Congratulations on your decision to give your baby the best possible start
in life by breastfeeding. The multitude of health benefits for both you and
your baby are well documented. Although breastmilk is always best, providing
breastmilk for your baby when you have to be away isn’t always easy. It
requires a special effort, and you should be very proud of your commitment to
provide your baby the perfect nutrition for ideal growth and development. Our
electric breast pump Pro was designed to be the best for mothers who want
to find own pumping style and to optimize pumping experience.

Please read these operating instructions prior to using the


pump to ensure correct operation. Keep the instructions in a
safe place after reading.

Batteries are not included in the product. Please prepare four AA alkaline
batteries to use the breast pump with batteries.

Product features
Top-performing* model for maximizing milk production and comfort.
1. New “Comfort ProperFit™ flange” fits your breast perfectly
The large, soft cover gently cups your breast to prevent air leaks.

2. Two “Stimulation modes” to gently stimulate your breast Suction pressure


Applies gentle stimulation to your breast when you start
expressing. Choose from two different speeds—Slow
mode (MODE 1) or Moderate mode (MODE 2). Time

3. “Expression mode” allows you to control the suction Suction pressure


pressure and speed.
You can set the appropriate suction pressure (7 power
levels) and speed (4 levels) for optimizing pumping Time
experience.
You can customize suction pressure and speed to suit your breast condition on a particular day.
This reduces breast discomfort and allows you to express gently and smoothly.
* In terms of the number of levels that can be set for the suction pressure and speed in the Pigeon breast pump
series. As of February 2014.

2
Breast pump parts
Large Comfort Main body Regular Comfort
ProperFitTM flange cap ProperFitTM flange

Soft cup

Motor AC adapter

Large flange Main body Regular flange


Hood

Silicone valve Nipple


* One spare silicone Bottle (SS size)
Tube valve is included.
Tube connector Cap

Bottle stand Sealing


disk

Operations and display area


Stimulation mode button
■ If you are in Stimulation mode Suction adjustment buttons
You can adjust the speed. ■ If you are in Expression mode
■ If you are in Expression mode You can adjust the level of
You can switch from “Expression suction pressure and speed.
mode” to “Stimulation mode.”

Expression mode button


Power button
■ If you are in Stimulation mode
You can switch from “Stimulation
mode” to “Expression mode.”
■ If you are in Expression mode <Battery level display>
Choose whether you want to adjust Full
the suction pressure or speed.

Displayed when using batteries. * If the batteries are low,


it might not be able
to achieve sufficient
Displayed when using the AC adapter. Flashing Empty suction.

• The screen is backlit for 30 seconds when you press a button.


• The power is automatically switched off, if the power is on but the pump has not been used for 60 minutes.

3
Precautions for use
Important Safeguards
When using electrical products, especially when children are present, basic safety precautions
should always be maintained, including the following:
PLEASE READ THIS BEFORE USING THE PUMP
The following symbols indicate incorrect handling that can result in injuries or damage.

Indicates incorrect handling that can Indicates incorrect handling that can
cause major injury or death. cause injury or property damage.
Warning Caution
The following symbols indicate important instructions that must be followed.

Indicates steps that must be taken. Indicates actions that are prohibited
Instruction Prohibited
Danger: To reduce the risk of electrocution:
• Always unplug this product immediately after using. • Do not use while bathing. • Do not place or store this
product where it can fall or be pulled into a tub or sink. • Do not place or drop pump into water or other liquid.
• Do not reach for an electrical product that has fallen into water. Unplug immediately.

Warning: To reduce the risk of burns, electrocution, fire, or injury to persons:


Close supervision is necessary when this Be careful not to damage the AC adapter. (Do
product is used near children or invalids. not scratch, modify, place near a heater, bend
This product should never be left unattended excessively, twist, pull, place heavy objects
when plugged in. on, or bundle it.) Doing so may cause fire,
electric shock, or failure.
Use this product only for its intended use
as described in this manual. Do not use Never use an AC adapter other than the one
attachments not recommended by the provided. Doing so may cause fire, electric
manufacturer. shock, or product failure.

Never operate this product if it has a damaged Keep the cord away from heated surfaces.
cord or plug, if it is not working properly, if it
has been dropped or damaged, or dropped Never use while sleeping or drowsy.
into water.
Never drop or insert any object into any
Wipe thoroughly, if there is dust on the AC opening or tubing.
adapter attachment plug.
Do not use this product if it is broken or any
Failure to do so may cause fire.
parts are missing.
Do not disassemble or modify the AC adapter
Do not allow small children or pets to play
and motor. Doing so may cause fire as a result
with the pump unit, AC adaptor, etc.
of electric shock or contamination.
Do not use outdoors with the AC adapter
Do not insert or remove the AC adapter
or operate where aerosol spray products
attachment plug with wet hands. Also do not
are being used or where oxygen is being
handle batteries with wet hands. Doing so
administered.
may cause electric shock.

