b= 400mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 600mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø16
ØMAIN BAR= Ø25
SLO= 100mm.
SLV= 150mm.
Nb= 4-legs // to width 2-legs // to width
Nd= 2-legs // to depth 0-legs // to depth
cc= 40mm.
Along Lv:
SLV= 150mm. OK
3L -Ø16 Cross
Ties // to Depth
b= 450mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 650mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø16
ØMAIN BAR= Ø25
SLO= 100mm.
SLV= 150mm.
Nb= 3-legs // to width 1-legs // to width
Nd= 2-legs // to depth 0-legs // to depth
cc= 40mm.
Along Lv:
SLV= 150mm. OK
3L -Ø16 Cross
Ties // to Depth
b= 450mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 650mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø16
ØMAIN BAR= Ø25
SLO= 100mm.
SLV= 150mm.
Nb= 3-legs // to width 1-legs // to width
Nd= 2-legs // to depth 0-legs // to depth
cc= 40mm.
Along Lv:
SLV= 150mm. OK
3L -Ø16 Cross
Ties // to Depth
b= 350mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 450mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø16
ØMAIN BAR= Ø25
SLO= 85mm.
SLV= 150mm.
Nb= 3-legs // to width 1-legs // to width
Nd= 3-legs // to depth 1-legs // to depth
cc= 40mm.
Along Lv:
SLV= 150mm. OK
3L -Ø16 Cross
Ties // to Depth
b= 400mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 550mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø16
ØMAIN BAR= Ø25
SLO= 100mm.
SLV= 150mm.
Nb= 3-legs // to width 1-legs // to width
Nd= 3-legs // to depth 1-legs // to depth
cc= 40mm.
Along Lv:
SLV= 150mm. OK
3L -Ø16 Cross
Ties // to Depth
b= 400mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 550mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø16
ØMAIN BAR= Ø25
SLO= 100mm.
SLV= 150mm.
Nb= 3-legs // to width 1-legs // to width
Nd= 3-legs // to depth 1-legs // to depth
cc= 40mm.
Along Lv:
SLV= 150mm. OK
3L -Ø16 Cross
Ties // to Depth
b= 300mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 300mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 28MPa.
fyt= 414MPa.
ØTIES= Ø12
ØMAIN BAR= Ø16
SLO= 75mm.
SLV= 150mm.
Nb= 4-legs // to width 2-legs // to width
Nd= 4-legs // to depth 2-legs // to depth
cc= 40mm.
Along Lv:
SLV= 150mm. OK
3L -Ø16 Cross
Ties // to Depth
b= 350mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 350mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø12
ØMAIN BAR= Ø25
SLO= 85mm.
SLV= 150mm.
Nb= 4-legs // to width 2-legs // to width
Nd= 4-legs // to depth 2-legs // to depth
cc= 40mm.
Along Lv:
SLV= 150mm. OK
3L -Ø16 Cross
Ties // to Depth
b= 350mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 350mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø12
ØMAIN BAR= Ø25
SLO= 85mm.
SLV= 150mm.
Nb= 4-legs // to width 2-legs // to width
Nd= 4-legs // to depth 2-legs // to depth
cc= 40mm.
Along Lv:
SLV= 150mm. OK
3L -Ø16 Cross
Ties // to Depth