You are on page 1of 240

Use pursuant to applicable agreements

PRELIMINARY
Title page

Alcatel-Lucent 9311
Macro V1 Node B Outdoor with 9926 d4U
Maintenance Guide
3MN-00475-0006-REZZA
Issue 1.03 | June 2013

PRELIMINARY

Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Use pursuant to applicable agreements

Legal notice
PRELIMINARY
Legal notice

Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.

The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright © 2013 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside
Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.
PRELIMINARY

Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
Contents

PRELIMINARY
About this document
Purpose .......................................................................................................................................................................................... xiii
xiii

Reason for reissue ...................................................................................................................................................................... xiv


xiv

Intended audience ...................................................................................................................................................................... xiv


xiv

Supported systems ..................................................................................................................................................................... xiv


xiv

How to use this document ....................................................................................................................................................... xiv


xiv

Safety information ..................................................................................................................................................................... xiv


xiv

Prerequisites .................................................................................................................................................................................. xv
xv

Conventions used ......................................................................................................................................................................... xv


xv

Related information .................................................................................................................................................................... xv


xv

Document support ...................................................................................................................................................................... xvi


xvi

Technical support ...................................................................................................................................................................... xvii


xvii

How to order ............................................................................................................................................................................... xvii


xvii

How to comment ....................................................................................................................................................................... xvii


xvii

1 UTRAN introduction

Overview ...................................................................................................................................................................................... 1-1


1-1

UTRAN introduction ............................................................................................................................................................... 1-2


1-2

2 Safety statements

Overview ...................................................................................................................................................................................... 2-1


2-1

Structure of safety statements ............................................................................................................................................... 2-2


2-2
PRELIMINARY

3 Preventive maintenance activity

Overview ...................................................................................................................................................................................... 3-1


3-1

Preventive maintenance activity .......................................................................................................................................... 3-2


3-2
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary iii
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Contents

....................................................................................................................................................................................................................................
4 Corrective maintenance activity

Overview ...................................................................................................................................................................................... 4-1


4-1

Corrective maintenance activity .......................................................................................................................................... 4-2


4-2

5 Macro V1 Node B Outdoor with 9926 d4U: Introduction

Overview ...................................................................................................................................................................................... 5-1


5-1

9311 Macro V1 OD introduction ........................................................................................................................................ 5-2


5-2

6 9311 Macro V1 OD hardware presentation

Overview ...................................................................................................................................................................................... 6-1


6-1

Hardware presentation for 9311 Macro V1 OD with d4U digital shelf configuration .................................... 6-2
6-2

d4U Node B in a Dual Node B Configuration ............................................................................................................... 6-4


6-4

7 Checking the door alarm

Overview ...................................................................................................................................................................................... 7-1


7-1

Checking the door alarm ........................................................................................................................................................ 7-2


7-2

8 9311 Macro V1 OD power up and power down procedures

Overview ...................................................................................................................................................................................... 8-1


8-1

Powering up a 9311 Macro V1 OD with d4U ................................................................................................................ 8-2


8-2

Powering down a 9311 Macro V1 OD with d4U ....................................................................................................... 8-10


8-10

9 Preventive maintenance procedures

Overview ...................................................................................................................................................................................... 9-1


9-1

Inspecting the Connectors ...................................................................................................................................................... 9-2


9-2

Inspecting the anchor bolts .................................................................................................................................................... 9-5


9-5

Inspecting the AC inlet cable gland ................................................................................................................................... 9-8


9-8

Inspecting the EMC door gasket ......................................................................................................................................... 9-9


9-9
PRELIMINARY

10 Corrective maintenance procedures

Overview ................................................................................................................................................................................... 10-1


10-1

....................................................................................................................................................................................................................................
iv Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Contents

PRELIMINARY
....................................................................................................................................................................................................................................
Replacing the 9926 d4U digital shelf equipment

Overview ................................................................................................................................................................................... 10-3


10-3

Replacing a CEM ................................................................................................................................................................... 10-4


10-4

Replacing a CCM ................................................................................................................................................................. 10-10


10-10

Replacing an optical transceiver ..................................................................................................................................... 10-19


10-19

Replacing the fan rack module ....................................................................................................................................... 10-24


10-24

Replacing the pre-cabled rack ......................................................................................................................................... 10-31


10-31

Replacing the RF block equipment

Overview ................................................................................................................................................................................. 10-46


10-46

9311 Macro V1 OD with d4U: Replacing a TRDU ................................................................................................ 10-47


10-47

Replacing the cooling system equipment

Overview ................................................................................................................................................................................. 10-54


10-54

Replacing the Direct Ambient Cooling System (DACS) of the 9311 Macro V1 OD ................................. 10-55
10-55

Replacing the iDACS blowers of the 9311 Macro V1 OD ................................................................................... 10-59


10-59

Replacing the iDACS control board of the 9311 Macro V1 OD ........................................................................ 10-61
10-61

Replacing the iDACS heaters of the 9311 Macro V1 OD .................................................................................... 10-66


10-66

Replacing the iDACS air filter of the 9311 Macro V1 OD .................................................................................. 10-68
10-68

Replacing the power system equipment

Overview ................................................................................................................................................................................. 10-71


10-71

Replacing the dc power system shelf ........................................................................................................................... 10-72


10-72

Replacing the filtering box ............................................................................................................................................... 10-75


10-75

Replacing a lightning protector of the ac filter box ................................................................................................. 10-82


10-82

Replacing the iDACS ac breaker ................................................................................................................................... 10-87


10-87
PRELIMINARY

Replacing the Single Power Control Module (SPCM) .......................................................................................... 10-94


10-94

Replacing a rectifier ............................................................................................................................................................ 10-97


10-97

Replacing the rectifier ac breaker ................................................................................................................................ 10-100


10-100

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary v
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Contents

....................................................................................................................................................................................................................................
Replacing the DC Breaker Panel ................................................................................................................................. 10-105
10-105

Replacing the batteries of the 9311 Macro V1 OD ............................................................................................... 10-109


10-109

Replacing the optional equipment

Overview .............................................................................................................................................................................. 10-113


10-113

Replacing the Manufacturing Commissioning and Alarm (MCA) module of the 9311 Macro V1
OD ................................................................................................................................................................................... 10-114
10-114

Replacing the alarm protection module ..................................................................................................................... 10-118


10-118

Replacing the Pulse Code Modulation (PCM) protection module of the 9311 Macro V1 OD ............ 10-121
10-121

9311 Macro V1 OD with d4U: Replacing the double TMA module .............................................................. 10-123
10-123

9311 Macro V1 OD with d4U: Replacing the light TMA/AISG TMA module ......................................... 10-128
10-128

Replacing the Interconnection Module of the 9311 Macro V1 OD with d4U Node B ............................ 10-134
10-134

Replacing the anti-sliding strips of 9311 Macro V1 OD cable cover ............................................................. 10-137
10-137

Replacing the DC Surge Protection Box, if used ................................................................................................... 10-142


10-142

A 9326 d2U Commissioning, Decommissioning

Overview ..................................................................................................................................................................................... A-1


A-1

Powering up a 9926 d4U Node B ...................................................................................................................................... A-2


A-2

Powering down the 9926 d4U Node B ............................................................................................................................ A-3


A-3

B Product conformance statements

Overview ..................................................................................................................................................................................... B-1


B-1

European regulatory requirement compliance ............................................................................................................... B-2


B-2

Compliances for other regions/countries ......................................................................................................................... B-4


B-4

Operational conditions ........................................................................................................................................................... B-5


B-5

Cable specifications ................................................................................................................................................................ B-6


B-6

Product labelling ...................................................................................................................................................................... B-7


B-7
PRELIMINARY

Index

....................................................................................................................................................................................................................................
vi Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
List of tables

PRELIMINARY
1 Issue 1.03, June 2013, Reason for reissue ........................................................................................................ xiv

2 Issue 1.02, April 2013, Reason for reissue ....................................................................................................... xiv

3 Generic Terms ............................................................................................................................................................... xv


xv

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary vii
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY List of tables

....................................................................................................................................................................................................................................
PRELIMINARY

....................................................................................................................................................................................................................................
viii Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
List of figures

PRELIMINARY
1-1 Alcatel-Lucent UTRAN architecture example ............................................................................................... 1-4

1-2 NodeB dropping 3G NodeB .................................................................................................................................. 1-6

1-3 NodeB dropping 4G eNodeB ................................................................................................................................ 1-6

1-4 NodeB dropping 2G BTS ....................................................................................................................................... 1-7

5-1 9311 Macro V1 OD outside view ........................................................................................................................ 5-3

6-1 9311 Macro V1 OD Inside view .......................................................................................................................... 6-3

6-2 9311 Macro V1 OD Cabinet layout .................................................................................................................... 6-3

6-3 9926 d4U in Dual Controller Hardware Configuration ............................................................................... 6-4

8-1 AC main module: Front panel detail .................................................................................................................. 8-3

8-2 DC Breaker Panel used with the d4U Node B configuration .................................................................... 8-4

8-3 Front view of the DC power system shelf ........................................................................................................ 8-6

8-4 DC Distribution Panel - Front view .................................................................................................................... 8-7

8-5 DC Breaker Panel used with the d4U Node B configuration .................................................................... 8-8

9-1 9311 Macro V1 OD with d4U: STSRx wiring .............................................................................................. 9-3

9-2 Location of anchor bolts ......................................................................................................................................... 9-6

10-1 xCEM-U front panel .............................................................................................................................................. 10-4

10-2 eCEM-U front panel ............................................................................................................................................... 10-5


10-5

10-3 Extracting a CEM ................................................................................................................................................... 10-8


10-8

10-4 xCCM-U-GE configuration front panel ....................................................................................................... 10-10

10-5 eCCM-U-GE configuration front panel ........................................................................................................ 10-10


PRELIMINARY

10-6 Extracting a CCM ................................................................................................................................................. 10-12


10-12

10-7 Location of the DIP switch on the eCCM-U .............................................................................................. 10-14

10-8 DIP switch settings on the eCCM-U ............................................................................................................. 10-15

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary ix
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY List of figures

....................................................................................................................................................................................................................................
10-9 Location of optical connectors in the 9926 d4U Node B ....................................................................... 10-20

10-10 9926 d4U Node B fan rack module view .................................................................................................... 10-24

10-11 Extracting a fan rack module ............................................................................................................................ 10-26

10-12 RUC and fan rack module ................................................................................................................................. 10-27

10-13 Location of the management sticker .............................................................................................................. 10-34

10-14 Extracting the CEM and CCM ........................................................................................................................ 10-36

10-15 TRDU60–21 front panel .................................................................................................................................... 10-48

10-16 TRDU60-21B front panel .................................................................................................................................. 10-49

10-17 Power switch on the TRDU front panel ....................................................................................................... 10-51

10-18 DACS location ....................................................................................................................................................... 10-56


10-56

10-19 iDACS location ..................................................................................................................................................... 10-59


10-59

10-20 iDACS control board ........................................................................................................................................... 10-62

10-21 Location of the iDACS control board in the 9311 Macro V1 OD ...................................................... 10-63

10-22 Location of the connectors of the iDACS control board ........................................................................ 10-64

10-23 iDACS location ..................................................................................................................................................... 10-66


10-66

10-24 iDACS location ..................................................................................................................................................... 10-68


10-68

10-25 Front view of the dc power system shelf ..................................................................................................... 10-72

10-26 Location of the dc power system shelf in the 9311 Macro V1 OD .................................................... 10-73

10-27 Front view of the single phase filtering box ............................................................................................... 10-76

10-28 Front view of the split-phase filtering box (US) ....................................................................................... 10-77

10-29 Front view of the split-phase filtering box .................................................................................................. 10-78

10-30 Front view of the triphase filtering box ........................................................................................................ 10-79

10-31 Location of the filtering box in the 9311 Macro V1 OD ........................................................................ 10-80

10-32 Front view of the ac filter box .......................................................................................................................... 10-83


PRELIMINARY

10-33 Internal view of the ac filter box ..................................................................................................................... 10-85

10-34 Front view of the 3 iDACS ac breakers with a yellow rocker situated in the ac distribution module
....................................................................................................................................................................... 10-8810-88
10-88

....................................................................................................................................................................................................................................
x Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
List of figures

PRELIMINARY
....................................................................................................................................................................................................................................
10-35 Location of the iDACS ac breaker in the 9311 Macro V1 OD ............................................................ 10-90

10-36 Location of the connectors of the iDACS ac breaker .............................................................................. 10-92

10-37 Front view of the SPCM .................................................................................................................................... 10-95

10-38 Location of the SPCM ........................................................................................................................................ 10-96

10-39 Front view of a rectifier ...................................................................................................................................... 10-97

10-40 Location of the rectifier in the 9311 Macro V1 OD ................................................................................. 10-98

10-41 Front view of the 3 rectifiers ac breakers with a blue rocker situated in the ac distribution module
................................................................................................................................................................... 10-10110-101
10-101

10-42 Location of the rectifier ac breaker in the 9311 Macro V1 OD ........................................................ 10-102

10-43 Location of the connectors of the rectifier ac breaker .......................................................................... 10-103

10-44 Location of the DC Breaker Panel in the cabinet ................................................................................... 10-105

10-45 DC Breaker Panel - detailed view ................................................................................................................ 10-106

10-46 Location of the batteries in the 9311 Macro V1 OD ............................................................................. 10-110

10-47 Front view of the MCA module in the 9311 Macro V1 OD ............................................................... 10-114

10-48 Location of the MCA module ........................................................................................................................ 10-115

10-49 MCA of 9311 Macro V1 OD with/without adaptor ............................................................................... 10-116

10-50 Alarm protection module front panel .......................................................................................................... 10-119

10-51 Front view of the PCM protection module ............................................................................................... 10-121

10-52 Location of the PCM protection module into the 9311 Macro V1 OD .......................................... 10-122

10-53 TMA module set-up diagram ......................................................................................................................... 10-124

10-54 Light TMA module set-up diagram ............................................................................................................. 10-129

10-55 Light TMA module ............................................................................................................................................ 10-132

10-56 Front view of the Interconnection module in the 9311 Macro V1 OD ........................................... 10-134

10-57 Location of the Interconnection module in the 9311 Macro V1 OD ............................................... 10-135
PRELIMINARY

10-58 Wear gloves during the clean-up operation .............................................................................................. 10-139

10-59 DC Surge Protection Box - detailed view ................................................................................................. 10-142

10-60 DC Box connections, with the d4U Node B and the left bulkhead ................................................. 10-143

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary xi
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY List of figures

....................................................................................................................................................................................................................................
PRELIMINARY

....................................................................................................................................................................................................................................
xii Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
About this document
About this document

Purpose
The purpose of this document is to describe the preventive and corrective maintenance
procedures applicable to the Alcatel-Lucent 9311 Macro V1 Node B Outdoor cabinet,
with d4U Node B in the digital shelf. Its short name is 9311 Macro V1 OD with d4U.
The 9311 Macro V1 OD with d4U has the following characteristics:
• A 9926 d4U module in the digital shelf, whose main functions are: network interface,
call and signal processing. The d4U can include up to 2 eCCM-U and up to 6
eCEM-U or up to 6 xCEM-U or a compatible mix between eCEM-U/xCEM-U,
• The RF block which contains the front-end RF modules (1 to 6 TRDUs or 1 to 6
RRHs (external)),
• Power system (AC distribution, filtering, rectifiers),
• Cooling system (iDACS),
• Internal alarms,
• The standard network interface of the 9311 Macro OD1 is a maximum of 8 PCM
E1/T1 (E1 PCM120 Ohms/ 75 Ohms, T1 PCM 100 Ohms).
The standard network interface can be an IP Iub and Hybrid Iub (supported by the
eCCM-U into the d4U).
The following units are optional:
• RETA
• External Alarms
• PCM Protection
• TMA
• DC back-up (internal only)
• Material in User Space.
PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary xiii
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY About this document

....................................................................................................................................................................................................................................
Reason for reissue
The reissue history for issue 1.03 is shown in the following table:

Table 1 Issue 1.03, June 2013, Reason for reissue

Location Change
Roadmap chapter removed (AR 1-4535173)

The reissue history for issue 1.02 is shown in the following table.New features are
highlighted.

Table 2 Issue 1.02, April 2013, Reason for reissue

Location: New Features:


“d4U Node B in a Dual Node B Configuration” Feature FRS133975 : Hosting of 2 Nodes
(p. 6-4) Bs in an Alcatel-Lucent 9311 Macro V1
Node B Outdoor :
This new feature will enable operators to
stack two logical Node Bs inside the same
9926 d4U in order to provide higher
signaling capacity.
“Optional Supported Network Configurations” Feature FRS100791 : Multi-technology
(p. 1-5) (2G, 3G or 4G) collocated BTS daisy
chaining through a 3G NodeB

Intended audience
The audience for this document is Operations and Maintenance personnel.

Supported systems
This document is release independent, and applies to all Alcatel-Lucent W-CDMA system
releases.

How to use this document


No specific recommendation applies regarding the way readers should read this
document.
PRELIMINARY

Safety information
For your safety, this document contains safety statements. Safety statements are given at
points where risks of damage to personnel, equipment, and operation may exist. Failure to
follow the directions in a safety statement may result in serious consequences.
....................................................................................................................................................................................................................................
xiv Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
About this document

PRELIMINARY
....................................................................................................................................................................................................................................
Prerequisites
It is recommended that readers become familiar with the following document:
Alcatel-Lucent 9311 Macro V1 Node B Outdoor with 9926 d4U - Technical Description,
3MN-00475-0005-DEZZA.

Conventions used
Vocabulary conventions
For a list of the terms used in this document, see Alcatel-Lucent W-CDMA System -
Terminology, 9YZ-04088-0002-TQZZA.
Some terms are used specifically or generically.

Table 3 Generic Terms

Generic term Used for


CCM xCCM-U/eCCM-U
CEM xCEM-U/eCEM-U
TRDU TRDU60-21/TRDU60-21B

Typographical conventions
The following typographical conventions are used in this document:

Appearance Description
graphical user interface text Text that is displayed in a graphical user interface or
in a hardware label
bold text Emphasized information
Document reference, reference number Related document that is referenced in the document.

Related information
For information on subjects related to the content of this document, refer to the
documents listed in the following table:

Refer to this document At this location For more information on


Alcatel-Lucent W-CDMA http://support.alcatel-lucent. Terms used in Alcatel-Lucent
PRELIMINARY

System - Terminology, com. 9300 W-CDMA documents.


9YZ-04088-0002-TQZZA

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary xv
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY About this document

....................................................................................................................................................................................................................................

Refer to this document At this location For more information on


Alcatel-Lucent 9311 Macro http://support.alcatel- The Alcatel-Lucent 9311
V1 Node B Outdoor with lucent.com Macro V1 Node B Outdoor
d4U Node B - Technical with 9926 d4U Node B:
Description, • Basic characteristics
3MN-00475-0005-DEZZA
• Architecture and
configurations
• Interfaces
• Hardware description
• Upgrade path
Alcatel-Lucent 9353 http://support.alcatel-lucent. Alarm descriptions and
Wireless Management com. maintenance actions required
System - Node B Alarms for Alcatel-Lucent Node Bs
Reference Guide for 9311,
9312, 9322, 9326, 9332
Node B, 9YZ-04088-0060-
UFZZA
Alcatel-Lucent 9100 and http://support.alcatel-lucent. How to perform the Node B
93xx Node B com. installation, commissioning
Commissioning and Fault and maintenance tasks using
Management User Manual: the Node B TIL (Terminal for
TIL , NN-20500-019 Local Installation) tool.
Alcatel-Lucent 9353 http://support.alcatel- How to perform commands
Wireless Management lucent.com available 9353 Wireless
System, User Guide, Management System (WMS)
9YZ-04088-0014-PCZZA Graphical User Interface
(GUI).
Alcatel-Lucent W-CDMA http://support.alcatel-lucent. Safety guidelines and the
System Safety Guide, com. catalog of hazard statements
9YZ-04088-0007-TQZZA that appear in the
Alcatel-Lucent W-CDMA
customer documents.

Document support
For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
PRELIMINARY

one of the following telephone numbers:


• 1-888-582-3688 (for the United States)
• 1-630-224-2485 (for all other countries)

....................................................................................................................................................................................................................................
xvi Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
About this document

PRELIMINARY
....................................................................................................................................................................................................................................
Technical support
For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.

How to order
To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)

How to comment
To comment on this document, go to the Online Comment Form (http://infodoc.alcatel-
lucent.com/comments/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com).

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary xvii
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY About this document

....................................................................................................................................................................................................................................
PRELIMINARY

....................................................................................................................................................................................................................................
xviii Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
1 UTRAN introduction
1

Overview
Purpose
This chapter describes the Universal Mobile Telecommunications System (UMTS)
Terrestrial Radio Access Network (UTRAN).

Contents

UTRAN introduction 1-2

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 1-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY UTRAN introduction UTRAN introduction

....................................................................................................................................................................................................................................

UTRAN introduction
UTRAN components
The UTRAN is composed of at least one Radio Network Subsystem (RNS). An RNS
covers a certain geographical area. It is equivalent to the GSM BSS. Each RNS is
composed of one Radio Network Controller (RNC) and one or more Node Bs. RNSs are
interconnected through the Iur interface of each RNC to form a network.
Alcatel-Lucent UTRAN
The Alcatel-Lucent UTRAN is based on the following components:
• RNC
• Node B
• WMS for the OAM part

RNC
The Alcatel-Lucent RNC is 3GPP-compliant. It is based on the Multiservice Switch
platform.

