Design of Trombone Cooler for Gasses

Temperatures

Hot Fluid Cold Fluid Differences


Highest Temp 200 C 80 C 120 C
Lowest Temp 100 C 30 C 70 C
Difference 100 C 50 C 50 C

𝟏𝟐𝟎−𝟕𝟎
𝑳𝑴𝑻𝑫 = 𝟏𝟐𝟎 = 90 C
𝐥𝐧( )
𝟕𝟎
100 50
R= =2 S= = 0.3
50 170

From graph we find value of Ft


Ft = 0.95 Corrected LMTD = 86 C
Heat duty to be removed =Q = 3.5 x 105 Kj/Hr
3.5∗105
Mass flow rate of water required = = 1670 Kj/Hr
4.19∗86
Hot Fluid at Tube Side
Taking 3-inch pipe of schedule 40
At = 0.00476 m^2
L = 2.4 m
Internal Diameter = 0.077 m
Outer Diameter =0.089 m
G = 3643/0.0047 = 7.8x105 Kj/Hr
µ = 2 x 10^-5 Pa. s
Re = 5.8 x 105
From graph
Jh = 0.003
K = 160
By using equation
Hi = 0.13
Hio = 0.13*0.077/0.089 = 0.112
Shell Side Calculations
G = 1670/2*2.4 = 348
Taverage = 55 C
µ = 0.00102 Kg/ms
Re = 4G/µ = 6 x 10 ^ 6
From equation

Ho = 1020
Uc = 1020*0.112/(1020+0.112)= 102

Heat Transfer Area = Q/U Tlmtd


A = 38 m2
Number of Tubes Required
A/AtL = 38/ 0.716 = 53 tubes