Megger has offices across the U.S. and around the world, with major international hubs in Sweden and the U.K.
twitter.com/meggerusa
Linkedin.com/company/megger
megger.com/us
Contents
Battery Test Equipment............................................................... 2
INSULATION RESIsTANCE TESTING.................................................... 3
HIGH-VOLTAGE INSULATION TESTING............................................... 3
OIL TESTING...................................................................................... 3
Transformer test equipment selection chart....................... 4
TransFormer Testing................................................................... 5
CABLE Diagnostics and FAULT LOCATING.................................... 8
PROTECTIVE RELAY TESTING........................................................... 10
CIRCUIT BREAKER TESTING............................................................. 12
LOW RESISTANCE TESTING............................................................. 15
WATTHOUR METER TESTING........................................................... 16
POWER QUALITY TESTING.............................................................. 16
BITE2/BITE2P BATTERY IMPEDANCE BITE3 BATTERY IMPEDANCE BGFT BATTERY GROUND FAULT
TEST SETS TEST SET TRACER
• Determine condition of lead-acid & NiCad • Determines condition of lead-acid batteries • Locates ground faults up to 399 kohms on
batteries up to 7,000 Ah up to 2,000 Ah in-service DC battery systems
• Fast 3 second measuring time • Measures impedance, inter-cell connection • Tunes out phantom shorts due to capacitance
• Allow on-line & on-board testing resistance, cell voltage, ripple, and DC float • Simplifies tracing by identifying fault
current characteristic magnitudes
• Built in Spectrum Analyzer for detailed ripple
analysis
BGL BATTERY GROUND FAULT BVM BATTERY VOLTAGE MONITOR TORKEL 840/860 BATTERY LOAD
LOCATOR • Automates voltage measurement during UNITS
• Locates ground faults in ungrounded DC capacity tests • Use battery load & provide regulated load to
battery systems • Accuracy & stability for precise data collection meet test parameters
• Battery operated • Expands up to 120 units (optional) • Adjustable alarm & shutdown points to avoid
• Simplifies location by measuring fault excessive discharge
resistance and capacitance • Expand for larger battery banks using TXL870
(optional)
PRIORITY
ACCESS
PROGRAM
• Maximizes
investment in
DELTA4000 with
expert technical
assistance
• Offers engineering
consultation &
DELTA4110 test set is to
be used with an external results analysis
computer (not included). • Expedites repair
services
• Loaner unit
DELTA4310 test set within 1-2 days
comes with an onboard and annual onsite
computer. training
MTO300 AUTOMATED SIX-WINDING FRAX99/101/150 SWEEP FREQUENCY RESPONSE ANALYZERS IDAX300/350 INSULATION
TRANSFORMER OHMMETER • Fulfill all international standards for sweep frequency response analysis DIAGNOSTIC ANALYZERS
• Uses simultaneous winding magnetization for • Highest dynamic range and frequency • Provide fast, accurate moisture and oil
fast, accurate DC winding resistance of high- • Wide range of import/export data assessments in transformers
inductive loads • Includes Bluetooth communications and optional battery operation • Multifunction measurement of tan delta,
• Automated eight-terminal/six-winding capacitance, dielectric frequency response
measurement capability (DFR/FDS)
• Uses external PC (or other Megger products • DC insulation and excitation current
with on-board computer such as the
DELTA3000, DELTA4310, TTR330, and FRAX150)
MTO330 AUTOMATED SIX-WINDING MTO210 TRANSFORMER CDAX 605 capacitance and VAX020 HIGH VOLTAGE AMPLIFIER
TRANSFORMER OHMMETER OHMMETER dissipation factor test • High voltage amplifier for IDAX
• Uses same lead sets for 3 phase MTO and TTR • Serves as winding resistance & tap changer • High accuracy and wide measurement range • Test voltage 1.4hV AC RMS and 2kV DC
units test set • Automatic measurement process • Frequency range DC to 1kHz
• Offers fast set-up & lower safety risk with one- • Direct two-channel digital reading • Measures capacitive, resistive or inductive test
time connection • Uses DC test current up to a maximum of 10 A objects
• Has an internal computer and can be used to • Works with any standard capacitor or resistor
control other Megger products value without any recalculations
MRCT Megger Relay and TTR25 BASIC HAND-HELD TURNS TTR100 ADVANCED HAND-HELD
Current Transformer Test Set RATIO TEST SET TURNS RATIO TEST SET
• New, MRCT uses patented simultaneous multi- • Measures ratio from 0.8 to 20,000:1 & • Measures ratio, single- & three-phase
tap measurements reduces testing time by 20% excitation current up to 100 mA (one phase at a time)
on multi-tap CT’s • Simple, push-to-test operation • Is the ideal lightweight tester for field &
• Increased measurement accuracy to support • Allows printing/uploading of data in real time substation environments (3.3 lbs.)
