PRELIMINARY
Title page
Alcatel-Lucent 9311
Macro V1 Node B Outdoor with 9926 d4U
Maintenance Guide
3MN-00475-0006-REZZA
Issue 1.03 | June 2013
PRELIMINARY
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Use pursuant to applicable agreements
Legal notice
PRELIMINARY
Legal notice
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright © 2013 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside
Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.
PRELIMINARY
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Contents
PRELIMINARY
About this document
Purpose .......................................................................................................................................................................................... xiii
xiii
Prerequisites .................................................................................................................................................................................. xv
xv
1 UTRAN introduction
2 Safety statements
....................................................................................................................................................................................................................................
4 Corrective maintenance activity
Hardware presentation for 9311 Macro V1 OD with d4U digital shelf configuration .................................... 6-2
6-2
....................................................................................................................................................................................................................................
iv Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Contents
PRELIMINARY
....................................................................................................................................................................................................................................
Replacing the 9926 d4U digital shelf equipment
Replacing the Direct Ambient Cooling System (DACS) of the 9311 Macro V1 OD ................................. 10-55
10-55
Replacing the iDACS control board of the 9311 Macro V1 OD ........................................................................ 10-61
10-61
Replacing the iDACS air filter of the 9311 Macro V1 OD .................................................................................. 10-68
10-68
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary v
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Contents
....................................................................................................................................................................................................................................
Replacing the DC Breaker Panel ................................................................................................................................. 10-105
10-105
Replacing the Manufacturing Commissioning and Alarm (MCA) module of the 9311 Macro V1
OD ................................................................................................................................................................................... 10-114
10-114
Replacing the Pulse Code Modulation (PCM) protection module of the 9311 Macro V1 OD ............ 10-121
10-121
9311 Macro V1 OD with d4U: Replacing the double TMA module .............................................................. 10-123
10-123
9311 Macro V1 OD with d4U: Replacing the light TMA/AISG TMA module ......................................... 10-128
10-128
Replacing the Interconnection Module of the 9311 Macro V1 OD with d4U Node B ............................ 10-134
10-134
Replacing the anti-sliding strips of 9311 Macro V1 OD cable cover ............................................................. 10-137
10-137
Index
....................................................................................................................................................................................................................................
vi Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
List of tables
PRELIMINARY
1 Issue 1.03, June 2013, Reason for reissue ........................................................................................................ xiv
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary vii
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY List of tables
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
viii Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
List of figures
PRELIMINARY
1-1 Alcatel-Lucent UTRAN architecture example ............................................................................................... 1-4
8-2 DC Breaker Panel used with the d4U Node B configuration .................................................................... 8-4
8-5 DC Breaker Panel used with the d4U Node B configuration .................................................................... 8-8
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary ix
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY List of figures
....................................................................................................................................................................................................................................
10-9 Location of optical connectors in the 9926 d4U Node B ....................................................................... 10-20
10-10 9926 d4U Node B fan rack module view .................................................................................................... 10-24
10-21 Location of the iDACS control board in the 9311 Macro V1 OD ...................................................... 10-63
10-22 Location of the connectors of the iDACS control board ........................................................................ 10-64
10-26 Location of the dc power system shelf in the 9311 Macro V1 OD .................................................... 10-73
10-27 Front view of the single phase filtering box ............................................................................................... 10-76
10-28 Front view of the split-phase filtering box (US) ....................................................................................... 10-77
10-31 Location of the filtering box in the 9311 Macro V1 OD ........................................................................ 10-80
10-34 Front view of the 3 iDACS ac breakers with a yellow rocker situated in the ac distribution module
....................................................................................................................................................................... 10-8810-88
10-88
....................................................................................................................................................................................................................................
x Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
List of figures
PRELIMINARY
....................................................................................................................................................................................................................................
10-35 Location of the iDACS ac breaker in the 9311 Macro V1 OD ............................................................ 10-90
10-41 Front view of the 3 rectifiers ac breakers with a blue rocker situated in the ac distribution module
................................................................................................................................................................... 10-10110-101
10-101
10-42 Location of the rectifier ac breaker in the 9311 Macro V1 OD ........................................................ 10-102
10-47 Front view of the MCA module in the 9311 Macro V1 OD ............................................................... 10-114
10-52 Location of the PCM protection module into the 9311 Macro V1 OD .......................................... 10-122
10-56 Front view of the Interconnection module in the 9311 Macro V1 OD ........................................... 10-134
10-57 Location of the Interconnection module in the 9311 Macro V1 OD ............................................... 10-135
PRELIMINARY
10-60 DC Box connections, with the d4U Node B and the left bulkhead ................................................. 10-143
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary xi
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY List of figures
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
xii Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
About this document
About this document
Purpose
The purpose of this document is to describe the preventive and corrective maintenance
procedures applicable to the Alcatel-Lucent 9311 Macro V1 Node B Outdoor cabinet,
with d4U Node B in the digital shelf. Its short name is 9311 Macro V1 OD with d4U.
The 9311 Macro V1 OD with d4U has the following characteristics:
• A 9926 d4U module in the digital shelf, whose main functions are: network interface,
call and signal processing. The d4U can include up to 2 eCCM-U and up to 6
eCEM-U or up to 6 xCEM-U or a compatible mix between eCEM-U/xCEM-U,
• The RF block which contains the front-end RF modules (1 to 6 TRDUs or 1 to 6
RRHs (external)),
• Power system (AC distribution, filtering, rectifiers),
• Cooling system (iDACS),
• Internal alarms,
• The standard network interface of the 9311 Macro OD1 is a maximum of 8 PCM
E1/T1 (E1 PCM120 Ohms/ 75 Ohms, T1 PCM 100 Ohms).
The standard network interface can be an IP Iub and Hybrid Iub (supported by the
eCCM-U into the d4U).
The following units are optional:
• RETA
• External Alarms
• PCM Protection
• TMA
• DC back-up (internal only)
• Material in User Space.
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary xiii
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY About this document
....................................................................................................................................................................................................................................
Reason for reissue
The reissue history for issue 1.03 is shown in the following table:
Location Change
Roadmap chapter removed (AR 1-4535173)
The reissue history for issue 1.02 is shown in the following table.New features are
highlighted.
Intended audience
The audience for this document is Operations and Maintenance personnel.
Supported systems
This document is release independent, and applies to all Alcatel-Lucent W-CDMA system
releases.
Safety information
For your safety, this document contains safety statements. Safety statements are given at
points where risks of damage to personnel, equipment, and operation may exist. Failure to
follow the directions in a safety statement may result in serious consequences.
....................................................................................................................................................................................................................................
xiv Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
About this document
PRELIMINARY
....................................................................................................................................................................................................................................
Prerequisites
It is recommended that readers become familiar with the following document:
Alcatel-Lucent 9311 Macro V1 Node B Outdoor with 9926 d4U - Technical Description,
3MN-00475-0005-DEZZA.
Conventions used
Vocabulary conventions
For a list of the terms used in this document, see Alcatel-Lucent W-CDMA System -
Terminology, 9YZ-04088-0002-TQZZA.
Some terms are used specifically or generically.
Typographical conventions
The following typographical conventions are used in this document:
Appearance Description
graphical user interface text Text that is displayed in a graphical user interface or
in a hardware label
bold text Emphasized information
Document reference, reference number Related document that is referenced in the document.
Related information
For information on subjects related to the content of this document, refer to the
documents listed in the following table:
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary xv
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY About this document
....................................................................................................................................................................................................................................
Document support
For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
PRELIMINARY
....................................................................................................................................................................................................................................
xvi Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
About this document
PRELIMINARY
....................................................................................................................................................................................................................................
Technical support
For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.
How to order
To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)
How to comment
To comment on this document, go to the Online Comment Form (http://infodoc.alcatel-
lucent.com/comments/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com).
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary xvii
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY About this document
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
xviii Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
1 UTRAN introduction
1
Overview
Purpose
This chapter describes the Universal Mobile Telecommunications System (UMTS)
Terrestrial Radio Access Network (UTRAN).
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 1-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY UTRAN introduction UTRAN introduction
....................................................................................................................................................................................................................................
UTRAN introduction
UTRAN components
The UTRAN is composed of at least one Radio Network Subsystem (RNS). An RNS
covers a certain geographical area. It is equivalent to the GSM BSS. Each RNS is
composed of one Radio Network Controller (RNC) and one or more Node Bs. RNSs are
interconnected through the Iur interface of each RNC to form a network.
Alcatel-Lucent UTRAN
The Alcatel-Lucent UTRAN is based on the following components:
• RNC
• Node B
• WMS for the OAM part
RNC
The Alcatel-Lucent RNC is 3GPP-compliant. It is based on the Multiservice Switch
platform.
RNC interfaces
The RNC provides the following interfaces:
• Iub towards a Node B
• Iu towards the Core Network
• Iur towards another RNC
• Iupc towards a Standalone A-GPS SMLC (SAS)
Node B
The Alcatel-Lucent Node Bs are 3GPP-compliant. The Alcatel-Lucent Node B portfolio
PRELIMINARY
includes:
• Conventional unitary base stations
• Digital base stations
• Radio base stations
....................................................................................................................................................................................................................................
1-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
UTRAN introduction UTRAN introduction
PRELIMINARY
....................................................................................................................................................................................................................................
• Radio heads
• Base station routers
Node B interfaces
The Node B provides the following interfaces:
• Iub towards an RNC
• Uu towards a UE
• Interface B towards WMS
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 1-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY UTRAN introduction UTRAN introduction
....................................................................................................................................................................................................................................
WMS
PRELIMINARY
....................................................................................................................................................................................................................................
1-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
UTRAN introduction UTRAN introduction
PRELIMINARY
....................................................................................................................................................................................................................................
It plays an important role in providing the foundation of a complete end-to-end
management solution for UMTS networks. The WMS manages the entire UMTS
network, which is divided into:
• The UTRAN
• The Core Network (circuit-switched and packet-switched traffics).
The Access Network OAM manages the UTRAN part of the network.
NSP
The Network Services Platform (NSP) is a graphical user interface to the Access Network
providing a common platform for navigation and control. The NSP interfaces with the
NEs through a Common Object Request Broker Architecture (CORBA). This
vendor-independent architecture links computer applications across different networks.
This network configuration requires 9926 d4U Node B or d2U NodeB equipped with GE
MDA and full IP backhaul. Besides, only Alcatel-Lucent base stations are supported in
the daisy chain.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 1-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY UTRAN introduction UTRAN introduction
....................................................................................................................................................................................................................................
In this configuration, the both NodeBs are managed by the same OMC and RNC.
....................................................................................................................................................................................................................................
1-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
UTRAN introduction UTRAN introduction
PRELIMINARY
....................................................................................................................................................................................................................................
Figure 1-4 NodeB dropping 2G BTS
In this configuration, the 2G BTS has to be configured with ABIS interface over
IP/Ethernet.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 1-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY UTRAN introduction UTRAN introduction
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
1-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
2 Safety statements
2
Overview
Purpose
This chapter provides information on the structure of safety statements which may arise
in the course of your work.
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 2-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Safety statements Structure of safety statements
....................................................................................................................................................................................................................................
General structure
Safety statements include the following structural elements:
B C D
CAUTION
MP L E
Lifting hazard E F
SA
Lifting this equipment by yourself can result in injury
due to the size and weight of the equipment.