RNC main functions


The main functions of the RNC are to control and manage:
• Radio Access Network (RAN)
• Signalling between Core Network (CN) components and the Radio Network System
(RNS)
• Node Bs and their radio resources

RNC interfaces
The RNC provides the following interfaces:
• Iub towards a Node B
• Iu towards the Core Network
• Iur towards another RNC
• Iupc towards a Standalone A-GPS SMLC (SAS)

Node B
The Alcatel-Lucent Node Bs are 3GPP-compliant. The Alcatel-Lucent Node B portfolio
PRELIMINARY

includes:
• Conventional unitary base stations
• Digital base stations
• Radio base stations
....................................................................................................................................................................................................................................
1-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
UTRAN introduction UTRAN introduction

PRELIMINARY
....................................................................................................................................................................................................................................
• Radio heads
• Base station routers

Node B main functions


The Node B supports the following main functions:
• Network interface management
• Radio access
• Call processing
• Configuration and supervision
• Synchronization
• Performance monitoring

Node B interfaces
The Node B provides the following interfaces:
• Iub towards an RNC
• Uu towards a UE
• Interface B towards WMS

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 1-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY UTRAN introduction UTRAN introduction

....................................................................................................................................................................................................................................

Figure 1-1 Alcatel-Lucent UTRAN architecture example

WMS
PRELIMINARY

The Alcatel-Lucent Wireless Management System (WMS) delivers an integrated UMTS


management platform through which all Network Elements (NE) can be monitored and
controlled.

....................................................................................................................................................................................................................................
1-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
UTRAN introduction UTRAN introduction

PRELIMINARY
....................................................................................................................................................................................................................................
It plays an important role in providing the foundation of a complete end-to-end
management solution for UMTS networks. The WMS manages the entire UMTS
network, which is divided into:
• The UTRAN
• The Core Network (circuit-switched and packet-switched traffics).
The Access Network OAM manages the UTRAN part of the network.

Access Network OAM main functions


The Access Network OAM manages the UTRAN part of the network.
The main functions of Access Network OAM are the following:
• Fault management
• Configuration management
• Performance management

NSP
The Network Services Platform (NSP) is a graphical user interface to the Access Network
providing a common platform for navigation and control. The NSP interfaces with the
NEs through a Common Object Request Broker Architecture (CORBA). This
vendor-independent architecture links computer applications across different networks.

Optional Supported Network Configurations


From LR13.1.W, BTS daisy chaining through the NodeB allows one GE link to serve a
number of base stations. The base station can be multi-generation of 2G, 3G or 4G. The
number of base stations is limited to 1Gb/s of the GE link or by the capacity of the switch
of the most upstream base station of the chain which must be a 3G NodeB.
The NodeB located upstream in the daisy chain with respect to the position of another
base station B is called the ‘Chaining NodeB’ or the ‘Dropping NodeB’ while base station
B (whatever the generation) is called the ‘Chained base station’ or the ‘Dropped base
station’. The ‘Dropped base station’ is never aware of the daisy chain.
A NodeB can be used for daisy chaining once the software is uploaded in the NodeB. The
feature can be activated without the need to reset the ‘Chaining NodeB’.
The service is managed at the MDA level and makes use of the MAC addressing to
distinguish Chained base station frames from Chaining BTS ones.
PRELIMINARY

This network configuration requires 9926 d4U Node B or d2U NodeB equipped with GE
MDA and full IP backhaul. Besides, only Alcatel-Lucent base stations are supported in
the daisy chain.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 1-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY UTRAN introduction UTRAN introduction

....................................................................................................................................................................................................................................

Figure 1-2 NodeB dropping 3G NodeB

In this configuration, the both NodeBs are managed by the same OMC and RNC.

Figure 1-3 NodeB dropping 4G eNodeB


PRELIMINARY

....................................................................................................................................................................................................................................
1-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
UTRAN introduction UTRAN introduction

PRELIMINARY
....................................................................................................................................................................................................................................
Figure 1-4 NodeB dropping 2G BTS

In this configuration, the 2G BTS has to be configured with ABIS interface over
IP/Ethernet.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 1-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY UTRAN introduction UTRAN introduction

....................................................................................................................................................................................................................................
PRELIMINARY

....................................................................................................................................................................................................................................
1-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
2 Safety statements
2

Overview
Purpose
This chapter provides information on the structure of safety statements which may arise
in the course of your work.

Contents

Structure of safety statements 2-2

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 2-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Safety statements Structure of safety statements

....................................................................................................................................................................................................................................

Structure of safety statements


Overview
This topic describes the components of safety statements that appear in this document.

General structure
Safety statements include the following structural elements:

B C D
CAUTION

MP L E
Lifting hazard E F

SA
Lifting this equipment by yourself can result in injury
due to the size and weight of the equipment.
G
Always use three people or a lifting device to transport
and position this equipment. [ABC123]
H
Item Structure element Purpose
1 Safety alert symbol Indicates the potential for personal injury
(optional)
2 Safety symbol Indicates hazard type (optional)
3 Signal word Indicates the severity of the hazard
4 Hazard type Describes the source of the risk of damage or
injury
5 Safety message Consequences if protective measures fail
6 Avoidance message Protective measures to take to avoid the hazard
7 Identifier The reference ID of the safety statement
(optional)
PRELIMINARY

....................................................................................................................................................................................................................................
2-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Safety statements Structure of safety statements

PRELIMINARY
....................................................................................................................................................................................................................................
Signal words
The signal words identify the hazard severity levels as follows:

Signal word Meaning


DANGER Indicates an extremely hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION Indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE Indicates a hazardous situation not related to personal injury.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 2-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Safety statements Structure of safety statements

....................................................................................................................................................................................................................................
PRELIMINARY

....................................................................................................................................................................................................................................
2-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
3 3reventive maintenance
P
activity

Overview
Purpose
This chapter describes the preventive maintenance activity applicable to the 9311 Macro
V1 OD cabinet.

Contents

Preventive maintenance activity 3-2

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 3-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance activity Preventive maintenance activity

....................................................................................................................................................................................................................................

Preventive maintenance activity


Preventive maintenance
The preventive maintenance is used to periodically test the items of equipment that do not
directly trigger any alarm at the OMC. However, the execution of preventive maintenance
procedures can trigger alarms at the OMC.
These procedures must be performed according to the following schedules.
It is possible to group some of the procedures, which reduces the intervention time. The
intervention time indicated corresponds to the intervention time for each item of
equipment.
Note: In certain environments, these procedures may be required more frequently:
• In dusty or dirty environments the fan filter may need to be replaced more
frequently.
• Environmental conditions and door opening-closing frequency may impact the
door gasket ageing.
• Antenna mounts and connectors may require periodic cleaning in dirty and high
humidity areas.
• Systems located in high seismic areas may require anchor bolts and mounting
hardware to be tightened periodically especially for field installed items.

Preventive maintenance schedule for the 9311 Macro V1 OD equipment

Procedure Periodicity Test Tools Recommended Replacement


duration required replacement sheet
(approx.) Schedule
“Checking the Every site Two minutes None N/A
door alarm” visit
(p. 7-2)
“Inspecting the Every two One hour • Flat N/A
Connectors” years screw-
(p. 9-2) drivers
• 7/16
torque
wrench
“Replacing the Every four 20 minutes Screwdriver Every four years
PRELIMINARY

batteries of the years


9311 Macro V1
OD”
(p. 10-109)

....................................................................................................................................................................................................................................
3-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Preventive maintenance activity Preventive maintenance activity

PRELIMINARY
....................................................................................................................................................................................................................................

Procedure Periodicity Test Tools Recommended Replacement


duration required replacement sheet
(approx.) Schedule
“Inspecting the Once a year 30 minutes Wrench N/A
AC inlet cable
gland” (p. 9-8)
“Inspecting the Every site 15 minutes None If verification See NN- 20500-011
EMC door visit or at least failed (after eight
gasket” (p. 9-9) once a year years, a particular
attention is
recommended)

Preliminary checks before performing preventive maintenance procedures


For outdoor Node Bs, in windy conditions, be careful when opening and closing cabinet
doors to prevent damage to equipment or harm to people. Hold doors firmly until you
properly secure the door latch mechanism. It is not recommended to do maintenance
when the wind is over 70 km/h.

WARNING
Personal injury hazard
The personnel working on the cabinet must be authorized to work according to the
applicable safety standards

NOTICE
Equipment damage hazard
For outdoor equipment, make sure that there is no water trapped on the top of the door
gasket prior to opening doors. If water is present, wipe or sponge off water to avoid water
from entering the equipment.

NOTICE
Equipment damage hazard
Missing panels, covers or blank slot filler modules may lead to incorrect cooling and loss
of EMI integrity. Ensure all covers, panels and filler modules are fitted correctly
PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 3-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance activity Preventive maintenance activity

....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.

Description of a preventive maintenance procedure


A preventive maintenance procedure is divided into the following parts:
• The title
• The main body with the following information:
– Intervention time
– Tools required
– Step-by-step actions
– One or more figures
PRELIMINARY

....................................................................................................................................................................................................................................
3-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
4 4 orrective maintenance
C
activity

Overview
Purpose
This chapter describes the corrective maintenance activity applicable to the 9311 Macro
V1 OD cabinet.

Contents

Corrective maintenance activity 4-2

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 4-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance activity Corrective maintenance activity

....................................................................................................................................................................................................................................

Corrective maintenance activity


Corrective maintenance
The network maintenance is based on the supervision of the network, by using the OAM
graphical interface. For more information, refer to Alcatel-Lucent 9353 Wireless
Management System - User Guide, 9YZ-04088-0014-PCZZA.
It is also based on the identification and replacement of faulty items of equipment, using
the alarms.
The process is divided into the following two steps:
• Locating and identifying the faulty items of equipment, by using the information
provided in Alcatel-Lucent 9353 Wireless Management System - Node B Alarms
Reference Guide for 9100, 9926, 9941, 9944 and 93xx Node B, 9YZ-04088-0060-
UFZZA
• Replacing the faulty items of equipment, by using the replacement procedures given
in this document

Replacing the digital shelf equipment

Procedure Order Code Impact on service


“Replacing a CEM” 3JR20059DA (eCEM-U) Loss of capacity or service
(p. 10-4) 300986049 (xCEM-U) interruption (depending on the
number of CEMs in the digital
shelf)
“Replacing a CCM” 3JR20073BB (eCCM-U-GE) Service interruption
(p. 10-10) 3JR20038AD (xCCM-U-GE)
PRELIMINARY

....................................................................................................................................................................................................................................
4-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance activity Corrective maintenance activity

PRELIMINARY
....................................................................................................................................................................................................................................

Procedure Order Code Impact on service


“Replacing an optical Single-Mode (SM) Single Service interruption on the radio
transceiver” (p. 10-19) fiber SFP to radio device: device associated with the optical
300976305 transceiver being replaced

1AB194670018
Single-Mode (SM) Dual fiber
SFP to radio device:
301030433
1AB187280065
Multi-Mode (MM) SFP to
radio device:
300976297
1AB187280063
Single-Mode (SM) SFP on GE Loss of capacity or service
MDA: interruption on the Iub interface
3HE00028CA (RoHS 6/6) up
to 10Km
3HE00867CA (RoHS 6/6) up
to 40Km
3HE00029CA (RoHS 6/6) up
to 80Km
Multi-Mode (MM) SFP on GE
MDA: 3HE00027CA (RoHS
6/6)
“Replacing the fan rack 3JR37517AE Service interruption
module” (p. 10-24)
“Replacing the pre-cabled 3JR08221AA Service interruption
rack” (p. 10-31)

Replacing the RF block equipment

Procedure Order code RoHS compliant Node B variant Impact on


order code service
PRELIMINARY

“9311 Macro V1 TRDU60-21: 9311 Macro V1 OD Telecom outage.


OD with d4U: 3JR21012AB Radiation hazard
Replacing a TRDU60-21B:
TRDU” (p. 10-47) 3JR09305AA

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 4-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance activity Corrective maintenance activity

....................................................................................................................................................................................................................................
Replacing the power system equipment

Procedure Product RoHS compliant Node B variant Impact on


reference (PEC product service
code) reference (PEC
code)

“Replacing the dc power NTUM87AA NA 9311 Macro V1 BTS power down


system shelf” (p. 10-72) OD
“Replacing the filtering Single phase NA 9311 Macro V1
box” (p. 10-75) filtering box: OD
NTUM90AA
Split-phase
filtering box
(US):
NTUM90BA
Split-phase
filtering box:
NTUM90CA
Triphase filtering
box:
NTUM90DA
“Replacing a lightning NTUM91EA NA 9311 Macro V1
protector of the ac filter OD
box” (p. 10-82)
“Replacing the iDACS ac NTUM82AA NA 9311 Macro V1
breaker” (p. 10-87) OD
“Replacing the Single SPCM: SPCM: 9311 Macro V1
Power Control Module NTUM85AA NTUM85AF OD
(SPCM)” (p. 10-94)
“Replacing a rectifier” NTUM86AA NTUM86AF 9311 Macro V1
(p. 10-97) OD
“Replacing the rectifier ac NTUM88AA NA 9311 Macro V1
breaker” (p. 10-100) OD
“Replacing the batteries of NTUM92AA NTUM92AF 9311 Macro V1
PRELIMINARY

the 9311 Macro V1 OD” OD


(p. 10-109)

....................................................................................................................................................................................................................................
4-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance activity Corrective maintenance activity

PRELIMINARY
....................................................................................................................................................................................................................................
Replacing optional equipment

Procedure Product RoHS compliant Node B variant Impact on


reference (PEC product service
code) reference (PEC
code)
“Replacing the NTUM7200 NA 9311 Macro V1
Manufacturing OD
Commissioning and
Alarm (MCA) module
of the 9311 Macro V1
OD” (p. 10-114)
“Replacing the alarm NTUM89BA NA 9311 Macro V1
protection module” (A0844383) OD
(p. 10-118)
“Replacing the Pulse NTUM89CA NA 9311 Macro V1 BTS power down
Code Modulation OD
(PCM) protection
module of the 9311
Macro V1 OD”
(p. 10-121)
“9311 Macro V1 OD NTUM32BA - 9311 Macro V1
with d4U: Replacing OD
the double TMA
module” (p. 10-123)
“9311 Macro V1 OD NTUM32CB NTUM32CG 9311 Macro V1
with d4U: Replacing OD
the light TMA/AISG AISG TMA: NA AISG TMA:
TMA module” NTUM32CM
(p. 10-128)
“Replacing the NTUM60AA NTU720HM 9311 Macro V1
Interconnection OD
Module of the 9311
Macro V1 OD with
d4U Node B”
(p. 10-134)
“Replacing the NTUM99XA - 9311 Macro V1
anti-sliding strips of OD
PRELIMINARY

9311 Macro V1 OD
cable cover”
(p. 10-137)

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 4-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance activity Corrective maintenance activity

....................................................................................................................................................................................................................................

Procedure Product RoHS compliant Node B variant Impact on


reference (PEC product service
code) reference (PEC
code)
“Replacing the DC 1AF17608ABAA Service
Surge Protection Box, interruption
if used” (p. 10-142)

Description of a replacement procedure


A replacement procedure is divided into the following parts:
• The title
• The main body with the following information:
– The intervention time
– The required tools
– The impact of the procedure, if necessary
– The step-by-step actions of the procedure
One or more figures are provided to help you execute the actions. They show the Field
Replaceable Unit (FRU) schematically and its location in the cabinet.

Intervention restrictions
There may be a lapse of time between the identification of the alarm at the Access OAM
Graphic User Interface (GUI) and the time you arrive at the site.
You must be synchronized with the access network controller or system administrator (by
telephone) before an on-site intervention, in the following cases:
• Isolating procedures
• Completion of an on-site intervention
• Return to service procedure

General personnel safety instructions


The personnel must obey the safety instructions specific to the installation site:
• Rules concerning the premises (see instructions posted on site or in the building)
• Rules linked to general personnel safety instructions
PRELIMINARY

The personnel working on the cabinet must be authorized to work according to security
standards.

....................................................................................................................................................................................................................................
4-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance activity Corrective maintenance activity

PRELIMINARY
....................................................................................................................................................................................................................................
Equipment safety instructions
This solution normally operates when the external temperature is between – 40 °C and
+ 50 °C.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 4-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance activity Corrective maintenance activity

....................................................................................................................................................................................................................................
PRELIMINARY

....................................................................................................................................................................................................................................
4-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
5 5 acro V1 Node B Outdoor
M
with 9926 d4U:
Introduction

Overview
Purpose
This chapter gives an overview of the 9311 Macro V1 OD, configured with a 9926 d4U
Node B in the digital shelf.

Contents

9311 Macro V1 OD introduction 5-2

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 5-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Macro V1 Node B Outdoor with 9926 d4U: Introduction 9311 Macro V1 OD introduction

....................................................................................................................................................................................................................................

9311 Macro V1 OD introduction


Introduction
The 9311 Macro V1 OD is an ETSI UMTS Node B element and supports the Iub
interface.
The 9311 Macro V1 OD only supports the Frequency Division Duplex (FDD) mode.
The 9311 Macro V1 OD is responsible for radio transmission/reception from/to one or
more cells to/from the User Equipment (UE).
The 9311 Macro V1 OD provides:
• The means of communication between a UE and a network using Transport Channels
• Physical layer channels which are necessary to synchronize the downlink and also to
perform cell selection/re-selection and hand-over preparation
• Measurement information to the RNC for radio resource management (hand-over,
power control)
The 9311 Macro V1 OD provides up to eight E1/T1 with Inversion Multiplexing ATM
(IMA) or Drop and Insert capability (fractional E1/T1). It also supports multi-PCM
without IMA.
The 9311 Macro V1 OD support the Hybrid Iub and full IP Iub using the x/eCCM-U +
GE MDA.

9311 Macro V1 OD interfaces


The 9311 Macro V1 OD provides the following interfaces.
• Uu interface (UMTS User interface): this interface is used between the Node B and
the UE. It is dependent on the technology used on the radio (for example, it can be
W-CDMA or TD/CDMA).
• Iub interface (Interface Node B): this interface lies between the RNC and the Node B.
It allows to connect RNCs.

9311 Macro V1 OD cabinets


The 9311 Macro V1 OD cabinet is a single cabinet closed by two doors. It is designed to
ease transport, installation, repair, network growth and flexibility, and to manage diverse
traffic demands.
To increase the Node B capacity, modules are added instead of whole cabinets.
PRELIMINARY

The 9311 Macro V1 OD with d4U can operate only in the 2100 MHz bandwidth with its
internal modules. Other frequencies, i.e. 900 MHz or 850 MHz, can be supported using
remote radio modules (Remote Radio Heads, or RRH)
The following figure shows an outside view of the 9311 Macro V1 OD.
....................................................................................................................................................................................................................................
5-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Macro V1 Node B Outdoor with 9926 d4U: Introduction 9311 Macro V1 OD introduction

PRELIMINARY
....................................................................................................................................................................................................................................

Figure 5-1 9311 Macro V1 OD outside view

9311 Macro V1 OD modules


The latest generation of modules proposed in 9311 Macro V1 OD, after cabinet
renovation with a d4U Node B in the digital rack, is based on following modules:
• xCCM-U or eCCM-U module for controller
• xCEM-U or eCEM-U module for modem
• TRDU
The TRDU module operates in the 2100 MHz bandwidth. PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 5-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Macro V1 Node B Outdoor with 9926 d4U: Introduction 9311 Macro V1 OD introduction

....................................................................................................................................................................................................................................
PRELIMINARY

....................................................................................................................................................................................................................................
5-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
6 6311 Macro V1 OD
9
hardware presentation

Overview
Purpose
This chapter describes the hardware presentation of the Macro V1 Node B Outdoor with
9926 d4U.

Contents

Hardware presentation for 9311 Macro V1 OD with d4U digital shelf 6-2
configuration
d4U Node B in a Dual Node B Configuration 6-4

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 6-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD hardware presentation Hardware presentation for 9311 Macro V1 OD with d4U
digital shelf configuration
....................................................................................................................................................................................................................................

Hardware presentation for 9311 Macro V1 OD with d4U digital


shelf configuration
Introduction
This part is a hardware presentation of the 9311 Macro V1 OD cabinet types.
The 9311 Macro V1 OD products provided by Alcatel-Lucent are the following:
• 9311 Macro V1 OD 2100 (UMTS 2100)

9311 Macro V1 OD 2100 hardware presentation


The 9311 Macro V1 OD cabinet is divided into the following compartments:
• Upper compartment
• Main compartment
• Bulkhead
The upper compartment comprises the iDACS (inter Direct Ambient Cooling System).
The iDACS is an integral part of the BTS cabinet design. It is the cooling unit of the
cabinet and is accessed through the front-hinged access door.
The main compartment is divided into the two following parts.
The left part includes the following elements:
• one MCA module
• one AC power system shelf which contains DC distribution module, the SPCM
(Single Power Control Module) and up to seven rectifiers
• one digital shelf configured with the 9926 d4U
• one external alarm protection module
• one PCM protection module (LPPCM)
• one battery
• a DC breaker panel
The right part includes the following elements:
• one TRDU shelf, containing up to six TRDU modules
• one AC distribution module
• one power and alarm interconnection module for user equipment (also called User
ICO)
PRELIMINARY

• one user rack 3 HU wide, of which one HU is used for the RETA system CCU
• one AC filtering box
The bulkhead allows cable connection and lightning protection.

....................................................................................................................................................................................................................................
6-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD hardware presentation Hardware presentation for 9311 Macro V1 OD with d4U

PRELIMINARY
digital shelf configuration
....................................................................................................................................................................................................................................

Figure 6-1 9311 Macro V1 OD Inside view

Figure 6-2 9311 Macro V1 OD Cabinet layout

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 6-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration

....................................................................................................................................................................................................................................

d4U Node B in a Dual Node B Configuration


Pre-requisite
• An existing d4U Node B configuration.

