Table 5.

4
Canadian (only) optional Performance Grades (PG)
(See Clauses 0.2.5.1, 4.3.2.2, 4.4.3.2, 4.4.3.3, 4.4.3.4, 5.2.1, 6.4.4, 9.3.4.2, and 9.3.4.3 and Table
0.1.)

Performance Class and Water penetration


optional Performance Design pressure Structural test resistance test
Grades (PG) (DP) pressure (STP) pressure

R LC Pa (~psf) Pa (~psf) Pa (~psf)

20 — 960 (20.05) 1440 (30.08) 150 (3.13)

25 — 1200 (25.06) 1800 (37.59) 180 (3.76)

30 30 1440 (30.08) 2160 (45.11) 220 (4.59)

35 35 1680 (35.09) 2520 (52.63) 260 (5.43)

40 40 1920 (40.10) 2880 (60.15) 290 (6.06)

45 45 2160 (45.11) 3240 (67.67) 330 (6.89)

50 50 2400 (50.13) 3600 (75.19) 360 (7.52)

55 55 2640 (55.14) 3960 (82.71) 400 (8.35)

60 60 2880 (60.15) 4320 (90.23) 440 (9.19)

65 65 3120 (65.16) 4680 (97.74) 470 (9.82)

70 70 3360 (70.18) 5040 (105.26) 510 (10.65)

75 75 3600 (75.19) 5400 (112.78) 540 (11.28)

80 80 3840 (80.20) 5760 (120.30) 580 (12.11)

85 85 4080 (85.21) 6120 (127.82) 610 (12.95)

90 90 4320 (90.23) 6480 (135.34) 650 (13.58)

95 95 4560 (95.24) 6840 (142.86) 680 (14.41)

100 100 4800 (100.25) 7200 (150.38) 720 (15.04)

Note: The IP equivalents identified are for approximate reference only and do not in any way imply
accuracy of the measurement or the equipment. See Clause 1.3. Precision and bias statements are
provided in the applicable test methods referenced in this Standard/Specification.