G
Always use three people or a lifting device to transport
and position this equipment. [ABC123]
H
Item Structure element Purpose
1 Safety alert symbol Indicates the potential for personal injury
(optional)
2 Safety symbol Indicates hazard type (optional)
3 Signal word Indicates the severity of the hazard
4 Hazard type Describes the source of the risk of damage or
injury
5 Safety message Consequences if protective measures fail
6 Avoidance message Protective measures to take to avoid the hazard
7 Identifier The reference ID of the safety statement
(optional)
PRELIMINARY
....................................................................................................................................................................................................................................
2-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Safety statements Structure of safety statements
PRELIMINARY
....................................................................................................................................................................................................................................
Signal words
The signal words identify the hazard severity levels as follows:
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 2-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Safety statements Structure of safety statements
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
2-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
3 3reventive maintenance
P
activity
Overview
Purpose
This chapter describes the preventive maintenance activity applicable to the 9311 Macro
V1 OD cabinet.
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 3-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance activity Preventive maintenance activity
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
3-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Preventive maintenance activity Preventive maintenance activity
PRELIMINARY
....................................................................................................................................................................................................................................
WARNING
Personal injury hazard
The personnel working on the cabinet must be authorized to work according to the
applicable safety standards
NOTICE
Equipment damage hazard
For outdoor equipment, make sure that there is no water trapped on the top of the door
gasket prior to opening doors. If water is present, wipe or sponge off water to avoid water
from entering the equipment.
NOTICE
Equipment damage hazard
Missing panels, covers or blank slot filler modules may lead to incorrect cooling and loss
of EMI integrity. Ensure all covers, panels and filler modules are fitted correctly
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 3-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance activity Preventive maintenance activity
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.
....................................................................................................................................................................................................................................
3-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
4 4 orrective maintenance
C
activity
Overview
Purpose
This chapter describes the corrective maintenance activity applicable to the 9311 Macro
V1 OD cabinet.
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 4-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance activity Corrective maintenance activity
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance activity Corrective maintenance activity
PRELIMINARY
....................................................................................................................................................................................................................................
1AB194670018
Single-Mode (SM) Dual fiber
SFP to radio device:
301030433
1AB187280065
Multi-Mode (MM) SFP to
radio device:
300976297
1AB187280063
Single-Mode (SM) SFP on GE Loss of capacity or service
MDA: interruption on the Iub interface
3HE00028CA (RoHS 6/6) up
to 10Km
3HE00867CA (RoHS 6/6) up
to 40Km
3HE00029CA (RoHS 6/6) up
to 80Km
Multi-Mode (MM) SFP on GE
MDA: 3HE00027CA (RoHS
6/6)
“Replacing the fan rack 3JR37517AE Service interruption
module” (p. 10-24)
“Replacing the pre-cabled 3JR08221AA Service interruption
rack” (p. 10-31)
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 4-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance activity Corrective maintenance activity
....................................................................................................................................................................................................................................
Replacing the power system equipment
....................................................................................................................................................................................................................................
4-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance activity Corrective maintenance activity
PRELIMINARY
....................................................................................................................................................................................................................................
Replacing optional equipment
9311 Macro V1 OD
cable cover”
(p. 10-137)
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 4-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance activity Corrective maintenance activity
....................................................................................................................................................................................................................................
Intervention restrictions
There may be a lapse of time between the identification of the alarm at the Access OAM
Graphic User Interface (GUI) and the time you arrive at the site.
You must be synchronized with the access network controller or system administrator (by
telephone) before an on-site intervention, in the following cases:
• Isolating procedures
• Completion of an on-site intervention
• Return to service procedure
The personnel working on the cabinet must be authorized to work according to security
standards.
....................................................................................................................................................................................................................................
4-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance activity Corrective maintenance activity
PRELIMINARY
....................................................................................................................................................................................................................................
Equipment safety instructions
This solution normally operates when the external temperature is between – 40 °C and
+ 50 °C.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 4-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance activity Corrective maintenance activity
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
4-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
5 5 acro V1 Node B Outdoor
M
with 9926 d4U:
Introduction
Overview
Purpose
This chapter gives an overview of the 9311 Macro V1 OD, configured with a 9926 d4U
Node B in the digital shelf.
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 5-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Macro V1 Node B Outdoor with 9926 d4U: Introduction 9311 Macro V1 OD introduction
....................................................................................................................................................................................................................................
The 9311 Macro V1 OD with d4U can operate only in the 2100 MHz bandwidth with its
internal modules. Other frequencies, i.e. 900 MHz or 850 MHz, can be supported using
remote radio modules (Remote Radio Heads, or RRH)
The following figure shows an outside view of the 9311 Macro V1 OD.
....................................................................................................................................................................................................................................
5-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Macro V1 Node B Outdoor with 9926 d4U: Introduction 9311 Macro V1 OD introduction
PRELIMINARY
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 5-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Macro V1 Node B Outdoor with 9926 d4U: Introduction 9311 Macro V1 OD introduction
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
5-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
6 6311 Macro V1 OD
9
hardware presentation
Overview
Purpose
This chapter describes the hardware presentation of the Macro V1 Node B Outdoor with
9926 d4U.
Contents
Hardware presentation for 9311 Macro V1 OD with d4U digital shelf 6-2
configuration
d4U Node B in a Dual Node B Configuration 6-4
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 6-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD hardware presentation Hardware presentation for 9311 Macro V1 OD with d4U
digital shelf configuration
....................................................................................................................................................................................................................................
• one user rack 3 HU wide, of which one HU is used for the RETA system CCU
• one AC filtering box
The bulkhead allows cable connection and lightning protection.
....................................................................................................................................................................................................................................
6-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD hardware presentation Hardware presentation for 9311 Macro V1 OD with d4U
PRELIMINARY
digital shelf configuration
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 6-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration
PRELIMINARY
....................................................................................................................................................................................................................................
In the dual Node B configuration, an inter-CCM interface allows the two eCCM-U
controllers to communicate across the backplane and check the configuration information
consistency.
Supported Configurations
When the d4U is used in a Dual Node B (2 controller) set-up, the following hardware
configurations are possible:
• eCCMu with GE MDA is supported in Physical slot 5 and 4 for dual controller (Split
Mode).
Note: eCCMu supports up to a maximum of 6 modems in a single controller
configuration.
• xCCMu is not supported in a dual Node B configuration.
Note: xCCMu is supported in a single controller Node B configuration.
• eCCM in Phy slot 5 can support upto 6 CEMs ( 1,2,3,6,7,8).
• eCCM in Phy slot 4 can support upto 3 CEMs ( 1,2,3).
• xCEM and eCEM are supported.
• Hybrid/NativeIP Backhaul is supported. (In a Dual Node B configuration, both Node
Bs need not be using same backhaul )
• Ethernet Backplane (Ethernet-Ethernet), ATM Backplane (ATM-ATM) is supported.
Pre-requisites
The pre-requisites are as follows:
• Single controller in p-slot 5 (CCMA) can support up to a maximum of 6 modems
• In this set up, BTS_Mode is Single Technology
Upgrade procedure
Step Action Observation
1 Upgrade the software controller to
DualNodeB supported load and
Reboot.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 6-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration
....................................................................................................................................................................................................................................
Downgrade procedure from DualNode B supported load to DualNode B unsupported load in d4Uv3
to Single Technology
Pre-requisites
The pre-requisites are as follows:
• Two Controllers with DualNode B can support up to a maximum of 6 modems.
• In this set up, the BTS_Mode is Dual_Node B.
Downgrade procedure
Step Action Observation
1 Plug out the CCM-B..
2 Use the daisy chain configuration for
the alarm cable.
3 Connect eAM to FanTray-2.
4 Connect SiteLAN to CCM-A.
5 Connect to CCM-A TIL, and modify
BTS_Mode from DualNodeB to Single
Technology.
6 Downgrade the controller and reboot.
PRELIMINARY
....................................................................................................................................................................................................................................
6-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration
PRELIMINARY
....................................................................................................................................................................................................................................
Migration from Single Technology configuration to BTS mode, with DualNodeB supported load
Pre-requisites
The prerequisites are as follows:
• Single controller in p-slot 5 (CCMA) can support up to a maximum of 6 modems
• The alarm cable is daisy chained
• Cabinet and external alarm kit is connected to Fan Tray 2
• SiteLAN connected to CCMA
• In both the fantrays, BTS_Mode is Single Technology
Migration procedure
Step Action Observation
1 Connect to TIL and update the
BTS_Mode to DualNodeB, NeID and
modem slot array in FanTray-1.
2 Plug out the controller.
3 Remove daisy chaining of the alarm
cable between fan tray.
4 Move cabinet and external alarm kit
from fan tray 2 to fan tray 1.
5 Connect SiteLAN to CCMA.
6 Insert second controller in CCMB with
Dual NodeB supported load.
7 Connect the alarm cable between
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 6-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration
....................................................................................................................................................................................................................................
Migration procedure
8 Connect to TIL of CCMB and update
BTS_Mode to DualNodeB, NeID and
modem slot array in FanTray-2 and
reboot.
9 Insert CCMA back. Now both the controllers are in
DualNodeB configuration.
Upgrade procedure from Single Technology configuration with DualNodeB unsupported load to
DualNodeB with DualNodeB supported load
Pre-requisites
The prerequisites are as follows:
• Single controller with DualNodeB unsupported load in p-slot 5 (CCMA) can support up to a
maximum of 6 modems
• The alarm cable is daisy chained
• Cabinet and external alarm kit is connected to Fan Tray 2
• Before the upgrade procedure, BTS_Mode is Single Technology
PRELIMINARY
....................................................................................................................................................................................................................................
6-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration
PRELIMINARY
....................................................................................................................................................................................................................................
Upgrade procedure
Step Action Observation
1 Upgrade the software controller to
DualNode B supported load and
reboot.
2 Connect to TIL of CCM_A and update
BTS_Mode to DualNodeB, NeID and
modem slot array in FanTray-1.
3 Plug out the controller.
4 Remove daisy chaining of the alarm
cable between fan trays.
5 Move cabinet and external alarm kit
from fan tray 2 to fan tray 1.
6 Insert the second controller in CCMB
with DualNodeB unsupported load.
7 Connect the alarm cable between
CCMB and fantray-2.
8 Upgrade to DualNode B supported
load and reboot.
9 Connect to TIL of CCMB and update
BTS_Mode to DualNodeB, NeID and
modem slot array in FanTray-2 and
reboot.
10 Insert CCMA back. Now both the controllers are in
DualNodeB configuration.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 6-9
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Two controllers with conflicting modem allocation in ModemSlotArray
Note: This is a configuration error scenario and might lead to Bus Conflict on the
backplane.
In such case, where both the controllers are in conflict with modem allocation in
ModemSlotArray, the controllers do the following:
• Both controllers raise an alarm Inconsistent Partner Board Configurationto OMCB
• Both controllers disconnect HSSL/GigE/1-wire connections to the problematic
inconsistent modem slot
NE ID received from IML does not match with NE ID read from I&C
When the controller detects that the NE ID received from IML does not match with the
NE ID read from I&C, it raises alarmInconsistent Partner NodeB Name.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 6-11
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
6-12 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
7 Checking the door alarm
7
Overview
Purpose
This part describes how to check the door alarm.
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 7-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Checking the door alarm Checking the door alarm
....................................................................................................................................................................................................................................
Intervention time
Two minutes
Tools required
None
Important! This procedure requires to be in contact with the OMC administrator.
Important! For outdoor models, do not forget to ask the site manager for the Node B
key.
