You are on page 1of 2

Laboratory Accredited v2 CIVIL DIAGNoSTICS PRIVATE LIMITED

Quolily Tesling Services


TC-5255 as perISo/IEC 17025

ULR-TC525522000000550F
TEST REPORT NO. & DATE v2CD/LAB/2021-22/V2CD12009.13/7943
24/01/2022
1. Name & Address of Customer
M/s. L&W Construction Pvt.Ltd
#801,8th Floor, Pride Hulkul Building
No.116, Lalbagh Road, Bangalore-27
2. Project / Site White Alpha
Bangalore.
3. Customer's Reference Letter Did.20.1.2022
4. Sample
i) Description HSD steel bars
ii) Quantity o5 Sets
ii) Date of receipt 20/01/2022
iv) Condition Acceptable
Test method followed, if any IS.1608, IS.1599, 1S. 1786.
6. Date of Testing 21/01/2022
TEST REPORT
LMECHANICALTESTING
a) .Mechanical Properties of Metals

TENSILE TEST:
IDENTIFICATION MARK JSW Fe-550D I.S.1786

21D52900000 Requirements
# Heat No.
|21VJ2900381 21VJ2900381 21VJ2900390 21VJ2900381
Fe-550D
097 097 379 408 835
8.00 10.00 16.00 20.00 25.00
DIAMETER (mm)
AREA (mm) 49.81 77.20 196.43 311.85 487.13
GAUGE LENGTH (mm) 39.88 49.64 79.19 99.77 124.70
YIELD LOAD (N)_ 31500 48200 121900 199200 314300
ULTIMATE LOAD (N) 37000 54900 140700 233500 372100
FINAL LENGTH (mm) 47.40 59.00 95.00 118.00 147.40
632.42 624.37 620.57 638.77 645.20 550 min.
a. YIELD STRENGTH- N/mm?
b. ULTIMATE TENSILE a+ 8%
742.84 711.16 716.27 748.7 763.86 600 min.
TRENGTH (N/mm)
% ELONGATION 18.87 18.85 19.971 18.27 18.20 14.5min.
FRACTURE W.G.L. W.G.L. W.G.L. W.G.L. .G.L.
WEIGHT PER METRE(kg/m) 0.391 0.606 1.542 2.448 3.824
BEND TEST : ANGLE OF BEND - 180°

RESULT PASS PASS PASS PASS PASS


ANGLE OF BEND 135 ANGLE OF REBEND 157.5°
REBEND TEST:
RESULT PASS PASS L PASS PASS PASS
NOTE PAV2 CIV
# Data furnished by customer.
1 evEFDB
Signatoryo

nrak
Page No: 1 of1
Engi
OLTW 1YAT
eAER-Q
153/2, Lower Ground Floo&-2hd Floor,
MRB Arcade, Bagalur Main Road,
IAF Post, Yelahanka, Bengaluru - 560 063

Note
his oertificate should not be reproduced in part, without the permission of this laboratory Off: +91 9108032565 / 66
This certificaterefers onlytothe samplegubmitted for testing & applicable parameters. Cell: +91 90350 13476
/3.
Any corrections invalidates thie certificate e-mail: info@civildiagnostics.com
4 Sample wll be disposed after15davsfrom the date of issue of test certificate, unless otherwise specified. Web: www.civildiagnostics.com
v2 CIVIL DIAGNOSTICS PRIVATE LIMITED
Laboratory Accredited Quality Testang Services
TC-5255 as per ISO/IEC 17025

ULR- TCS25522000000559F
TEST REPORT NO. & DATE V2CD/LAB/2021-22/v2CDI2014-12018/7957
25/01/2022
1. Name& Address of Customer M/s. L& W Construction Pvt.Ltd
#801, 8th Floor, Pride Hulkul Building,
No.I 16, Lalbagh Road, Bangalore - 27

2. Project /Site White Alpha


Bangalore.
3. Customer's Reference Letter Dtd.20.01.2022
4. Sample
i) Description Plain Carbon & Low Alloy Steel
ii) Quantity 05 Nos
ii) Date of receipt 20/01/2022
iv) Condition Acceptable
5. Test method followed, if any IS 8811-1998
6.Date of Testing 21/01/2022
TEST REPORT
LCHEMCALTESTING
a) .Building Material

# DC No Carbon Sulphur Phosphorus Sulphurand


SL
ID. Mark Dia mm %
Phosphorus
Reference No. % % %
No.

21VJ2900381097 8.00 0.20 0.014 0.023 0.037

21VJ2900381097 10.00 0.21 0.028 0.019 0.047


2

JSW Fe-550D 21VJ2900390379 16.00 0.19 0.025 0.010 0.035


3

4 21VJ2900381408 20.000.19 0.19 0.022 0.023 0.045

21D52900000835 25.00 0.190.023 0.010 0.033

per IS: 1786 2008


permissible limits as
-

Maximum
Fe415 0.30 0.060 0.060 0.110
Fe 500 0.30 0.055 0.055 0.105
Fe 500 D 0.25 0.040 0.040 0.075
Fe 550 D 0.25 0.040 0.040 0.075
0.050 .100
|Fe5500.30 0.055
Note
#Datafurnished by customer. sOSTIC
RIVAT t EvIEWED y

Ahoried Signtary
/
Nishw
SRER-6SA/M
Page No:1 of1 AnalChemicalSeehon
Bang
elahan
ank 153/2, Lower Ground Floo &2nd Floor,
MRB Arcade, Bagalur Main Road,
IAF Post, Yelahanka, Bengaluru - 560 063

Note
his certificate should not be reproduced in part, without the permission of this laboratory Off: +91 9108032565/66
nis certificate refers only to the sample'submitted for testing &applicable parameters. Cell: +91 90350 13476
3.
Any corections invalidates thie certiticate. e-mail: info@civildiagnostics.com
4Sample will be disposed after 15 days from the date of issue of test certificate, unless otherwise specifled. Web: www.civildiagnostics.com