You are on page 1of 2

Modbus Address Flow Comp Samberah

No Signal Name Remark


Holding Register
1 RUN1_PRS_PSIG 1 Pressure Reading (Psig)
2 RUN1_TMP_DEGF 3 Temperature Reading (Deg.F)
3 RUN1_DP_INH2O 5 Differential Pressure Reading (inH2O)
4 RUN1_FLOW_MSCFD 7 Flow Rate Reading (MMSCFD)
5 RUN1_VOLM_TH 9 Volume This Hour (MMSCF)
6 RUN1_VOLM_LH 11 Volume Last Hour(MMSCF)
7 RUN1_VOLM_TD 13 Volume This Day(MMSCF)
8 RUN1_VOLM_LD 15 Volume Last Day (MMSCF)
9 RUN1_VOLM_TM 17 Volume This Month(MMSCF)
10 RUN1_VOLM_LM 19 Volume Last Month(MMSCF)
11 RUN1_DIAM_ORIF_M 21 Inside Diameter Orifice (inch)
12 RUN1_DIAM_PIPE_M 23 Inside Diameter Pipe (inch)
13 RUN1_PRS_ZERO 25 Pressure Transmitter Zero Cal. (Psig)
14 RUN1_PRS_SPAN 27 Pressure Transmitter Span Cal. (Psig)
15 RUN1_TMP_ZERO 29 Temperature Transmitter Zero Cal. (Deg.F)
16 RUN1_TMP_SPAN 31 Temperature Transmitter Span Cal. (Deg.F)
17 RUN1_DP_ZERO 33 Diff. Pressure Transmitter Zero Cal. (inH2O)
18 RUN1_DP_SPAN 35 Diff. Pressure Transmitter Span Cal. (inH2O)
19 RUN1_ENG_MMBTUD 37 Energy Rate Reading (MMBTUD)
20 RUN1_PRS_UPSTREAM 39 Pressure upstream (psig)
21 Gas1_METHANE 41 Gas1 Methane Composition (%Mole)
22 Gas1_NITROGEN 43 Gas1 Nitrogen Composition (%Mole)
23 Gas1_CO2 45 Gas1 CO2 Composition (%Mole)
24 Gas1_ETHANE 47 Gas1 Ethane Composition (%Mole)
25 Gas1_PROPANE 49 Gas1 Propane Composition (%Mole)
26 Gas1_BUTANE_I 51 Gas1 I-Butane Composition (%Mole)
27 Gas1_BUTANE_N 53 Gas1 N-Butane Composition (%Mole)
28 Gas1_PENTANE_I 55 Gas1 I-Pentane Composition (%Mole)
29 Gas1_PENTANE_N 57 Gas1 N-Pentane Composition (%Mole)
30 Gas1_HEXANE_N 59 Gas1 N-Hexane Composition (%Mole)
31 Gas1_HV_R 61 Gas11 Gross Heating Value (BTU/SCF)
32 Gas1_SG_R 63 Gas1 Specific Gravitiy
33 Gas1_TOTAL 65 Gas11 Total Composition (%Mole)
34 GC_TOTAL 67 Gas11 GC Total Composition (%Mole)
35 RUN1_ENGMM_TH 69 Gas1 Energy This Hour (MMBTU)
36 RUN1_ENGMM_LH 71 Gas1 Energy Last Day(MMBTU)
37 RUN1_ENGMM_TD 73 Gas1 Energy This Day(MMBTU)
38 RUN1_ENGMM_LD 75 Gas1 Energy Last Day (MMBTU)
39 RUN1_ENGMM_TM 77 Gas1 Energy This Month(MMBTU)
40 RUN1_ENGMM_LM 79 Gas1 Energy Last Month(MMBTU)
41 RUN1_PRS_ADJ 81 Run1 Press Adjust
42 RUN1_TAP_LOC 83 Run1 Press. Tap Loc
43 RUN1_PRS_BASE 85 Run1 Press Base
44 RUN1_TMP_BASE 87 Run1 Temp Base
65 RUN1_MSCFD_AVGD 129 Flow Rate Reading MSCFD This Day
66 RUN1_FLOW_MSCFH 131 Flow Rate Reading MSCFH
69 RUN1_MSCFD_AVGH 137 Flow Rate Reading MSCFD This Hour
74 RUN1_DP_CUTOFF 147 Run1 DP Cut Off
85 RUN1_MSCFD_AVGH 169 Flow Rate Reading MSCFD This Hour
86 RUN1_MSCFD_AVGD 171 Flow Rate Reading MSCFH This Day
87 RUN1_FLOW_MSCFD 173 Flow Rate Reading MSCFD
88 RUN1_FLOW_MSCFH 175 Flow Rate Reading MSCFH
89 RUN1_VOLM_TOTALIZER 177 Run1 Vol Totalizer
90 RUN1_ENGMM_TOTALIZER 179 Run1 Energy Totalizer