Procedure
...................................................................................................................................................................................................
1 Contact the OMC administrator to check that the door alarm is OFF.
...................................................................................................................................................................................................
3 An alarm must be observed at the OMC. Request confirmation from the OMC
administrator.
...................................................................................................................................................................................................
5 Check with the OMC administrator that the door alarm is OFF.
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY
....................................................................................................................................................................................................................................
7-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
8 8311 Macro V1 OD power
9
up and power down
procedures
Overview
Purpose
This chapter describes how to power up and power down the 9311 Macro V1 OD
cabinets, when configured with a 9926 d4U in the digital shelf.
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 8-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U
....................................................................................................................................................................................................................................
Tools required
• Key to open the door
• Lamp
• Multimeter
• Phillips screwdrivers
• Tie rap pliers
Initial Checks
The aim of this section is to check that the cabinet(s) (9311 Macro V1 OD and battery
cabinet if employed) is (are) properly set up and ready to be powered up.
The initial checks are the following:
1. Visually check that:
• The 9311 Macro V1 OD is correctly secured.
•
The battery cabinet (if employed) is correctly secured.
•
The 9311 Macro V1 OD and battery cabinet does not exhibit any sign of physical
damage.
Note: If physical damage is observed, notify the supervisor immediately.
• The circuit breaker(s) of the customer AC box (9311 Macro V1 OD and battery
cabinet if that exists) is (are) properly labeled and OFF.
2. Open the doors of the cabinet and look at the internal batteries and check if:
• The date mm/yy has not expired within a six month time frame.
Note: If the six month period after the deadline has elapsed, the batteries must be
returned to a warehouse for complete recharging.
• Each battery is properly connected, check the cables, straps, terminal blocks.
3.
On the 9311 Macro V1 OD, check that the following components are switched OFF:
• All breakers of the AC Main.
PRELIMINARY
PRELIMINARY
....................................................................................................................................................................................................................................
- CB05 Rectifiers 5-6-7
- CB06 DACS Blower
- CB07 AC outlet differential breaker
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 8-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U
....................................................................................................................................................................................................................................
Figure 8-2 DC Breaker Panel used with the d4U Node B configuration
....................................................................................................................................................................................................................................
8-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U
PRELIMINARY
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
1 At the customer AC box, switch ON the circuit breaker of the 9311 Macro V1 OD
cabinet.
...................................................................................................................................................................................................
2 Open the AC cover by removing the screws that secure the plate.
...................................................................................................................................................................................................
Net- Termi- 1 2 3 4 5 6
work nal
type block
position
Single Measure L1 N GND N
Phase between
L1 and N
Split Measure L1 L2 GND N
Phase between
L1 and
L2 and
between
L2 and N
Triphase Measure L1 L2 GND
120/208 between
L1 and
L2, and
between
L2 and N
Triphase Measure L1 L2 L3 N GND
230/400 between
each
Phase
and
Neutral:
PRELIMINARY
L1 and
N, L2
and N,
L3 and N
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 8-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
4 Put the cover of the AC box back in place and secure it.
...................................................................................................................................................................................................
6 Listen to the fans starting up and check that the eight LEDs of the iDACS are lit up green.
...................................................................................................................................................................................................
Check that the green "ON" LED lit on each rectifiers shortly after.
...................................................................................................................................................................................................
8 Once each rectifier have been switched ON, check that the green "ON" LED lit on the
SPCM.
...................................................................................................................................................................................................
9 Switch ON the battery breaker located on the DC distribution in case a back-up battery is
PRELIMINARY
employed (internal).
....................................................................................................................................................................................................................................
8-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U
PRELIMINARY
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
10 Switch ON the User circuit breaker located on the DC distribution (see figure above).
...................................................................................................................................................................................................
11 Measure the voltage on the user port PWR by using a multimeter in V DC mode. Check
that the value is within the specified range.
...................................................................................................................................................................................................
...................................................................................................................................................................................................
13 Switch ON the DACS and the RF circuit breakers located on the DC distribution.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 8-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
15 On the DC Breaker Panel, power up the Breaker 25A Fan Rack Lower and the Breaker
40A RRH, if used.
Figure 8-5 DC Breaker Panel used with the d4U Node B configuration
PRELIMINARY
....................................................................................................................................................................................................................................
8-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U
PRELIMINARY
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
16 Switch ON the circuit breaker of the digital shelf located on the DC distribution.
...................................................................................................................................................................................................
17 Switch ON the power switches for the upper and lower fan racks on the d4U Node B.
The 9311 Macro V1 OD is now powered ON.
...................................................................................................................................................................................................
18 Check that the 9311 Macro V1 OD is in an operational state after its BISTs by checking
the LEDs status.
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 8-9
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD power up and power down procedures Powering down a 9311 Macro V1 OD with d4U
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
8-10 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
9 9reventive maintenance
P
procedures
Overview
Purpose
This chapter describes the preventive maintenance procedures of the Macro V1 Node B
Outdoor with 9926 d4U.
The preventive maintenance is used periodically for the items of equipment which do not
directly trigger any alarm at the WMS.
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 9-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance procedures Inspecting the Connectors
....................................................................................................................................................................................................................................
Intervention time
One hour
Tools required
• Flat screwdrivers
• 7/16 torque wrench
DANGER
Environment and personnel protection
Caution presence of voltage.
CAUTION
Tightening torques
The 7/16 tightening torque must be 25 N.m (24 N.m to 27 N.m).
PRELIMINARY
....................................................................................................................................................................................................................................
9-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Preventive maintenance procedures Inspecting the Connectors
PRELIMINARY
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
2 Check for corrosion or oxidation around connectors, nicks and abraded sheaths.
Note: This may be more prevalent in high heat and high humidity environments.
...................................................................................................................................................................................................
• One Manufacturing connector from the MCA module and tighten it with screwdriver.
• One I/C1 connector from the MCA module and tighten it with screwdriver.
• One I/C2 connector from the MCA module and tighten it with screwdriver.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 9-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance procedures Inspecting the Connectors
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
4 Inspect one CEATS connector from the SPCM and tighten it with screwdriver on the DC
power system shelf.
...................................................................................................................................................................................................
6 Inspect the RF antenna connectors from the TRDU TX/RX and bulkhead, if used:
• The two RF antenna connectors labeled RX and TX/RX and tighten them with the
7/16 torque wrench.
...................................................................................................................................................................................................
8 Inspect the RF connectors from the bulkhead and tighten them with 7/16 torque wrench.
...................................................................................................................................................................................................
9 Replace or repair any damaged cables as necessary. Call the next level of support.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
9-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Preventive maintenance procedures Inspecting the anchor bolts
PRELIMINARY
....................................................................................................................................................................................................................................
Intervention time
20 minutes
Tools required
• Special TORX key inside the Node B
• 19-mm key
• 17-mm wrench
WARNING
Electric-shock hazard
The Node B remains supplied with the mains power supply.
There is a risk of sparks during the test.
Personnel safety rules: the personnel performing this check must wear rubber gloves and
must be isolated from the ground.
Procedure
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 9-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance procedures Inspecting the anchor bolts
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
2 Displacement
The displacement of back and side access panels is necessary to access the anchor bolts.
Unscrew the inviolable screws with the special TORX key and remove the access panels.
...................................................................................................................................................................................................
3 Inspect anchor bolts at the base of the cabinet for tightness and/or damage:
• If anchor bolts are OK, go to step 5.
• If anchor bolts are damaged or not tight, go to next step.
...................................................................................................................................................................................................
...................................................................................................................................................................................................
5 Replacement
Replace the access panels as they were before intervention.
....................................................................................................................................................................................................................................
9-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Preventive maintenance procedures Inspecting the anchor bolts
PRELIMINARY
....................................................................................................................................................................................................................................
Tighten the inviolable screws with the special TORX key.
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 9-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance procedures Inspecting the AC inlet cable gland
....................................................................................................................................................................................................................................
Intervention time
30 minutes
Tools required
Wrench
Procedure
...................................................................................................................................................................................................
2 Inspect the cable gland body nut (inside cabinet) for tightness.
...................................................................................................................................................................................................
4 Check the rubber gasket of the cable gland for damage such as cracking.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
9-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Preventive maintenance procedures Inspecting the EMC door gasket
PRELIMINARY
....................................................................................................................................................................................................................................
Intervention time
15 minutes
Tools required
None
Procedure
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 9-9
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance procedures Inspecting the EMC door gasket
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
9-10 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
10 10
Corrective maintenance
procedures
Overview
Purpose
This chapter contains the replacement procedures applicable to the Macro V1 Node B
Outdoor with 9926 d4U.
Contents
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Overview
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Overview
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Overview
Purpose
This section presents the replacement procedures applicable to 9926 d4U elements in the
digital shelf.
Contents
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CEM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Replacing a CEM
Carry out the following procedure to replace a eCEM-U or xCEM-U.
Intervention time
10 minutes
Tools required
Screwdriver
Extraction tool
....................................................................................................................................................................................................................................
10-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CEM
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Figure 10-2 eCEM-U front panel
NOTICE
ESD hazard
Wear the antistatic bracelet when performing the maintenance procedure described
below.
NOTICE
Service-disruption hazard
This procedure causes a loss of capacity or a loss of service (depending on the number of
CEMs housed in the digital shelf of the 9926 d4U Node B).
NOTICE
Service-disruption hazard
When inserting a new eCEM-U module next to an existing xCEM-U module, this last one
reboots. When the xCEM-U module reboots, the assigned sector or frequency loses its
traffic.
To avoid this traffic loss, the cell or sector associated with the xCEM-U must be locked.
PRELIMINARY
Procedure
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CEM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
• For an eCEM-U:
– First LED (from top) is red.
– Second LED (from top) is OFF.
...................................................................................................................................................................................................
3 Lock the faulty cem object at the WMS by Set Administrative State.
Attention: If there is an xCEM-U module adjacent to the eCEM-U module to install,
lock also the xCEM-U module associated object in the WMS.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................
4 Undo and remove the lower or upper hook (if present and if the defective CEM is in slot 1
or slot 8).
PRELIMINARY
....................................................................................................................................................................................................................................
10-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CEM
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CEM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
6 Using the extraction tool, pull the defective CEM out of the shelf, see Figure 10-3,
“Extracting a CEM” (p. 10-8).
...................................................................................................................................................................................................
8 Insert the new CEM into the digital shelf of the 9926 d4U Node B, in the same slot as the
defective CEM.
...................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CEM
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
11 From the WMS, unlock the cem object previously locked on the Step 3.
Attention: In the case where the eCEM-U module to install is adjacent to an xCEM-U
module, don't forget to also unlock the xCEM-U module associated object in the
WMS.
...................................................................................................................................................................................................
12 Check the state of the LEDs. They should go on, then take the following state:
• On a xCEM-U:
– Red LED is OFF.
– Green LED is ON.
• On an eCEM-U:
– First LED (from top) is OFF.
– Second LED (from top) is green.
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-9
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CCM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Replacing a CCM
Purpose
Carry out the following procedure to replace a eCCM-U or xCCM-U.
Intervention time
20 minutes
Tools required
• A screwdriver
• An extraction tool
....................................................................................................................................................................................................................................
10-10 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CCM
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser radiation can cause
considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the
optical source is switched on. Always observe the laser warning instructions.
NOTICE
ESD hazard
Wear the antistatic bracelet when performing the maintenance procedure described
below.
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.
NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Important! There will be a loss of service on the Remote Radio device(s) and on the
dropped BTS in case of BTS daisy chaining through the NodeB .
Attention: If the replacement operation takes place in the context of the 9926 d4U
Node B upgrade with a CCM-U module from spare or from the factory containing a
UA7.1 software load, it is mandatory to remove all the CEM-U modules before
performing the software upgrade or the new UA08.1 software load will not start
correctly. This document considers only the Node B upgrade with the TIL.
Procedure
...................................................................................................................................................................................................
2 Lock all the objects associated with the Remote Radio devices and the dropped BTS
connected to the faulty CCM at the WMS by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-11
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CCM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Attention: In case of the UA7.1 to UA08.1 software upgrade, don't forget to lock also
all the cem objects as it is mandatory to remove all the CEM-U modules before
performing the software upgrade.
...................................................................................................................................................................................................
4 Loosen the two screws on the front panel of the CCM module to remove.
....................................................................................................................................................................................................................................
10-12 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CCM
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
5 Using the extraction tool, unplug the CCM from its RBP connectors, see Figure 10-6,
“Extracting a CCM” (p. 10-12).
Attention: In case of the UA7.1 to UA08.1 software upgrade, unplug also all the
existing CEM modules, see Figure 10-3, “Extracting a CEM” (p. 10-8).
...................................................................................................................................................................................................
6 Unplug the GPS cable (connector labeled “GPS”) from the CCM front panel if used.
...................................................................................................................................................................................................
7 Unplug the optical fiber(s) and remove the SFP transceiver(s) (connector(s) labeled
“OPTIC”) from the CCM front panel.
Note: The SFP transceiver(s) will be re-plugged in the new xCCM-U-GE or
eCCM-U-GE.
...................................................................................................................................................................................................
8 Unplug the digital cable (connector labeled "ALARM") from the CCM front panel.
...................................................................................................................................................................................................
9 Unplug the TIL cable (labeled “PORT 1”) from the CCM front panel.
...................................................................................................................................................................................................
11 Pull the CCM out of the shelf, see Figure 10-6, “Extracting a CCM” (p. 10-12).
...................................................................................................................................................................................................
12
If the removed CCM is... Then...
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-13
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CCM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Procedure “Configure the new eCCM-U”:
1. Locate the DIP switch on the module as indicated in the
Figure 10-7, “Location of the DIP switch on the eCCM-U”
(p. 10-14).
2. Set the DIP switch on the module to the “UMTS” position
(see Figure 10-8, “DIP switch settings on the eCCM-U”
(p. 10-15)).
Note: If necessary, set the DIP switch to the right position
with help of a screwdriver.
....................................................................................................................................................................................................................................
10-14 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CCM
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Figure 10-8 DIP switch settings on the eCCM-U
...................................................................................................................................................................................................
13 Insert the new CCM module(s) into the slot guides without plugging it on the RBP.
...................................................................................................................................................................................................
14 Reconnect the GPS cable (connector labeled “GPS”) on the CCM front panel if used.
...................................................................................................................................................................................................
15 Reinsert the SFP transceiver(s) (connector(s) labeled “OPTIC”) in the CCM front panel.
...................................................................................................................................................................................................
16 Reconnect the optical fiber(s) (connector(s) labeled “OPTIC”) on the CCM front panel.
Important! In case of an CCM module equipped with Multi-Mode (MM) or
Single-Mode (SM) Dual fiber SFP transceivers, put the LC connectors (L/R) in the
same sense as they were before the intervention when reconnecting the optical fibers
on the CCM front panel,.
...................................................................................................................................................................................................
17 Reconnect the digital cable (connector labeled "ALARM") on the CCM front panel.
...................................................................................................................................................................................................
18 Reconnect the TIL cable (labeled “PORT 1”) on the CCM front panel.
...................................................................................................................................................................................................
• Reconnect the Gigabit Ethernet cable(s) (labeled “MDA”) on the CCM front panel.
• Reconnect the E1/T1 cable if used and / or the PCM connector cover (labeled “PCM
E1/T1”) on the CCM front panel.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-15
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CCM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Important! In case of an CCM module equipped with Multi-Mode (MM) or
Single-Mode (SM) Dual fiber SFP transceivers, put the LC connectors (L/R) in the
same sense as they were before the intervention when reconnecting the optical fibers
on the CCM front panel.
...................................................................................................................................................................................................
20 Insert completely the new CCM module(s) into the 9926 d4U Node B rack by plugging it
into its RBP connectors.
...................................................................................................................................................................................................
22
If the new CCM is... Then...
an xCCM-U Proceed with the Step 23 of this procedure
an eCCM-U Proceed with the Step 1 of the procedure
“Check the eCCM-U LEDs status”
24 Unlock from the WMS the objects previously locked through the Step 3.
PRELIMINARY
Attention: In case of the UA7.1 to UA08.1 software upgrade, do not unlock the cem
objects.
....................................................................................................................................................................................................................................
10-16 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CCM
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
25 In case of a standard CCM module replacement, check the state of the LEDs of the both
CEM and CCM modules.
On the xCEM-U and xCCM-U:
• The xCEM-U LEDs should turn on, then take the following state:
– Red LED: OFF.
– Green LED: ON.
• The xCCM-U LEDs should turn on, then take the following state:
– Red LED: OFF.
– Green LED: ON.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-17
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CCM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
• The eCCM-U SYNC LEDs should have the following state:
– Green, red or amber according to the synchronization source selected by the 9926
d4U Node B.
• The eCCM-U MDA LEDs and PCM LEDS status depends on the Iub interface type
(IP-based or hybrid).
Attention: In case of the UA7.1 to UA08.1 software upgrade, check only the CCM
module state of the LEDs as all the CEM modules are out of the rack while the
software upgrade is not achieved.
...................................................................................................................................................................................................
27 For a UA7.1 to UA08.1 software upgrade with the TIL, proceed according to the
procedure described in the Alcatel-Lucent 9100 and 93xx Node B - UA08.1
Commissioning and Fault Management User Manual: TIL, NN-20500-019.
...................................................................................................................................................................................................
28 Once the software upgrade is achieved, replace the CEM modules in the 9926 d4U Node
B.
...................................................................................................................................................................................................
30 Check the state of the CEM modules LEDs as described in the Step 25.
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY
....................................................................................................................................................................................................................................
10-18 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing an optical transceiver
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Intervention time
5 minutes
Tools required
None
DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser radiation can cause
considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the
optical source is switched on. Always observe the laser warning instructions.
NOTICE
ESD hazard
Wear the antistatic bracelet when performing the maintenance procedure described
below:
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.
NOTICE
Service-disruption hazard
This procedure causes a loss of service.
Important! There will be a loss of service on the Remote Radio device or on the
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-19
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing an optical transceiver
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
2 Locate the faulty SFP transceiver in the labeled “OPTIC” or “MDA” connector: its two
green RX/TX LEDs are OFF.
...................................................................................................................................................................................................
3
If the defective SFP transceiver is ... Then...
connected to a remote radio device (connector Continue on with the Step 4 of this procedure
labeled “OPTIC” on the CCM front panel)
connected to the backhaul or to a dropped BTS Go to the “Backhaul procedure” (p. 10-21)
(connector labeled “MDA” on the CCM front
PRELIMINARY
panel)
....................................................................................................................................................................................................................................
10-20 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing an optical transceiver
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
4 At the WMS, through Set Administrative State, lock the FDDCell object associated with
the remote radio device connected to the optical transceiver being replaced.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................
6 Pull out with care the defective SFP transceiver of the SFP cage.
...................................................................................................................................................................................................
7 Check that the new replacing SFP transceiver has the same type as the SFP transceiver
being replaced. Be sure to replace a Single Mode (SM) SFP transceiver with a SM SFP
transceiver and a MM SFP transceiver with a MM SFP transceiver.
...................................................................................................................................................................................................
8 Put in place the new SFP transceiver and insert it in the CCM.
...................................................................................................................................................................................................
10 Unlock from the WMS the FDDCell object previously locked through Step 4.
...................................................................................................................................................................................................
11 On the CCM, check that the two green RX/TX OPTIC LEDs are ON.
E...................................................................................................................................................................................................
N D O F S T E P S
Backhaul procedure
...................................................................................................................................................................................................
PRELIMINARY
1 Lock at the WMS through the Set Administrative State command all the objects
associated with the dropped BTS .
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-21
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing an optical transceiver
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
4 Pull out with care the defective SFP transceiver of the SFP cage.
...................................................................................................................................................................................................
5 Check that the new replacing SFP transceiver has the same type as the SFP transceiver
being replaced. Be sure to replace a Single Mode (SM) SFP transceiver with a SM SFP
transceiver and a MM SFP transceiver with a MM SFP transceiver.
...................................................................................................................................................................................................
6 Put in place the new SFP transceiver and insert it in the CCM.
...................................................................................................................................................................................................
9 Unlock from the WMS all the objects previously locked through Step 1.
....................................................................................................................................................................................................................................
10-22 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing an optical transceiver
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
10 On the CCM, check that the two green RX/TX MDA LEDs are ON.
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-23
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the fan rack module
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Intervention time
15 minutes
Tools required
M4 nut driver
WARNING
Safety Hazard, Hardware Damage
Replacing a defective fan try with a different model may damage the hardware and could
represent a potential safety hazard.
When replacing the fan tray, it must be replaced with the same model. Eg: A -48V d2Uv5
fan tray must be replaced by the same model, not a d2Uv2 fan tray or +24V fan tray
PRELIMINARY
model.
....................................................................................................................................................................................................................................
10-24 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the fan rack module
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Wear the antistatic bracelet when performing the maintenance procedure described
below.
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.
NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Procedure
...................................................................................................................................................................................................
2 Lock the cem object as well as all the objects associated with the Remote Radio devices
connected to the CCM at the WMS, by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................
4 Unplug the – 48 V power cable from the RUC front panel with the M4 nut driver.
PRELIMINARY
...................................................................................................................................................................................................
5 Unplug the two Dallas one-wire cables from the connectors labeled "ALARM/INT" on
the RUC front panel.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-25
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the fan rack module
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
6 Using the top handle of the RUC front panel in failure, pull the defective fan rack module
out of the shelf.
....................................................................................................................................................................................................................................
10-26 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the fan rack module
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Figure 10-12 RUC and fan rack module
Back
RUC
Front
RUC
Fans Lock
...................................................................................................................................................................................................
7 Put the new fan rack module in place and insert it completely into the 9926 d4U Node B.
...................................................................................................................................................................................................
8 Reconnect the two Dallas one-wire cables to the connectors labeled "ALARM/INT" on
the RUC front panel.
...................................................................................................................................................................................................
9 Reconnect the – 48 V power cable on the RUC front panel with the M4 nut driver.
PRELIMINARY
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-27
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the fan rack module
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
To do this, follow the procedure “Powering up a 9926 d4U Node B” (p. A-2), according
to the hardware configuration of the 9926 d4U Node B:
• In mono-controller configuration, switch on the power supply of the both RUCs.
• In dual controller configuration, switch on the RUC power supply of the replaced fan
rack module.
...................................................................................................................................................................................................
11 Unlock from the WMS the objects previously locked through step 1.
...................................................................................................................................................................................................
12 Reprogram the I & C : After replacing the fan tray, the I&C must be re-programed to
match the older one.
Refer to the corresponding procedure in the chapter on Replacing the Pre-cabled Rack,
from , beginning with the step “Connect the TIL” through step “Disconnect the TIL.”
