Professional Documents
Culture Documents
FED ALL
YELLOW AUXILIARY POWER (ELECTRIC PUMP) - SERVICING
WARNING : BEFORE PROCEEDING WITH MAINTENANCE WORK ON OR NEAR
MECHANICAL FLIGHT CONTROLS OR PRIMARY FLIGHT CONTROL
SURFACES, LANDING GEARS, ASSOCIATED DOORS OR ANY MOVING
COMPONENT, MAKE CERTAIN THAT GROUND SAFETIES AND OR
WARNING NOTICES ARE IN CORRECT POSITION TO PREVENT
INADVERTENT OPERATION OF CONTROLS.
BEFORE POWER IS SUPPLIED TO THE AIRCRAFT MAKE CERTAIN
THAT ELECTRICAL CIRCUITS UPON WHICH WORK IS IN PROGRESS
ARE ISOLATED.
BEFORE PRESSURIZING HYDRAULIC SYSTEMS, MAKE CERTAIN THAT
HYDRAULIC SYSTEM UNDER MAINTENANCE HAS BEEN ISOLATED.
1. Yellow System Electric Pump Start Up
A. Reason for the Job
Pressurization of Yellow auxiliary hydraulic system using
Yellow system electric pump.
B. Equipment and Materials
ITEM DESIGNATION
C. Procedure
FED 650-665,667-686,716-733,740-746,748-751
(Ref. Fig. 301 )
FED 687-692
(Ref. Fig. 302 )
FED ALL
(1) Job Set-Up
(a) Check Yellow hydraulic reservoir fluid level, top
up if required.
(Ref. 12-12-29, P. Block 001 )
(3) Close-up
(a) Depressurize system if required using pressure
relief manual decompression valve 3067.
(b) De-energize the aircraft electrical network (Ref.
24-41-00, P. Block 301 ) .
(c) Remove warning notices
(d) Remove all ground handling and maintenance
equipment, standard and special tools together
Figure 301
Figure 301. Yellow System Electric Pump Start-up (Sheet 1)
FED 687-692
Figure 302
Figure 302. Yellow System Electric Pump Start-up (Sheet 1)