4
Caution
This breast pump is intended for use by a Do not expose the pump to severe shocks
single user only. such as dropping or throwing. Doing so may
Do not use excessively or for continued cause malfunction or damage.
suction. Doing so may cause nipple pain. Do not express more
Stop using the breast pump if your nipples than 160 ml of liquid
are sore. Continued use may cause your into the bottle. The
symptoms to worsen. expressed breastmilk
may overflow.
Do not wipe with thinners, benzine, or alcohol.
Doing so will cause deformities and damage. Prior to using the pump, check to make sure
there are no abnormalities such as scratches,
Do not use detergents that contain abrasives.
breaks, cracks, or deformities.
Doing so will cause scratches to the product.
Clean your hands before expressing.
Do not leave it near an open flame. Doing so
will cause deformities and damage. Wash and sterilize before using.

Not working properly?


No power
Using the pump with an AC adapter
• Is the AC adapter plugged in to the motor and outlet properly?
Using the pump with batteries
• Are the batteries inserted in the correct positive and negative direction?
• Are the batteries out of charge?
There is no suction
Is the flange fitting around your breast properly?
* If there is a gap between the flange and your breast, you may not feel sufficient suction.
Is the Comfort ProperFit™ flange firmly attached to the flange?
* You may not feel sufficient suction, if there is a gap between the flange and the Comfort ProperFit™ flange.
Is the tip of the silicone valve torn?
* There will be no suction if the silicone valve is torn or scratched. Replace it with the spare silicone valve.
Is each part assembled correctly?
• Is the soft cup placed inside the main body?
• Is the flange firmly inserted in the main
body? Direction of the soft cup
• Is the soft cup turned inside out? Correct direction Inside out
* If you are unable to insert it properly, check
View from No groove inside Groove inside
the shape of the soft cup and try to insert it
again. diagonally
• Are you using the exclusive soft cup? above
Using the pump with batteries
• Are the batteries low? Cross-
* If the batteries are low, it might not be able sectional
to achieve sufficient suction. diagram

5
How to assemble breast pump
1 Hold the base of the silicone valve and attach 2 Attach the soft cup to the main body.
it to the main body.

3 Attach the main body cap to the main body. 4 Screw the main body onto the bottle.
Align the symbol on the main body with
the symbol on the main body cap and
then turn to attach it.

5 Attach the Comfort ProperFitTM flange cover 6 Attach the flange to the main body.
to the flange.

7 Press the bottle into the bottle stand. 8 Attach the tube to the main body.

6
9 Attach the tube connector to the tube. 10 Attach the tube connector to the motor.

■ Using the pump with batteries


Remove the battery cover from the base of the motor
and insert four AA alkaline batteries.
* Replace all four batteries at the same time.
* If you will not use the product for an extended period,
remove the batteries.
* Do not use the product with a mix of new and old
batteries.
* Use alkaline batteries to ensure smooth suction
pressure.

■ Using the pump with an AC adapter


Insert the AC adapter plug firmly into the socket on
the motor, and then insert the AC adapter into the
outlet.
* The AC adapter may become warm while in use. This is
not a problem.
* Always remove the adapter from the outlet when not in
use.

To disassemble, follow the assembly procedure in reverse.

7
How to use breast pump

This breast pump has two modes, “Stimulation mode” and “Expression mode.”
To start expressing
Applies gentle stimulation to your breast when you start expressing.
Stimulation mode
Choose from two different speeds—Slow mode (MODE 1) or
Moderate mode (MODE 2).

You can set the appropriate suction pressure (7 power levels) and
Expression mode
speed (4 speeds) for expressing.

Center the flange over your papilla and press it against your breast. Seal
1
it securely so that no air can escape. You can create a good seal by
using your other hand to support your breast from underneath.
* If your nipples are large and they touch the cover, we recommend using the
large flange.

2 To turn the power on, press .


“Stimulation mode” starts automatically and timer also starts to track
the usage time when you turn the power on.
* You will hear a clicking sound when the pump is in operation. This is the
normal operating sound of the valve that releases the suction power.

3 Stimulation mode
Confirm that your nipple/papilla is moving and suction is being applied.
The display switches as shown below each time you press the button so that you can adjust
the speed.


When breastmilk starts coming out (or after 1-2 minutes), switch to
“Expression mode”.
The pump automatically switches to “Expression mode” 2 minutes after
“Stimulation mode” starts.
If you want to continue using “Stimulation mode,” press to switch
back to “Stimulation mode.”