...................................................................................................................................................................................................
13 Check the state of the CCM and CEM LEDs and display.
On the xCCM-U and xCEM-U, the LEDs should take the following states:
• The xCCM-U LEDs should turn on, then take the following state:
– Red LED: OFF.
– Green LED: ON.
....................................................................................................................................................................................................................................
10-28 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the fan rack module
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-29
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the fan rack module
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY
....................................................................................................................................................................................................................................
10-30 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Intervention time
40 minutes
Tools required
• A screwdriver
• An extraction tool
• A M4 nut driver
• A wrench for hexagonal head (M5 nut)
DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser radiation can cause
considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the
optical source is switched on. Always observe the laser warning instructions.
NOTICE
ESD hazard
Wear the antistatic bracelet when performing the maintenance procedure described
below:
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions. PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-31
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the pre-cabled rack
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Procedure
...................................................................................................................................................................................................
2 Lock the CEM object as well as all the objects associated with the radio device(s)
connected to the CCM at the WMS, by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................
4 Unplug the – 48 VDC power cable from each RUC front panel with the M4 nut driver.
...................................................................................................................................................................................................
5 Unplug the ground cable from the ground stud of the rack with the wrench for hexagonal
head (M5 nut).
PRELIMINARY
....................................................................................................................................................................................................................................
10-32 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
6 Remove the management sticker located on the lug, on the right hand side of the 9926
d4U Node B rack.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-33
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the pre-cabled rack
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
This removable sticker contains a 6-digit Network IDentifier (NeID) that is used at 9926
d4U Node B connection to the WMS. This sticker must be stored in a safe location since
it will be reused on the new 9926 d4U Node B rack.
....................................................................................................................................................................................................................................
10-34 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
7 Undo and remove the upper and lower hooks (if present).
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-35
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the pre-cabled rack
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
9 Using the extraction tool, pull the CEM out of the shelf, see Figure 10-14, “Extracting the
CEM and CCM” (p. 10-36).
...................................................................................................................................................................................................
10 Loosen the two screws on each CCM front panel and pull out a little bit the module.
...................................................................................................................................................................................................
• Unplug the optical fiber(s) from the CCM module(s) front panel.
• Unplug the alarm cable (connector labeled "ALARM") from the CCM front panel.
• Unplug the two input/output synchronization cables (connectors labeled "IN" and
"REF OUT") from the CCM front panel if used.
....................................................................................................................................................................................................................................
10-36 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
• Unplug the TIL connection cable (connector labeled "PORT 1") from the CCM front
panel.
• Unplug the Ethernet connection cable (connector labeled "PORT 2") from the CCM
front panel if used.
• Unplug the PCM E1/T1 cable (connector labeled "PCM E1/T1") and the MDA cable
(connector labeled "MDA") from the CCM front panel if used.
...................................................................................................................................................................................................
12 Loosen completely the two screws on the CCM front panel, see Figure 10-14, “Extracting
the CEM and CCM” (p. 10-36).
...................................................................................................................................................................................................
13 Using the extraction tool, pull the CCM module(s) out of the shelf, see Figure 10-14,
“Extracting the CEM and CCM” (p. 10-36).
...................................................................................................................................................................................................
14 Remove the defective 9926 d4U Node B rack by unscrewing its eight screws (four screws
on each side).
...................................................................................................................................................................................................
15 Put the new 9926 d4U Node B rack in place and fix the rack with its eight screws.
...................................................................................................................................................................................................
16 Fix the NeID sticker on the right hand side of the RUC, on the lug of the new 9926 d4U
Node B rack.
...................................................................................................................................................................................................
18 Reinsert the CCM module(s) in the new digital shelf without plugging it on the RBP
d4Uv3.
...................................................................................................................................................................................................
19 Reconnect the – 48 VDC power cable to the RUC front panel with the M4 nut driver.
...................................................................................................................................................................................................
20 Reconnect the ground cable to the ground stud of the rack with the wrench for hexagonal
head (M5 nut).
PRELIMINARY
...................................................................................................................................................................................................
22 Insert completely the CCM module(s) into the digital shelf by plugging it into its RBP
connectors.
...................................................................................................................................................................................................
23 Tighten the two screws on the CCM, CEM and RUC front panel.
...................................................................................................................................................................................................
24 Put the two hooks in place and secure them, see “Procedure” (p. 10-35).
...................................................................................................................................................................................................
26 Unlock from the WMS the objects previously locked through Step 2.
...................................................................................................................................................................................................
27 Connect the TIL on the 9926 d4U Node B on "PORT1" of the CCM to modify the
pre-cabled rack inventory parameters.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-38 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-39
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the pre-cabled rack
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-40 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
33 Using the information printed on the pre-cabled rack labels present on the left hand side
of the 9926 d4U Node B spare, fill out the following fields:
• Serial Number
• Manufacturing Date
PRELIMINARY
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-41
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the pre-cabled rack
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
...................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-42 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
other RUC should have the NEID with “000000” as a spare. It is possible to manage
only one NEID per DBS 4U.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-43
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the pre-cabled rack
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
46 Check the state of the CCM and CEM LEDs and display.
On the xCEM-U and xCCM-U:
• The xCEM-U LEDs should turn on, then take the following state:
– Red LED: OFF.
– Green LED: ON.
• The xCCM-U LEDs should turn on, then take the following state:
– Red LED: OFF.
– Green LED: ON.
....................................................................................................................................................................................................................................
10-44 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack
PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
• The eCCM-U SYNC LEDs should have the following state:
– Green, red or amber according to the synchronization source selected by the 9926
d4U Node B.
• The eCCM-U MDA LEDs and PCM LEDS status depends on the Iub interface type
(IP-based or hybrid).
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-45
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Overview
Replacing the RF block equipment
....................................................................................................................................................................................................................................
Overview
Purpose
This section presents the replacement procedures applicable to the RF block of a 9311
Macro V1 OD with d4U.
Contents
....................................................................................................................................................................................................................................
10-46 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing a TRDU
PRELIMINARY
Replacing the RF block equipment
....................................................................................................................................................................................................................................
Intervention time
15 minutes
Tools required
• 7/16 torque wrench
• Phillips screwdriver
• Extraction tool (3JR08430AA)
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-47
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing a TRDU
Replacing the RF block equipment
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-48 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing a TRDU
PRELIMINARY
Replacing the RF block equipment
....................................................................................................................................................................................................................................
Figure 10-16 TRDU60-21B front panel
CAUTION
Burn hazard
Module becomes very hot during operation.
Wear gloves when removing the module.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-49
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing a TRDU
Replacing the RF block equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.
NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Important! Service is lost on the radio links associated with the TRDU being
replaced.
Important! The 7/16 tightening torque must be 25 N.m (24 N.m to 27 N.m).
Important! Respect bend radius of cables while tightening connectors.
Pay attention to cable torsion and bend radius during maintenance operations.
Procedure
...................................................................................................................................................................................................
1 Locate the faulty TRDU in the TRDU shelf: its red LED is on.
...................................................................................................................................................................................................
2 At the OMC, lock the faulty TRDU by Set Administrative State. For more information,
refer to Alcatel-Lucent 9353 Wireless Management System - User Guide,
9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................
3 Switch off the faulty TRDU (on the TRDU front panel, put the power switch in the "O"
position).
PRELIMINARY
....................................................................................................................................................................................................................................
10-50 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing a TRDU
PRELIMINARY
Replacing the RF block equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
4 On the front panel of the faulty TRDU, disconnect the following cables:
• The two RF antenna cables (connectors labeled "RX" and "TX/RX"), using the 7/16
wrench
• The CPRI cable (connector labeled "DATA I/O SLAVE")
• The AISG input digital cable (9-pin D-SUB connector labeled "AISG IN"), if CCU
for RETA is used
...................................................................................................................................................................................................
5 Important! Beware that if you do not disconnect the power cable at the
interconnection module, there is a risk of destroying the equipment, because of a
PRELIMINARY
6 Untighten the four TRDU front panel screws using the Phillips screwdriver.
...................................................................................................................................................................................................
8 Remove the depth adaptor from the defective TRDU, and mount onto the new TRDU.
...................................................................................................................................................................................................
10 Tighten the four screws on the new TRDU front panel using the Phillips screwdriver.
...................................................................................................................................................................................................
11 Check that the power switch on the new TRDU is in the "O" position.
...................................................................................................................................................................................................
12 On the new TRDU front panel, connect the power cable to the "POWER IN" connector.
...................................................................................................................................................................................................
13 DANGER
Personnel protection
When connecting the power cable to the interconnection module, be careful not to touch
the interconnection module.
Connect the power cable to the interconnection module.
...................................................................................................................................................................................................
15 Switch on the new TRDU (on the TRDU front panel, put the power switch in the "I"
position).
PRELIMINARY
....................................................................................................................................................................................................................................
10-52 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing a TRDU
PRELIMINARY
Replacing the RF block equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
16 If the TRDU is not automatically unlocked, unlock the TRDU at the OMC by Set
Administrative State. For more information, refer to Alcatel-Lucent 9353 Wireless
Management System - User Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................
17 On the CCM-U front panel, for the CPRI port concerned, check that the Tx and Rx LEDs
are green (the communication is established between the 9311 Macro V1 OD and the new
TRDU).
...................................................................................................................................................................................................
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-53
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Overview
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
Overview
Purpose
This section presents the replacement procedures applicable to the cooling systems of the
9311 Macro V1 OD.
Contents
Replacing the Direct Ambient Cooling System (DACS) of the 9311 Macro V1 10-55
OD
Replacing the iDACS blowers of the 9311 Macro V1 OD 10-59
Replacing the iDACS control board of the 9311 Macro V1 OD 10-61
Replacing the iDACS heaters of the 9311 Macro V1 OD 10-66
Replacing the iDACS air filter of the 9311 Macro V1 OD 10-68
PRELIMINARY
....................................................................................................................................................................................................................................
10-54 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Direct Ambient Cooling System (DACS) of the
PRELIMINARY
Replacing the cooling system equipment 9311 Macro V1 OD
....................................................................................................................................................................................................................................
Intervention time
Ten minutes
Tools required
Screwdriver
CAUTION
Service interruption
This procedure requires a service interruption of the 9311 Macro V1 OD estimated at ten
minutes.
Procedure
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-55
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Direct Ambient Cooling System (DACS) of the
Replacing the cooling system equipment 9311 Macro V1 OD
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
2 Switch off the iDACS circuit breaker on the DC power system shelf.
...................................................................................................................................................................................................
3 Switch off the AC connector to the DACS and the heaters (CB02, CB04 and CB06 on the
AC box).
...................................................................................................................................................................................................
5 On the left-hand side of the iDACS, disconnect the DC connector and the MCA alarm
connector.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-56 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Direct Ambient Cooling System (DACS) of the
PRELIMINARY
Replacing the cooling system equipment 9311 Macro V1 OD
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
7 Remove the four screws, two on each side, securing the iDACS to the 9311 Macro V1
OD. Remove the loop cable fastener retaining the tempature probe at the back of the 9311
Macro V1 OD.
...................................................................................................................................................................................................
8 Lift the iDACS by the handles located on each side of the iDACS and remove it from the
9311 Macro V1 OD.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-57
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Direct Ambient Cooling System (DACS) of the
Replacing the cooling system equipment 9311 Macro V1 OD
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
9 Place the new iDACS in the 9311 Macro V1 OD and secure it with the four screws (two
on each side).
