Professional Documents
Culture Documents
FEATURES
- SMALL FOOTPRINT
- RUGGED DESIGN
- TOTAL THERMAL
BREAK CONSTRUCTION
- ZINC/ ALUMINUM ALLOY
COATED STEEL PANEL
- CORROSION RESISTANT
PRECOATED COIL FIN
- BUILT FOR EASY SERVICING
TABLE OF CONTENTS
Page No
NOMENCLATURE...................................................................................................................................................................................... 2
FEATURES ............................................................................................................................................................................................... 3
SPECIFICATION ....................................................................................................................................................................................... 5
PHYSICAL DIMENSION ............................................................................................................................................................................. 6
UNIT SHIPPING WEIGHT........................................................................................................................................................................... 8
NOMENCLATURE
The following gives a sample nomenclature of Dunham-Bush compact air-handling units.
DC 200 - MX - L
COMPONENTS
Discharge Plenum
Motorized Valve- Optional Mixing Box Section
-Perforated Liner
- Aluminum Airfoil
Damper
SANDWICH PANEL
Sandwich panel construction has smooth
inner surface for easy and effective
cleaning to reduce risk of dirt and
bacteria accumulation, there is no
erosion of internal insulation material to
contaminate the air stream. The PVC
strip in between inner and outer layer
forms a thermal-break to minimize heat-
transfer.
HIGH-EFFICIENCY,
HEAVY DUTY, NON-
OVERLOADING
BACKWARD
INCLINED FAN
All fans are of heavy duty non-
Backward Inclined Fan
overloading type, suitable for high static operation
up to maximum 6.75”w.g., all fan performance data
are AMCA (Air Movement and Control
Association, USA) certified and licensed to bear
AMCA seal. All fans are statically and dynamically
balanced to ISO 1940 and AMCA 204/3- G4.0
standard.
MODEL: DC-RF/MX
MODEL DC RF/MX-040 RF/MX-060 RF/MX-080 RF/MX-100 RF/MX-150 RF/MX-200 RF/MX-250 RF/MX-300
FAN (SUPPLY)
A ) VOLUME CFM/CMM 1415/40 2120/60 2825/80 3530/100 5295/150 7065/200 8830/250 10595/300
B.) FAN TYPE DIDW BACKWARD INCLINED
C.) MOTOR(MAX) HP 7.5 7.5 7.5 10.0 15.0 20.0 30.0 40.0
(TEFC,IP55)
FAN (RETURN)
COOLING COIL
A.) TUBE HEIGHT X FIN LENGTH 24T X 14FL 26T X 18FL 34T X 18FL 38T X 20FL 40T X 27FL 40T X 36FL 44T X 42FL 44T X 50FL
HEATING COIL
A.) TUBE HEIGHT X FIN LENGTH 24T X 14FL 26T X 18FL 34T X 18FL 38T X 20FL 40T X 27FL 40T X 36FL 44T X 42FL 44T X 50FL
FILTERS
HUMIDIFIER-EVAPORATIVE TYPE(OPTIONAL)
MODEL: DC-HR
MODEL DC HR-040 HR-060 HR-080 HR-100 HR-150 HR-200 HR-250 HR-300
FAN (SUPPLY)
A ) VOLUME CFM/CMM 1415/40 2120/60 2825/80 3530/100 5295/150 7065/200 8830/250 10595/300
FAN (RETURN)
COOLING COIL
A.) TUBE HEIGHT X FIN LENGTH 24T X 14FL 26T X 18FL 34T X 18FL 38T X 20FL 40T X 27FL 40T X 36FL 44T X 42FL 44T X 50FL
HEATING COIL
A.) TUBE HEIGHT X FIN LENGTH 24T X 14FL 26T X 18FL 34T X 18FL 38T X 20FL 40T X 27FL 40T X 36FL 44T X 42FL 44T X 50FL
FILTERS
HUMIDIFIER-EVAPORATIVE TYPE(OPTIONAL)
A.) CAPACITY LBS/HR 6.5 10.0 13.5 16.0 25.0 33.0 41.0 50.0
B.) WATER FLOW GPM 0.13 0.26 0.26 0.26 0.50 0.50 0.50 0.50
RATE
A.) VOLUME CFM 355 530 705 885 1325 1765 2205 2650
MODEL : DC-MX
MODEL W W1 W2 H D
(DC-MX)
40 90 5/8 65 25 5/8 75 3/8 25 5/8
60 91 5/8 66 25 5/8 75 3/8 27 5/8
80 94 66 3/8 27 5/8 80 1/4 27 5/8
100 96 68 3/8 27 5/8 80 1/4 30 3/4
150 98 68 3/8 29 5/8 84 37
200 100 3/4 69 1/8 31 5/8 84 46 1/2
250 103 70 1/4 32 3/4 84 1/2 53 1/2
300 110 3/8 74 7/8 35 1/2 84 1/2 61 1/2
MODEL : DC-RF
MODEL W W1 W2 H D
(DC-RF)
40 130 65 65 75 3/8 25 5/8
60 132 66 66 75 3/8 27 5/8
80 132 3/4 66 3/8 66 3/8 80 1/4 27 5/8
100 136 3/4 68 3/8 68 3/8 80 1/4 30 3/4
150 136 3/4 68 3/8 68 3/8 84 37
200 138 1/4 69 1/8 69 1/8 84 46 1/2
250 140 1/2 70 1/4 70 1/4 84 1/2 53 1/2
300 149 3/4 74 7/8 74 7/8 84 1/2 61 1/2
MODEL : DC-HR
MODEL (DC-HR) W W1 W2 H H1 D
Supply Air Return Air Total Supply Air Return Air Total Supply Air Return Air Heat-Rec. Total
Section Section Section Section Section Section Section
40 616 198 814 616 517 1133 616 517 308 1441
60 660 220 880 660 539 1199 660 539 319 1518
80 836 242 1078 836 605 1441 836 605 319 1760
100 1001 253 1254 1001 660 1661 1001 660 319 1980
150 1100 297 1397 1100 748 1848 1100 748 330 2178
200 1210 352 1562 1210 836 2046 1210 836 352 2398
250 1397 418 1815 1397 968 2365 1397 968 363 2728
300 1639 462 2101 1637 1067 2706 1637 1067 385 3091
NOTES: 1.) EXCLUDES COIL.
2.) BASED ON MAXIMUM MOTOR FRAME SIZE.