91 RUN1_PRS_PSIG 201 Pressure Reading (Psig)
92 RUN1_TMP_DEGF 203 Temperature Reading (Deg.F)
93 RUN1_DP_INH2O 205 Differential Pressure Reading (inH2O)
94 RUN1_FLOW_MSCFD 207 Flow Rate Reading (MMSCFD)
95 RUN1_VOLM_TH 209 Volume This Hour (MMSCF)
96 RUN1_VOLM_LH 211 Volume Last Hour(MMSCF)
97 RUN1_VOLM_TD 213 Volume This Day(MMSCF)
98 RUN1_VOLM_LD 215 Volume Last Day (MMSCF)
99 RUN1_VOLM_TM 217 Volume This Month(MMSCF)
100 RUN1_VOLM_LM 219 Volume Last Month(MMSCF)
101 RUN1_DIAM_ORIF_M 221 Inside Diameter Orifice (inch)
102 RUN1_DIAM_PIPE_M 223 Inside Diameter Pipe (inch)
103 RUN1_PRS_ZERO 225 Pressure Transmitter Zero Cal. (Psig)
104 RUN1_PRS_SPAN 227 Pressure Transmitter Span Cal. (Psig)
105 RUN1_TMP_ZERO 229 Temperature Transmitter Zero Cal. (Deg.F)
106 RUN1_TMP_SPAN 231 Temperature Transmitter Span Cal. (Deg.F)
107 RUN1_DP_ZERO 233 Diff. Pressure Transmitter Zero Cal. (inH2O)
108 RUN1_DP_SPAN 235 Diff. Pressure Transmitter Span Cal. (inH2O)
109 RUN1_ENG_MMBTUD 237 Energy Rate Reading (MMBTUD)
110 RUN1_PRS_UPSTREAM 239 Pressure upstream (psig)
111 Gas1_METHANE 241 Gas1 Methane Composition (%Mole)
112 Gas1_NITROGEN 243 Gas1 Nitrogen Composition (%Mole)
113 Gas1_CO2 245 Gas1 CO2 Composition (%Mole)
114 Gas1_ETHANE 247 Gas1 Ethane Composition (%Mole)
115 Gas1_PROPANE 249 Gas1 Propane Composition (%Mole)
116 Gas1_BUTANE_I 251 Gas1 I-Butane Composition (%Mole)
117 Gas1_BUTANE_N 253 Gas1 N-Butane Composition (%Mole)
118 Gas1_PENTANE_I 255 Gas1 I-Pentane Composition (%Mole)
119 Gas1_PENTANE_N 257 Gas1 N-Pentane Composition (%Mole)
120 Gas1_HEXANE_N 259 Gas1 N-Hexane Composition (%Mole)
121 Gas1_HV_R 261 Gas11 Gross Heating Value (BTU/SCF)
122 Gas1_SG_R 263 Gas1 Specific Gravitiy
123 Gas1_TOTAL 265 Gas11 Total Composition (%Mole)
124 GC_TOTAL 267 Gas11 GC Total Composition (%Mole)
125 RUN1_ENGMM_TH 269 Gas1 Energy This Hour (MMBTU)
126 RUN1_ENGMM_LH 271 Gas1 Energy Last Day(MMBTU)
127 RUN1_ENGMM_TD 273 Gas1 Energy This Day(MMBTU)
128 RUN1_ENGMM_LD 275 Gas1 Energy Last Day (MMBTU)
129 RUN1_ENGMM_TM 277 Gas1 Energy This Month(MMBTU)
130 RUN1_ENGMM_LM 279 Gas1 Energy Last Month(MMBTU)
131 RUN1_PRS_ADJ 281 Run1 Press Adjust
132 RUN1_TAP_LOC 283 Run1 Press. Tap Loc
133 RUN1_PRS_BASE 285 Run1 Press Base
134 RUN1_TMP_BASE 287 Run1 Temp Base
135 RUN1_MSCFD_AVGD 329 Flow Rate Reading MSCFD This Day
136 RUN1_FLOW_MSCFH 331 Flow Rate Reading MSCFH
137 RUN1_MSCFD_AVGH 337 Flow Rate Reading MSCFD This Hour
138 RUN1_DP_CUTOFF 347 Run1 DP Cut Off
139 RUN1_MSCFD_AVGH 369 Flow Rate Reading MSCFD This Hour
140 RUN1_MSCFD_AVGD 371 Flow Rate Reading MSCFH This Day
141 RUN1_FLOW_MSCFD 373 Flow Rate Reading MSCFD
142 RUN1_FLOW_MSCFH 375 Flow Rate Reading MSCFH
143 RUN1_VOLM_TOTALIZER 377 Run1 Vol Totalizer
144 RUN1_ENGMM_TOTALIZER 379 Run1 Energy Totalizer