Restrictions / Limitations / Operational Constraints


• d4U Node B is possible in a horizontal configuration only
• d4U Node B power supply by additional/customer source

Figure 6-3 9926 d4U in Dual Controller Hardware Configuration

Dual Node B Specifications


A new feature will enable operators to stack two logical Node Bs inside the same d4U in
order to provide a higher signaling capacity.
In this configuration - also called “dual controller configuration” - two controllers (one
per Node B) are plugged into the 9926 d4U and all modems will be shared between the
controllers. The hosting of these two Node Bs implies that the both Node Bs are equipped
with GigE MDA eCCM-U controllers and eCEM-U or xCEM-U modems.
Note: Neither the xCCM-U controller nor the 4E1 MDA configuration are supported
with the dual Node B feature.
Both controllers will be hosting their own Iub backhaul termination as well as their own
PRELIMINARY

CPRI interfaces towards the remote equipments (TRDU or RRH).


The Node Bs are independent except for some interfacing mechanisms for OAM
purposes.

....................................................................................................................................................................................................................................
6-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration

PRELIMINARY
....................................................................................................................................................................................................................................
In the dual Node B configuration, an inter-CCM interface allows the two eCCM-U
controllers to communicate across the backplane and check the configuration information
consistency.

Supported Configurations
When the d4U is used in a Dual Node B (2 controller) set-up, the following hardware
configurations are possible:
• eCCMu with GE MDA is supported in Physical slot 5 and 4 for dual controller (Split
Mode).
Note: eCCMu supports up to a maximum of 6 modems in a single controller
configuration.
• xCCMu is not supported in a dual Node B configuration.
Note: xCCMu is supported in a single controller Node B configuration.
• eCCM in Phy slot 5 can support upto 6 CEMs ( 1,2,3,6,7,8).
• eCCM in Phy slot 4 can support upto 3 CEMs ( 1,2,3).
• xCEM and eCEM are supported.
• Hybrid/NativeIP Backhaul is supported. (In a Dual Node B configuration, both Node
Bs need not be using same backhaul )
• Ethernet Backplane (Ethernet-Ethernet), ATM Backplane (ATM-ATM) is supported.

Upgrade procedure from Single Technology to Dual Node B supported load

Pre-requisites
The pre-requisites are as follows:
• Single controller in p-slot 5 (CCMA) can support up to a maximum of 6 modems
• In this set up, BTS_Mode is Single Technology

Upgrade procedure
Step Action Observation
1 Upgrade the software controller to
DualNodeB supported load and
Reboot.
PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 6-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration

....................................................................................................................................................................................................................................

Setup after upgrade


The setup after the upgrade is as follows:
• Single controller in p-slot 5 (CCMA) can support up to six modems
• In this set up, BTS_Mode is Single Technology.

Note: CCM-B is supported in d4Uv3 .

Modem with DualNodeB feature


The modems with DualNodeB feature can work with CCM-B. For this, the modems
should be upgraded with CCMA, before working with CCM-B

Downgrade procedure from DualNode B supported load to DualNode B unsupported load in d4Uv3
to Single Technology

Pre-requisites
The pre-requisites are as follows:
• Two Controllers with DualNode B can support up to a maximum of 6 modems.
• In this set up, the BTS_Mode is Dual_Node B.

Downgrade procedure
Step Action Observation
1 Plug out the CCM-B..
2 Use the daisy chain configuration for
the alarm cable.
3 Connect eAM to FanTray-2.
4 Connect SiteLAN to CCM-A.
5 Connect to CCM-A TIL, and modify
BTS_Mode from DualNodeB to Single
Technology.
6 Downgrade the controller and reboot.
PRELIMINARY

....................................................................................................................................................................................................................................
6-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration

PRELIMINARY
....................................................................................................................................................................................................................................

Setup after downgrade


The setup after the downgrade is as follows:
• Single controller with dual NodeB supported load in p-slot 5 can support up to a maximum
of 6 modems
• In this set up, BTS_Mode is Single Technology

Migration from Single Technology configuration to BTS mode, with DualNodeB supported load

Pre-requisites
The prerequisites are as follows:
• Single controller in p-slot 5 (CCMA) can support up to a maximum of 6 modems
• The alarm cable is daisy chained
• Cabinet and external alarm kit is connected to Fan Tray 2
• SiteLAN connected to CCMA
• In both the fantrays, BTS_Mode is Single Technology

Migration procedure
Step Action Observation
1 Connect to TIL and update the
BTS_Mode to DualNodeB, NeID and
modem slot array in FanTray-1.
2 Plug out the controller.
3 Remove daisy chaining of the alarm
cable between fan tray.
4 Move cabinet and external alarm kit
from fan tray 2 to fan tray 1.
5 Connect SiteLAN to CCMA.
6 Insert second controller in CCMB with
Dual NodeB supported load.
7 Connect the alarm cable between
PRELIMINARY

CCMB and fantray-2.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 6-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration

....................................................................................................................................................................................................................................

Migration procedure
8 Connect to TIL of CCMB and update
BTS_Mode to DualNodeB, NeID and
modem slot array in FanTray-2 and
reboot.
9 Insert CCMA back. Now both the controllers are in
DualNodeB configuration.

Setup after the migration procedure


The setup after the migration procedure is as follows:
• CCMA can support upto 3 modems in the right and CCMB can support 3 modems in the
left. (The behavior of both the controllers depend on the modifications done on the
ModemSlotArray)
• CCMA and CCMB are connected to alarm cable in fan tray 1 and fan tray 2, respectively
• Cabinet and external alarm kit is connected to CCM_A
• After the migration, the BTS_Mode is Split Technology in both I
• In both I, the configuration of the ModemSlotArray is as follows:
ModemSlotArray = 02 02 02 00 00 01 01 01.
Note: The ModemSlotArray can be modified as well.

Upgrade procedure from Single Technology configuration with DualNodeB unsupported load to
DualNodeB with DualNodeB supported load

Pre-requisites
The prerequisites are as follows:
• Single controller with DualNodeB unsupported load in p-slot 5 (CCMA) can support up to a
maximum of 6 modems
• The alarm cable is daisy chained
• Cabinet and external alarm kit is connected to Fan Tray 2
• Before the upgrade procedure, BTS_Mode is Single Technology
PRELIMINARY

....................................................................................................................................................................................................................................
6-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration

PRELIMINARY
....................................................................................................................................................................................................................................

Upgrade procedure
Step Action Observation
1 Upgrade the software controller to
DualNode B supported load and
reboot.
2 Connect to TIL of CCM_A and update
BTS_Mode to DualNodeB, NeID and
modem slot array in FanTray-1.
3 Plug out the controller.
4 Remove daisy chaining of the alarm
cable between fan trays.
5 Move cabinet and external alarm kit
from fan tray 2 to fan tray 1.
6 Insert the second controller in CCMB
with DualNodeB unsupported load.
7 Connect the alarm cable between
CCMB and fantray-2.
8 Upgrade to DualNode B supported
load and reboot.
9 Connect to TIL of CCMB and update
BTS_Mode to DualNodeB, NeID and
modem slot array in FanTray-2 and
reboot.
10 Insert CCMA back. Now both the controllers are in
DualNodeB configuration.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 6-9
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration

....................................................................................................................................................................................................................................

Setup after the upgrade procedure


The setup after the upgrade procedure is as follows:
• CCMA can support upto 3 modems in the right and CCMB can support 3 modems in the
left. (The behavior of both the controllers depend on the modifications done on the
ModemSlotArray)
• CCMA and CCMB are connected to alarm cable in fan tray 1 and fan tray 2, respectively
• Cabinet and external alarm kit is connected to CCM_A
• After the migration, the BTS_Mode is Split Technology in both I
• In both I&C, the configuration of the ModemSlotArray is as follows:
ModemSlotArray = 02 02 02 00 00 01 01 01
Note: The ModemSlotArray can be modified as well.

Detects another controller in Simplex or Duplex when BTS_Mode is SingleTechnology with


DualNodeB Supported load
Note: This is a configuration error scenario and might lead to Bus Conflict on the
backplane.
There are two scenarios where this type of configuration error might occur:
Scenario 1: Both the Controllers are present during power up. Both the controllers find
another mate controller. The CCM-OAM does MIB KO and disables all
GigE/HSSL/1-wire links to all the modem slots and raises an alarm.
Scenario 2: New Controller is plugged in D4U with the already existing running
Controller. Disable all GigE/HSSL/1-wire links to all the modem slots for the already
running controller.

Two controllers with different BTS Mode values


Note: This is a configuration error scenario and might lead to Bus Conflict on the
backplane.
Example: In this case, one controller with BTS_Mode is in Single Technology mode and
the other controller with BTS_Mode is in Split Technology mode. The two different
scenarios are described below:
Controller with BTS_Mode in Single Technology: Two scenarios might occur. The
scenarios are described in the “Detects another controller in Simplex or Duplex when
PRELIMINARY

BTS_Mode is SingleTechnology with DualNodeB Supported load” (p. 6-10).


Controller with BTS_Mode in Split Technology:If the controller finds another
controller which is present or inserted but it is unable to communicate, the controller
raises alarm cannot communicate with Partner NodeB.
....................................................................................................................................................................................................................................
6-10 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration

PRELIMINARY
....................................................................................................................................................................................................................................
Two controllers with conflicting modem allocation in ModemSlotArray
Note: This is a configuration error scenario and might lead to Bus Conflict on the
backplane.
In such case, where both the controllers are in conflict with modem allocation in
ModemSlotArray, the controllers do the following:
• Both controllers raise an alarm Inconsistent Partner Board Configurationto OMCB
• Both controllers disconnect HSSL/GigE/1-wire connections to the problematic
inconsistent modem slot

NE ID received from IML does not match with NE ID read from I&C
When the controller detects that the NE ID received from IML does not match with the
NE ID read from I&C, it raises alarmInconsistent Partner NodeB Name.

d4Uv3 with one controller & upto 3 modems: Fantray


If the d4Uv3 is equipped with one controller and 3 modems, then all the modules must be
kept in one thermal zone.
The second fan tray must not be powered off for the following reasons:
• If the fan tray is powered off, fan alarms are raised as the tacho reads 0.
• The temperature margin improves if both the fan trays are powered ON.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 6-11
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD hardware presentation d4U Node B in a Dual Node B Configuration

....................................................................................................................................................................................................................................
PRELIMINARY

....................................................................................................................................................................................................................................
6-12 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
7 Checking the door alarm
7

Overview
Purpose
This part describes how to check the door alarm.

Contents

Checking the door alarm 7-2

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 7-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Checking the door alarm Checking the door alarm

....................................................................................................................................................................................................................................

Checking the door alarm


Purpose
The purpose of this procedure is to check the door intrusion alarm that is generated when
the Node B doors are opened.

Intervention time
Two minutes

Tools required
None
Important! This procedure requires to be in contact with the OMC administrator.
Important! For outdoor models, do not forget to ask the site manager for the Node B
key.

Procedure
...................................................................................................................................................................................................

1 Contact the OMC administrator to check that the door alarm is OFF.
...................................................................................................................................................................................................

2 Open the Node B door(s) to activate the door alarm.


...................................................................................................................................................................................................

3 An alarm must be observed at the OMC. Request confirmation from the OMC
administrator.
...................................................................................................................................................................................................

4 Close the Node B door(s).


...................................................................................................................................................................................................

5 Check with the OMC administrator that the door alarm is OFF.
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
7-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
8 8311 Macro V1 OD power
9
up and power down
procedures

Overview
Purpose
This chapter describes how to power up and power down the 9311 Macro V1 OD
cabinets, when configured with a 9926 d4U in the digital shelf.

Contents

Powering up a 9311 Macro V1 OD with d4U 8-2


Powering down a 9311 Macro V1 OD with d4U 8-10

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 8-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U

....................................................................................................................................................................................................................................

Powering up a 9311 Macro V1 OD with d4U


Purpose
The procedure below describes how to power up a Macro V1 Node B Outdoor with 9926
d4U, when it is completely powered off.

Tools required
• Key to open the door
• Lamp
• Multimeter
• Phillips screwdrivers
• Tie rap pliers

Initial Checks
The aim of this section is to check that the cabinet(s) (9311 Macro V1 OD and battery
cabinet if employed) is (are) properly set up and ready to be powered up.
The initial checks are the following:
1. Visually check that:
• The 9311 Macro V1 OD is correctly secured.

The battery cabinet (if employed) is correctly secured.

The 9311 Macro V1 OD and battery cabinet does not exhibit any sign of physical
damage.
Note: If physical damage is observed, notify the supervisor immediately.
• The circuit breaker(s) of the customer AC box (9311 Macro V1 OD and battery
cabinet if that exists) is (are) properly labeled and OFF.
2. Open the doors of the cabinet and look at the internal batteries and check if:
• The date mm/yy has not expired within a six month time frame.
Note: If the six month period after the deadline has elapsed, the batteries must be
returned to a warehouse for complete recharging.
• Each battery is properly connected, check the cables, straps, terminal blocks.
3.
On the 9311 Macro V1 OD, check that the following components are switched OFF:
• All breakers of the AC Main.
PRELIMINARY

The AC Main module houses the following breakers:


- CB01 Rectifiers 1-2
- CB02 DACS Heater 1
- CB03 Rectifier 3-4
- CB04 DACS Heater 2
....................................................................................................................................................................................................................................
8-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U

PRELIMINARY
....................................................................................................................................................................................................................................
- CB05 Rectifiers 5-6-7
- CB06 DACS Blower
- CB07 AC outlet differential breaker

Figure 8-1 AC main module: Front panel detail

• All the breakers of the main DC Breaker module.


The main DC Breaker module presents the following elements :
- Battery circuit breakers
- RF breaker (TRDUs)
- Digital breaker for the d4U Node B (digital shelf)
- User breaker (user)
- DACS breaker (iDACS)
• All the breakers of the additional DC Breaker module.
The DC Breaker module presents the following elements :
- RRH DC breaker
- d4U Node B lower DC breaker
PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 8-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U

....................................................................................................................................................................................................................................

Figure 8-2 DC Breaker Panel used with the d4U Node B configuration

• Each rectifier power switch.


• Each d4U Node B fan rack power switch.
• Each TRDU power switch.
PRELIMINARY

....................................................................................................................................................................................................................................
8-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U

PRELIMINARY
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................

1 At the customer AC box, switch ON the circuit breaker of the 9311 Macro V1 OD
cabinet.
...................................................................................................................................................................................................

2 Open the AC cover by removing the screws that secure the plate.
...................................................................................................................................................................................................

3 On AC terminal block, measure the voltage of 9311 Macro V1 OD by using a multimeter.


Check that the voltage measurement is within the specified range.
The following table gives the network type according to the terminal block.

Net- Termi- 1 2 3 4 5 6
work nal
type block
position
Single Measure L1 N GND N
Phase between
L1 and N
Split Measure L1 L2 GND N
Phase between
L1 and
L2 and
between
L2 and N
Triphase Measure L1 L2 GND
120/208 between
L1 and
L2, and
between
L2 and N
Triphase Measure L1 L2 L3 N GND
230/400 between
each
Phase
and
Neutral:
PRELIMINARY

L1 and
N, L2
and N,
L3 and N

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 8-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

4 Put the cover of the AC box back in place and secure it.
...................................................................................................................................................................................................

5 Switch ON all AC main breakers.


...................................................................................................................................................................................................

6 Listen to the fans starting up and check that the eight LEDs of the iDACS are lit up green.
...................................................................................................................................................................................................

7 One by one, switch ON each rectifier.

Figure 8-3 Front view of the DC power system shelf

Check that the green "ON" LED lit on each rectifiers shortly after.
...................................................................................................................................................................................................

8 Once each rectifier have been switched ON, check that the green "ON" LED lit on the
SPCM.
...................................................................................................................................................................................................

9 Switch ON the battery breaker located on the DC distribution in case a back-up battery is
PRELIMINARY

employed (internal).

....................................................................................................................................................................................................................................
8-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U

PRELIMINARY
....................................................................................................................................................................................................................................

Figure 8-4 DC Distribution Panel - Front view

...................................................................................................................................................................................................

10 Switch ON the User circuit breaker located on the DC distribution (see figure above).
...................................................................................................................................................................................................

11 Measure the voltage on the user port PWR by using a multimeter in V DC mode. Check
that the value is within the specified range.
...................................................................................................................................................................................................

12 Switch OFF the User on DC distribution (if not employed).


PRELIMINARY

...................................................................................................................................................................................................

13 Switch ON the DACS and the RF circuit breakers located on the DC distribution.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 8-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

14 One by one, switch ON each TRDU.


...................................................................................................................................................................................................

15 On the DC Breaker Panel, power up the Breaker 25A Fan Rack Lower and the Breaker
40A RRH, if used.

Figure 8-5 DC Breaker Panel used with the d4U Node B configuration
PRELIMINARY

The 9311 Macro V1 OD is now powered ON.

....................................................................................................................................................................................................................................
8-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9311 Macro V1 OD power up and power down procedures Powering up a 9311 Macro V1 OD with d4U

PRELIMINARY
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

16 Switch ON the circuit breaker of the digital shelf located on the DC distribution.
...................................................................................................................................................................................................

17 Switch ON the power switches for the upper and lower fan racks on the d4U Node B.
The 9311 Macro V1 OD is now powered ON.
...................................................................................................................................................................................................

18 Check that the 9311 Macro V1 OD is in an operational state after its BISTs by checking
the LEDs status.
...................................................................................................................................................................................................

19 Close the doors.


E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 8-9
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9311 Macro V1 OD power up and power down procedures Powering down a 9311 Macro V1 OD with d4U

....................................................................................................................................................................................................................................

Powering down a 9311 Macro V1 OD with d4U


Purpose
Perform the following procedure to power down a 9311 Macro V1 OD with d4U in the
digital shelf.

Procedure
...................................................................................................................................................................................................

1 Open the Node B doors.


...................................................................................................................................................................................................

2 Switch OFF the concerned breakers in the following order:


• All TRDUs
• The RRH breaker on the DC breaker panel (if RRHs are employed)
• All d4U Node B power switches
• The digital breaker + breaker for d2U lower
• The RF breaker
• The user breaker
• DACS
• The battery breaker
• All rectifiers
• AC main breaker
...................................................................................................................................................................................................

3 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
8-10 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
9 9reventive maintenance
P
procedures

Overview
Purpose
This chapter describes the preventive maintenance procedures of the Macro V1 Node B
Outdoor with 9926 d4U.
The preventive maintenance is used periodically for the items of equipment which do not
directly trigger any alarm at the WMS.

Contents

Inspecting the Connectors 9-2


Inspecting the anchor bolts 9-5
Inspecting the AC inlet cable gland 9-8
Inspecting the EMC door gasket 9-9

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 9-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance procedures Inspecting the Connectors

....................................................................................................................................................................................................................................

Inspecting the Connectors


Purpose
Carry out the following procedure to inspect the various connectors of a 9311 Macro V1
OD in a d4U Node Bconfiguration.

Intervention time
One hour

Tools required
• Flat screwdrivers
• 7/16 torque wrench

DANGER
Environment and personnel protection
Caution presence of voltage.

CAUTION
Tightening torques
The 7/16 tightening torque must be 25 N.m (24 N.m to 27 N.m).
PRELIMINARY

....................................................................................................................................................................................................................................
9-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Preventive maintenance procedures Inspecting the Connectors

PRELIMINARY
....................................................................................................................................................................................................................................

Figure 9-1 9311 Macro V1 OD with d4U: STSRx wiring

Procedure
...................................................................................................................................................................................................

1 Open the doors.


...................................................................................................................................................................................................

2 Check for corrosion or oxidation around connectors, nicks and abraded sheaths.
Note: This may be more prevalent in high heat and high humidity environments.
...................................................................................................................................................................................................

3 Inspect the MCA module connectors:


PRELIMINARY

• One Manufacturing connector from the MCA module and tighten it with screwdriver.
• One I/C1 connector from the MCA module and tighten it with screwdriver.
• One I/C2 connector from the MCA module and tighten it with screwdriver.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 9-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance procedures Inspecting the Connectors

....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

4 Inspect one CEATS connector from the SPCM and tighten it with screwdriver on the DC
power system shelf.
...................................................................................................................................................................................................

5 Inspect Digital shelf d4U Node B connectors:


• The CPRI connections on the x/eCCM-U.
• The IP connections with the RJ45 connector on the x/eCCM-U.
• The E1/T1 data connector from the xCCM-U/eCCM-U if present, and tighten with
screwdriver if necessary.
...................................................................................................................................................................................................

6 Inspect the RF antenna connectors from the TRDU TX/RX and bulkhead, if used:
• The two RF antenna connectors labeled RX and TX/RX and tighten them with the
7/16 torque wrench.
...................................................................................................................................................................................................

7 Inspect the Interconnection module connectors:


• The PA/PWR connectors from Interconnection module and tighten them with
screwdriver.
• Check on the TRDU, that the power connector is correctly plugged in.
...................................................................................................................................................................................................

8 Inspect the RF connectors from the bulkhead and tighten them with 7/16 torque wrench.
...................................................................................................................................................................................................

9 Replace or repair any damaged cables as necessary. Call the next level of support.
...................................................................................................................................................................................................

10 Inspect one plastic hood on all RF connectors without connections.


...................................................................................................................................................................................................

11 Close the doors.


E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
9-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Preventive maintenance procedures Inspecting the anchor bolts

PRELIMINARY
....................................................................................................................................................................................................................................

Inspecting the anchor bolts


Purpose
Perform the following procedure during each visit of maintenance.

Intervention time
20 minutes

Tools required
• Special TORX key inside the Node B
• 19-mm key
• 17-mm wrench

WARNING
Electric-shock hazard
The Node B remains supplied with the mains power supply.
There is a risk of sparks during the test.
Personnel safety rules: the personnel performing this check must wear rubber gloves and
must be isolated from the ground.

Procedure
...................................................................................................................................................................................................

1 Locate the anchor bolts.


The anchor bolts are located at the base of the cabinet.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 9-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance procedures Inspecting the anchor bolts

....................................................................................................................................................................................................................................

Figure 9-2 Location of anchor bolts

...................................................................................................................................................................................................

