Professional Documents
Culture Documents
Copyright © ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.
1
D 3495
instead of cycling, extract the leather for a minimum of 5 h 10. Precision and Bias
using maximum heat. At the end of the extraction period, 10.1 Interlaboratory Test Data3—An interlaboratory test
remove the flask containing the extraction solvent and drive off was run in 1972 in which each of 7 laboratories tested duplicate
the hexane. When 10 to 20 mL of hexane remain, heat gently specimens from each of 15 different types of leather. All
on a steam bath until the odor of the solvent can no longer be laboratories tested the following leathers: chamois, yellow
detected. Facilitate the removal of the hexane by utilizing a lace, crust sheepskin, crust goatskin, vegetable-strap leather,
vacuum or a gentle stream of filtered (oil- and water-free) air. chrome-retan side leather, vegetable-skirting leather,
After the hexane has been removed, dry the flask containing vegetable-retan side leather, latigo-lace leather, white-lace
the extracted matter in a forced circulating air oven at 100 6 leather, suede sheepskin, horsehide (finished), white-side
2°C, for 2 h, cool to room temperature in a desiccator and leather, chrome-split leather, and silicone-treated military
weigh. Continue drying for successive 2-h periods until con- leather. The components of variance for hexane-soluble matter
stant weight is obtained. When successive weighings vary by expressed as standard deviations were calculated to be:
less than 6 0.005 g, consider the weight constant. Record this
Within2laboratory ~single operator!
weight to the nearest 0.001 g as W3. No more than three component—0.14 percentage points (2)
successive 2-h drying periods shall be allowed. If constant
Between2laboratory component—0.41 percentage points (3)
weight has not been obtained after the third drying, the results
of the second drying period shall be repeated. 10.2 Precision—For the components of variance reported in
9.1, two averages of two observations each of hexane soluble
matter should be considered significantly different at the 95 %
8. Calculation
probability level if the difference equals or exceeds the
8.1 Calculate the percentage of hexane-soluble matter, on a following critical differences:
moisture-free basis, as follows: Within2laboratory ~single operator! precision 0.59 percentage points
(4)
W 3 2 W2
Hexane2soluble matter, % 5 3 100 Between2laboratory precision 1.41 percentage points ~see Note 3!
~100 2 % moisture! (5)
W1 3 100
(1) NOTE 2—The critical differences were calculated using t = 1.960,
which is based on infinite degrees of freedom.
where: NOTE 3—The calculated values of the critical differences should be
W1 = original weight of extracted leather, considered to be a general statement particularly with respect to between-
W2 = weight of extraction flask, and laboratory precision. Before a meaningful statement can be made about
W3 = weight of extraction flask and hexane-soluble matter. two specific laboratories, the amount of statistical bias, if any, between
them must be established, with each comparison being based on recent
data obtained on randomized specimens from one sample of the material
to be tested. The interlaboratory test showed that for certain leathers
9. Report containing more than 18 % hexane-soluble matter the between-laboratory
critical difference could be as high as 3 percentage points.
9.1 Report the hexane-soluble matter in the leather as the 10.3 Bias—No justifiable statement on bias can be made,
average value obtained from the test results to nearest 0.01 %. since the true value of hexane-soluble matter cannot be
9.2 State that the results are calculated on a moisture-free established by an accepted reference method.
basis. 11. Keywords
11.1 extractables; extraction; fat liquor; hexane—soluble
lubricant; lubrication
3
Supporting data have been filed at ASTM Headquarters and may be obtained by
requesting Research Report RR: D-31-1003.
The American Society for Testing and Materials takes no position respecting the validity of any patent rights asserted in connection
with any item mentioned in this standard. Users of this standard are expressly advised that determination of the validity of any such
patent rights, and the risk of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM Headquarters. Your comments will receive careful consideration at a meeting of the responsible
technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your
views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.
Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above address or at
610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website (www.astm.org).