You are on page 1of 7

Q 2 m3/h 48 m3/day

Velocity 2 m/s Kawamura

A 0.000277778 m2
D 0.018811088 m
1.881108827 cm
0.740594026 in
pakai 1 in

v act
Q 2 m3/h
A 0.000277919 m2
vact 7196.349907 m/h
1.998986085 m/s

rapid mixing
tipe hidrolik
kriteria desain
detention time 1-3 s
G value 500-700 detik -1
GT 350-1500

coba static mixer 1 in 40 mm


stage 12 element 0.04 m

length SM 0.3168 m 31.68 cm


v act 1592.356688 m/h
0.442321302 m/s
detention time 0.71622144 s
headloss 0.2 m
rho 1000 kg/m3 asumsi mirip air tapi lebih berat dikit
miu 0.005 kg/ms asumsi mirip air tapi lebih berat dikit

G 739.8085988 detik-1
GT 529.8667799 OKE
air air
rho 1000 rho 1000
D 0.04 m D 0.04 m
v 0.442321 m/s v 0.442321 m/s
miu 0.000801 kg/ms miu 0.003 kg/ms
Nre 22096.73 turbulent Nre 5897.617 turbulent
flow rate 1 m3/h
4.402868 gpm
existing pipe dia 41 mm
4.1 cm
1.614173 in
abs viscosity 0.98 cps
SG 1.1
Dp 0.4 psi
T 40
P 14.7 psig

Re 9665.553

aliran turbulen
No of element 2
panjang mixer 3 in
V 0.689439 ft/s