metering class CT testing • Accuracy with highest turns ratio in a
• Measure all ratio’s and saturation curves on hand-held TTR
multi-tap CT’s with one lead connection
EasyLoc Rx/Tx Cable tester PFL SERIES PORTABLE CABLE FAULT SWG TRUCK MOUNT SYSTEM DIGIPHONE PLUS PINPOINTER
• Depth measurement at the push of a button LOCATION SYSTEM • Has more power & functionality than smaller • Applies innovative audio concepts and
• Compatible with 33 kHz systems • Provides quick & accurate fault location testers newest DSP technology
• Large display with automatic backlight • Allows for HV insulation testing up to 32 kV • Radar & additional power for distribution fault • Has intuitive, full-color user interface
• Integrates large color screen location • Protects user from high noise levels
• Three-stage capacitor & up to 3500 joules (OSHA compliant)
OWTS M28/M60 Medium Voltage VLF Cosine Rectangular Series ESG NT Digital Earth Fault VLF Sine wave Series
Partial Discharge Diagnosis 28/40/60/80 kVRMS Locator
System • Patented voltage shape recommended by • Fully automatic zero calibration • 34/45/54 kV models
• Identify, evaluate and locate partial discharge DIN-VDE and IEEE 400 standards • Integrated noise suppression • Uses sinusoidal wave technology with
(PD) faults in cable insulation • Portable VLF, DC and sheath fault testing unit • With conventional or histogram visualization optional internal/external tan delta
• Partial discharge measurement at power • Test all three phases simultaneously with 5µF of fault location • Enables withstand & tan delta dielectric
frequency from 28kV to 350kV at 0.1 Hz high capacity loss testing
• Semi- and fully automatic PD analyzing
software for defect location with mapping
feature
SMRT1 SINGLE-PHASE RELAY TEST SYSTEM SMRT36 THREE-PHASE RELAY TEST SYSTEM
• Tests electromechanical, solid-state & microprocessor-based • Three phase voltage, up to 6 currents with convertible voltage channels
over-current, voltage, directional, and current differential rerlays • Three phase high current & high power (60 A, 300 VARMS) per phase
• Incorporates high current & high power (75 A, 400 VARMS) • IEC 61850 capabilities (Goose and sample value) SMRT410 RELAY TEST SYSTEM
• IEC 61850 test capabilities (Goose and sample value)
• Combines high compliance voltage & high
current to test all electromechanical, solid-
state & microprocessor-based over-current
relays
• Up to 6 high current & high power
(60 A, 300 VARMS) current channels
• Up to four voltage & ten current channels with
convertible voltage channels
MRCT Megger Relay and Current Transformer Test Set STVI HAND-HELD CONTROLLER
• Works with SMRT, MPRT and MRCT test sets
• New MRCT uses patented simultaneous multi-tap • General purpose substation secondary circuit testing with
measurements reduces testing time by 20% on multi-tap 300V & 60A generators • High-resolution color touch screen
CT’s • Grouped testing: demagnetization, knee points, ratios, • Adapts to right- or left-hand operation
• Increased measurement accuracy to support metering class saturation curves, and more
CT testing • Measure all ratio’s and saturation curves on multi-tap CT’s
• Smallest and lightest 2kV secondary voltage injection unit with one lead connection
available • Built-in insulation resistance testing
• Integrated single phase relay test system
DDA-1600/3000/6000 CIRCUIT
BREAKER TEST SETS
• Test virtually all low-voltage, molded-
case & metal-clad, direct-acting AC
circuit breakers up to 6,000 A
• Digital signal processing technology,
variable firing angle & pulse duration
• Complies with NEMA AB-4 test
guidelines
CB-832/845 CIRCUIT BREAKER & OVERLOAD RELAY TEST SETS MS-2A CIRCUIT BREAKER &
