NYY 

These low voltage cables 
are applied for common 
indoor, outdoor installation 
and underground.

Construction

Conductor or stranded 
annealed copper conductor

Insulation

Extruded colored PVC, 
capable for the operating 
continuously maximum 
temperature of the cable

Inner Sheath

Extruded black PVC filler

Outer Sheath

Extruded black PVC 
suitable for the operating 
continuously of the cable

Identification of cores

Complying with system O/I 
(other colors on request)

Specification: SPLN 43­
3:1981, SNI 04­2701­1999

NYA 
These low voltage flexible 
cables are applied for dry 
rooms, fixed installation in 
pipe and distribution panel 
connector

Construction

Solid or stranded annealed 
copper conductor 

Insulation

Extruded colored PVC, 
capable for the operating 
continuously maximum 
temperature of the cable

Sheath

Extruded white PVC 
suitable for the operating 
temperature of the cable

Identification of cores

Complying with system O/I 
(other colors on request)

NYAF 
These low voltage flexible
 cables are applied for 
drying rooms, fixed 
installation and distribution 
panel instead of NYA cable.

Construction

Conductor or stranded 
annealed copper conductor 
with cross section 0.5 mm² 
up to 400 mm²

Insulation

Extruded colored PVC, 
capable for the operating 
continuously maximum 
temperature of the cable

Color: green/yellow, blue, 
red, black and yellow

Identification of cores

Complying with system O/I 
(other colors on request)

NYFGbY 
These low voltage cables 
are applied for common 
indoor, outdoor installation 
and underground.

Construction

NYFGbY & NYRGbY      : 
solid, stranded or sectoral 
shape annealed copper 
conductor

NAYFGbY & NAYRGbY: 
s olid, stranded or sectoral 
shape annealed aluminium 
conductor

Armour

NYFGbY & NYRGbY      : 
galvanized steel flat and 
wrapped with galvanized 
steel tape

NAYFGbY & NAYRGbY:
 galvanized steel wire and 
wrapped with galvanized 
steel tape

Insulation

Extruded colored PVC, 
capable for the operating 
continuously maximum 
temperature of the cable

Outer Sheath

Extruded black PVC 
suitable for the operating 
temperature of the cable

Identification of cores

Complying with system O/I
(other colors on request)
Specification: SPLN 43­
2:1981, SNI 04­2700­1999

NYM 

These low voltage cables 
are applied for common 
indoor installation but not 
underground.

Construction

Conductor or stranded 
annealed copper conductor

Insulation

Extruded colored PVC, 
capable for the operating 
continuously maximum 
temperature of the cable

Inner Sheath

Extruded black PVC filler

Outer Sheath

Extruded white PVC 
suitable for the operating 
temperature of the cable

Identification of cores

Complying with system O/I 
(other colors on request)

Specification: SPLN 42­
2:1992, SNI 04­2699­1999

NYYHY 
These low voltage flexible 
cables are applied for indoor
and outdoor especially for 
light mobile appliances

Construction

Conductor or stranded 
annealed copper conductor 
with cross section 0.75 mm² 
up to 2.50 mm²

Insulation

Extruded colored PVC, 
capable for the operating 
continuously maximum 
temperature of the cable

Sheath

Extruded black  PVC 
suitable for the operating 
temperature of the cable

Identification of cores

Complying with system O/I 
(other colors on request)

NYMHY 
These low voltage flexible 
cables are applied for light 
mobile appliance with 
medium mechanical stresses
and heating appliance in dry
rooms and household 
appliances in humid rooms.

Construction

Conductor or stranded 
annealed copper conductor 
with cross section 0.75 mm² 
up to 2.50 mm²

Insulation

Extruded colored PVC, 
capable for the operating 
continuously maximum 
temperature of the cable

Sheath

Extruded white PVC 
suitable for the operating 
temperature of the cable

Identification of cores

Complying with system O/I 
(other colors on request)

NYFGbY control 

NYFGbY control cable 1.5 mm2 NYFGbY control cable 2.5 mm2