2 Displacement
The displacement of back and side access panels is necessary to access the anchor bolts.
Unscrew the inviolable screws with the special TORX key and remove the access panels.
...................................................................................................................................................................................................

3 Inspect anchor bolts at the base of the cabinet for tightness and/or damage:
• If anchor bolts are OK, go to step 5.
• If anchor bolts are damaged or not tight, go to next step.
...................................................................................................................................................................................................

4 Re-torque the anchor bolts where necessary.


PRELIMINARY

...................................................................................................................................................................................................

5 Replacement
Replace the access panels as they were before intervention.

....................................................................................................................................................................................................................................
9-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Preventive maintenance procedures Inspecting the anchor bolts

PRELIMINARY
....................................................................................................................................................................................................................................
Tighten the inviolable screws with the special TORX key.
E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 9-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance procedures Inspecting the AC inlet cable gland

....................................................................................................................................................................................................................................

Inspecting the AC inlet cable gland


Purpose
Carry out the following procedure to check AC inlet cable gland in the 9311 Macro V1
OD.

Intervention time
30 minutes

Tools required
Wrench

Procedure
...................................................................................................................................................................................................

1 Open the doors.


...................................................................................................................................................................................................

2 Inspect the cable gland body nut (inside cabinet) for tightness.
...................................................................................................................................................................................................

3 Tighten nut if necessary.


...................................................................................................................................................................................................

4 Check the rubber gasket of the cable gland for damage such as cracking.
...................................................................................................................................................................................................

5 Replace where necessary.


...................................................................................................................................................................................................

6 Close the doors.


E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
9-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Preventive maintenance procedures Inspecting the EMC door gasket

PRELIMINARY
....................................................................................................................................................................................................................................

Inspecting the EMC door gasket


Purpose
Carry out the following procedure to inspect and to replace the cabinet seals in the 9311
Macro V1 OD.

Intervention time
15 minutes

Tools required
None

Procedure
...................................................................................................................................................................................................

1 Open the doors.


...................................................................................................................................................................................................

2 Ensure good all-round seal containment.


...................................................................................................................................................................................................

3 Check seals for damages such as tearing or cracking.


...................................................................................................................................................................................................

4 If the seals are damaged, call the next level of support.


Note: Cabinet seals for the 9311 Macro V1 OD system are required for environmental
issues such as water ingress and condensation. The seals provide EMC and IP
protection and assist with overall noise reduction.
...................................................................................................................................................................................................

5 Close the doors.


E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 9-9
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Preventive maintenance procedures Inspecting the EMC door gasket

....................................................................................................................................................................................................................................
PRELIMINARY

....................................................................................................................................................................................................................................
9-10 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
10 10
Corrective maintenance
procedures

Overview
Purpose
This chapter contains the replacement procedures applicable to the Macro V1 Node B
Outdoor with 9926 d4U.

Contents

Replacing the 9926 d4U digital shelf equipment 10-3


Replacing a CEM 10-4
Replacing a CCM 10-10
Replacing an optical transceiver 10-19
Replacing the fan rack module 10-24
Replacing the pre-cabled rack 10-31
Replacing the RF block equipment 10-46
9311 Macro V1 OD with d4U: Replacing a TRDU 10-47
Replacing the cooling system equipment 10-54
Replacing the Direct Ambient Cooling System (DACS) of the 9311 Macro V1 10-55
OD
Replacing the iDACS blowers of the 9311 Macro V1 OD 10-59
Replacing the iDACS control board of the 9311 Macro V1 OD 10-61
Replacing the iDACS heaters of the 9311 Macro V1 OD 10-66
Replacing the iDACS air filter of the 9311 Macro V1 OD 10-68
PRELIMINARY

Replacing the power system equipment 10-71


Replacing the dc power system shelf 10-72
Replacing the filtering box 10-75

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Overview

....................................................................................................................................................................................................................................

Replacing a lightning protector of the ac filter box 10-82


Replacing the iDACS ac breaker 10-87
Replacing the Single Power Control Module (SPCM) 10-94
Replacing a rectifier 10-97
Replacing the rectifier ac breaker 10-100
Replacing the DC Breaker Panel 10-105
Replacing the batteries of the 9311 Macro V1 OD 10-109
Replacing the optional equipment 10-113
Replacing the Manufacturing Commissioning and Alarm (MCA) module of the 10-114
9311 Macro V1 OD
Replacing the alarm protection module 10-118
Replacing the Pulse Code Modulation (PCM) protection module of the 9311 10-121
Macro V1 OD
9311 Macro V1 OD with d4U: Replacing the double TMA module 10-123
9311 Macro V1 OD with d4U: Replacing the light TMA/AISG TMA module 10-128
Replacing the Interconnection Module of the 9311 Macro V1 OD with d4U 10-134
Node B
Replacing the anti-sliding strips of 9311 Macro V1 OD cable cover 10-137
Replacing the DC Surge Protection Box, if used 10-142
PRELIMINARY

....................................................................................................................................................................................................................................
10-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Overview

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

Replacing the 9926 d4U digital shelf equipment

Overview
Purpose
This section presents the replacement procedures applicable to 9926 d4U elements in the
digital shelf.

Contents

Replacing a CEM 10-4


Replacing a CCM 10-10
Replacing an optical transceiver 10-19
Replacing the fan rack module 10-24
Replacing the pre-cabled rack 10-31

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CEM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

Replacing a CEM
Carry out the following procedure to replace a eCEM-U or xCEM-U.

Intervention time
10 minutes

Tools required
Screwdriver
Extraction tool

Figure 10-1 xCEM-U front panel


PRELIMINARY

....................................................................................................................................................................................................................................
10-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CEM

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Figure 10-2 eCEM-U front panel

NOTICE
ESD hazard
Wear the antistatic bracelet when performing the maintenance procedure described
below.

NOTICE
Service-disruption hazard
This procedure causes a loss of capacity or a loss of service (depending on the number of
CEMs housed in the digital shelf of the 9926 d4U Node B).

NOTICE
Service-disruption hazard
When inserting a new eCEM-U module next to an existing xCEM-U module, this last one
reboots. When the xCEM-U module reboots, the assigned sector or frequency loses its
traffic.
To avoid this traffic loss, the cell or sector associated with the xCEM-U must be locked.
PRELIMINARY

Procedure
...................................................................................................................................................................................................

1 Open the Node B door(s), if any.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CEM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

2 Locate the faulty CEM in the 9926 d4U Node B:


• For a xCEM-U:
– Red LED is ON.

• For an eCEM-U:
– First LED (from top) is red.
– Second LED (from top) is OFF.

...................................................................................................................................................................................................

3 Lock the faulty cem object at the WMS by Set Administrative State.
Attention: If there is an xCEM-U module adjacent to the eCEM-U module to install,
lock also the xCEM-U module associated object in the WMS.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................

4 Undo and remove the lower or upper hook (if present and if the defective CEM is in slot 1
or slot 8).
PRELIMINARY

....................................................................................................................................................................................................................................
10-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CEM

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

5 Loosen the two screws on the CEM front panel.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CEM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

Figure 10-3 Extracting a CEM

...................................................................................................................................................................................................

6 Using the extraction tool, pull the defective CEM out of the shelf, see Figure 10-3,
“Extracting a CEM” (p. 10-8).
...................................................................................................................................................................................................

7 Check the release of the new CEM.


...................................................................................................................................................................................................

8 Insert the new CEM into the digital shelf of the 9926 d4U Node B, in the same slot as the
defective CEM.
...................................................................................................................................................................................................

9 Tighten the two screws on the CEM front panel.


PRELIMINARY

...................................................................................................................................................................................................

10 Put the hook back in place and secure it.

....................................................................................................................................................................................................................................
10-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CEM

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

11 From the WMS, unlock the cem object previously locked on the Step 3.
Attention: In the case where the eCEM-U module to install is adjacent to an xCEM-U
module, don't forget to also unlock the xCEM-U module associated object in the
WMS.
...................................................................................................................................................................................................

12 Check the state of the LEDs. They should go on, then take the following state:
• On a xCEM-U:
– Red LED is OFF.
– Green LED is ON.

• On an eCEM-U:
– First LED (from top) is OFF.
– Second LED (from top) is green.

E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-9
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CCM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

Replacing a CCM
Purpose
Carry out the following procedure to replace a eCCM-U or xCCM-U.

Intervention time
20 minutes

Tools required
• A screwdriver
• An extraction tool

Figure 10-4 xCCM-U-GE configuration front panel

Figure 10-5 eCCM-U-GE configuration front panel


PRELIMINARY

....................................................................................................................................................................................................................................
10-10 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CCM

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser radiation can cause
considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the
optical source is switched on. Always observe the laser warning instructions.

NOTICE
ESD hazard
Wear the antistatic bracelet when performing the maintenance procedure described
below.
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Important! There will be a loss of service on the Remote Radio device(s) and on the
dropped BTS in case of BTS daisy chaining through the NodeB .
Attention: If the replacement operation takes place in the context of the 9926 d4U
Node B upgrade with a CCM-U module from spare or from the factory containing a
UA7.1 software load, it is mandatory to remove all the CEM-U modules before
performing the software upgrade or the new UA08.1 software load will not start
correctly. This document considers only the Node B upgrade with the TIL.

Procedure
...................................................................................................................................................................................................

1 Open the Node B door(s), if any.


...................................................................................................................................................................................................
PRELIMINARY

2 Lock all the objects associated with the Remote Radio devices and the dropped BTS
connected to the faulty CCM at the WMS by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-11
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CCM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Attention: In case of the UA7.1 to UA08.1 software upgrade, don't forget to lock also
all the cem objects as it is mandatory to remove all the CEM-U modules before
performing the software upgrade.
...................................................................................................................................................................................................

3 Power down the 9926 d4U Node B.


To do this, follow the procedure “Powering down the 9926 d4U Node B”
(p. A-3) according to the 9926 d4U Node B hardware configuration used:
• In mono-controller configuration, cut off the power supply of the both RUCs.
• In dual controller configuration, cut off only the power supply of the RUC linked to
the defective CCM.
Attention: In case of the UA7.1 to UA08.1 software upgrade, cut off the power
supply of the both RUCs.
...................................................................................................................................................................................................

4 Loosen the two screws on the front panel of the CCM module to remove.

Figure 10-6 Extracting a CCM


PRELIMINARY

....................................................................................................................................................................................................................................
10-12 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CCM

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

5 Using the extraction tool, unplug the CCM from its RBP connectors, see Figure 10-6,
“Extracting a CCM” (p. 10-12).
Attention: In case of the UA7.1 to UA08.1 software upgrade, unplug also all the
existing CEM modules, see Figure 10-3, “Extracting a CEM” (p. 10-8).
...................................................................................................................................................................................................

6 Unplug the GPS cable (connector labeled “GPS”) from the CCM front panel if used.
...................................................................................................................................................................................................

7 Unplug the optical fiber(s) and remove the SFP transceiver(s) (connector(s) labeled
“OPTIC”) from the CCM front panel.
Note: The SFP transceiver(s) will be re-plugged in the new xCCM-U-GE or
eCCM-U-GE.
...................................................................................................................................................................................................

8 Unplug the digital cable (connector labeled "ALARM") from the CCM front panel.
...................................................................................................................................................................................................

9 Unplug the TIL cable (labeled “PORT 1”) from the CCM front panel.
...................................................................................................................................................................................................

10 On the xCCM-U-GE or eCCM-U-GE:


• Unplug the E1/T1 cable (connector labeled “PCM E1/T1”) if used or remove the
PCM connector cover from the CCM front panel .
• Unplug the Gigabit Ethernet cable(s) (connector labeled “MDA”) from the CCM front
panel.
• Remove the SFP transceiver(s) and / or the SFP cage cover(s) (connector labeled
“MDA”) from the CCM front panel.
Note: The SFP transceiver(s) and / or the SFP cage cover(s) and / or the PCM
connector cover will be re-plugged in the new xCCM-U-GE or eCCM-U-GE.
...................................................................................................................................................................................................

11 Pull the CCM out of the shelf, see Figure 10-6, “Extracting a CCM” (p. 10-12).
...................................................................................................................................................................................................

12
If the removed CCM is... Then...
PRELIMINARY

an xCCM-U Proceed with the Step 13 of this procedure


an eCCM-U Proceed with the Step 1 of the procedure
“Configure the new eCCM-U”

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-13
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CCM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Procedure “Configure the new eCCM-U”:
1. Locate the DIP switch on the module as indicated in the
Figure 10-7, “Location of the DIP switch on the eCCM-U”
(p. 10-14).
2. Set the DIP switch on the module to the “UMTS” position
(see Figure 10-8, “DIP switch settings on the eCCM-U”
(p. 10-15)).
Note: If necessary, set the DIP switch to the right position
with help of a screwdriver.

Figure 10-7 Location of the DIP switch on the eCCM-U


PRELIMINARY

....................................................................................................................................................................................................................................
10-14 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CCM

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Figure 10-8 DIP switch settings on the eCCM-U

...................................................................................................................................................................................................

13 Insert the new CCM module(s) into the slot guides without plugging it on the RBP.
...................................................................................................................................................................................................

14 Reconnect the GPS cable (connector labeled “GPS”) on the CCM front panel if used.
...................................................................................................................................................................................................

15 Reinsert the SFP transceiver(s) (connector(s) labeled “OPTIC”) in the CCM front panel.
...................................................................................................................................................................................................

16 Reconnect the optical fiber(s) (connector(s) labeled “OPTIC”) on the CCM front panel.
Important! In case of an CCM module equipped with Multi-Mode (MM) or
Single-Mode (SM) Dual fiber SFP transceivers, put the LC connectors (L/R) in the
same sense as they were before the intervention when reconnecting the optical fibers
on the CCM front panel,.
...................................................................................................................................................................................................

17 Reconnect the digital cable (connector labeled "ALARM") on the CCM front panel.
...................................................................................................................................................................................................

18 Reconnect the TIL cable (labeled “PORT 1”) on the CCM front panel.
...................................................................................................................................................................................................

19 On the xCCM-U-GE or eCCM-U-GE:


• Reinsert the SFP transceiver(s) and / or the SFP cage cover(s) (connector(s) labeled
“MDA”) through the CCM front panel.
PRELIMINARY

• Reconnect the Gigabit Ethernet cable(s) (labeled “MDA”) on the CCM front panel.
• Reconnect the E1/T1 cable if used and / or the PCM connector cover (labeled “PCM
E1/T1”) on the CCM front panel.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-15
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CCM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Important! In case of an CCM module equipped with Multi-Mode (MM) or
Single-Mode (SM) Dual fiber SFP transceivers, put the LC connectors (L/R) in the
same sense as they were before the intervention when reconnecting the optical fibers
on the CCM front panel.
...................................................................................................................................................................................................

20 Insert completely the new CCM module(s) into the 9926 d4U Node B rack by plugging it
into its RBP connectors.
...................................................................................................................................................................................................

21 Power up the 9926 d4U Node B.


To do this, follow the procedure “Powering up a 9926 d4U Node B” (p. A-2), according
to the hardware configuration of the 9926 d4U Node B:
• In mono-controller configuration, switch on the power supply of the both RUCs.
• In dual controller configuration, switch on the RUC power supply of the replaced
CCM.
Attention: In case of the UA7.1 to UA08.1 software upgrade, power up the 9926 d4U
Node B without the CEM modules.
...................................................................................................................................................................................................

22
If the new CCM is... Then...
an xCCM-U Proceed with the Step 23 of this procedure
an eCCM-U Proceed with the Step 1 of the procedure
“Check the eCCM-U LEDs status”

Procedure “Check the eCCM-U LEDs status”:


1. If the tri-color CMA LED 2 is green and blinking, push the
reset button of the eCCM-U for 5 seconds.
2. Check that the tri-color CMA LED 2 is amber.
...................................................................................................................................................................................................

23 Tighten the two screws on the CCM front panel.


...................................................................................................................................................................................................

24 Unlock from the WMS the objects previously locked through the Step 3.
PRELIMINARY

Attention: In case of the UA7.1 to UA08.1 software upgrade, do not unlock the cem
objects.

....................................................................................................................................................................................................................................
10-16 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a CCM

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

25 In case of a standard CCM module replacement, check the state of the LEDs of the both
CEM and CCM modules.
On the xCEM-U and xCCM-U:
• The xCEM-U LEDs should turn on, then take the following state:
– Red LED: OFF.
– Green LED: ON.
• The xCCM-U LEDs should turn on, then take the following state:
– Red LED: OFF.
– Green LED: ON.

• The xCCM-U SYNC LEDs should have the following state:


– Green or amber according to the PCM/MDA synchronization.
• The xCCM-U PCM LEDS and MDA LEDs should be ON.
On the eCEM-U and eCCM-U:
• The eCEM-U LEDs should have the following state:
– Fisrt LED (from top) is OFF
– Second LED (from top) is green
• The eCCM-U CMA LEDs should have the following state:
– LED 1 (“Activity LED”): green
– LED 2 (“Technology LED”): amber in W-CDMA
– LED 3: green
– LED 4: OFF
PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-17
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a CCM
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
• The eCCM-U SYNC LEDs should have the following state:
– Green, red or amber according to the synchronization source selected by the 9926
d4U Node B.
• The eCCM-U MDA LEDs and PCM LEDS status depends on the Iub interface type
(IP-based or hybrid).
Attention: In case of the UA7.1 to UA08.1 software upgrade, check only the CCM
module state of the LEDs as all the CEM modules are out of the rack while the
software upgrade is not achieved.
...................................................................................................................................................................................................

26 The procedure is over in case of a standard CCM module replacement. Otherwise, go to


the next step.
...................................................................................................................................................................................................

27 For a UA7.1 to UA08.1 software upgrade with the TIL, proceed according to the
procedure described in the Alcatel-Lucent 9100 and 93xx Node B - UA08.1
Commissioning and Fault Management User Manual: TIL, NN-20500-019.
...................................................................................................................................................................................................

28 Once the software upgrade is achieved, replace the CEM modules in the 9926 d4U Node
B.
...................................................................................................................................................................................................

29 Unlock from the WMS the cem objects previously locked.


...................................................................................................................................................................................................

30 Check the state of the CEM modules LEDs as described in the Step 25.
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
10-18 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing an optical transceiver

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

Replacing an optical transceiver


Purpose
According to the SFP connection, carry out the following procedure to replace the
defective optical transceiver.

Intervention time
5 minutes

Tools required
None

DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser radiation can cause
considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the
optical source is switched on. Always observe the laser warning instructions.

NOTICE
ESD hazard
Wear the antistatic bracelet when performing the maintenance procedure described
below:
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.

NOTICE
Service-disruption hazard
This procedure causes a loss of service.
Important! There will be a loss of service on the Remote Radio device or on the
PRELIMINARY

dropped BTS in case of BTS daisy chaining through the NodeB

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-19
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing an optical transceiver
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................

1 Open the Node B door(s), if any.


...................................................................................................................................................................................................

2 Locate the faulty SFP transceiver in the labeled “OPTIC” or “MDA” connector: its two
green RX/TX LEDs are OFF.

Figure 10-9 Location of optical connectors in the 9926 d4U Node B

...................................................................................................................................................................................................

3
If the defective SFP transceiver is ... Then...
connected to a remote radio device (connector Continue on with the Step 4 of this procedure
labeled “OPTIC” on the CCM front panel)
connected to the backhaul or to a dropped BTS Go to the “Backhaul procedure” (p. 10-21)
(connector labeled “MDA” on the CCM front
PRELIMINARY

panel)

....................................................................................................................................................................................................................................
10-20 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing an optical transceiver

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

4 At the WMS, through Set Administrative State, lock the FDDCell object associated with
the remote radio device connected to the optical transceiver being replaced.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................

5 Unplug the optical fiber connected to the defective SFP transceiver.


...................................................................................................................................................................................................

6 Pull out with care the defective SFP transceiver of the SFP cage.
...................................................................................................................................................................................................

7 Check that the new replacing SFP transceiver has the same type as the SFP transceiver
being replaced. Be sure to replace a Single Mode (SM) SFP transceiver with a SM SFP
transceiver and a MM SFP transceiver with a MM SFP transceiver.
...................................................................................................................................................................................................

8 Put in place the new SFP transceiver and insert it in the CCM.
...................................................................................................................................................................................................

9 Reconnect the optical fiber.


Important! In case of a CCM module equipped with Multi-Mode (MM) or
Single-Mode (SM) Dual fiber SFP connectors, put the LC connectors (L/R) in the
same sense as they were before the intervention when reconnecting the optical fibers
on the CCM front panel.
...................................................................................................................................................................................................

10 Unlock from the WMS the FDDCell object previously locked through Step 4.
...................................................................................................................................................................................................

11 On the CCM, check that the two green RX/TX OPTIC LEDs are ON.
E...................................................................................................................................................................................................
N D O F S T E P S

Backhaul procedure
...................................................................................................................................................................................................
PRELIMINARY

1 Lock at the WMS through the Set Administrative State command all the objects
associated with the dropped BTS .
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-21
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing an optical transceiver
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

2 Power down the 9926 d4U Node B.


To do this, follow the procedure “Powering down the 9926 d4U Node B”
(p. A-3) according to the 9926 d4U Node B hardware configuration used:
• In mono-controller configuration, cut off the power supply of the both RUCs.
• In dual controller configuration, cut off only the power supply of the RUC linked to
the CCM hosting the defective SFP transceiver.
...................................................................................................................................................................................................

3 Unplug the optical fiber connected to the defective SFP transceiver.


...................................................................................................................................................................................................

4 Pull out with care the defective SFP transceiver of the SFP cage.
...................................................................................................................................................................................................

5 Check that the new replacing SFP transceiver has the same type as the SFP transceiver
being replaced. Be sure to replace a Single Mode (SM) SFP transceiver with a SM SFP
transceiver and a MM SFP transceiver with a MM SFP transceiver.
...................................................................................................................................................................................................

6 Put in place the new SFP transceiver and insert it in the CCM.
...................................................................................................................................................................................................

