Professional Documents
Culture Documents
: 1
GOVERNMENT OF INDIA
MINISTRY OF RAILWAYS
TITLE:
DRAFT SPECIFICATION
for
SPECIFICATION OF INTEGRATED STM-1 / STM-4 & PRIMARY
MULTIPLEXER.
Specification No.
TELECOM DIRECTORATE
RESEARCH DESIGN & STANDARDS ORGANISATION
MANAK NAGAR, LUCKNOW – 226001
Specification Revision
RDSO/SPN/TC/53/2009 1
Title of Document
Author
Approved by
Shri M. Alam
Executive Director/ Telecom/ RDSO
Abstract
REVISIONS:
I. SUMMARY :-
II. SOURCE
III. FOREWORD
RDSO/ SPN along with comments received from various quarters is discussed
in Telecom Standards Committee Meeting (TCSC). Recommendation made by
TCSC is put up to Railway Board for approval. After approval from Railway
Board, the specification is given an IRS number and issued as Indian Railway
Standard Specification.
Page 6 of 12 Effective from : 07/08/09 RDSO/ SPN/TC/53-2009 Rev. : 1
CONTENTS
2. Specification of STM
3. Specification of PD Mux
4. Synchronisation
7. Power Supply
8. Environmental Conditions.
c) Alarm acquisition (Optional feature): The equipment shall have facility to accept
and extend the Relay based or Voltage based External Alarm signals or Control
Signals from any of the Central and or Regional Stations to any of the Remote
Stations. The alarms should be monitored through NMS/ LCT . The equipment
should be able to support 24 such binary alarm inputs and should be able to
deliver 4 Binary command outputs. The command outputs should be switched
either through NMS/ LCT or through the alarm inputs. This feature is optional
feature and shall be provided if required by the purchaser . The purchaser shall
also give the exact number and type of such alarms and number of binary
command outputs required by him while ordering.
1.1 The equipment should support following multiple technologies with common
mother board & chasis.
2.1 Specification of STM-1 shall be as per TEC Generic Requirement No. GR/ SDH-
04/03 March’ 2005 in addition to those mentioned in this document.
Page 8 of 12 Effective from : 07/08/09 RDSO/ SPN/TC/53-2009 Rev. : 1
2.2 The equipment shall work on the single mode optical fibre cable as per IRS
specification No. IRS:TC 55-2006 with latest amendments.
2.4 The equipment shall be capable of working at 1310 nm and 1550 nm window of
operation as per ITU-T G 957.
• Bus Topology
• Mesh Topology
• Terminal Mux
SNC-N protection
• STM -1 e
• 34 Mb/s PDH
• 2 Mb/s PDH
Page 9 of 12 Effective from : 07/08/09 RDSO/ SPN/TC/53-2009 Rev. : 1
3.1 Specification of 2 Mbps Drop Insert P.D Mux shall be as per IRS specification
No. IRS:TC 68-04 with latest amendments, save as mentioned in this document.
• 2W E&M
• 4W E&M
• 2W subscriber loop
• 2W exchange loop
• 2W hot line
• Low speed data interface Sync/ Async, RS 232 C/ V.24/ X.21
• 64 kbps data interface G.703/ V.35/ V.36
• N x 64 Kbps data interface V.35/ V.36
• E1 branching interface
• IDSL alongwith NTU
• SHDSL (As per RDSO/SPN/TC/052-2005)
3.3 The equipment shall have facility for a minimum of 18 three way conference
among any combination of time slots (64 kbps channel) and V.F side.
3.4 It shall also be possible to configure more than 3 way conference circuits with a
combination of time slots (64 kbps channel) and V.F side. The supplier shall
indicate the reduction in number of conference circuits in such a case.
4.0 SYNCHRONISATION
4.1 The synchronisation of the system shall be done in accordance with TEC Generic
Requirement No. GR/SDH-04/03 March’ 05 for STM-1 and as per TEC GR
SDH-10/02. March’ 2005 for STM-4.
Page 10 of 12 Effective from : 07/08/09 RDSO/ SPN/TC/53-2009 Rev. : 1
5.1 The equipment must support full cross-connect capability with a granularity of
VC4, VC3, VC12 and 64 kbps as per TEC GR No. GR/SDH-04/03 March’05 and
IRS specification No. IRS:TC 68-04 with latest
amendments. In case of STM-4, the cross connect capability shall be as per TEC
GR SDH-10/02. March 2005
6.1 The equipment shall provide general management functions, alarm generation and
reporting, NMS and local craft terminal as per TEC Generic Requirement No.
GR/SDH-04/03 Mar’ 05 and IRS specification No. IRS:TC 68-04 with latest
amendments. In case of STM-4, provisions of TEC GR SDH-10/02. March 2005
shall be followed. The specification of LCT and servers as per relevant GR are
indicative, and detailed specification shall be provided by the purchaser.
7.1 Nominal power supply is -48 volts DC with a variation over the range -36 V to
- 72 V. The equipment should operate over this range without any degradation in
performance.
7.2 The equipment shall be adequately protected in case of voltage variation beyond
the range as specified in clause 7.1 above and also against input reverse polarity.
7.3 The derived DC voltages in the equipment shall have protection against over
voltage, short circuit and overload.
8.1 The range of ambient temperature and humidity within which the equipment
performance specification shall be met as well as the range within which the
equipment is to remain operational without any irreversible damage are as under
(As per QM 333 Table 4.3 Category B):
8.2 The environmental testing shall be conducted as per specification No. QM 333 for
environmental testing of electronic equipments for transmission and switching use
issued by DOT in September’ 1990. The testing shall be as per category ‘B2’ and
following tests shall be carried out:
a) Cold
b) Dry heat
c) Damp heat (cyclic)
d) Rapid temp. Cycling
e) Damp heat steady state
f) Vibration
End of document