Kaizen Sheet company /

Location MM / YY SL No
Productivity Quality Delivery Cost Safety Material Energy Morale Vizag 8/11/2018

Kaizen Title : jd 619 conveyor bag filter vent fan bottom Casing moc modication. Implemented Area: RMH
Implemented By:

Result/Benefit: Vent fan causing bottom part


corrosion problem will be avoided .and will in
Problem/Present Status: Before Improvement: good condition with out tripping.
a. Qualitative

Jd 619 conveyor bag filter vant fan was not in condition from long back . As seen in
pic the bottom portion of the vent fan was corroded and not in condition for b. Quantitative
continuous running . MODIFICATION :-As the ( Pictorial Representation)
area was continuously filled with water during rain season there is chance of
corrosion of bottom part again.so we have modified bottom part of causing with ss
plate and positioned it in location.Present it was running in good contion.

Real Root Cause Identification: After Improvement:

VENT FAN BOTTOM CASING MOC CHANGED FROM MS TO SS Standardization


REGULAR CORROSION OF FAN BOTTOM CASING DUE TO WATER STAGNATION


NO PROPER DRAIN AVALIBLE FOR RAIN WATER PASSAGE.


Root cause Howmany places this kaizen can been deployed


Idea to eliminate root cause horizontally & Total benefits:
Countermeasure

Team/Individual Name : 1.J.SRINIVAS (TEC) 2. G.SRINIVASA RAO(ASST.MAN) Approved by Name Signature


sectionHead
kaizen Champion
Finance head