7 Reconnect the optical fiber.


Important! In case of a CCM module equipped with Multi-Mode (MM) or
Single-Mode (SM) Dual fiber SFP connectors, put the LC connectors (L/R) in the
same sense as they were before the intervention when reconnecting the optical fibers
on the CCM front panel.
...................................................................................................................................................................................................

8 Power up the 9926 d4U Node B.


To do this, follow the procedure “Powering up a 9926 d4U Node B” (p. A-2), according
to the hardware configuration of the 9926 d4U Node B:
• In mono-controller configuration, switch on the power supply of the both RUCs.
• In dual controller configuration, switch on the RUC power supply of the RUC linked
to the CCM hosting the defective SFP transceiver..
...................................................................................................................................................................................................
PRELIMINARY

9 Unlock from the WMS all the objects previously locked through Step 1.

....................................................................................................................................................................................................................................
10-22 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing an optical transceiver

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

10 On the CCM, check that the two green RX/TX MDA LEDs are ON.
E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-23
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the fan rack module
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

Replacing the fan rack module


Purpose
Carry out the following procedure to replace a fan rack module when alarmed.

Intervention time
15 minutes

Tools required
M4 nut driver

Figure 10-10 9926 d4U Node B fan rack module view

WARNING
Safety Hazard, Hardware Damage
Replacing a defective fan try with a different model may damage the hardware and could
represent a potential safety hazard.
When replacing the fan tray, it must be replaced with the same model. Eg: A -48V d2Uv5
fan tray must be replaced by the same model, not a d2Uv2 fan tray or +24V fan tray
PRELIMINARY

model.

....................................................................................................................................................................................................................................
10-24 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the fan rack module

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Wear the antistatic bracelet when performing the maintenance procedure described
below.
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.

Procedure
...................................................................................................................................................................................................

1 Open the Node B door(s), if any.


...................................................................................................................................................................................................

2 Lock the cem object as well as all the objects associated with the Remote Radio devices
connected to the CCM at the WMS, by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................

3 Power down the 9926 d4U Node B.


To do this, follow the procedure “Powering down the 9926 d4U Node B”
(p. A-3) according to the 9926 d4U Node B hardware configuration used:
• In mono-controller configuration, cut off the power supply of the both RUCs.
• In dual controller configuration, cut off only the power supply of the RUC linked to
the defective fan rack module.
• In an Outdoor V1 cabinet configuration, switch the DC breaker switches to OFF.
...................................................................................................................................................................................................

4 Unplug the – 48 V power cable from the RUC front panel with the M4 nut driver.
PRELIMINARY

...................................................................................................................................................................................................

5 Unplug the two Dallas one-wire cables from the connectors labeled "ALARM/INT" on
the RUC front panel.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-25
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the fan rack module
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

6 Using the top handle of the RUC front panel in failure, pull the defective fan rack module
out of the shelf.

Figure 10-11 Extracting a fan rack module


PRELIMINARY

....................................................................................................................................................................................................................................
10-26 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the fan rack module

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
Figure 10-12 RUC and fan rack module

Back
RUC

Front
RUC

Fans Lock

...................................................................................................................................................................................................

7 Put the new fan rack module in place and insert it completely into the 9926 d4U Node B.
...................................................................................................................................................................................................

8 Reconnect the two Dallas one-wire cables to the connectors labeled "ALARM/INT" on
the RUC front panel.
...................................................................................................................................................................................................

9 Reconnect the – 48 V power cable on the RUC front panel with the M4 nut driver.
PRELIMINARY

...................................................................................................................................................................................................

10 Power up the new 9926 d4U Node B.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-27
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the fan rack module
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
To do this, follow the procedure “Powering up a 9926 d4U Node B” (p. A-2), according
to the hardware configuration of the 9926 d4U Node B:
• In mono-controller configuration, switch on the power supply of the both RUCs.
• In dual controller configuration, switch on the RUC power supply of the replaced fan
rack module.
...................................................................................................................................................................................................

11 Unlock from the WMS the objects previously locked through step 1.
...................................................................................................................................................................................................

12 Reprogram the I & C : After replacing the fan tray, the I&C must be re-programed to
match the older one.
Refer to the corresponding procedure in the chapter on Replacing the Pre-cabled Rack,
from , beginning with the step “Connect the TIL” through step “Disconnect the TIL.”
...................................................................................................................................................................................................

13 Check the state of the CCM and CEM LEDs and display.
On the xCCM-U and xCEM-U, the LEDs should take the following states:
• The xCCM-U LEDs should turn on, then take the following state:
– Red LED: OFF.
– Green LED: ON.

• The xCCM-U PCM LEDS and MDA LEDs should be ON.


• The xCCM-U SYNC LEDs should have the following state:
– Green or amber according to the PCM/MDA synchronization.
– The xCCM-U RX/TX OPTIC LEDS should be ON.
• The xCEM-U LEDs should turn on, then take the following state:
– Red LED: OFF.
– Green LED: ON.
PRELIMINARY

....................................................................................................................................................................................................................................
10-28 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the fan rack module

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

• For xCEM-U LEDs:


– First LED (from top): OFF
– Second LED (from top): green
On the eCCM-U and eCEM-U, the LEDs should take the following states:
• For eCCM-U CMA LEDs:
– LED 1 (“Activity LED”): green
– LED 2 (“Technology LED”): amber in W-CDMA
– LED 3: green
– LED 4: OFF

• For eCCM-U SYNC LEDs:


– The LEDs should indicate the synchronization status (PCM or MDA).
• For eCCM-U MDA LEDs:
– At least one LED should be green if at least one MDA port is used.
• For eCCM-U PCM LEDs:
– At least one LED should be green if at least one PCM port is used.
• For eCEM-U LEDs:
– First LED (from top): OFF
– Second LED (from top): green
PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-29
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the fan rack module
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
10-30 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

Replacing the pre-cabled rack


Purpose
Carry out the following procedure to replace the 9926 d4U Node B pre-cabled rack.

Intervention time
40 minutes

Tools required
• A screwdriver
• An extraction tool
• A M4 nut driver
• A wrench for hexagonal head (M5 nut)

DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser radiation can cause
considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the
optical source is switched on. Always observe the laser warning instructions.

NOTICE
ESD hazard
Wear the antistatic bracelet when performing the maintenance procedure described
below:
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions. PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-31
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the pre-cabled rack
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.

Procedure
...................................................................................................................................................................................................

1 Open the Node B door(s), if any.


...................................................................................................................................................................................................

2 Lock the CEM object as well as all the objects associated with the radio device(s)
connected to the CCM at the WMS, by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................

3 Power down the 9926 d4U Node B.


To do this, follow the procedure “Powering down the 9926 d4U Node B” (p. A-3).
Note : In an Outdoor V1 cabinet configuration, switch the DC breaker switches to OFF.
...................................................................................................................................................................................................

4 Unplug the – 48 VDC power cable from each RUC front panel with the M4 nut driver.
...................................................................................................................................................................................................

5 Unplug the ground cable from the ground stud of the rack with the wrench for hexagonal
head (M5 nut).
PRELIMINARY

....................................................................................................................................................................................................................................
10-32 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

6 Remove the management sticker located on the lug, on the right hand side of the 9926
d4U Node B rack.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-33
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the pre-cabled rack
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

Figure 10-13 Location of the management sticker


PRELIMINARY

This removable sticker contains a 6-digit Network IDentifier (NeID) that is used at 9926
d4U Node B connection to the WMS. This sticker must be stored in a safe location since
it will be reused on the new 9926 d4U Node B rack.

....................................................................................................................................................................................................................................
10-34 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

7 Undo and remove the upper and lower hooks (if present).

...................................................................................................................................................................................................

8 Loosen the two screws on each CEM front panel.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-35
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the pre-cabled rack
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

Figure 10-14 Extracting the CEM and CCM

...................................................................................................................................................................................................

9 Using the extraction tool, pull the CEM out of the shelf, see Figure 10-14, “Extracting the
CEM and CCM” (p. 10-36).
...................................................................................................................................................................................................

10 Loosen the two screws on each CCM front panel and pull out a little bit the module.
...................................................................................................................................................................................................

11 Unplug cables from the modules:


• Unplug the CCM module(s) from its RBP connectors using the extraction tool.
• Unplug the GPS synchronization cable (connector labeled "GPS") from the CCM
front panel if used.
PRELIMINARY

• Unplug the optical fiber(s) from the CCM module(s) front panel.
• Unplug the alarm cable (connector labeled "ALARM") from the CCM front panel.
• Unplug the two input/output synchronization cables (connectors labeled "IN" and
"REF OUT") from the CCM front panel if used.

....................................................................................................................................................................................................................................
10-36 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
• Unplug the TIL connection cable (connector labeled "PORT 1") from the CCM front
panel.
• Unplug the Ethernet connection cable (connector labeled "PORT 2") from the CCM
front panel if used.
• Unplug the PCM E1/T1 cable (connector labeled "PCM E1/T1") and the MDA cable
(connector labeled "MDA") from the CCM front panel if used.
...................................................................................................................................................................................................

12 Loosen completely the two screws on the CCM front panel, see Figure 10-14, “Extracting
the CEM and CCM” (p. 10-36).
...................................................................................................................................................................................................

13 Using the extraction tool, pull the CCM module(s) out of the shelf, see Figure 10-14,
“Extracting the CEM and CCM” (p. 10-36).
...................................................................................................................................................................................................

14 Remove the defective 9926 d4U Node B rack by unscrewing its eight screws (four screws
on each side).
...................................................................................................................................................................................................

15 Put the new 9926 d4U Node B rack in place and fix the rack with its eight screws.
...................................................................................................................................................................................................

16 Fix the NeID sticker on the right hand side of the RUC, on the lug of the new 9926 d4U
Node B rack.
...................................................................................................................................................................................................

17 Reinsert the CEM module(s) in the new digital shelf.


...................................................................................................................................................................................................

18 Reinsert the CCM module(s) in the new digital shelf without plugging it on the RBP
d4Uv3.
...................................................................................................................................................................................................

19 Reconnect the – 48 VDC power cable to the RUC front panel with the M4 nut driver.
...................................................................................................................................................................................................

20 Reconnect the ground cable to the ground stud of the rack with the wrench for hexagonal
head (M5 nut).
PRELIMINARY

...................................................................................................................................................................................................

21 Reconnect all cables and fiber(s) disconnected in theStep 11.


Important! In case of a CCM module equipped with Multi-Mode (MM) or
Single-Mde (SM) Dual fiber SFP transceivers, put the LC connectors (L/R) in the
same sense as they were before the intervention.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-37
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the pre-cabled rack
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

22 Insert completely the CCM module(s) into the digital shelf by plugging it into its RBP
connectors.
...................................................................................................................................................................................................

23 Tighten the two screws on the CCM, CEM and RUC front panel.
...................................................................................................................................................................................................

24 Put the two hooks in place and secure them, see “Procedure” (p. 10-35).
...................................................................................................................................................................................................

25 Power up the new 9926 d4U Node B.


To do this, follow the procedure “Powering up a 9926 d4U Node B” (p. A-2)
...................................................................................................................................................................................................

26 Unlock from the WMS the objects previously locked through Step 2.
...................................................................................................................................................................................................

27 Connect the TIL on the 9926 d4U Node B on "PORT1" of the CCM to modify the
pre-cabled rack inventory parameters.
...................................................................................................................................................................................................

28 Launch the TIL.


...................................................................................................................................................................................................

29 Go to the I&C menu.


PRELIMINARY

....................................................................................................................................................................................................................................
10-38 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

30 Choose the Change I&C parameters menu.

...................................................................................................................................................................................................

31 In the Change I&C parameters window, choose the BTS tab.


The Serial Number, and Manufacturing Date fields in this tab are linked with the
defective 9926 d4U Node B rack. This information must be updated.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-39
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the pre-cabled rack
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

32 In the Fallback to previous I&C data field, choose Deactivate.


PRELIMINARY

....................................................................................................................................................................................................................................
10-40 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

33 Using the information printed on the pre-cabled rack labels present on the left hand side
of the 9926 d4U Node B spare, fill out the following fields:
• Serial Number
• Manufacturing Date

Click Send to iBTS.


...................................................................................................................................................................................................

34 In the Flip/Flop Mechanism window, click Yes.

PRELIMINARY

...................................................................................................................................................................................................

35 In the Change I&C parameters Info window, click OK.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-41
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the pre-cabled rack
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

36 Wait during the operation.

...................................................................................................................................................................................................

37 At the end of the operation, the following message is displayed:

...................................................................................................................................................................................................

38 Go to the Tools menu.


...................................................................................................................................................................................................

39 Choose iBTS reset, then Reset in connected mode.


PRELIMINARY

....................................................................................................................................................................................................................................
10-42 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

40 In the Confirm the reset window, click OK.


...................................................................................................................................................................................................

41 In the End of Reset window, click OK.


...................................................................................................................................................................................................

42 Exit the TIL.


...................................................................................................................................................................................................

43 Disconnect the TIL from the 9926 d4U Node B.


...................................................................................................................................................................................................

44 Modify “NEID” of the BTSEquipment object at the WMS.


Note: “NEID” value is equal to the serialization number at the TIL.
Note: Only one of the two RUCs should be configured with the correct NEID; the
PRELIMINARY

other RUC should have the NEID with “000000” as a spare. It is possible to manage
only one NEID per DBS 4U.
...................................................................................................................................................................................................

45 Check the state of BTSEquipment OAM Link at the WMS is recovered.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-43
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the pre-cabled rack
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

46 Check the state of the CCM and CEM LEDs and display.
On the xCEM-U and xCCM-U:
• The xCEM-U LEDs should turn on, then take the following state:
– Red LED: OFF.
– Green LED: ON.
• The xCCM-U LEDs should turn on, then take the following state:
– Red LED: OFF.
– Green LED: ON.

• The xCCM-U SYNC LEDs should have the following state:


– Green or amber according to the PCM/MDA synchronization.
• The xCCM-U PCM LEDS and MDA LEDs should be ON.
On the eCEM-U and eCCM-U:
• The eCEM-U LEDs should have the following state:
– Green LED: ON
– Red LED: OFF
• The eCCM-U CMA LEDs should have the following state:
– LED 1 (“Activity LED”): green
– LED 2 (“Technology LED”): amber in W-CDMA
– LED 3: green
– LED 4: OFF
PRELIMINARY

....................................................................................................................................................................................................................................
10-44 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the pre-cabled rack

PRELIMINARY
Replacing the 9926 d4U digital shelf equipment
....................................................................................................................................................................................................................................
• The eCCM-U SYNC LEDs should have the following state:
– Green, red or amber according to the synchronization source selected by the 9926
d4U Node B.
• The eCCM-U MDA LEDs and PCM LEDS status depends on the Iub interface type
(IP-based or hybrid).

E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-45
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Overview
Replacing the RF block equipment
....................................................................................................................................................................................................................................

Replacing the RF block equipment

Overview
Purpose
This section presents the replacement procedures applicable to the RF block of a 9311
Macro V1 OD with d4U.

Contents

9311 Macro V1 OD with d4U: Replacing a TRDU 10-47


PRELIMINARY

....................................................................................................................................................................................................................................
10-46 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing a TRDU

PRELIMINARY
Replacing the RF block equipment
....................................................................................................................................................................................................................................

9311 Macro V1 OD with d4U: Replacing a TRDU


Carry out the following procedure to replace a TRDU in a 9311 Macro V1 OD with d4U
in the digital shelf.
Important! Mixity restriction : TRDU model mixity is not allowed within a cluster.
Note: Make sure that the TRDU module type used as a spare part is identical to the
one to be replaced in the TRDU shelf (TRDU60-21, TRDU60-21B). The left and right
parts of the shelf must consist of three modules of the same type per sector (for
example, S1: TRDU60-21, S2: TRDU60-21B).
Note: To exchange a faulty TRDU module, replace it with a module of the same type
in a group of three identical modules.

Intervention time
15 minutes

Tools required
• 7/16 torque wrench
• Phillips screwdriver
• Extraction tool (3JR08430AA)

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-47
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing a TRDU
Replacing the RF block equipment
....................................................................................................................................................................................................................................

Figure 10-15 TRDU60–21 front panel


PRELIMINARY

....................................................................................................................................................................................................................................
10-48 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing a TRDU

PRELIMINARY
Replacing the RF block equipment
....................................................................................................................................................................................................................................
Figure 10-16 TRDU60-21B front panel

CAUTION
Burn hazard
Module becomes very hot during operation.
Wear gloves when removing the module.
PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-49
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing a TRDU
Replacing the RF block equipment
....................................................................................................................................................................................................................................
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Important! Service is lost on the radio links associated with the TRDU being
replaced.
Important! The 7/16 tightening torque must be 25 N.m (24 N.m to 27 N.m).
Important! Respect bend radius of cables while tightening connectors.
Pay attention to cable torsion and bend radius during maintenance operations.

Procedure
...................................................................................................................................................................................................

1 Locate the faulty TRDU in the TRDU shelf: its red LED is on.
...................................................................................................................................................................................................

2 At the OMC, lock the faulty TRDU by Set Administrative State. For more information,
refer to Alcatel-Lucent 9353 Wireless Management System - User Guide,
9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................

3 Switch off the faulty TRDU (on the TRDU front panel, put the power switch in the "O"
position).
PRELIMINARY

....................................................................................................................................................................................................................................
10-50 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing a TRDU

PRELIMINARY
Replacing the RF block equipment
....................................................................................................................................................................................................................................

Figure 10-17 Power switch on the TRDU front panel

...................................................................................................................................................................................................

4 On the front panel of the faulty TRDU, disconnect the following cables:
• The two RF antenna cables (connectors labeled "RX" and "TX/RX"), using the 7/16
wrench
• The CPRI cable (connector labeled "DATA I/O SLAVE")
• The AISG input digital cable (9-pin D-SUB connector labeled "AISG IN"), if CCU
for RETA is used
...................................................................................................................................................................................................

5 Important! Beware that if you do not disconnect the power cable at the
interconnection module, there is a risk of destroying the equipment, because of a
PRELIMINARY

connected -48 V cable hanging down.


First, remove the power cable at the interconnection module (do not remove the data
cable). Then, in front of the faulty TRDU module, disconnect the power cable that is
connected to the "Power IN" connector.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-51
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing a TRDU
Replacing the RF block equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

6 Untighten the four TRDU front panel screws using the Phillips screwdriver.
...................................................................................................................................................................................................

7 Remove the defective TRDU using the extraction tool.


...................................................................................................................................................................................................

8 Remove the depth adaptor from the defective TRDU, and mount onto the new TRDU.
...................................................................................................................................................................................................

9 Insert the new TRDU.


...................................................................................................................................................................................................

10 Tighten the four screws on the new TRDU front panel using the Phillips screwdriver.
...................................................................................................................................................................................................

11 Check that the power switch on the new TRDU is in the "O" position.
...................................................................................................................................................................................................

12 On the new TRDU front panel, connect the power cable to the "POWER IN" connector.
...................................................................................................................................................................................................

13 DANGER
Personnel protection
When connecting the power cable to the interconnection module, be careful not to touch
the interconnection module.
Connect the power cable to the interconnection module.
...................................................................................................................................................................................................

14 On the new TRDU front panel, connect the following cables:


• The AISG input digital cable (9-pin D-SUB connector labeled "AISG IN"), if required
• The CPRI cable (connector labeled "DATA I/O SLAVE")
• The two RF antenna cables (connectors labeled "RX" and "TX/RX"), using the 7/16
wrench
...................................................................................................................................................................................................

15 Switch on the new TRDU (on the TRDU front panel, put the power switch in the "I"
position).
PRELIMINARY

The TRDU is automatically unlocked.


During TRDU startup, the green and red LEDs on TRDU front panel are on.
Wait for TRDU startup.

....................................................................................................................................................................................................................................
10-52 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing a TRDU

PRELIMINARY
Replacing the RF block equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

16 If the TRDU is not automatically unlocked, unlock the TRDU at the OMC by Set
Administrative State. For more information, refer to Alcatel-Lucent 9353 Wireless
Management System - User Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................

17 On the CCM-U front panel, for the CPRI port concerned, check that the Tx and Rx LEDs
are green (the communication is established between the 9311 Macro V1 OD and the new
TRDU).
...................................................................................................................................................................................................

18 On the TRDU front panel, check that:


• The green LED is on.
• The red LED is off.

E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-53
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Overview
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

Replacing the cooling system equipment

Overview
Purpose
This section presents the replacement procedures applicable to the cooling systems of the
9311 Macro V1 OD.

Contents

Replacing the Direct Ambient Cooling System (DACS) of the 9311 Macro V1 10-55
OD
Replacing the iDACS blowers of the 9311 Macro V1 OD 10-59
Replacing the iDACS control board of the 9311 Macro V1 OD 10-61
Replacing the iDACS heaters of the 9311 Macro V1 OD 10-66
Replacing the iDACS air filter of the 9311 Macro V1 OD 10-68
PRELIMINARY

....................................................................................................................................................................................................................................
10-54 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Direct Ambient Cooling System (DACS) of the

PRELIMINARY
Replacing the cooling system equipment 9311 Macro V1 OD
....................................................................................................................................................................................................................................

Replacing the Direct Ambient Cooling System (DACS) of the


9311 Macro V1 OD
Purpose
Carry out the following procedure to replace the DACS. Replace the whole DACS instead
of replacing the control board.
This intervention requires the presence of two persons. The weight of the DACS is 31kg.

Intervention time
Ten minutes

Tools required
Screwdriver

CAUTION
Service interruption
This procedure requires a service interruption of the 9311 Macro V1 OD estimated at ten
minutes.

Procedure
...................................................................................................................................................................................................

1 Open the doors of the Node B.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-55
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Direct Ambient Cooling System (DACS) of the
Replacing the cooling system equipment 9311 Macro V1 OD
....................................................................................................................................................................................................................................

