You are on page 1of 1

QA.

01
S.V. ENGINEERS
Plot No: 11/A3,IDA,PATANCHERU
DIMENSIONAL INSPECTION REPORT
CUSTOMER : NUCLEAR FUEL COMLEX DRG.No. :SVE/1714/01 Rev-01
P.O.No. : W.O.No. : SVE/NFC/1714
FURNACE RAIL TEMPLATE FOR ARC REP.No. : SVE/QCA/1714/DIR-01
EQUIPMENT :
RE-MELTING FURNACE DATE : 25-12-2017
PART NAME : Curved Rail Bar INSP. AGENCY: CUSTOMER

Sl.No Description Actual Dimensions Required Dimensions Qty

PART NO:10 1
1 ID 2555 2555
2 OD 2805 2805
3 OCF 5091 5095
4 Width 250 250
5 Thickness 25 25
6 Inside PCD 5140 5140
7 Outside PCD 5550 5550
8 Hole dia M12 M12
PART NO:11
1 ID 2560 2560
2 OD 2710 2710
3 OCF 8655 8658
4 Width 148 150
5 Thickness 65.5 60

Remarks:
1. Visually checked found satisfactory.

2. All dimensions are in mm unless otherwise specified.

For S.V.ENGINEERS For INSPECTION AGENCY

ENGINEER (Q.C.) DATE