8
4 Expression mode
To switch to “Expression mode,” press .
In “Expression mode”, you can adjust the suction pressure and speed.
The flashing display changes as shown below each time you press .

Flashing Flashing


■ To adjust the suction pressure
While “POWER” is flashing, press or to adjust the suction power (7 power levels).

Weak Strong

7 power levels

■ To adjust the speed


While “SPEED” is flashing, press or to adjust the speed (4 speeds).

Slow Fast

4 speeds

Caution
Drastic changes in the suction pressure and speed may cause nipple pain. See your condition, and
adjust the suction pressure and speed that is suitable for you.
Expressing for an excessively long time may cause nipple pain. Aim to express from each nipple for
approximately 10 minutes. The amount of expressing varies depending on the nipple conditions of
each mother. See your condition and express accordingly.

5 When you finish expressing, press to turn off the power.


When you are certain that suction has stopped, gently remove the flange from your breast.

9
About the breast pump
This breast pump is for expressing breastmilk when you want to store it and feed it to your
baby later, or if you have problems with your nipples and are unable to breastfeed your baby
directly.
Correct use of this pump will allow you to enjoy feeding breastmilk to your baby. Every mother
expresses breastmilk differently. We recommend that you experiment to find the settings that
are most comfortable for you.

Breastmilk facts
Breastmilk originates from a mother’s blood.
Breastmilk is made from the mother's blood. It may seem hard to believe that red blood can turn into
white breastmilk. How does this happen? Breastmilk does not contain any of the red blood cells that make
blood red. The cells that produce breastmilk are surrounded by a great number of blood capillaries. When
the blood capillaries come into contact with the cells, the nutrients from the blood pass into the cells, and
breastmilk is formed. Breastmilk is a very important gift from a mother to a baby. Try to maintain a regular
lifestyle so that you can provide your baby with the best possible breastmilk.
What causes breastmilk secretion?
Breastmilk is ejected as a result of prolactin activity. Prolactin is a lactogenic hormone that is secreted by
the anterior pituitary gland. Prolactin activity is suppressed by the large quantities of estrogen and luteal
hormone that are secreted from the placenta during pregnancy. When the placenta is discharged following
birth, suppression ends, breastmilk is produced, and secretion is promoted. In addition, sucking by a baby
(peristaltic movement) stimulates the breast, releasing the hormone oxytocin, and causing breastmilk to
be secreted (breastmilk ejection). The more frequently your baby sucks, the easier it is for breastmilk to be
ejected.

How to store expressed breastmilk


Your breastmilk is full of nutrition. To keep it fresh for future use, insert a sealing disk into the
cap, screw the cap tightly onto the nursing bottle, and store the bottle in the refrigerator.
• Do not microwave braestmilk as much of the nutritive value
will be lost. Freezer Refrigerator
• Do not leave braestmilk sitting at room temperature. Fresh breastmilk 3 weeks 24 hours
• Do not refreeze breastmilk that has been defrosted.
• Do not combine fresh breastmilk with stored one. Thawed breastmilk Do not refreeze 24 hours

10
How to take care of the pump
• Always disassemble the parts before washing and sterilizing.
• Do not wash or sterilize the motor, tube connector, or AC adapter.
Caution
Motor
• Do not wipe the motor with a wet towel or wash with water.
• If it is dirty, apply detergent to a cloth and wipe clean.

Other parts
• Wash and sterilize the pump before using it for the first time.
• Soak the pump in lukewarm water and wash them by using a detergent such as “Pigeon Liquid Cleanser” after
use. Please make sure to rinse thoroughly after washing.
• Sterilize the parts after washing.
• Be careful not to lose small parts when washing the pump parts.
• Use a soft sponge brush for washing.
• Do not handle silicone rubber parts roughly. Doing so will cause tears or scratches.
• Do not clean with a scourer, polishing powder, or hard brush. Doing so will scratch the surface.

Caring for the included nipple


• To protect the ventilation valve, a white powdered food additive has been
applied. Before using for the first time, wash thoroughly. Nipple hole
• Use both hands to clean the ventilation valve, vent, and nipple hole by
rubbing gently. If you scrub or pull on it too hard, the valve may split, and Vent
it causes leaks. Ventilation valve
• The tip of the nipple is extremely delicate. Push the tip of the nipple with
your finger when washing with a cleaning brush.

[Boiling sterilization]
• Place thoroughly washed parts in a large pot filled with water. Bring to a boil. Sterilization time is 5 minutes after
the water comes to a boil.
• If there is not enough water, parts may stick to the side of the pot and become deformed.
• Do not boil excessively. Doing so can quickly damage the product.

[Steam sterilization]
• Use a sterilizer designed specifically for nursing bottles and nipples. Please read and follow the instructions that
come with the product.

