ID
Sets interface physics for S5 protocol
0405
L 19 Configuration
Range: FIXED-1 Default: FIXED-1
FIXED-2
NO-PARA-ID
PARA-ID
L 20 Byte Sequence
Range: LOW-High Default: LOW-High
High-LOW
L 21 Word Sequence
Range: I: std/L:std Default: I: std/L: std
I: swp/L: std
I: std/L: swp
I: swp/L: swp
0405
Block M: Events
Exception:
IGNORE always releases scale.
0405
Block N: Linearization
N 01 Linearization ON N 06 Lin.-S3
Range: NO Default: NO Range: 0.10...1000.00%Io Default: 75%Io
YES
Linearization point 3:
This function lets you linearize feed rate
measurement. See N 02
The 4 linearization points can be determined through
checks using material. Place points not needed, or
measured, outside the measuring range or interpolate.
N 07 Lin.-I3
N 02 Lin.-S1
Range: 0.1...1000.0%Io Default: 75%Io
Range: 0.10...1000.00%Io Default: 25%Io
Linearization point 3:
Related to nominal feed rate B02
See N 03
Linearization point 1:
O 01 Release
Range: DI Default: DI (DI2)
—
O 02 DI Stop batch
Range: DI Default: —
—
O 03 DI Ackn. Events
Range: DI Default: DI (DI1)
—
O 05 DI Ext. Event
Range: DI Default: - -
—
0405
P 01 DO Alarm Q 06 DO I-MAX
Range: DO Default: DO (DO3) Range: DO Default: DO (D02)
— —
Digital output used to report general alarm Digital output signal used to report that maximum feed
rate (F03) is exceeded up.
Contact output is independent of event class (F04).
P 02 DO Prefeeder ON
Range: DO Default: DO (DO6) P 06 DO Batch Active
—
Range: DO Default: —
Digital output used to START/STOP prefeeder —
0405
Q 02 Physics
Range: RS 232 Default: RS 232
RS 422
RS 485
Physics of data transmission protocol
Q 03 EasyServe Baudr.
Range: 9600 Default: 19200
19200
0405
9. Event Messages
0405
Calibration C Maximum H
Minimum L
L1 : I < MIN
0405
Action:
see L1: I<MIN
Action:
see H1: I>MAX.
No power supply:
0405
0405
10. Commissioning
Test Plug
1. wz apr. 1.1mV/V
2. Load cell apr. 50 % (C02 =2mV/V)
utilization aw apr. 35% (C02 =2.85mV/V)
Note:
With different R1 and R2 resistance values, the
following raw measured value results:
0405
0405
11. Details
Start Sources
Sources
START/STOP Synchronization
The “Start/Stop” functions can be started from different
control sources preselected via parameters. Upon changeover from external setpoint source or
The “Keyboard Mode” dialog function lets you shift keyboard, external setpoint is acquired. In reverse
from preselected sources to keyboard and vice versa. direction, the external source is active.
Parameter:
0405
Control Inputs/Outputs
Operating Sequence
0405
Batching
Principle: Sequence:
When batch is complete, material prefeeder cuts off. 0 Start batch using Start command.
Changeover from full feed to dribble feed can be Prefeeder and totalizing counter start operating.
effected using prefeeder speed or opening angle. . 1 Stop batch using Stop command.
Measurement continues for time G 05.
Output signals (Batch Running, Full Feed, Dribble 2 Continue batch using Start command.
Feed) can be placed on free output contacts, if
required.
0405
5 Material afterflow
Power OFF:
If parameters A and F are properly set, defined
setpoint is exactly reached.
Batch aborts, batching mode remains selected.
If note, see “Adaption”.
All counter readings and amounts batched are stored
for an unlimited period of time.
Next Start command starts new batch.
Adaption:
DI Complete Batch:
0405
0405
GK indicates the correlation of load cell load and feed The CW calibration program compares the effective
rate and thus determines calibration accuracy. check weight entered (load on load cell through check
weight) with measured load cell load.
GK = QNOM / PNOM
Ua = Ue x WZKENN x (F / WZF0)
Ua Output voltage in mV
Ue Input voltage in V
0405
Wiring Diagram
Base Card
0405
0405
Option Card
0405
Option Card:
Printer Connection
Interface : Serial, see “Technical Data”. Switch
Cable : The connection diagram refers to 1-1 : OFF 8-bit message
EPSON and CITIZEN printers. 1-2 : OFF No parity bit
1-3 : egal Even/odd
1-4 : OFF Postive edge
1-5...8 : OFF, ON, OFF, OFF 9600 baud
2-1...6 : ON, ON, OFF, OFF, OFF, OFF
(default)
Switch
EPSON printer: LX 850 1-1 : OFF 10 CPI character spacing
1-2 : OFF Zero without backslash
1-3 : ON Graphics character set
1-4 : OFF AUTO hyphenation activated
1-5 : ON Normal sprint speed .
1-6...8 : ON, ON, ON USA
2-1 : ON 12" page length
2-2 : OFF No single sheet
2-3 : OFF Jump over performation
2-4 : OFF No AUTO line feed
To initialize:
Fig. Serial Interface
Printer is initialised via serial interface, 5s after
power-up of INTECONT PLUS.
0405
0405
The FIP base and option cards connection diagrams Load Cell
indicate for every digital input and output the relevant
INTECONT VEG parameter numbers used for FIP Physical Signal VEG
distribution on physical signals.
X5 3 OUT1 X7 3
The tables below compares the connector X5 4 REF1 X7 4
assignments of FIP and VEG for all physical signals. X5 5 IN2 X7 6
X5 6 IN1 X7 5
Digital Outputs X5 7 REF2 X7 7
X5 8 OUT2 X7 8
FIP Physical Signal VEG
—- AI X6 1,2,3 X9 5 24V X6 8
X9 6 Open collector X6 9
X9 7 Open emitter X6 10
X9 8 0V X6 11
0405
Connector Size
FIP
VEG
0405