OVER-CURRENT RELAY TEST SET
• Test by primary current injection
• Tests by primary injection
• Apply to thermal, magnetic or solid-state overload relays, molded-case circuit breakers and
ground-fault trip devices • Ground fault performance testing for
NEC 230.95
• Incorporate variable high-current output (1,800 A maximum for 832; 5,000 A maximum for 845)
• Applies to thermal, magnetic or solid-state
motor overload relays, molded-case circuit
breakers, ground-fault trip devices & over-
current relays
EGIL CIRCUIT BREAKER ANALYZER TM1700 CIRCUIT BREAKER TM1800 CIRCUIT BREAKER B10E AC/DC VOLTAGE POWER
• Measures timing & travel ANALYZERS ANALYZERS SUPPLY
• Tests three-phase breakers up to 240 kV • Time and travel analyzer • Time and travel analyzer • Provides reliable & stable power supply for
• 1 break per phase, single motion • Up to 2 breaks per phase, 3 motion • Up to 16 breaks per phase, 3 motion circuit breaker testing
• Performs dynamic resistance measuements • Reliable and accurate testing of circuit • Reliable and accurate testing of any MV or HV • Continuously variable 24-250 V AC or DC
(DRM) breakers up to 765kV circuit breaker output
• First trip and DRM • First trip and DRM • Separate outputs for close coil, trip coil &
• Compatible with CABA Win for running spring charging motor voltage
• Compatible with CABA Win for running
predefined test plans and advanced data predefined test plans and advanced data
management management
DLRO10/10X DIGITAL LOW DLRO10HD DIGITAL LOW 247000 SERIES DIGITAL LOW
RESISTANCE OHMMETERS RESISTANCE OHMMETER RESISTANCE OHMMETERS
• Measure resistance from 0.1 µΩ to 2,000 Ω • Bidirectional, unidirectional, automatic, • Provide simple, practical means of
• Select most suitable test current up to 10 A continuous and inductive modes low-resistance field tests DLRO-H200 Hand-held
• Produce accurate results in less than three • Rugged field enclosure • Measure resistance from 0.1 µΩ to 599.9 µΩ MICRO-OHMMETER
seconds • Line or battery-powered • Operate on four-wire measurement principle • Battery operated and weighs less than
• PowerDB functionality available on DLRO10X 2.5 lbs
only • Incorporates current to 240 A
• Uses Bluetooth headset for audible pass/
fail testing
PHAZER WATTHOUR METER MR-4 METER ADAPTER RECORDERS PA-9PLUS/WIRELESS POWER QUALITY ANALYZERS
TEST SET • Detect sags, swells, sub-cycle events, THD, • Measure to worldwide power quality standards (EN50160, IEC61000-4-15, IEEE1159/519)
• Built-in watthour, VAR-hour, Q-hour & VA-hour loose neutrals & flicker • Trend voltage, current, imbalance, power, energy, events, flicker (PST/PLT), THD, TDD,
testing capabilities • Ideal choices for split-phase residential individual harmonics & frequency
• True single- & three-phase testing options & light commercial • Allow for remote analysis/retrieval & remote configuration with wireless modem
• Fully automatic operation • Install quickly & safely with no exposed wiring (PA9Wireless only)
• Metreport analyzing software included
E-Z Test Meter Test Jacks PA-2505K PHANTOM LOAD SLM-8 VOLT AMMETER MDP SERIES DISTRIBUTION
• Simplify testing of socket-type watthour • Tests single- or poly-phase watthour meters • Detects loose neutral, sag & swell PROFILERS
meters • Operates from single-phase source • Records flicker • Record currents up to 1,000 A
• Dead-front construction & simplified • Choice of 50% & 100% power factor • Quick set-up & immediate analysis • Waveform capture & harmonic analysis up to
connection system 32nd order
• Withstand rigors of daily field use • Choice of three models
• Metreport analyzing software included
MIL/5M/1.2014