[Chemical sterilization]
• Use a disinfectant designed specifically for nursing bottles and nipples. Please read and follow the instructions
that come with the disinfectant.
• The color of printing on the bottle may fade in case of chemical sterilization.

[Microwave sterilization]
• Be sure to use containers that are designed specifically for microwave sterilizing.
• Parts cannot be placed directly in the microwave for sterilization.
* Follow the sterilizing instructions that come with the product.
* Follow the instructions that come with your microwave.

11
About the included nursing bottle and nipple
This nipple can only be used with Pigeon Peristaltic PLUS™ Nursing Bottle.
Note: If your baby becomes comfortable with one certain nipple, he or she may object new ones. So rotate 2 or more
nipples and replace them about every 2 months. If the nipples become worn out, replace them without regard to how
many times they have been used.

For your child’s safety and health


• Always use this product with adult supervision. • Never use nipples as a soother. • Continuous
and prolonged sucking of fluids will cause tooth decay. • Always check food temperature before
feeding. • Keep all components not in use out of the reach of children. • Inspect before each
use and pull the nipple in all directions. The nipples may be worn by biting. Special attention is
needed for teething child. Throw away at the first signs of damage or weakness. • Clean before
each use. • Do not leave a nipple in direct sunlight or heat, or leave in disinfectant (“sterilizing
solution”) for longer than recommended, as this may weaken the nipple. • When not in use, keep
in a dry, covered container.

Warning Follow the warnings below carefully. Not doing so can cause burns.
• The bottle may become hot when preparing formula. Be careful not to burn yourself. • Do
not prepare formula near your baby, as there is a danger of burns. • Be sure to check the
temperature of the milk or other fluid before feeding. • The bottle may be hot after boiling or
microwave sterilization. Be careful not to burn yourself. • When preparing formula, if you shake
the upright bottle, hot liquid may gush out, causing burns. Handle the bottle carefully. • Do not
attach the hood and shake the bottle. If the hood is attached, the high temperatures may cause
the pressure inside the bottle to rise, leading to leaks or spouting of the hot liquid.

• Nursing bottles are for feeding your baby milk or other drink. Do not use them for any other purpose.
• The scale on the nursing bottle can be used as a guide when preparing formula. If you need to be more
precise, use a measuring cup or measuring spoon.
Formula
See the milk powder package for details on how to prepare formula.
Feeding
Feed your baby the formula after cooling it to approximately body temperature.
• Only a caregiver should feed the baby. • If you tighten the cap too hard, the nipple may collapse. • Consume the
formula immediately once prepared. Discard any formula if you don’t use within 2 hours of preparation.

How to assemble nipple and cap *Insert the nipple into top of the cap.

Gently pull the Grasp the shield Place over the cap. Press down firmly. Press with your
ventilation valve on firmly. finger to make sure
the nipple flange that the ventilation
from behind and valve opens.
check whether the
ventilation valve
opens.

12
Assurance
Pigeon Electric Breast Pump Pro Warranty
Thank you for buying this Pigeon product; we hope you will be happy with it.

* With this warranty, Pigeon guarantees the product to be free from defects in materials and workmanship
for a period of 1(one) year from the date of purchase by its first use. Repairs or replacement under the
warranty will be provided to you without charge.
* If still under the warranty period, prepare a proof of purchase documents, such as an invoice or receipt.
And contact your nearest Pigeon subsidiary or distributor to make arrangements.
* The warranty does not apply to products used in the course of a business, trade or profession. The
warranty does not cover any problems resulting from externally caused damages, use outside the
product’s specifications, faults caused by non-professional or non-approved repairs or from the use of
non-Pigeon accessories and AC adapters.
THE WARRANTY IS OFFERED AS AN ADDITIONAL BENEFIT TO YOUR STATUTORY RIGHTS AND
DOES NOT AFFECT THESE RIGHTS IN ANY WAY.

Quality indication
Parts name Material Heat resistance Sterilization method
Main body / Flange /Main body cap /
Polypropylene 120˚C
Bottle stand / Hood / Cap
Boiling, Steam,
Bottle Polypropylene 110˚C
Microwave,
Comfort ProperFit™ flange / Chemical
Soft cup / Tube / Silicone valve / Silicone rubber 120˚C
Nipple / Sealing disk
Tube connector ABS resin —
Do not wash or
Motor — —
sterilize
AC adapter — —

Rated specifications
Motor Power: DC 6 V (AC adapter or four AA alkaline batteries)
Dimensions: 60 mm (height) x 140 mm (width) x 120 mm (depth)
Weight: Approximately 315 g (without batteries)
AC adapter Input: AC100-240v 50/60Hz
Output: 6 VDC 1.2A