...................................................................................................................................................................................................
11 On the left-hand side, reconnect the DC connector and the MCA alarm connector.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-58 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS blowers of the 9311 Macro V1 OD
PRELIMINARY
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
Intervention time
20 minutes
Tools required
Screwdriver
CAUTION
Service interruption
This procedure requires a service interruption of the 9311 Macro V1 OD estimated at 20
minutes.
Procedure
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-59
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS blowers of the 9311 Macro V1 OD
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
2 Remove the iDACS. Refer to the “Replacing the Direct Ambient Cooling System
(DACS) of the 9311 Macro V1 OD” (p. 10-55) procedure.
...................................................................................................................................................................................................
...................................................................................................................................................................................................
7 Insert the iDACS. Refer to the “Replacing the Direct Ambient Cooling System (DACS)
of the 9311 Macro V1 OD” (p. 10-55) procedure.
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY
....................................................................................................................................................................................................................................
10-60 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS control board of the 9311 Macro V1 OD
PRELIMINARY
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
Intervention time
30 minutes
Tools required
• Flat screwdriver
• Phillips screwdriver
CAUTION
Service interruption
This procedure requires a service interruption from the 9311 Macro V1 OD for 30
minutes.
CAUTION
New iDACS product reference
When replacing old NTUM81CA module by a new one NTUM81EA module, put the new
reference sticker on the old sticker.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-61
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS control board of the 9311 Macro V1 OD
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-62 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS control board of the 9311 Macro V1 OD
PRELIMINARY
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
Figure 10-21 Location of the iDACS control board in the 9311 Macro V1 OD
...................................................................................................................................................................................................
3 Power down the 9311 Macro V1 OD. Refer to the “Powering down a 9311 Macro V1 OD
with d4U” (p. 8-10) procedure.
...................................................................................................................................................................................................
4 Remove the iDACS. Refer to the “Replacing the Direct Ambient Cooling System
(DACS) of the 9311 Macro V1 OD” (p. 10-55) procedure.
...................................................................................................................................................................................................
5 Loosen the eight screws of the case which contains the iDACS control board. This case is
situated on the side of the iDACS.
...................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-63
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS control board of the 9311 Macro V1 OD
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
8 Disconnect all the cables from the iDACS control board and mark them.
...................................................................................................................................................................................................
9 Loosen the six screws which maintain the iDACS control board in the case.
...................................................................................................................................................................................................
...................................................................................................................................................................................................
12 Tighten the six screws which maintain the iDACS control board in the case.
....................................................................................................................................................................................................................................
10-64 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS control board of the 9311 Macro V1 OD
PRELIMINARY
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
13 Reconnect all the cables from the iDACS control board following the marks.
...................................................................................................................................................................................................
15 Tighten the eight screws of the case which contains the iDACS control board.
...................................................................................................................................................................................................
16 Insert the iDACS. Refer to the “Replacing the Direct Ambient Cooling System (DACS)
of the 9311 Macro V1 OD” (p. 10-55) procedure.
...................................................................................................................................................................................................
17 Power up the 9311 Macro V1 OD. Refer to the “Powering up a 9311 Macro V1 OD with
d4U” (p. 8-2) procedure.
...................................................................................................................................................................................................
18 Stick the label on the iDACS case for modify the product reference code (PEC code).
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-65
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS heaters of the 9311 Macro V1 OD
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
Intervention time
20 minutes
Tools required
screwdriver
CAUTION
Service interruption
This procedure requires a service interruption of the 9311 Macro V1 OD estimated at 20
minutes.
Procedure
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-66 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS heaters of the 9311 Macro V1 OD
PRELIMINARY
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
2 Remove the iDACS. Refer to the “Replacing the Direct Ambient Cooling System
(DACS) of the 9311 Macro V1 OD” (p. 10-55) procedure.
...................................................................................................................................................................................................
11 Insert the iDACS. Refer to the “Replacing the Direct Ambient Cooling System (DACS)
of the 9311 Macro V1 OD” (p. 10-55) procedure.
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-67
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS air filter of the 9311 Macro V1 OD
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
Intervention time
Ten minutes
Tools required
Screwdriver
Procedure
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-68 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS air filter of the 9311 Macro V1 OD
PRELIMINARY
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
...................................................................................................................................................................................................
4 Unscrew the four 1/4 turn fixings of the filter holder and remove the holder.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-69
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS air filter of the 9311 Macro V1 OD
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
7 Replace the filter holder and secure it with the four 1/4 turn fixings.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-70 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Overview
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Overview
Purpose
This section presents the replacement procedures applicable to the power system.
Contents
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-71
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the dc power system shelf
Replacing the power system equipment
....................................................................................................................................................................................................................................
Intervention time
One hour
Tools required
Open wrench
Procedure
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-72 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the dc power system shelf
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Figure 10-26 Location of the dc power system shelf in the 9311 Macro V1 OD
...................................................................................................................................................................................................
3 CAUTION
Service Interruption
This procedure requires a service interruption from the 9311 Macro V1 OD at one hour.
Power down the BTS. Refer to the “Powering down a 9311 Macro V1 OD with d4U”
(p. 8-10) procedure.
...................................................................................................................................................................................................
4 Loosen the two front panel screws of all the rectifiers (or fillers) and remove them except
for the one located on the right-hand side: it will be useful to have the handles of this
rectifier to remove the dc power system shelf.
...................................................................................................................................................................................................
5 On the SPCM, disconnect the thermal probe connector and the alarm bus cable.
...................................................................................................................................................................................................
PRELIMINARY
6 Using an open wrench, remove the four nuts securing the dc power system shelf to the
9311 Macro V1 OD.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-73
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the dc power system shelf
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
7 Lift the dc power system shelf using the handles of the remaining rectifiers/fillers and of
the SPCM. Remove it.
...................................................................................................................................................................................................
9 Insert one rectifier or filler on the right-hand side of the dc power system shelf and secure
it with the two front panel screws.
...................................................................................................................................................................................................
10 Using the rectifier/filler handle and the SPCM handle, replace the dc power system shelf
in the 9311 Macro V1 OD.
...................................................................................................................................................................................................
11 Tighten, with a wrench, the four nuts securing the dc power system shelf to the 9311
Macro V1 OD.
...................................................................................................................................................................................................
12 Replace all the rectifiers/fillers and secure them with the two front panel screws.
...................................................................................................................................................................................................
13 At the front of the SPCM, reconnect: the thermal probe connector and the alarm bus
cable.
...................................................................................................................................................................................................
14 Perform the operations for return to service. Refer to the “Powering up a 9311 Macro V1
OD with d4U” (p. 8-2) procedure.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-74 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the filtering box
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Intervention time
20 minutes
Tools required
• Flat screwdriver
• Phillips screwdriver
• 10mm open wrench
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-75
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the filtering box
Replacing the power system equipment
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-76 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the filtering box
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Figure 10-28 Front view of the split-phase filtering box (US)
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-77
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the filtering box
Replacing the power system equipment
....................................................................................................................................................................................................................................
Figure 10-29 Front view of the split-phase filtering box
PRELIMINARY
....................................................................................................................................................................................................................................
10-78 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the filtering box
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Figure 10-30 Front view of the triphase filtering box
Procedure
...................................................................................................................................................................................................
1 CAUTION
PRELIMINARY
Service interruption
The service will be interrupted if the batteries are not present or discharged.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-79
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the filtering box
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
2 CAUTION
Electric-shock hazard
Personnel safety rules: the personnel performing this check must wear rubber gloves and
must be isolated from the ground.
The 9311 Macro V1 OD remains supplied with the mains power supply.
There is a risk of sparks during the test.
4 Loosen the two screws located at the top of the filtering box (use the Philips screwdriver).
...................................................................................................................................................................................................
PRELIMINARY
5 Extract the defective filtering box with the handle and remove it.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-80 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the filtering box
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
7 Tighten the two securing screws located at the top of the filtering box.
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-81
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a lightning protector of the ac filter box
Replacing the power system equipment
....................................................................................................................................................................................................................................
Intervention time
Five minutes
Tools required
Screwdriver
Procedure
...................................................................................................................................................................................................
4 Loosen the four fixing screws at the bottom of the ac filter box and open the box: the
lightning protectors are located inside.
PRELIMINARY
....................................................................................................................................................................................................................................
10-82 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a lightning protector of the ac filter box
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-83
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a lightning protector of the ac filter box
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
5 Identify the faulty lightning protector: the color of its rectangular mechanical indicator
has turned from white to red.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-84 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a lightning protector of the ac filter box
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
PRELIMINARY
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-85
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a lightning protector of the ac filter box
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
8 Put the ac filter box front panel back and tighten the four fixing screws.
...................................................................................................................................................................................................
12 Call for the OMC in order to confirm that lightning protection alarm has disappeared and
check that another alarm has not been generated (for example, by one of the six ac circuit
breakers still in the OFF position).
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY
....................................................................................................................................................................................................................................
10-86 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS ac breaker
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Intervention time
30 minutes
Tools required
• Flat screwdriver
• Phillips screwdriver
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-87
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS ac breaker
Replacing the power system equipment
....................................................................................................................................................................................................................................
Figure 10-34 Front view of the 3 iDACS ac breakers with a yellow rocker situated
in the ac distribution module
PRELIMINARY
....................................................................................................................................................................................................................................
10-88 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS ac breaker
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-89
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS ac breaker
Replacing the power system equipment
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-90 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS ac breaker
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
3 CAUTION
Service interruption
This procedure requires a service interruption from the 9311 Macro V1 OD for 30
minutes.
Power down the 9311 Macro V1 OD. Refer to the “Powering down a 9311 Macro V1 OD
with d4U” (p. 8-10) procedure.
...................................................................................................................................................................................................
5 CAUTION
ac distribution module
The ac distribution module is connected to iDACS ac breakers and rectifier ac breakers
cables. Its handling must be done gently.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-91
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS ac breaker
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
7 Loosen the two screws on the back of iDACS ac breaker which maintain the two iDACS
ac breaker cables.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-92 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS ac breaker
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
14 Tighten the two screws on the back of iDACS ac breaker which maintain the two iDACS
ac breaker cables.
...................................................................................................................................................................................................
17 Power up the 9311 Macro V1 OD. Refer to the “Powering up a 9311 Macro V1 OD with
d4U” (p. 8-2) procedure.
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-93
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Single Power Control Module (SPCM)
Replacing the power system equipment
....................................................................................................................................................................................................................................
Intervention time
Ten minutes
Tools required
Screwdriver
PRELIMINARY
....................................................................................................................................................................................................................................
10-94 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Single Power Control Module (SPCM)
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-95
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Single Power Control Module (SPCM)
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
2 Disconnect the two connectors at the front of the SPCM: Bus alarm and Thermal probe.
...................................................................................................................................................................................................
7 Check the state of the LEDs. They should go on, then take the following states.
green LED ON, red SPCM Fail, Thermal Probe Fail, REC Fail, and CEATS LEDs OFF
...................................................................................................................................................................................................
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
10-96 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a rectifier
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Replacing a rectifier
Purpose
Carry out the following procedure to replace a rectifier.
Intervention time
Ten minutes
Tools required
Screwdriver
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-97
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a rectifier
Replacing the power system equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
...................................................................................................................................................................................................
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
8 Check the state of the LED. It should go on, then take the following state:
green LED ON
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-99
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the rectifier ac breaker
Replacing the power system equipment
....................................................................................................................................................................................................................................
