You are on page 1of 5

AT200 - AT200 AccuTrak High Accuracy Magnetostrictive Level Transmitter

T Mounting Top Connected Electronic Housin


L Transmitter Configuration Standard Local Transmitter Hous
S Transmitter Housing Type Dual Compartment Stainless Stee
R1 Probe Type Standard 0.625 in. Outer Diamet
M4A Electronic Module One Level, LCD Indicator & SIL 2
X Second Analog Output (Not SIL Rated) NONE
CEX Approval ATEX, Flameproof
GD1 Engineering Documents Drawings for Approval - NOTE: Le
GS1 Origin Documents Certificate of Origin
CAL Certifications Calibration Certificate
Measuring Length 1900 mm
Min. Process Temperature 40 °C
Max. Process Temperature 80 °C

Código: AT200TLSR1M4AXCEX-GD1GS1CAL

KM26S - KM26S Magnetic Level Gauge, Side Mounting

SS6 Chamber Material 316 / 316L Stainless Steel


SS6 Connection Material 316 / 316L Stainless Steel
D7 Top Connection Blind Flange with Float Stop Sprin
F3 Side Connection 1 Weld Neck Flange with Concentr
F3 Side Connection 2 Weld Neck Flange with Concentr
X Side Connection 3 None
D7 Bottom Connection Blind Flange with Float Stop Sprin
N078 Top Connection Size 0.75 in. // SCH 80 // Pipe Nipple
R31 Side Connection Size / Rating / Type 1 3 in. // ANSI / ASME Class 150 //
R31 Side Connection Size / Rating / Type 2 3 in. // ANSI / ASME Class 150 //
X Side Connection Size / Rating / Type 3 None
N078 Bottom Connection Size 0.75 in. // SCH 80 // Pipe Nipple
M1P Indicator Type Yellow / Black Magnetic Bar Grap
F Indicator Scale / Ruler Stainless Steel Housing, Custom S
U4 Approvals ATEX, Construction Safety
FLT05 Float 316 SS 1 7/8 in. float for 2 in. sch
VV Valves Vent Valve
DV Valves Drain Valve
GD1 Engineering Documents Drawings for Approval - NOTE: Le
CRA Radiographic Services Radiographic Examination on all
CNA Liquid Dye Penetrant Liquid Dye Penetrant Examinatio
CHC Positive Material Identification Positive Material Identification w
K5 Pressure Equipment Directive RoHS Compliance, No PED (Requ
CP2 Hydrostatic Examination Hydrostatic Examination with Ch
C2 Material Monitoring Material Monitoring with Inspec
GS1 Origin Documents Certificate of Origin
CPE Certifications Calibration Certificate of Hydrote
CN1 NACE NACE (MR 0103) Hardness Certifi
Minimum Specific Gravity 0,92
Operating Temperature 70 °C
Max / Design Temperature 100 °C
Operating Pressure 1,7 kPa
Max / Design Pressure 3 kPa
Measuring Length 1900 mm
Bolting A193 B7 studs, A194 2H nuts, ca
Gaskets Grafoil GHR, 1.5875 mm (0.0625
Vent Valve 0.75 in. 316 SS Ball Valve - Flow-T
Drain Valve 0.75 in. 316 SS Ball Valve - Flow-T

Código: KM26SSS6SS6D7F3F3XD7N078R31R31XN078M1PFU4-FLT05VVDVGD1CRACNACHCK5CP2C2GS1CPECN1
Top Connected Electronic Housing - Note - If chamber has Top Flanged Connection. Consult Facotory
Standard Local Transmitter Housing
Dual Compartment Stainless Steel Housing
Standard 0.625 in. Outer Diameter Probe
One Level, LCD Indicator & SIL 2 Rated, 4 ... 20 mA + HART Output

ATEX, Flameproof
Drawings for Approval - NOTE: Lead time will start after receipt of customer approved drawings
Certificate of Origin
Calibration Certificate

316 / 316L Stainless Steel


316 / 316L Stainless Steel
Blind Flange with Float Stop Spring and Mating Weld Neck Flange with Pipe Nipple, MNPT
Weld Neck Flange with Concentric Reducer
Weld Neck Flange with Concentric Reducer

Blind Flange with Float Stop Spring and Mating Weld Neck Flange with Pipr Nipple, MNPT
0.75 in. // SCH 80 // Pipe Nipple
3 in. // ANSI / ASME Class 150 // Raised Face Flange
3 in. // ANSI / ASME Class 150 // Raised Face Flange

0.75 in. // SCH 80 // Pipe Nipple


Yellow / Black Magnetic Bar Graph with Permanently Sealed Lexan® Tube (Max. 121°C / 250°F)
Stainless Steel Housing, Custom Stainless Steel Scale (percent, gallons, liters, etc.), Left Hand Ruler unless specified on Purchase Order
ATEX, Construction Safety
316 SS 1 7/8 in. float for 2 in. schedule 40 chamber, min. specific gravity 0.90
Vent Valve
Drain Valve
Drawings for Approval - NOTE: Lead time will start after receipt of customer approved drawings
Radiographic Examination on all Pressure containing Butt Welds / and all other welds are Liquid Dye Penetrant (Final Pass Only) (Per Tag)
Liquid Dye Penetrant Examination on all Pressure containing Welds (Final Pass Only) (Per Tag)
Positive Material Identification with Carbon Content
RoHS Compliance, No PED (Requires CP1 or CP2 in Hydrostatic Examination)
Hydrostatic Examination with Chart Recording - (30 Minutes)
Material Monitoring with Inspection Certificate 3.1 acc. EN 10204
Certificate of Origin
Calibration Certificate of Hydrotest Equipment (Requires CP1 or CP2 in Hydrostatic Examination)
NACE (MR 0103) Hardness Certificate (Requires C2 in Material Monitoring)

A193 B7 studs, A194 2H nuts, cad plated & dichromate dipped


Grafoil GHR, 1.5875 mm (0.0625 in.) thick
0.75 in. 316 SS Ball Valve - Flow-Tek FP-3-2-04
0.75 in. 316 SS Ball Valve - Flow-Tek FP-3-2-04

CRACNACHCK5CP2C2GS1CPECN1
specified on Purchase Order

etrant (Final Pass Only) (Per Tag)

You might also like