Thickness of fire resistant mortar and mm + concrete
75 mm ThFinsih 150 mm
Dtop
h Pn Bricks + cellular
concrete
H
Ph
slope
w
slope Dbottom
Hopper schematics
Weigth of ash volume of ashxDensity of ash W1 = 17.8 kN
Minimum steel required 0.12% of 150 mm thk rcc slab = 180 sqmm/m
Provide 10@ 150c/c (curtailed to maintian spacing of 150mm cc) = 500 sqmm/m
Ast provided for direct tension (longitudinal steel)
Normal component of pressure Pn = Dash x h x {cos2(slope) + cos2(slope)xcos2(phi)} = 6.6 kN/sqmm
due to ash at center of slab h = H/2 (height at mean dia)
Minimum steel required 0.12% of 150 mm thk rcc slab = 180 sqmm/m
Provide 10@ 200 c/c Ast provided for direct tension (longitudinal steel) = 400 sqmm/m