Intervention time
30 minutes
Tools required
• Flat screwdriver
• Phillips screwdriver
PRELIMINARY
....................................................................................................................................................................................................................................
10-100 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the rectifier ac breaker
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Figure 10-41 Front view of the 3 rectifiers ac breakers with a blue rocker situated
in the ac distribution module
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-101
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the rectifier ac breaker
Replacing the power system equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
...................................................................................................................................................................................................
3 CAUTION
Service interruption
This procedure requires a service interruption from the 9311 Macro V1 OD for 30
minutes.
Power down the 9311 Macro V1 OD. Refer to the “Powering down a 9311 Macro V1 OD
with d4U” (p. 8-10) procedure.
...................................................................................................................................................................................................
CAUTION
PRELIMINARY
5
ac distribution module
The ac distribution module is connected to iDACS ac breakers and rectifier ac breakers
cables. Its handling must be done gently.
....................................................................................................................................................................................................................................
10-102 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the rectifier ac breaker
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Remove gently the ac distribution module.
...................................................................................................................................................................................................
...................................................................................................................................................................................................
7 Loosen the two screws on the back of rectifier ac breaker which maintain the two rectifier
ac breaker cables.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-103
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the rectifier ac breaker
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
14 Tighten the two screws on the back of rectifier ac breaker which maintain the two rectifier
ac breaker cables.
...................................................................................................................................................................................................
17 Power up the 9311 Macro V1 OD. Refer to the “Powering up a 9311 Macro V1 OD with
d4U” (p. 8-2) procedure.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-104 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the DC Breaker Panel
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Intervention time
15 minutes
Tools required
Screwdrivers
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-105
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the DC Breaker Panel
Replacing the power system equipment
....................................................................................................................................................................................................................................
Figure 10-45 DC Breaker Panel - detailed view
Procedure
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
10-106 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the DC Breaker Panel
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
4 Disconnect the cables from the DC breaker front panel and mark them.
...................................................................................................................................................................................................
5 Remove the RF ICO front plate (loosen screws) to access to the RF ICO busbar.
...................................................................................................................................................................................................
6 Disconnect the DC0V and -48V RF0 from the RF ICO busbar.
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-107
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the DC Breaker Panel
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-108 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the batteries of the 9311 Macro V1 OD
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Intervention time
20 minutes
Tools required
Screwdriver
DANGER
Electric-shock hazard
Personnel safety rules: the personnel performing this check must wear rubber gloves and
must be isolated from the ground.
The BTS remains supplied with the mains power supply.
There is a risk of sparks during the test.
Procedure
...................................................................................................................................................................................................
2 Put the Battery circuit breaker on the DC distribution module in OFF position.
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-109
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the batteries of the 9311 Macro V1 OD
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
4 Loosen the four screws retaining the plastic cover in front of the batteries and remove it.
...................................................................................................................................................................................................
6 Loosen the two screws retaining the plastic cover in front of the terminal block and
remove it.
...................................................................................................................................................................................................
9 Remove the thermal probe connected on the right-most battery (top connector).
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-110 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the batteries of the 9311 Macro V1 OD
PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
11 Unscrew the two wing nuts retaining the battery support and the two metal rods and
remove them.
...................................................................................................................................................................................................
14 Replace the four batteries and the three separation pieces in the cabinet.
...................................................................................................................................................................................................
15 Put in place the battery support and the two metal rods and secure them by tightening the
two wing nuts.
...................................................................................................................................................................................................
16 Reconnect the thermal probe on the top connector of the right-most battery.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-111
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the batteries of the 9311 Macro V1 OD
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-112 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Overview
PRELIMINARY
Replacing the optional equipment
....................................................................................................................................................................................................................................
Overview
Purpose
This section presents the other replacement procedures of modules which are not
contained in the digital shelf and the RF block.
Contents
Replacing the Manufacturing Commissioning and Alarm (MCA) module of the 10-114
9311 Macro V1 OD
Replacing the alarm protection module 10-118
Replacing the Pulse Code Modulation (PCM) protection module of the 9311 10-121
Macro V1 OD
9311 Macro V1 OD with d4U: Replacing the double TMA module 10-123
9311 Macro V1 OD with d4U: Replacing the light TMA/AISG TMA module 10-128
Replacing the Interconnection Module of the 9311 Macro V1 OD with d4U 10-134
Node B
Replacing the anti-sliding strips of 9311 Macro V1 OD cable cover 10-137
Replacing the DC Surge Protection Box, if used 10-142
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-113
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Manufacturing Commissioning and Alarm
Replacing the optional equipment (MCA) module of the 9311 Macro V1 OD
....................................................................................................................................................................................................................................
Intervention time
Ten minutes
Tools required
Flat and Phillips screwdrivers
Figure 10-47 Front view of the MCA module in the 9311 Macro V1 OD
CAUTION
Service Interruption
The disconnection of the PCM cable is going to cause a service interruption of the 9311
Macro V1 OD.
Procedure
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
10-114 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Manufacturing Commissioning and Alarm
PRELIMINARY
Replacing the optional equipment (MCA) module of the 9311 Macro V1 OD
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-115
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Manufacturing Commissioning and Alarm
Replacing the optional equipment (MCA) module of the 9311 Macro V1 OD
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
PRELIMINARY
9 The CCM should be able to detect the new MCA and automatically load the I & C data
stored on the previous MCA.
....................................................................................................................................................................................................................................
10-116 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Manufacturing Commissioning and Alarm
PRELIMINARY
Replacing the optional equipment (MCA) module of the 9311 Macro V1 OD
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-117
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the alarm protection module
Replacing the optional equipment
....................................................................................................................................................................................................................................
Intervention time
Ten minutes
Tools required
Screwdriver
Wrench for hexagonal head nut (M6 nut)
PRELIMINARY
....................................................................................................................................................................................................................................
10-118 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the alarm protection module
PRELIMINARY
Replacing the optional equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-119
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the alarm protection module
Replacing the optional equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
4 Remove the two connectors from the bulkhead and undo the wiring.
...................................................................................................................................................................................................
10 Reconnect the two connectors to the bulkhead and redo the wiring.
...................................................................................................................................................................................................
11 Check with the OMC administrator that all alarms are OK.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-120 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Pulse Code Modulation (PCM) protection
PRELIMINARY
Replacing the optional equipment module of the 9311 Macro V1 OD
....................................................................................................................................................................................................................................
Intervention time
15 minutes
Tools required
• Screwdrivers
• Wrenches for hexagonal head (M6 nut)
Procedure
...................................................................................................................................................................................................
2 CAUTION
Service interruption
This procedure requires a service interruption of the 9311 Macro V1 OD.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-121
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Pulse Code Modulation (PCM) protection
Replacing the optional equipment module of the 9311 Macro V1 OD
....................................................................................................................................................................................................................................
Figure 10-52 Location of the PCM protection module into the 9311 Macro V1 OD
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-122 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the double TMA
PRELIMINARY
Replacing the optional equipment module
....................................................................................................................................................................................................................................
Intervention time
15 minutes
Tools required
• 7/16 torque wrench
• 13-mm open wrench
• Flat screwdriver
• Phillips screwdriver
Note: Tightening torques are specified within the procedure.
The following figure shows the double TMA set-up diagram.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-123
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the double TMA
Replacing the optional equipment module
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-124 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the double TMA
PRELIMINARY
Replacing the optional equipment module
....................................................................................................................................................................................................................................
CAUTION
RF hazard
RF exposure in excess of applicable limits can result in serious personal injury.
Observe the following:
• Turn off and lockout the transmit power before working on the antenna system.
• If the transmitters must be tested with the antennas connected, adhere to appropriate
antenna safety distances.
• Do not use auxiliary antennas.
• Consult with the Antenna exposure statements before beginning work.
NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
Procedure
...................................................................................................................................................................................................
2 If the Node B is operational and connected to the OMC, ask the OMC administrator to
lock the sector associated with the faulty TMA (by Set Administrative State). For more
information, please refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-125
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the double TMA
Replacing the optional equipment module
....................................................................................................................................................................................................................................
• DIV BTS
• DIV ANT
...................................................................................................................................................................................................
4 Disconnect the four RF cables from the TMA using the torque wrench.
...................................................................................................................................................................................................
6 Disconnect the ground cable by loosening the nut from the TMA using the 13-mm
wrench.
...................................................................................................................................................................................................
7 On the support plate, untighten the four screws on the support side by using the Phillips
screwdriver.
...................................................................................................................................................................................................
8 Untighten the four nuts which firmly anchor the TMA to the support plate, and remove
the faulty TMA module.
...................................................................................................................................................................................................
9 Append the new TMA module and fix it to the support side with all four screws.
...................................................................................................................................................................................................
10 Tighten the four nuts to firmly anchor the TMA to the support plate.
...................................................................................................................................................................................................
12 Remove the screw, the two flat washers, and the split washer. Take care not to lose items
during the removal.
...................................................................................................................................................................................................
14 Connect the ground cable to the TMA by assembling the following components in the
following order:
PRELIMINARY
• Flat washer
• Eyelet terminal
• Flat washer
....................................................................................................................................................................................................................................
10-126 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the double TMA
PRELIMINARY
Replacing the optional equipment module
....................................................................................................................................................................................................................................
• Split washer
• Hexagonal nut
...................................................................................................................................................................................................
15 Tighten the ground cable using the 13-mm wrench. Check that the other end of the cable
is connected to an efficient ground point.
...................................................................................................................................................................................................
18 Tighten the RF connectors to the TMA using the torque wrench, setting the torque to the
maximum value recommended by the supplier of the 7/16 male connector.
Note: Tighten with 25 N.m in case there is no detailed instruction available from the
connector manufacturer.
Result: The TMA is installed with all connections completed.
...................................................................................................................................................................................................
19 Ask the OMC administrator to unlock the sector associated with the faulty TMA and
previously locked on step 2.
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-127
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the light TMA/AISG
Replacing the optional equipment TMA module
....................................................................................................................................................................................................................................
Intervention time
15 minutes
Tools required
• 7/16 torque wrench
• 13-mm open wrench
• 17-mm torque wrench
• Cutting pliers
Note: Tightening torques are specified within the procedure.
The following figure shows the light TMA set-up diagram.
PRELIMINARY
....................................................................................................................................................................................................................................
10-128 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the light TMA/AISG
PRELIMINARY
Replacing the optional equipment TMA module
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-129
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the light TMA/AISG
Replacing the optional equipment TMA module
....................................................................................................................................................................................................................................
WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.
Important! Only authorized personnel, with adequate technical training and expertise
with radio base systems will be permitted to operate on the various units. Opening of
enclosed units is not permitted.
CAUTION
RF hazard
RF exposure in excess of applicable limits can result in serious personal injury.
Observe the following:
• Turn off and lockout the transmit power before working on the antenna system.
• If the transmitters must be tested with the antennas connected, adhere to appropriate
antenna safety distances.
• Do not use auxiliary antennas.
• Consult with the Antenna exposure statements before beginning work.
NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
You must notify the OMC administrator.
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
PRELIMINARY
Important! Observe the general safety precaution against injury and equipment
damage outlined in the regional installation safety manual at all times.
....................................................................................................................................................................................................................................
10-130 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the light TMA/AISG
PRELIMINARY
Replacing the optional equipment TMA module
....................................................................................................................................................................................................................................
Appropriate precautions must be taken to guarantee the safety of staff and equipment.
