Project Settings
Project Title: SOSTENIMIENTO
Wedges Computed: Perimeter and End Wedges
Units: Metric, stress as tonnes/m2
Seismic Forces
Not Used
Joint Orientations
Joint 1
Dip: 55°
Dip Direction: 180°
Joint 2
Dip: 55°
Dip Direction: 060°
Joint 3
Dip: 55°
Dip Direction: 300°
Joint Properties
Joint Properties 1
Water Pressure
Constant: 0 tonnes/m2
Waviness: 0°
Shear Strength Model: Mohr-Coulomb
Phi: 35°
Cohesion: 10 tonnes/m2
Tensile Strength: 0 tonnes/m2
Bolt Properties
Bolt Property 1
Bolt Type: Mechanically Anchored
Tensile Capacity: 10 tonnes
Plate Capacity: 10 tonnes
Anchor Capacity: 10 tonnes
Shear Strength: Unused
Bolt Orientation Efficiency: Used
Method: Cosine Tension/Shear
Shotcrete Properties
Shotcrete Property 1
Shear Strength: 200.00 t/m2
Unit Weight: 2.600 t/m3
Thickness: 10.00 cm
Support Summary
Summary of Perimeter Shotcrete
No Shotcrete on Perimeter
Wedge Information
Floor wedge [1]
Factor of Safety: stable
Wedge Weight: 4.063 tonnes
Apex Height: 1.24 m
Scaled by: NOT scaled
Joint Trace Lengths: 1) 3.01 m, 2) 3.01 m, 3) 3.01 m
OPCIONES DE PANTALLA
Escalar las cuñas
La escala toma los valores verdaderos tomados en campo ya sea longitud
áreas
SOPORTE PERIMETRAL
Luego nos vamos a propiedades del perno la cuña del techo tiene un peso de 0,298tonelas la
cual sacamos la longitud de perno para hacer el sotenimiento y su respectivo espaciamineto
Una vez que compamos el perno el FS de la cuña aumenta