Figure 10-18 DACS location

...................................................................................................................................................................................................

2 Switch off the iDACS circuit breaker on the DC power system shelf.
...................................................................................................................................................................................................

3 Switch off the AC connector to the DACS and the heaters (CB02, CB04 and CB06 on the
AC box).
...................................................................................................................................................................................................

4 On the right-hand side of the iDACS, disconnect the AC connector.


...................................................................................................................................................................................................

5 On the left-hand side of the iDACS, disconnect the DC connector and the MCA alarm
connector.
...................................................................................................................................................................................................

6 Remove the stiffener located in the middle of the iDACS.


PRELIMINARY

....................................................................................................................................................................................................................................
10-56 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Direct Ambient Cooling System (DACS) of the

PRELIMINARY
Replacing the cooling system equipment 9311 Macro V1 OD
....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

7 Remove the four screws, two on each side, securing the iDACS to the 9311 Macro V1
OD. Remove the loop cable fastener retaining the tempature probe at the back of the 9311
Macro V1 OD.

...................................................................................................................................................................................................

8 Lift the iDACS by the handles located on each side of the iDACS and remove it from the
9311 Macro V1 OD.
PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-57
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Direct Ambient Cooling System (DACS) of the
Replacing the cooling system equipment 9311 Macro V1 OD
....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

9 Place the new iDACS in the 9311 Macro V1 OD and secure it with the four screws (two
on each side).
...................................................................................................................................................................................................

10 Replace the stiffener.


...................................................................................................................................................................................................

11 On the left-hand side, reconnect the DC connector and the MCA alarm connector.
...................................................................................................................................................................................................

12 On the right-hand side, reconnect the ac connector.


...................................................................................................................................................................................................

13 Switch on the iDACS circuit breaker on the DC power system shelf.


...................................................................................................................................................................................................

14 Close the doors of the Node B.


E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
10-58 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS blowers of the 9311 Macro V1 OD

PRELIMINARY
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

Replacing the iDACS blowers of the 9311 Macro V1 OD


Purpose
There are two blowers per iDACS.
Carry out the following procedure to replace the blowers.

Intervention time
20 minutes

Tools required
Screwdriver

CAUTION
Service interruption
This procedure requires a service interruption of the 9311 Macro V1 OD estimated at 20
minutes.

Procedure
...................................................................................................................................................................................................

1 Open the doors of the Node B.

Figure 10-19 iDACS location

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-59
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS blowers of the 9311 Macro V1 OD
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

2 Remove the iDACS. Refer to the “Replacing the Direct Ambient Cooling System
(DACS) of the 9311 Macro V1 OD” (p. 10-55) procedure.
...................................................................................................................................................................................................

3 Open the iDACS.


...................................................................................................................................................................................................

4 Remove the defective blowers.

...................................................................................................................................................................................................

5 Insert the new blowers.


...................................................................................................................................................................................................

6 Close the iDACS.


...................................................................................................................................................................................................

7 Insert the iDACS. Refer to the “Replacing the Direct Ambient Cooling System (DACS)
of the 9311 Macro V1 OD” (p. 10-55) procedure.
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
10-60 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS control board of the 9311 Macro V1 OD

PRELIMINARY
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

Replacing the iDACS control board of the 9311 Macro V1 OD


Purpose
Carry out the following procedure to replace the iDACS control board in the 9311 Macro
V1 OD.

Intervention time
30 minutes

Tools required
• Flat screwdriver
• Phillips screwdriver

CAUTION
Service interruption
This procedure requires a service interruption from the 9311 Macro V1 OD for 30
minutes.

CAUTION
New iDACS product reference
When replacing old NTUM81CA module by a new one NTUM81EA module, put the new
reference sticker on the old sticker.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-61
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS control board of the 9311 Macro V1 OD
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

Figure 10-20 iDACS control board


PRELIMINARY

....................................................................................................................................................................................................................................
10-62 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS control board of the 9311 Macro V1 OD

PRELIMINARY
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................

1 Open the doors of the 9311 Macro V1 OD.


...................................................................................................................................................................................................

2 Locate the iDACS control board.

Figure 10-21 Location of the iDACS control board in the 9311 Macro V1 OD

...................................................................................................................................................................................................

3 Power down the 9311 Macro V1 OD. Refer to the “Powering down a 9311 Macro V1 OD
with d4U” (p. 8-10) procedure.
...................................................................................................................................................................................................

4 Remove the iDACS. Refer to the “Replacing the Direct Ambient Cooling System
(DACS) of the 9311 Macro V1 OD” (p. 10-55) procedure.
...................................................................................................................................................................................................

5 Loosen the eight screws of the case which contains the iDACS control board. This case is
situated on the side of the iDACS.
...................................................................................................................................................................................................

6 Remove the iDACS control board case.


PRELIMINARY

...................................................................................................................................................................................................

7 Locate the connectors of the iDACS control board.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-63
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS control board of the 9311 Macro V1 OD
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

Figure 10-22 Location of the connectors of the iDACS control board

...................................................................................................................................................................................................

8 Disconnect all the cables from the iDACS control board and mark them.
...................................................................................................................................................................................................

9 Loosen the six screws which maintain the iDACS control board in the case.
...................................................................................................................................................................................................

10 Remove the defective iDACS control board.


PRELIMINARY

...................................................................................................................................................................................................

11 Insert the new iDACS control board.


...................................................................................................................................................................................................

12 Tighten the six screws which maintain the iDACS control board in the case.
....................................................................................................................................................................................................................................
10-64 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS control board of the 9311 Macro V1 OD

PRELIMINARY
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

13 Reconnect all the cables from the iDACS control board following the marks.
...................................................................................................................................................................................................

14 Install the iDACS control board case in the iDACS.


...................................................................................................................................................................................................

15 Tighten the eight screws of the case which contains the iDACS control board.
...................................................................................................................................................................................................

16 Insert the iDACS. Refer to the “Replacing the Direct Ambient Cooling System (DACS)
of the 9311 Macro V1 OD” (p. 10-55) procedure.
...................................................................................................................................................................................................

17 Power up the 9311 Macro V1 OD. Refer to the “Powering up a 9311 Macro V1 OD with
d4U” (p. 8-2) procedure.
...................................................................................................................................................................................................

18 Stick the label on the iDACS case for modify the product reference code (PEC code).
...................................................................................................................................................................................................

19 Close the doors of the 9311 Macro V1 OD.


E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-65
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS heaters of the 9311 Macro V1 OD
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

Replacing the iDACS heaters of the 9311 Macro V1 OD


Purpose
Carry out the following procedure to replace the iDACS heaters.

Intervention time
20 minutes

Tools required
screwdriver

CAUTION
Service interruption
This procedure requires a service interruption of the 9311 Macro V1 OD estimated at 20
minutes.

Procedure
...................................................................................................................................................................................................

1 Open the doors of the 9311 Macro V1 OD.

Figure 10-23 iDACS location


PRELIMINARY

....................................................................................................................................................................................................................................
10-66 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS heaters of the 9311 Macro V1 OD

PRELIMINARY
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

2 Remove the iDACS. Refer to the “Replacing the Direct Ambient Cooling System
(DACS) of the 9311 Macro V1 OD” (p. 10-55) procedure.
...................................................................................................................................................................................................

3 Open the iDACS.


...................................................................................................................................................................................................

4 Unscrew the nut connecting the red cable.


...................................................................................................................................................................................................

5 Remove the grid to access the heaters.


...................................................................................................................................................................................................

6 Remove the metal attachments.


...................................................................................................................................................................................................

7 Remove the defective heater.


...................................................................................................................................................................................................

8 Insert the new heater.


...................................................................................................................................................................................................

9 Put the grid back on.


...................................................................................................................................................................................................

10 Close the iDACS.


...................................................................................................................................................................................................

11 Insert the iDACS. Refer to the “Replacing the Direct Ambient Cooling System (DACS)
of the 9311 Macro V1 OD” (p. 10-55) procedure.
E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-67
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS air filter of the 9311 Macro V1 OD
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

Replacing the iDACS air filter of the 9311 Macro V1 OD


Purpose
Carry out the following procedure to replace the air filter.
This procedure does not require:
• service interruption of the 9311 Macro V1 OD
• removal of the iDACS from the 9311 Macro V1 OD

Intervention time
Ten minutes

Tools required
Screwdriver

Procedure
...................................................................................................................................................................................................

1 Open the doors of the 9311 Macro V1 OD.


...................................................................................................................................................................................................

2 Locate the iDACS.

Figure 10-24 iDACS location


PRELIMINARY

....................................................................................................................................................................................................................................
10-68 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS air filter of the 9311 Macro V1 OD

PRELIMINARY
Replacing the cooling system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

3 Remove the stiffener located in the middle of the iDACS.

...................................................................................................................................................................................................

4 Unscrew the four 1/4 turn fixings of the filter holder and remove the holder.

...................................................................................................................................................................................................

5 Remove the defective air filter.


PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-69
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS air filter of the 9311 Macro V1 OD
Replacing the cooling system equipment
....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

6 Insert the new air filter in the iDACS.


...................................................................................................................................................................................................

7 Replace the filter holder and secure it with the four 1/4 turn fixings.
...................................................................................................................................................................................................

8 Replace the stiffener.


...................................................................................................................................................................................................

9 Close the doors of the 9311 Macro V1 OD.


E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
10-70 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Overview

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing the power system equipment

Overview
Purpose
This section presents the replacement procedures applicable to the power system.

Contents

Replacing the dc power system shelf 10-72


Replacing the filtering box 10-75
Replacing a lightning protector of the ac filter box 10-82
Replacing the iDACS ac breaker 10-87
Replacing the Single Power Control Module (SPCM) 10-94
Replacing a rectifier 10-97
Replacing the rectifier ac breaker 10-100
Replacing the DC Breaker Panel 10-105
Replacing the batteries of the 9311 Macro V1 OD 10-109

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-71
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the dc power system shelf
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing the dc power system shelf


Purpose
Carry out the following procedure to replace the dc power system shelf.
The dc power system shelf is composed of:
• the dc distribution module
• the SPCM
• the rectifiers

Intervention time
One hour

Tools required
Open wrench

Figure 10-25 Front view of the dc power system shelf


PRELIMINARY

Procedure
...................................................................................................................................................................................................

1 Open the doors of the 9311 Macro V1 OD.

....................................................................................................................................................................................................................................
10-72 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the dc power system shelf

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

2 Locate the dc power system shelf.

Figure 10-26 Location of the dc power system shelf in the 9311 Macro V1 OD

...................................................................................................................................................................................................

3 CAUTION
Service Interruption
This procedure requires a service interruption from the 9311 Macro V1 OD at one hour.

Power down the BTS. Refer to the “Powering down a 9311 Macro V1 OD with d4U”
(p. 8-10) procedure.
...................................................................................................................................................................................................

4 Loosen the two front panel screws of all the rectifiers (or fillers) and remove them except
for the one located on the right-hand side: it will be useful to have the handles of this
rectifier to remove the dc power system shelf.
...................................................................................................................................................................................................

5 On the SPCM, disconnect the thermal probe connector and the alarm bus cable.
...................................................................................................................................................................................................
PRELIMINARY

6 Using an open wrench, remove the four nuts securing the dc power system shelf to the
9311 Macro V1 OD.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-73
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the dc power system shelf
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

7 Lift the dc power system shelf using the handles of the remaining rectifiers/fillers and of
the SPCM. Remove it.
...................................................................................................................................................................................................

8 Insert the new empty dc power system shelf.


...................................................................................................................................................................................................

9 Insert one rectifier or filler on the right-hand side of the dc power system shelf and secure
it with the two front panel screws.
...................................................................................................................................................................................................

10 Using the rectifier/filler handle and the SPCM handle, replace the dc power system shelf
in the 9311 Macro V1 OD.
...................................................................................................................................................................................................

11 Tighten, with a wrench, the four nuts securing the dc power system shelf to the 9311
Macro V1 OD.
...................................................................................................................................................................................................

12 Replace all the rectifiers/fillers and secure them with the two front panel screws.
...................................................................................................................................................................................................

13 At the front of the SPCM, reconnect: the thermal probe connector and the alarm bus
cable.
...................................................................................................................................................................................................

14 Perform the operations for return to service. Refer to the “Powering up a 9311 Macro V1
OD with d4U” (p. 8-2) procedure.
...................................................................................................................................................................................................

15 Close the doors of the 9311 Macro V1 OD.


E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
10-74 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the filtering box

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing the filtering box


Purpose
Carry out the following procedure to replace the filtering box.

Intervention time
20 minutes

Tools required
• Flat screwdriver
• Phillips screwdriver
• 10mm open wrench

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-75
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the filtering box
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 10-27 Front view of the single phase filtering box


PRELIMINARY

....................................................................................................................................................................................................................................
10-76 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the filtering box

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Figure 10-28 Front view of the split-phase filtering box (US)

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-77
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the filtering box
Replacing the power system equipment
....................................................................................................................................................................................................................................
Figure 10-29 Front view of the split-phase filtering box
PRELIMINARY

....................................................................................................................................................................................................................................
10-78 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the filtering box

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Figure 10-30 Front view of the triphase filtering box

Procedure
...................................................................................................................................................................................................

1 CAUTION
PRELIMINARY

Service interruption
The service will be interrupted if the batteries are not present or discharged.

Open the doors of the 9311 Macro V1 OD.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-79
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the filtering box
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 10-31 Location of the filtering box in the 9311 Macro V1 OD

...................................................................................................................................................................................................

2 CAUTION
Electric-shock hazard
Personnel safety rules: the personnel performing this check must wear rubber gloves and
must be isolated from the ground.
The 9311 Macro V1 OD remains supplied with the mains power supply.
There is a risk of sparks during the test.

Power down the customer ac.


...................................................................................................................................................................................................

3 Disconnect all the cables of the filtering box:


• the ground cable at the bottom of the filtering box (use the open wrench)
• the MCA internal alarm cable located below the plug (use the flat screwdriver)
...................................................................................................................................................................................................

4 Loosen the two screws located at the top of the filtering box (use the Philips screwdriver).
...................................................................................................................................................................................................
PRELIMINARY

5 Extract the defective filtering box with the handle and remove it.
...................................................................................................................................................................................................

6 Insert the new filtering box in its place.

....................................................................................................................................................................................................................................
10-80 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the filtering box

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

7 Tighten the two securing screws located at the top of the filtering box.
...................................................................................................................................................................................................

8 Reconnect the following cables:


• the ground cable
• the MCA internal alarm cable
...................................................................................................................................................................................................

9 Power on the AC differential breaker.


...................................................................................................................................................................................................

10 Close the doors of the 9311 Macro V1 OD.


E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-81
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a lightning protector of the ac filter box
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing a lightning protector of the ac filter box


Purpose
Carry out the following procedure to replace a lightning protector of the ac filter box.

Intervention time
Five minutes

Tools required
Screwdriver

Procedure
...................................................................................................................................................................................................

1 Open the doors.


...................................................................................................................................................................................................

2 Put the BTS site ac main breaker in the OFF position.


...................................................................................................................................................................................................

3 Put the six ac circuit breakers in the OFF position.


...................................................................................................................................................................................................

4 Loosen the four fixing screws at the bottom of the ac filter box and open the box: the
lightning protectors are located inside.
PRELIMINARY

....................................................................................................................................................................................................................................
10-82 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a lightning protector of the ac filter box

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 10-32 Front view of the ac filter box

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-83
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a lightning protector of the ac filter box
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

5 Identify the faulty lightning protector: the color of its rectangular mechanical indicator
has turned from white to red.
...................................................................................................................................................................................................

6 Remove the faulty lightning protector.


PRELIMINARY

....................................................................................................................................................................................................................................
10-84 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a lightning protector of the ac filter box

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 10-33 Internal view of the ac filter box

PRELIMINARY

...................................................................................................................................................................................................

7 Insert the new lightning protector.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-85
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a lightning protector of the ac filter box
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

8 Put the ac filter box front panel back and tighten the four fixing screws.
...................................................................................................................................................................................................

9 Put the six ac circuit breakers in the ON position.


...................................................................................................................................................................................................

10 Put the BTS site ac main breaker in the ON position.


...................................................................................................................................................................................................

11 Close the doors.


...................................................................................................................................................................................................

12 Call for the OMC in order to confirm that lightning protection alarm has disappeared and
check that another alarm has not been generated (for example, by one of the six ac circuit
breakers still in the OFF position).
E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
10-86 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS ac breaker

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing the iDACS ac breaker


Purpose
The iDACS ac breaker is a magnetic circuit breaker with a yellow rocker situated in front
of the ac distribution module.
Carry out the following procedure to replace the iDACS ac breaker in the 9311 Macro V1
OD.

Intervention time
30 minutes

Tools required
• Flat screwdriver
• Phillips screwdriver

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-87
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS ac breaker
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 10-34 Front view of the 3 iDACS ac breakers with a yellow rocker situated
in the ac distribution module
PRELIMINARY

....................................................................................................................................................................................................................................
10-88 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS ac breaker

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................

1 Open the doors of the 9311 Macro V1 OD.


...................................................................................................................................................................................................

2 Locate the iDACS ac breaker with a yellow rocker.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-89
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS ac breaker
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 10-35 Location of the iDACS ac breaker in the 9311 Macro V1 OD


PRELIMINARY

....................................................................................................................................................................................................................................
10-90 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS ac breaker

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

3 CAUTION
Service interruption
This procedure requires a service interruption from the 9311 Macro V1 OD for 30
minutes.

Power down the 9311 Macro V1 OD. Refer to the “Powering down a 9311 Macro V1 OD
with d4U” (p. 8-10) procedure.
...................................................................................................................................................................................................

4 Loosen the six screws on the front of ac distribution module.


...................................................................................................................................................................................................

5 CAUTION
ac distribution module
The ac distribution module is connected to iDACS ac breakers and rectifier ac breakers
cables. Its handling must be done gently.

Remove gently the ac distribution module.


...................................................................................................................................................................................................

6 Locate the connectors of the iDACS ac breaker.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-91
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the iDACS ac breaker
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 10-36 Location of the connectors of the iDACS ac breaker

...................................................................................................................................................................................................

7 Loosen the two screws on the back of iDACS ac breaker which maintain the two iDACS
ac breaker cables.
...................................................................................................................................................................................................

8 Disconnect the two iDACS ac breaker cables.


...................................................................................................................................................................................................

9 Loosen the two screws on the front of iDACS ac breaker.


...................................................................................................................................................................................................
PRELIMINARY

10 Remove the iDACS ac breaker.


...................................................................................................................................................................................................

11 Insert the new iDACS ac breaker.

....................................................................................................................................................................................................................................
10-92 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the iDACS ac breaker

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

12 Tighten the two screws on the front of iDACS ac breaker.


...................................................................................................................................................................................................

13 Connect the two iDACS ac breaker cables.


...................................................................................................................................................................................................

14 Tighten the two screws on the back of iDACS ac breaker which maintain the two iDACS
ac breaker cables.
...................................................................................................................................................................................................

15 Insert gently the ac distribution module in the 9311 Macro V1 OD.


...................................................................................................................................................................................................

16 Tighten the six screws on the front of ac distribution module.


...................................................................................................................................................................................................

17 Power up the 9311 Macro V1 OD. Refer to the “Powering up a 9311 Macro V1 OD with
d4U” (p. 8-2) procedure.
...................................................................................................................................................................................................

18 Close the doors of the 9311 Macro V1 OD.


E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-93
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Single Power Control Module (SPCM)
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing the Single Power Control Module (SPCM)


Purpose
The SPCM is located in the 9311 Macro V1 OD cabinet.
The SPCM board is hot-swappable, therefore no power-down is required.
Carry out the following procedure to replace the SPCM.

Intervention time
Ten minutes

Tools required
Screwdriver
PRELIMINARY

....................................................................................................................................................................................................................................
10-94 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Single Power Control Module (SPCM)

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 10-37 Front view of the SPCM

Procedure
...................................................................................................................................................................................................

1 Open the doors of the 9311 Macro V1 OD. PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-95
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Single Power Control Module (SPCM)
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 10-38 Location of the SPCM

...................................................................................................................................................................................................

2 Disconnect the two connectors at the front of the SPCM: Bus alarm and Thermal probe.
...................................................................................................................................................................................................

3 Loosen the two SPCM front panel screws.


...................................................................................................................................................................................................

4 Remove the defective SPCM using the front panel handle.


...................................................................................................................................................................................................

5 Insert the new SPCM.


...................................................................................................................................................................................................

6 Reconnect the two connectors.


...................................................................................................................................................................................................

7 Check the state of the LEDs. They should go on, then take the following states.
green LED ON, red SPCM Fail, Thermal Probe Fail, REC Fail, and CEATS LEDs OFF
...................................................................................................................................................................................................

8 Close the doors of the 9311 Macro V1 OD.


PRELIMINARY

E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
10-96 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a rectifier

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing a rectifier
Purpose
Carry out the following procedure to replace a rectifier.

Intervention time
Ten minutes

Tools required
Screwdriver

Figure 10-39 Front view of a rectifier

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-97
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing a rectifier
Replacing the power system equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................

1 Open the door(s) of the 9311 Macro V1 OD.


...................................................................................................................................................................................................

2 Locate the faulty rectifier: its green LED is OFF.

Figure 10-40 Location of the rectifier in the 9311 Macro V1 OD

The rectifier number depends on the configuration type.


...................................................................................................................................................................................................

3 Switch off the rectifier.


...................................................................................................................................................................................................

4 Loosen the two rectifier front panel screws.


...................................................................................................................................................................................................

5 Remove the defective rectifier using the front panel handle.


PRELIMINARY

...................................................................................................................................................................................................

6 Insert the new rectifier in the dc power system shelf.


...................................................................................................................................................................................................

7 Switch on the rectifier.


....................................................................................................................................................................................................................................
10-98 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing a rectifier

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

8 Check the state of the LED. It should go on, then take the following state:
green LED ON
...................................................................................................................................................................................................