All operations to perform the connection of the TMA module to the Node B must be
done according to the safety instructions; please contact your Node B supplier for
valid instruction.
Procedure
...................................................................................................................................................................................................
2 If the Node B is operational and connected to the OMC, ask the OMC administrator to
lock the sector associated with the faulty TMA (by Set Administrative State). For more
information, please refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................
4 Disconnect the ground cable by loosening the nut from the TMA using the 13-mm open
wrench.
...................................................................................................................................................................................................
5 Disconnect the four jumper cables from the TMA RF connectors using the 7/16 torque
wrench.
Note: For AISG TMA, disconnect the AISG cable using the 7/16 torque wrench.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-131
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the light TMA/AISG
Replacing the optional equipment TMA module
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
12 Move the steel band into the openings of the TMA mounting equipment.
...................................................................................................................................................................................................
13 Tighten the hose clamp screws carefully. Do not over tighten them.
...................................................................................................................................................................................................
PRELIMINARY
14 Connect the four jumper cables to the TMA RF connectors using the 7/16 torque wrench.
....................................................................................................................................................................................................................................
10-132 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the light TMA/AISG
PRELIMINARY
Replacing the optional equipment TMA module
....................................................................................................................................................................................................................................
Note: Tightening torques must be the following:
• 25-30 N.m (35-40 Ibf ft) for 7/16 connectors
• 6 N.m (8 Ibf ft) for N-type connectors
...................................................................................................................................................................................................
15 For AISG TMA, reconnect the AISG cable using the 7/16 torque wrench. Tightening
torque is 25-30 N.m (35-40 Ibf ft).
Result: The TMA is installed when all connections are completed.
...................................................................................................................................................................................................
16 Reconnect the ground cable using the 13-mm open wrench. Tightening torque is 5 N.m
(3.7 Ibf ft).
...................................................................................................................................................................................................
17 Ask the OMC administrator to unlock the sector associated with the faulty TMA and
previously locked on step 2.
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-133
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Interconnection Module of the 9311 Macro V1
Replacing the optional equipment OD with d4U Node B
....................................................................................................................................................................................................................................
Intervention time
40 minutes
Tools required
• Flat and Phillips screwdrivers
• 7mm open wrench
Figure 10-56 Front view of the Interconnection module in the 9311 Macro V1 OD
Procedure
...................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
10-134 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Interconnection Module of the 9311 Macro V1
PRELIMINARY
Replacing the optional equipment OD with d4U Node B
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
3 CAUTION
Service Interruption
Disconnecting the cables from the Interconnection module will cause a service
interruption of the 9311 Macro V1 OD.
7 Mark then disconnect the three cables (-48 V, 0V, GND) from the DC power bus bar, and
the two cables (-48V, 0V) to the DC breaker, by unscrewing the nuts.
PRELIMINARY
...................................................................................................................................................................................................
8 Change the Interconnection module by the new one and check the fuses are in place.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-135
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Interconnection Module of the 9311 Macro V1
Replacing the optional equipment OD with d4U Node B
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
9 Reconnect the three cables to the DC power bus bar screwing the nuts and following the
marks.
...................................................................................................................................................................................................
13 Reconnect all cables to D-sub and RJ45 front pannel connectors following the marks.
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
10-136 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the anti-sliding strips of 9311 Macro V1 OD cable
PRELIMINARY
Replacing the optional equipment cover
....................................................................................................................................................................................................................................
Detection process
Intervention time
One hour
Tools required
• Rework kit (PEC code: NTUM99XA) consisting in 2 self-adhesive strips
PRELIMINARY
DANGER
Staff Safety
Any operation on an outside site is forbidden in case of thunder storm, heavy rain or high
wind.
Wear gloves during the application of the present procedure.
Respect solvent safety datasheet before using it on site.
Conform to general safety precautions against personnel injury stated in the local
installer's regulations.
Conform to all rules related to the premises and country specific.
CAUTION
The 9311 Macro V1 OD remains supplied with the mains power
supply.
Wear the antistatic bracelet when performing the maintenance procedure described
below.
CAUTION
Equipment Safety
Conform to general safety precautions against equipment damage stated in the local
regulations.
Be careful not to damage cabinet external frames which are responsible for the overall
appearance of the cabinet, especially make sure of the type of solvent used.
Prefer good weather conditions to perform the cable cover rework operation.
PRELIMINARY
....................................................................................................................................................................................................................................
10-138 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the anti-sliding strips of 9311 Macro V1 OD cable
PRELIMINARY
Replacing the optional equipment cover
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
PRELIMINARY
...................................................................................................................................................................................................
2 Using cloth and solvent, remove all glue residue from old strips so to obtain a clean
surface.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-139
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the anti-sliding strips of 9311 Macro V1 OD cable
Replacing the optional equipment cover
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
3 Wait until the surface is dry. Start applying the new self-adhesive strip at one end (do not
remove the whole protective paper).
PRELIMINARY
...................................................................................................................................................................................................
4 Align the whole strip along the cable cover and then remove the protective paper. Press
on the strip to ensure it is perfectly stuck. Repeat steps 3 and 4 for the second strip.
....................................................................................................................................................................................................................................
10-140 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the anti-sliding strips of 9311 Macro V1 OD cable
PRELIMINARY
Replacing the optional equipment cover
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
5 Clean-up the site before leaving. The following figure shows the final result.
PRELIMINARY
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-141
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the DC Surge Protection Box, if used
Replacing the optional equipment
....................................................................................................................................................................................................................................
Intervention time
15 minutes
Tools required
Screwdrivers
....................................................................................................................................................................................................................................
10-142 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the DC Surge Protection Box, if used
PRELIMINARY
Replacing the optional equipment
....................................................................................................................................................................................................................................
DC Box, in configuration with d4U Node B
Figure 10-60 DC Box connections, with the d4U Node B and the left bulkhead
Note: The DC box is located outside the cabinet, mounted normally on a mast or wall.
CAUTION
Service Interruption
Shutdown of the RRH is going to cause a service interruption of the 9311 Macro V1 OD.
CAUTION
Service Interruption
The RRH and associated cells must be locked before attempting to change the DC box.
Procedure
PRELIMINARY
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-143
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the DC Surge Protection Box, if used
Replacing the optional equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
10-144 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the DC Surge Protection Box, if used
PRELIMINARY
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-145
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the DC Surge Protection Box, if used
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
10-146 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
Appendix A: 9326 d2U
Commissioning,
Decommissioning
Overview
Purpose
This appendix provides instructions to power up and power down the 9326 d2U.
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary A-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9326 d2U Commissioning, Decommissioning Powering up a 9926 d4U Node B
....................................................................................................................................................................................................................................
Initial check
On the RUC module, check that the power switch is in the "O" position.
Procedure
...................................................................................................................................................................................................
1 At the operator DC power supply, put the site circuit breaker of the 9926 d4U Node B in
the "ON" position.
...................................................................................................................................................................................................
2 On the RUC module, put the power switch in the "1" position.
...................................................................................................................................................................................................
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY
....................................................................................................................................................................................................................................
A-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9326 d2U Commissioning, Decommissioning Powering down the 9926 d4U Node B
PRELIMINARY
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................
2 On the RUC V5 module, put the power switch "1/0" (ON/OFF) to the ""0" (OFF)"
position.
...................................................................................................................................................................................................
3 Check that all LEDs on the eCCM-U or xCCM-U and on each eCEM-U or xCEM-U are
OFF.
...................................................................................................................................................................................................
5 At the operator DC power supply, put the site circuit breaker of the 9926 d4U Node B in
the "OFF" position.
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary A-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9326 d2U Commissioning, Decommissioning Powering down the 9926 d4U Node B
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
A-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
Appendix B: Product
conformance statements
Overview
Purpose
This appendix provides the product conformance statements for a Macro V1 Node B
Outdoor with 9926 d4U in the digital shelf.
Contents
PRELIMINARY
...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary B-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Product conformance statements European regulatory requirement compliance
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
Compliance with the essential requirement of health requirement has been
demonstrated using EN50385.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary B-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Product conformance statements Compliances for other regions/countries
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
B-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Product conformance statements Operational conditions
PRELIMINARY
....................................................................................................................................................................................................................................
Operational conditions
Overview
The aforementioned standards compliance of the products are based on the following
operating conditions (called normal operation):
• Doors shall be closed and/or covers shall be in place.
• External cables shall be of the same type as specified by Alcatel-Lucent.
• No modification of any mechanical or electrical characteristics of the product shall be
made.
Any change or modification made to the product without written approval from
Alcatel-Lucent releases Alcatel-Lucent from subsequent responsibility regarding the
standards compliance.
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary B-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Product conformance statements Cable specifications
....................................................................................................................................................................................................................................
Cable specifications
Overview
The compliance to the aforementioned standards has been verified using cables as
specified by Alcatel-Lucent. The continuing compliance of the product relies upon use of
the correct cabling scheme as well as use of identical type cables as specified by
Alcatel-Lucent. Refer to the installation guides for details on cable specifications.
PRELIMINARY
....................................................................................................................................................................................................................................
B-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Product conformance statements Product labelling
PRELIMINARY
....................................................................................................................................................................................................................................
Product labelling
Overview
The label may be located inside or outside the product, provided that the operation and/or
maintenance personnel have the information when working on the product.
On the regulatory label, compliance to 47 CFR Part 15, 22 or 24, and 68 is stated along
with:
• FCC ID, FCC Registration Number
• Manufacturers name
• Equipment designation
• Nominal voltage operating range and maximum rated current.
• Manufacturers name
PRELIMINARY
• Equipment designation
• Nominal voltage operating range and maximum rated current
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary B-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Product conformance statements Product labelling
....................................................................................................................................................................................................................................
Labelling for other regions/countries
Labelling for other regions and countries is performed as appropriate and required by the
local regulatory framework.
PRELIMINARY
....................................................................................................................................................................................................................................
B-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Index
PRELIMINARY
E eCCM-U ............................................................. Small Form-factor Pluggable
See: enhanced Core Controller (SFP)
O Optional Supported Network
Module-U (eCCM-U)
Configurations, 1-5 replace, 10-19
eCEM-U
NodeB dropping 2G BTS, 1-6 .............................................................
See: enhanced Channel
Element Module-U NodeB dropping 3G NodeB, X xCCM-U
(eCEM-U) 1-5 See: extended Core Controller
enhanced Channel Element Module-U (xCCM-U)
NodeB dropping 4G eNodeB,
Module-U (eCEM-U) 1-6 xCEM-U
front view, 10-4 See: extended Channel
.............................................................
Element Module-U
replace, 10-4 P pre-cabled rack (xCEM-U)
enhanced Core Controller replace, 10-31
Module-U (eCCM-U)
.............................................................
eCCM-U-GE front view, 10-10
R replace
replace, 10-10
enhanced Core Controller
extended Channel Element
Module-U (eCCM-U), 10-10
Module-U (xCEM-U)
extended Core Controller
front view, 10-4
Module-U (xCCM-U), 10-10
replace, 10-4
fan rack module, 10-24
extended Core Controller
pre-cabled rack, 10-31
Module-U (xCCM-U)
Small Form-factor Pluggable
replace, 10-10
(SFP), 10-19
xCCM-U-GE front view, 10-10
.............................................................
.............................................................
S Safety statements, 2-1, 2-2
PRELIMINARY
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary IN-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Index
....................................................................................................................................................................................................................................
PRELIMINARY
....................................................................................................................................................................................................................................
IN-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013