9 Close the door(s) of the 9311 Macro V1 OD.


E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-99
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the rectifier ac breaker
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing the rectifier ac breaker


Purpose
The rectifier ac breaker is a magnetic circuit breaker with a blue rocker situated in front
of the ac distribution module.
Carry out the following procedure to replace the rectifier ac breaker in the 9311 Macro
V1 OD.

Intervention time
30 minutes

Tools required
• Flat screwdriver
• Phillips screwdriver
PRELIMINARY

....................................................................................................................................................................................................................................
10-100 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the rectifier ac breaker

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 10-41 Front view of the 3 rectifiers ac breakers with a blue rocker situated
in the ac distribution module

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-101
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the rectifier ac breaker
Replacing the power system equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................

1 Open the doors of the 9311 Macro V1 OD.


...................................................................................................................................................................................................

2 Locate the rectifier ac breaker with a blue rocker.

Figure 10-42 Location of the rectifier ac breaker in the 9311 Macro V1 OD

...................................................................................................................................................................................................

3 CAUTION
Service interruption
This procedure requires a service interruption from the 9311 Macro V1 OD for 30
minutes.

Power down the 9311 Macro V1 OD. Refer to the “Powering down a 9311 Macro V1 OD
with d4U” (p. 8-10) procedure.
...................................................................................................................................................................................................

4 Loosen the six screws on the front of ac distribution module.


...................................................................................................................................................................................................

CAUTION
PRELIMINARY

5
ac distribution module
The ac distribution module is connected to iDACS ac breakers and rectifier ac breakers
cables. Its handling must be done gently.

....................................................................................................................................................................................................................................
10-102 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the rectifier ac breaker

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
Remove gently the ac distribution module.
...................................................................................................................................................................................................

6 Locate the connectors of the rectifier ac breaker.

Figure 10-43 Location of the connectors of the rectifier ac breaker

...................................................................................................................................................................................................

7 Loosen the two screws on the back of rectifier ac breaker which maintain the two rectifier
ac breaker cables.
...................................................................................................................................................................................................

8 Disconnect the two rectifier ac breaker cables.


...................................................................................................................................................................................................
PRELIMINARY

9 Loosen the two screws on the front of rectifier ac breaker.


...................................................................................................................................................................................................

10 Remove the rectifier ac breaker.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-103
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the rectifier ac breaker
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

11 Insert the new rectifier ac breaker.


...................................................................................................................................................................................................

12 Tighten the two screws on the front of rectifier ac breaker.


...................................................................................................................................................................................................

13 Connect the two rectifier ac breaker cables.


...................................................................................................................................................................................................

14 Tighten the two screws on the back of rectifier ac breaker which maintain the two rectifier
ac breaker cables.
...................................................................................................................................................................................................

15 Insert gently the ac distribution module in the 9311 Macro V1 OD.


...................................................................................................................................................................................................

16 Tighten the six screws on the front of ac distribution module.


...................................................................................................................................................................................................

17 Power up the 9311 Macro V1 OD. Refer to the “Powering up a 9311 Macro V1 OD with
d4U” (p. 8-2) procedure.
...................................................................................................................................................................................................

18 Close the doors of the 9311 Macro V1 OD.


E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
10-104 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the DC Breaker Panel

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing the DC Breaker Panel


Purpose
Carry out the following procedure to replace the DC breaker panel.
Note: This model of the DC breaker panel is new to the Macro V1 Node B Outdoor
solution, for use with the configuration with 9926 d4U in the digital shelf.
The DC Breaker Panel is used for the RRH and DBS 4U for the lower RUC.

Intervention time
15 minutes

Tools required
Screwdrivers

Figure 10-44 Location of the DC Breaker Panel in the cabinet

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-105
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the DC Breaker Panel
Replacing the power system equipment
....................................................................................................................................................................................................................................
Figure 10-45 DC Breaker Panel - detailed view

Procedure
...................................................................................................................................................................................................
PRELIMINARY

1 Open the door of the cabinet.


...................................................................................................................................................................................................

2 Switch OFF the DC breakers on the DC breaker panel.

....................................................................................................................................................................................................................................
10-106 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the DC Breaker Panel

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

3 Switch OFF the RF breaker on the DC distribution module.


...................................................................................................................................................................................................

4 Disconnect the cables from the DC breaker front panel and mark them.
...................................................................................................................................................................................................

5 Remove the RF ICO front plate (loosen screws) to access to the RF ICO busbar.
...................................................................................................................................................................................................

6 Disconnect the DC0V and -48V RF0 from the RF ICO busbar.
...................................................................................................................................................................................................

7 Remove the four screws securing the DC breaker panel in place.


...................................................................................................................................................................................................

8 Remove the DC breaker panel.


...................................................................................................................................................................................................

9 Insert the new DC breaker panel.


...................................................................................................................................................................................................

10 Tighten the screws securing the breaker panel in place.


...................................................................................................................................................................................................

11 Re-connect the DC0V and -48V RF0 to the RF ICO busbar.


Note : The -48V connection of the DC breaker panel goes behind the module, coming
from the Interco bus bar.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-107
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the DC Breaker Panel
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

12 Replace the RF ICO front plate (tighten screws).


...................................................................................................................................................................................................

13 Re-connect the cables to the DC breaker front panel.


...................................................................................................................................................................................................

14 Switch ON the RF breaker on the DC distribution module.


...................................................................................................................................................................................................

15 Turn ON the DC breakers on the DC breaker panel.


...................................................................................................................................................................................................

16 Close the door of the cabinet.


E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
10-108 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the batteries of the 9311 Macro V1 OD

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................

Replacing the batteries of the 9311 Macro V1 OD


Purpose
Carry out the following procedure to replace the batteries.

Intervention time
20 minutes

Tools required
Screwdriver

DANGER
Electric-shock hazard
Personnel safety rules: the personnel performing this check must wear rubber gloves and
must be isolated from the ground.
The BTS remains supplied with the mains power supply.
There is a risk of sparks during the test.

Procedure
...................................................................................................................................................................................................

1 Open the doors of the 9311 Macro V1 OD.


...................................................................................................................................................................................................

2 Put the Battery circuit breaker on the DC distribution module in OFF position.
...................................................................................................................................................................................................

3 Locate the batteries in the cabinet.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-109
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the batteries of the 9311 Macro V1 OD
Replacing the power system equipment
....................................................................................................................................................................................................................................

Figure 10-46 Location of the batteries in the 9311 Macro V1 OD

...................................................................................................................................................................................................

4 Loosen the four screws retaining the plastic cover in front of the batteries and remove it.
...................................................................................................................................................................................................

5 Locate the terminal block on the right-hand side of the batteries.


...................................................................................................................................................................................................

6 Loosen the two screws retaining the plastic cover in front of the terminal block and
remove it.
...................................................................................................................................................................................................

7 Remove the black cable between:


• the terminal block (connector on the top left-hand side)
• the right-most battery (bottom connector)
...................................................................................................................................................................................................

8 Remove the blue cable between:


• the terminal block (connector on the bottom right-hand side)
• the left-most battery (top connector)
...................................................................................................................................................................................................
PRELIMINARY

9 Remove the thermal probe connected on the right-most battery (top connector).
...................................................................................................................................................................................................

10 Remove the three cables between the four batteries.

....................................................................................................................................................................................................................................
10-110 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the batteries of the 9311 Macro V1 OD

PRELIMINARY
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

11 Unscrew the two wing nuts retaining the battery support and the two metal rods and
remove them.
...................................................................................................................................................................................................

12 Remove all the batteries, one by one.


...................................................................................................................................................................................................

13 Remove all the white separation piece.


...................................................................................................................................................................................................

14 Replace the four batteries and the three separation pieces in the cabinet.
...................................................................................................................................................................................................

15 Put in place the battery support and the two metal rods and secure them by tightening the
two wing nuts.
...................................................................................................................................................................................................

16 Reconnect the thermal probe on the top connector of the right-most battery.
...................................................................................................................................................................................................

17 Reconnect the three cables between the four batteries.


...................................................................................................................................................................................................

18 Reconnect the blue cable between:


• the terminal block (connector on the bottom right-hand side)
• the left-most battery (top connector)
...................................................................................................................................................................................................

19 Reconnect the black cable between:


• the terminal block (connector on the top left-hand side)
• the right-most battery (bottom connector)
...................................................................................................................................................................................................

20 Replace the plastic cover in front of the terminal block.


...................................................................................................................................................................................................

21 Replace the plastic cover in front of the batteries.


...................................................................................................................................................................................................
PRELIMINARY

22 Put the Battery circuit breaker on the DC distribution module in ON position.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-111
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the batteries of the 9311 Macro V1 OD
Replacing the power system equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

23 Close the doors of the 9311 Macro V1 OD.


E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
10-112 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Overview

PRELIMINARY
Replacing the optional equipment
....................................................................................................................................................................................................................................

Replacing the optional equipment

Overview
Purpose
This section presents the other replacement procedures of modules which are not
contained in the digital shelf and the RF block.

Contents

Replacing the Manufacturing Commissioning and Alarm (MCA) module of the 10-114
9311 Macro V1 OD
Replacing the alarm protection module 10-118
Replacing the Pulse Code Modulation (PCM) protection module of the 9311 10-121
Macro V1 OD
9311 Macro V1 OD with d4U: Replacing the double TMA module 10-123
9311 Macro V1 OD with d4U: Replacing the light TMA/AISG TMA module 10-128
Replacing the Interconnection Module of the 9311 Macro V1 OD with d4U 10-134
Node B
Replacing the anti-sliding strips of 9311 Macro V1 OD cable cover 10-137
Replacing the DC Surge Protection Box, if used 10-142

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-113
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Manufacturing Commissioning and Alarm
Replacing the optional equipment (MCA) module of the 9311 Macro V1 OD
....................................................................................................................................................................................................................................

Replacing the Manufacturing Commissioning and Alarm (MCA)


module of the 9311 Macro V1 OD
Purpose
Carry out the following procedure to replace the MCA module of the 9311 Macro V1 OD.
The MCA module is hot-swappable, therefore no power-down is required.

Intervention time
Ten minutes

Tools required
Flat and Phillips screwdrivers

Figure 10-47 Front view of the MCA module in the 9311 Macro V1 OD

CAUTION
Service Interruption
The disconnection of the PCM cable is going to cause a service interruption of the 9311
Macro V1 OD.

Procedure
...................................................................................................................................................................................................
PRELIMINARY

1 Open the door(s).

....................................................................................................................................................................................................................................
10-114 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Manufacturing Commissioning and Alarm

PRELIMINARY
Replacing the optional equipment (MCA) module of the 9311 Macro V1 OD
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

2 Two cases can occur :


1. The CCM module is not faulty and does not need to be replaced, then go to step three.
2. The CCM module does not need to be replaced - proceed directly to step 14.
...................................................................................................................................................................................................

3 Prepare the spare pre-programmed MCA to replace the faulty one.


...................................................................................................................................................................................................

4 Locate the MCA module.

Figure 10-48 Location of the MCA module

...................................................................................................................................................................................................

5 Disconnect the three cables connected on the MCA front view.


...................................................................................................................................................................................................

6 Unplug the MCA module.


...................................................................................................................................................................................................
PRELIMINARY

7 Replace the new MCA module.


Note: If the left side cable is referred as NTSA7006, the cable adaptor furnished with
the kit must be installed between the cable and the module. If the left side cable is
referred as NTSA7030 the cable must be connected directly to the MCA module.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-115
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Manufacturing Commissioning and Alarm
Replacing the optional equipment (MCA) module of the 9311 Macro V1 OD
....................................................................................................................................................................................................................................

Figure 10-49 MCA of 9311 Macro V1 OD with/without adaptor

...................................................................................................................................................................................................
PRELIMINARY

8 Connect the three cables on the front of the MCA.


...................................................................................................................................................................................................

9 The CCM should be able to detect the new MCA and automatically load the I & C data
stored on the previous MCA.

....................................................................................................................................................................................................................................
10-116 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Manufacturing Commissioning and Alarm

PRELIMINARY
Replacing the optional equipment (MCA) module of the 9311 Macro V1 OD
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

10 If the message is: MCA update forbidden.


Call the next level of support.
...................................................................................................................................................................................................

11 Close the door(s).


...................................................................................................................................................................................................

12 Exit the procedure.


E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-117
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the alarm protection module
Replacing the optional equipment
....................................................................................................................................................................................................................................

Replacing the alarm protection module


Purpose
Perform the following procedure to replace the alarm protection module.

Intervention time
Ten minutes

Tools required
Screwdriver
Wrench for hexagonal head nut (M6 nut)
PRELIMINARY

....................................................................................................................................................................................................................................
10-118 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the alarm protection module

PRELIMINARY
Replacing the optional equipment
....................................................................................................................................................................................................................................

Figure 10-50 Alarm protection module front panel

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
PRELIMINARY

general ESD instructions.


Important! Notify the OMC administrator of the alarm protection module
replacement.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-119
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the alarm protection module
Replacing the optional equipment
....................................................................................................................................................................................................................................
Procedure
...................................................................................................................................................................................................

1 Open the Node B door.


...................................................................................................................................................................................................

2 Locate the alarm protection module in the cabinet.


...................................................................................................................................................................................................

3 Remove the cables from the alarm protection module.


...................................................................................................................................................................................................

4 Remove the two connectors from the bulkhead and undo the wiring.
...................................................................................................................................................................................................

5 Loosen the two front panel screws.


...................................................................................................................................................................................................

6 Remove the defective alarm protection module.


...................................................................................................................................................................................................

7 Insert the new alarm protection module into the cabinet.


...................................................................................................................................................................................................

8 Tighten the two front panel screws.


...................................................................................................................................................................................................

9 Reconnect the cables to the alarm protection module.


...................................................................................................................................................................................................

10 Reconnect the two connectors to the bulkhead and redo the wiring.
...................................................................................................................................................................................................

11 Check with the OMC administrator that all alarms are OK.
...................................................................................................................................................................................................

12 Close the Node B doors.


E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
10-120 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Pulse Code Modulation (PCM) protection

PRELIMINARY
Replacing the optional equipment module of the 9311 Macro V1 OD
....................................................................................................................................................................................................................................

Replacing the Pulse Code Modulation (PCM) protection module


of the 9311 Macro V1 OD
Purpose
Carry out the following procedure to replace the PCM Lightning Protection Module.

Intervention time
15 minutes

Tools required
• Screwdrivers
• Wrenches for hexagonal head (M6 nut)

Figure 10-51 Front view of the PCM protection module

Procedure
...................................................................................................................................................................................................

1 Open the doors of the 9311 Macro V1 OD.


...................................................................................................................................................................................................

2 CAUTION
Service interruption
This procedure requires a service interruption of the 9311 Macro V1 OD.
PRELIMINARY

Locate the PCM protection module in the cabinet.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-121
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Pulse Code Modulation (PCM) protection
Replacing the optional equipment module of the 9311 Macro V1 OD
....................................................................................................................................................................................................................................

Figure 10-52 Location of the PCM protection module into the 9311 Macro V1 OD

...................................................................................................................................................................................................

3 Remove the cables in front of the PCM protection module.


...................................................................................................................................................................................................

4 Mark then disconnect the PCM cables.


...................................................................................................................................................................................................

5 Loosen the two front panel screws.


...................................................................................................................................................................................................

6 Remove the defective PCM protection module.


...................................................................................................................................................................................................

7 Insert the new PCM protection module into the cabinet.


...................................................................................................................................................................................................

8 Tighten the two front panel screws.


...................................................................................................................................................................................................

9 Reconnect the cables.


...................................................................................................................................................................................................
PRELIMINARY

10 Close the doors of the 9311 Macro V1 OD.


E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
10-122 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the double TMA

PRELIMINARY
Replacing the optional equipment module
....................................................................................................................................................................................................................................

9311 Macro V1 OD with d4U: Replacing the double TMA


module
Purpose
The double TMA module kit includes the following items:
• One double TMA module
• One support plate to fix the TMA on a pole
Carry out the following procedure to replace the TMA module.

Intervention time
15 minutes

Tools required
• 7/16 torque wrench
• 13-mm open wrench
• Flat screwdriver
• Phillips screwdriver
Note: Tightening torques are specified within the procedure.
The following figure shows the double TMA set-up diagram.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-123
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the double TMA
Replacing the optional equipment module
....................................................................................................................................................................................................................................

Figure 10-53 TMA module set-up diagram


PRELIMINARY

....................................................................................................................................................................................................................................
10-124 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the double TMA

PRELIMINARY
Replacing the optional equipment module
....................................................................................................................................................................................................................................
CAUTION
RF hazard
RF exposure in excess of applicable limits can result in serious personal injury.
Observe the following:
• Turn off and lockout the transmit power before working on the antenna system.
• If the transmitters must be tested with the antennas connected, adhere to appropriate
antenna safety distances.
• Do not use auxiliary antennas.
• Consult with the Antenna exposure statements before beginning work.

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.

Procedure
...................................................................................................................................................................................................

1 Locate the faulty TMA :


• You may ask the OMC administrator, who may identify the source of the problem.
• You may connect to the TIL, and deduce the faulty TMA by the cells in error
...................................................................................................................................................................................................

2 If the Node B is operational and connected to the OMC, ask the OMC administrator to
lock the sector associated with the faulty TMA (by Set Administrative State). For more
information, please refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................
PRELIMINARY

3 Locate the four RF ports:


• MAIN BTS
• MAIN ANT

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-125
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the double TMA
Replacing the optional equipment module
....................................................................................................................................................................................................................................
• DIV BTS
• DIV ANT
...................................................................................................................................................................................................

4 Disconnect the four RF cables from the TMA using the torque wrench.
...................................................................................................................................................................................................

5 Locate the ground port at the bottom of the TMA.


...................................................................................................................................................................................................

6 Disconnect the ground cable by loosening the nut from the TMA using the 13-mm
wrench.
...................................................................................................................................................................................................

7 On the support plate, untighten the four screws on the support side by using the Phillips
screwdriver.
...................................................................................................................................................................................................

8 Untighten the four nuts which firmly anchor the TMA to the support plate, and remove
the faulty TMA module.
...................................................................................................................................................................................................

9 Append the new TMA module and fix it to the support side with all four screws.
...................................................................................................................................................................................................

10 Tighten the four nuts to firmly anchor the TMA to the support plate.
...................................................................................................................................................................................................

11 Locate the ground port at the bottom of the TMA.


...................................................................................................................................................................................................

12 Remove the screw, the two flat washers, and the split washer. Take care not to lose items
during the removal.
...................................................................................................................................................................................................

13 Perform the installation of an eyelet terminal to the ground cable.


...................................................................................................................................................................................................

14 Connect the ground cable to the TMA by assembling the following components in the
following order:
PRELIMINARY

• Flat washer
• Eyelet terminal
• Flat washer

....................................................................................................................................................................................................................................
10-126 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the double TMA

PRELIMINARY
Replacing the optional equipment module
....................................................................................................................................................................................................................................
• Split washer
• Hexagonal nut
...................................................................................................................................................................................................

15 Tighten the ground cable using the 13-mm wrench. Check that the other end of the cable
is connected to an efficient ground point.
...................................................................................................................................................................................................

16 Remove the protection caps on the four connectors.


...................................................................................................................................................................................................

17 Reconnect the four RF cables to the TMA.


...................................................................................................................................................................................................

18 Tighten the RF connectors to the TMA using the torque wrench, setting the torque to the
maximum value recommended by the supplier of the 7/16 male connector.
Note: Tighten with 25 N.m in case there is no detailed instruction available from the
connector manufacturer.
Result: The TMA is installed with all connections completed.
...................................................................................................................................................................................................

19 Ask the OMC administrator to unlock the sector associated with the faulty TMA and
previously locked on step 2.
...................................................................................................................................................................................................

20 Check with the OMC administrator that the Node B is operational.


E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-127
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the light TMA/AISG
Replacing the optional equipment TMA module
....................................................................................................................................................................................................................................

9311 Macro V1 OD with d4U: Replacing the light TMA/AISG


TMA module
Purpose
The light TMA kit includes the following items:
• One light TMA module
• Two standard hose clamps, two standard mounting brackets, and four nuts to fasten
the brackets to the light TMA
• Two mounting brackets for specific antenna mounting and four nuts to fasten the
brackets to the light TMA
• Test protocol from factory
For more information about the light TMA and AISG TMA, please refer to Alcatel-Lucent
9311 Macro Node B Outdoor Technical Description, 3MN-00475-0010-DEZZA.
Carry out the following procedure to replace the TMA module.

Intervention time
15 minutes

Tools required
• 7/16 torque wrench
• 13-mm open wrench
• 17-mm torque wrench
• Cutting pliers
Note: Tightening torques are specified within the procedure.
The following figure shows the light TMA set-up diagram.
PRELIMINARY

....................................................................................................................................................................................................................................
10-128 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the light TMA/AISG

PRELIMINARY
Replacing the optional equipment TMA module
....................................................................................................................................................................................................................................

Figure 10-54 Light TMA module set-up diagram

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-129
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the light TMA/AISG
Replacing the optional equipment TMA module
....................................................................................................................................................................................................................................
WARNING
Electric-shock hazard
Some parts of all electrical installations are energized. Failure to follow safe work
practices and the safety warnings may lead to bodily injury and property damage. For
this reason, only trained and qualified personnel (electrical workers as defined in IEC
60215 or EN 60215 + A1 or in the National Electrical Code or in ANSI/NFPA No.10)
may install or service the installation.
Important! Only authorized personnel, with adequate technical training and expertise
with radio base systems will be permitted to operate on the various units. Opening of
enclosed units is not permitted.

CAUTION
RF hazard
RF exposure in excess of applicable limits can result in serious personal injury.
Observe the following:
• Turn off and lockout the transmit power before working on the antenna system.
• If the transmitters must be tested with the antennas connected, adhere to appropriate
antenna safety distances.
• Do not use auxiliary antennas.
• Consult with the Antenna exposure statements before beginning work.

NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
You must notify the OMC administrator.

NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD). Hold circuit
packs only at the edges or on the insertion and removal facilities. Always observe the
general ESD instructions.
PRELIMINARY

Important! Observe the general safety precaution against injury and equipment
damage outlined in the regional installation safety manual at all times.

....................................................................................................................................................................................................................................
10-130 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the light TMA/AISG

PRELIMINARY
Replacing the optional equipment TMA module
....................................................................................................................................................................................................................................
Appropriate precautions must be taken to guarantee the safety of staff and equipment.
All operations to perform the connection of the TMA module to the Node B must be
done according to the safety instructions; please contact your Node B supplier for
valid instruction.

Procedure
...................................................................................................................................................................................................

1 Locate the faulty TMA :


• You may ask the OMC administrator, who may identify the source of the problem.
• You may connect to the TIL, and deduce the faulty TMA by the cells in error
...................................................................................................................................................................................................

2 If the Node B is operational and connected to the OMC, ask the OMC administrator to
lock the sector associated with the faulty TMA (by Set Administrative State). For more
information, please refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, 9YZ-04088-0014-PCZZA.
...................................................................................................................................................................................................

3 Locate the four RF ports:


• NODEB 0
• NODEB 1
• ANT 0
• ANT 1
...................................................................................................................................................................................................

4 Disconnect the ground cable by loosening the nut from the TMA using the 13-mm open
wrench.
...................................................................................................................................................................................................

5 Disconnect the four jumper cables from the TMA RF connectors using the 7/16 torque
wrench.
Note: For AISG TMA, disconnect the AISG cable using the 7/16 torque wrench.
...................................................................................................................................................................................................

6 Open the hose clamps by unscrewing the bolt.


...................................................................................................................................................................................................
PRELIMINARY

7 Extract the faulty TMA with both clips mounted.


...................................................................................................................................................................................................

8 Take the new TMA and the two clips.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-131
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the light TMA/AISG
Replacing the optional equipment TMA module
....................................................................................................................................................................................................................................

Figure 10-55 Light TMA module

...................................................................................................................................................................................................

9 Position the clips on the TMA.


...................................................................................................................................................................................................

10 Torque tighten the Nyloc nuts to 3.5 N.m.


Result: The TMA is mounted with both clips.
...................................................................................................................................................................................................

11 Open the hose clamps by unscrewing the bolt.


...................................................................................................................................................................................................

12 Move the steel band into the openings of the TMA mounting equipment.
...................................................................................................................................................................................................

13 Tighten the hose clamp screws carefully. Do not over tighten them.
...................................................................................................................................................................................................
PRELIMINARY

14 Connect the four jumper cables to the TMA RF connectors using the 7/16 torque wrench.

....................................................................................................................................................................................................................................
10-132 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures 9311 Macro V1 OD with d4U: Replacing the light TMA/AISG

PRELIMINARY
Replacing the optional equipment TMA module
....................................................................................................................................................................................................................................
Note: Tightening torques must be the following:
• 25-30 N.m (35-40 Ibf ft) for 7/16 connectors
• 6 N.m (8 Ibf ft) for N-type connectors
...................................................................................................................................................................................................

15 For AISG TMA, reconnect the AISG cable using the 7/16 torque wrench. Tightening
torque is 25-30 N.m (35-40 Ibf ft).
Result: The TMA is installed when all connections are completed.
...................................................................................................................................................................................................

16 Reconnect the ground cable using the 13-mm open wrench. Tightening torque is 5 N.m
(3.7 Ibf ft).
...................................................................................................................................................................................................

17 Ask the OMC administrator to unlock the sector associated with the faulty TMA and
previously locked on step 2.
...................................................................................................................................................................................................

18 Check with the OMC administrator that the Node B is operational.


E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-133
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Interconnection Module of the 9311 Macro V1
Replacing the optional equipment OD with d4U Node B
....................................................................................................................................................................................................................................

Replacing the Interconnection Module of the 9311 Macro V1


OD with d4U Node B
Purpose
Carry out the following procedure to replace the Interconnection module of the 9311
Macro V1 OD with d4U Node B.

Intervention time
40 minutes

Tools required
• Flat and Phillips screwdrivers
• 7mm open wrench

Figure 10-56 Front view of the Interconnection module in the 9311 Macro V1 OD

Procedure
...................................................................................................................................................................................................
PRELIMINARY

1 Open the doors of the 9311 Macro V1 OD.


...................................................................................................................................................................................................

2 Locate the faulty Interconnection module.

....................................................................................................................................................................................................................................
10-134 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the Interconnection Module of the 9311 Macro V1

PRELIMINARY
Replacing the optional equipment OD with d4U Node B
....................................................................................................................................................................................................................................

Figure 10-57 Location of the Interconnection module in the 9311 Macro V1 OD

...................................................................................................................................................................................................

3 CAUTION
Service Interruption
Disconnecting the cables from the Interconnection module will cause a service
interruption of the 9311 Macro V1 OD.

“Powering down a 9311 Macro V1 OD with d4U” (p. 8-10)


...................................................................................................................................................................................................

4 Mark then disconnect all cables from the TRDU connectors.


...................................................................................................................................................................................................

5 Loosen the eight front panel screws.


...................................................................................................................................................................................................

6 Remove the defective Interconnection module.


...................................................................................................................................................................................................

7 Mark then disconnect the three cables (-48 V, 0V, GND) from the DC power bus bar, and
the two cables (-48V, 0V) to the DC breaker, by unscrewing the nuts.
PRELIMINARY

...................................................................................................................................................................................................

8 Change the Interconnection module by the new one and check the fuses are in place.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-135
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the Interconnection Module of the 9311 Macro V1
Replacing the optional equipment OD with d4U Node B
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

9 Reconnect the three cables to the DC power bus bar screwing the nuts and following the
marks.
...................................................................................................................................................................................................

10 Insert the new Interconnection module.


...................................................................................................................................................................................................

11 Tighten the eight front panel screws.


...................................................................................................................................................................................................

12 Reconnect all cables in front of the module following the marks.


...................................................................................................................................................................................................

13 Reconnect all cables to D-sub and RJ45 front pannel connectors following the marks.
...................................................................................................................................................................................................

14 “Powering up a 9311 Macro V1 OD with d4U” (p. 8-2)


...................................................................................................................................................................................................

15 Close the doors of the 9311 Macro V1 OD.


E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
10-136 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the anti-sliding strips of 9311 Macro V1 OD cable

PRELIMINARY
Replacing the optional equipment cover
....................................................................................................................................................................................................................................

Replacing the anti-sliding strips of 9311 Macro V1 OD cable


cover
Purpose
Anti-sliding strips are stuck onto the cable cover of the 9311 Macro V1 OD. Nevertheless,
it has been found that after a while, when the cabinet is installed in bad weather
conditions, they might found unstuck, no more offering the safety guarantee they are
designed for and by the way presenting a bad visual aspect.

Detection process

Perform the following procedure to replace those anti-sliding strips.

Intervention time
One hour

Tools required
• Rework kit (PEC code: NTUM99XA) consisting in 2 self-adhesive strips
PRELIMINARY

• Pair of rubber glove for hands protection purpose


• Cloth used to clean-up the cable cover from glue residue
• Solvent ULTRASOLV (Kent industrial ref: ULF 34833415) or equivalent to remove
glue residue
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-137
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the anti-sliding strips of 9311 Macro V1 OD cable
Replacing the optional equipment cover
....................................................................................................................................................................................................................................
DANGER
Electric-shock hazard
The 9311 Macro V1 OD remains supplied with the mains power supply.

DANGER
Staff Safety
Any operation on an outside site is forbidden in case of thunder storm, heavy rain or high
wind.
Wear gloves during the application of the present procedure.
Respect solvent safety datasheet before using it on site.
Conform to general safety precautions against personnel injury stated in the local
installer's regulations.
Conform to all rules related to the premises and country specific.

CAUTION
The 9311 Macro V1 OD remains supplied with the mains power
supply.
Wear the antistatic bracelet when performing the maintenance procedure described
below.

CAUTION
Equipment Safety
Conform to general safety precautions against equipment damage stated in the local
regulations.
Be careful not to damage cabinet external frames which are responsible for the overall
appearance of the cabinet, especially make sure of the type of solvent used.
Prefer good weather conditions to perform the cable cover rework operation.
PRELIMINARY

....................................................................................................................................................................................................................................
10-138 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the anti-sliding strips of 9311 Macro V1 OD cable

PRELIMINARY
Replacing the optional equipment cover
....................................................................................................................................................................................................................................

Figure 10-58 Wear gloves during the clean-up operation

Procedure
...................................................................................................................................................................................................

1 Remove both strips.

PRELIMINARY

...................................................................................................................................................................................................

2 Using cloth and solvent, remove all glue residue from old strips so to obtain a clean
surface.
....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-139
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the anti-sliding strips of 9311 Macro V1 OD cable
Replacing the optional equipment cover
....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

3 Wait until the surface is dry. Start applying the new self-adhesive strip at one end (do not
remove the whole protective paper).
PRELIMINARY

...................................................................................................................................................................................................

4 Align the whole strip along the cable cover and then remove the protective paper. Press
on the strip to ensure it is perfectly stuck. Repeat steps 3 and 4 for the second strip.

....................................................................................................................................................................................................................................
10-140 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the anti-sliding strips of 9311 Macro V1 OD cable

PRELIMINARY
Replacing the optional equipment cover
....................................................................................................................................................................................................................................

...................................................................................................................................................................................................

5 Clean-up the site before leaving. The following figure shows the final result.

PRELIMINARY

E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-141
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the DC Surge Protection Box, if used
Replacing the optional equipment
....................................................................................................................................................................................................................................

Replacing the DC Surge Protection Box, if used


Purpose
Carry out the following procedure to replace the DC surge protection box, also referred to
as the “DC box”.

Intervention time
15 minutes

Tools required
Screwdrivers

Figure 10-59 DC Surge Protection Box - detailed view


PRELIMINARY

....................................................................................................................................................................................................................................
10-142 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the DC Surge Protection Box, if used

PRELIMINARY
Replacing the optional equipment
....................................................................................................................................................................................................................................
DC Box, in configuration with d4U Node B

Figure 10-60 DC Box connections, with the d4U Node B and the left bulkhead

Note: The DC box is located outside the cabinet, mounted normally on a mast or wall.

CAUTION
Service Interruption
Shutdown of the RRH is going to cause a service interruption of the 9311 Macro V1 OD.

CAUTION
Service Interruption
The RRH and associated cells must be locked before attempting to change the DC box.

Procedure
PRELIMINARY

...................................................................................................................................................................................................

1 Open the door of the cabinet.

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-143
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the DC Surge Protection Box, if used
Replacing the optional equipment
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................

2 Switch OFF the three DC breakers in the DC box.


...................................................................................................................................................................................................

3 Switch OFF the RRH breaker on the additional DC breaker panel.


...................................................................................................................................................................................................

4 Disconnect the following cables of the DC box:


• the DC PWR cable from the cabinet bulkhead
• the three DC PWR cables to the RRH
• the main ground cable of the DC box
...................................................................................................................................................................................................

5 Remove the screws securing the DC surge protection box in place.


...................................................................................................................................................................................................

6 Remove the DC box.


...................................................................................................................................................................................................

7 Insert the new DC box in place.


...................................................................................................................................................................................................

8 Tighten the screws securing the DC box in place.


...................................................................................................................................................................................................

9 Re-connect the cables to the new DC box:


• the DC PWR cable from the cabinet bulkhead
• the three DC PWR cables to the RRH
• the main ground cable of the DC box
...................................................................................................................................................................................................

10 Switch ON the RRH breaker on the additional DC breaker panel.


...................................................................................................................................................................................................

11 Switch on the three DC breakers in the DC box, one by one.


...................................................................................................................................................................................................

12 Close the door of the cabinet.


PRELIMINARY

E...................................................................................................................................................................................................
N D O F S T E P S

....................................................................................................................................................................................................................................
10-144 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Corrective maintenance procedures Replacing the DC Surge Protection Box, if used

PRELIMINARY
....................................................................................................................................................................................................................................

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary 10-145
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Corrective maintenance procedures Replacing the DC Surge Protection Box, if used

....................................................................................................................................................................................................................................
PRELIMINARY

....................................................................................................................................................................................................................................
10-146 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
Appendix A: 9326 d2U
Commissioning,
Decommissioning

Overview
Purpose
This appendix provides instructions to power up and power down the 9326 d2U.

Contents

Powering up a 9926 d4U Node B A-2


Powering down the 9926 d4U Node B A-3

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary A-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9326 d2U Commissioning, Decommissioning Powering up a 9926 d4U Node B

....................................................................................................................................................................................................................................

Powering up a 9926 d4U Node B


Purpose
Perform the following procedure to power up a 9926 d4U Node B.

Initial check
On the RUC module, check that the power switch is in the "O" position.

Procedure
...................................................................................................................................................................................................

1 At the operator DC power supply, put the site circuit breaker of the 9926 d4U Node B in
the "ON" position.
...................................................................................................................................................................................................

2 On the RUC module, put the power switch in the "1" position.
...................................................................................................................................................................................................

3 Check that the fans are starting up.


...................................................................................................................................................................................................

4 On the eCCM-U or xCCM-U and on each eCEM-U or xCEM-U, check that:


• The green LED is ON.
• The red LED is OFF.

E...................................................................................................................................................................................................
N D O F S T E P S
PRELIMINARY

....................................................................................................................................................................................................................................
A-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
9326 d2U Commissioning, Decommissioning Powering down the 9926 d4U Node B

PRELIMINARY
....................................................................................................................................................................................................................................

Powering down the 9926 d4U Node B


Purpose
Perform the following procedure to power down the 9926 d4U Node B.

Procedure
...................................................................................................................................................................................................

1 Preliminary operation: make sure that the "BTSEquipment" object is "locked".


...................................................................................................................................................................................................

2 On the RUC V5 module, put the power switch "1/0" (ON/OFF) to the ""0" (OFF)"
position.
...................................................................................................................................................................................................

3 Check that all LEDs on the eCCM-U or xCCM-U and on each eCEM-U or xCEM-U are
OFF.
...................................................................................................................................................................................................

4 Check that the fans are stopping down.


...................................................................................................................................................................................................

5 At the operator DC power supply, put the site circuit breaker of the 9926 d4U Node B in
the "OFF" position.
E...................................................................................................................................................................................................
N D O F S T E P S

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary A-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY 9326 d2U Commissioning, Decommissioning Powering down the 9926 d4U Node B

....................................................................................................................................................................................................................................
PRELIMINARY

....................................................................................................................................................................................................................................
A-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
PRELIMINARY
Appendix B: Product
conformance statements

Overview
Purpose
This appendix provides the product conformance statements for a Macro V1 Node B
Outdoor with 9926 d4U in the digital shelf.

Contents

European regulatory requirement compliance B-2


Compliances for other regions/countries B-4
Operational conditions B-5
Cable specifications B-6
Product labelling B-7

PRELIMINARY

...................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary B-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Product conformance statements European regulatory requirement compliance

....................................................................................................................................................................................................................................

European regulatory requirement compliance


Overview
As a radio product, the Node B falls under the requirement of the Radio and Telecom
Terminal Equipment (RTTE) European directive 1999/5/EEC. The RTTE directive covers
essential requirements in the field of:
• Protection of the Health and Safety of the user and any other person, including the
objectives with respect to safety requirements contained in the Low Voltage directive
(2006/95/EC)
• The protection requirements with respect to EMC contained in Directive
2004/108/EC.
The equipment generates, uses, and can radiate radio frequency energy. If not installed
and used in accordance with the instruction manual, the equipment may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference.
The EMC requirements have been selected to ensure an adequate level of
compatibility for apparatus at residential, commercial, and light industrial
environments. The levels however, do not cover extreme cases which may occur in
any location but with a low probability of occurrence. In particular, it may not cover
those cases where a potential source of interference which is producing individually
repeated transient phenomena, or continuous phenomena, is permanently present, for
example a radar or broadcast site in the near vicinity. In such a case it may be
necessary to either limit the source of interference, or use special protection applied,
to the interfered part, or both.
Note: For operation or maintenance inside Alcatel-Lucent systems, the antistatic wrist
shall always be used to maintain the integrity of the product.
• Effective use of the Radio spectrum allocated to terrestrial/space radio communication
and orbital resources so as to avoid harmful interference. The routes and standards
used to demonstrate compliance with there essential requirements are outlined in the
following paragraphs.
– Node B EMC
Compliance with the essential requirements of EMC has been demonstrated using
EN301489-1 & -23 standard.
– Node B radio compliance
Compliance with the essential requirements of effective use of the radio spectrum
PRELIMINARY

has been demonstrated using EN301908-1 & -3 standard.


– Node B safety
Compliance with the essential requirements of Safety has been demonstrated
using EN 60950-1 standard.
– Node B health protection
....................................................................................................................................................................................................................................
B-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Product conformance statements European regulatory requirement compliance

PRELIMINARY
....................................................................................................................................................................................................................................
Compliance with the essential requirement of health requirement has been
demonstrated using EN50385.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary B-3
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Product conformance statements Compliances for other regions/countries

....................................................................................................................................................................................................................................

Compliances for other regions/countries


Overview
For countries outside Europe and the Americas, the requirements of European countries
usually apply.
It is not possible to list all the applicable approvals/compliances as they will be dependent
on the markets and products considered.
Note: For more information, please contact your local Alcatel-Lucent representative.
PRELIMINARY

....................................................................................................................................................................................................................................
B-4 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Product conformance statements Operational conditions

PRELIMINARY
....................................................................................................................................................................................................................................

Operational conditions
Overview
The aforementioned standards compliance of the products are based on the following
operating conditions (called normal operation):
• Doors shall be closed and/or covers shall be in place.
• External cables shall be of the same type as specified by Alcatel-Lucent.
• No modification of any mechanical or electrical characteristics of the product shall be
made.
Any change or modification made to the product without written approval from
Alcatel-Lucent releases Alcatel-Lucent from subsequent responsibility regarding the
standards compliance.

PRELIMINARY

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary B-5
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Product conformance statements Cable specifications

....................................................................................................................................................................................................................................

Cable specifications
Overview
The compliance to the aforementioned standards has been verified using cables as
specified by Alcatel-Lucent. The continuing compliance of the product relies upon use of
the correct cabling scheme as well as use of identical type cables as specified by
Alcatel-Lucent. Refer to the installation guides for details on cable specifications.
PRELIMINARY

....................................................................................................................................................................................................................................
B-6 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Product conformance statements Product labelling

PRELIMINARY
....................................................................................................................................................................................................................................

Product labelling
Overview
The label may be located inside or outside the product, provided that the operation and/or
maintenance personnel have the information when working on the product.

Node B labelling for American Countries


To indicate compliance with the CSA and UL Safety requirements, the 9311 Macro V1
OD bears the following mark in a conspicuous location.

On the regulatory label, compliance to 47 CFR Part 15, 22 or 24, and 68 is stated along
with:
• FCC ID, FCC Registration Number
• Manufacturers name
• Equipment designation
• Nominal voltage operating range and maximum rated current.

Node B labelling for European Countries


To indicate compliance with the European RTTE Directive, the Node B bears the
following information in a conspicuous location:

• Manufacturers name
PRELIMINARY

• Equipment designation
• Nominal voltage operating range and maximum rated current

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary B-7
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Product conformance statements Product labelling

....................................................................................................................................................................................................................................
Labelling for other regions/countries
Labelling for other regions and countries is performed as appropriate and required by the
local regulatory framework.
PRELIMINARY

....................................................................................................................................................................................................................................
B-8 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013
Index

PRELIMINARY
E eCCM-U ............................................................. Small Form-factor Pluggable
See: enhanced Core Controller (SFP)
O Optional Supported Network
Module-U (eCCM-U)
Configurations, 1-5 replace, 10-19
eCEM-U
NodeB dropping 2G BTS, 1-6 .............................................................
See: enhanced Channel
Element Module-U NodeB dropping 3G NodeB, X xCCM-U
(eCEM-U) 1-5 See: extended Core Controller
enhanced Channel Element Module-U (xCCM-U)
NodeB dropping 4G eNodeB,
Module-U (eCEM-U) 1-6 xCEM-U
front view, 10-4 See: extended Channel
.............................................................
Element Module-U
replace, 10-4 P pre-cabled rack (xCEM-U)
enhanced Core Controller replace, 10-31
Module-U (eCCM-U)
.............................................................
eCCM-U-GE front view, 10-10
R replace
replace, 10-10
enhanced Core Controller
extended Channel Element
Module-U (eCCM-U), 10-10
Module-U (xCEM-U)
extended Core Controller
front view, 10-4
Module-U (xCCM-U), 10-10
replace, 10-4
fan rack module, 10-24
extended Core Controller
pre-cabled rack, 10-31
Module-U (xCCM-U)
Small Form-factor Pluggable
replace, 10-10
(SFP), 10-19
xCCM-U-GE front view, 10-10
.............................................................
.............................................................
S Safety statements, 2-1, 2-2
PRELIMINARY

F fan rack module


SFP
front view, 10-24 See: Small Form-factor
replace, 10-24 Pluggable (SFP)

....................................................................................................................................................................................................................................
Alcatel-Lucent 9311 Macro V1 OD Alcatel-Lucent – Proprietary IN-1
3MN-00475-0006-REZZA Use pursuant to applicable agreements
Issue 1.03 June 2013
PRELIMINARY Index

....................................................................................................................................................................................................................................
PRELIMINARY

....................................................................................................................................................................................................................................
IN-2 Alcatel-Lucent – Proprietary Alcatel-Lucent 9311 Macro V1 OD
Use pursuant to applicable agreements 3MN-00475-0006-REZZA
Issue 1.03 June 2013

You might also like