Rectangular Column Transverse Reinforcement

A) Ash = 0.3 (sbcf'c/fyt)[(Ag/Ach)-1]


B) Ash = 0.09 (sbcf'c/fyt)
C) Ash = 0.2sbckfkn (Pu/Achfyt)

b= 400mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 600mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø16
ØMAIN BAR= Ø25
SLO= 100mm.
SLV= 150mm.
Nb= 4-legs // to width 2-legs // to width
Nd= 2-legs // to depth 0-legs // to depth
cc= 40mm.

bc= 320 Ac= 166400 0.3f'cAg= 2484 kf= 1


dc= 520 Ag= 240000 nl= 8 kn= 1.333333
Min. Tot. V.B.= 8

Along Lo Lj, confinement:


hxmax= 300 OK
smax= 100 OK

Case A Case B Case C


Direction
Ash DCR Remarks Ash DCR Remarks Ash DCR Remarks
Parallel to width 575.00 0.7150 OK 390.00 0.4849 OK N/A N/A OK
Parallel to depth 353.85 0.8799 OK 240.00 0.5968 OK N/A N/A OK

Along Lv:
SLV= 150mm. OK

1-Ø16mm Closed Hoop

3L -Ø16 Cross
Ties // to Depth

2L-Ø16 Cross Ties // to Width


Rectangular Column Transverse Reinforcement
A) Ash = 0.3 (sbcf'c/fyt)[(Ag/Ach)-1]
B) Ash = 0.09 (sbcf'c/fyt)
C) Ash = 0.2sbckfkn (Pu/Achfyt)

b= 450mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 650mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø16
ØMAIN BAR= Ø25
SLO= 100mm.
SLV= 150mm.
Nb= 3-legs // to width 1-legs // to width
Nd= 2-legs // to depth 0-legs // to depth
cc= 40mm.

bc= 370 Ac= 210900 0.3f'cAg= 3027.375 kf= 1


dc= 570 Ag= 292500 nl= 6 kn= 1.5
Min. Tot. V.B.= 6

Along Lo Lj, confinement:


hxmax= 300 OK
smax= 112.5 OK

Case A Case B Case C


Direction
Ash DCR Remarks Ash DCR Remarks Ash DCR Remarks
Parallel to width 551.35 0.9141 OK 427.50 0.7087 OK N/A N/A OK
Parallel to depth 357.89 0.8900 OK 277.50 0.6901 OK N/A N/A OK

Along Lv:
SLV= 150mm. OK

1-Ø16mm Closed Hoop

3L -Ø16 Cross
Ties // to Depth

1L-Ø16 Cross Ties // to Width


Rectangular Column Transverse Reinforcement
A) Ash = 0.3 (sbcf'c/fyt)[(Ag/Ach)-1]
B) Ash = 0.09 (sbcf'c/fyt)
C) Ash = 0.2sbckfkn (Pu/Achfyt)

b= 450mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 650mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø16
ØMAIN BAR= Ø25
SLO= 100mm.
SLV= 150mm.
Nb= 3-legs // to width 1-legs // to width
Nd= 2-legs // to depth 0-legs // to depth
cc= 40mm.

bc= 370 Ac= 210900 0.3f'cAg= 3027.375 kf= 1


dc= 570 Ag= 292500 nl= 6 kn= 1.5
Min. Tot. V.B.= 6

Along Lo Lj, confinement:


hxmax= 300 OK
smax= 112.5 OK

Case A Case B Case C


Direction
Ash DCR Remarks Ash DCR Remarks Ash DCR Remarks
Parallel to width 551.35 0.9141 OK 427.50 0.7087 OK N/A N/A OK
Parallel to depth 357.89 0.8900 OK 277.50 0.6901 OK N/A N/A OK

Along Lv:
SLV= 150mm. OK

1-Ø16mm Closed Hoop

3L -Ø16 Cross
Ties // to Depth

1L-Ø16 Cross Ties // to Width


Rectangular Column Transverse Reinforcement
A) Ash = 0.3 (sbcf'c/fyt)[(Ag/Ach)-1]
B) Ash = 0.09 (sbcf'c/fyt)
C) Ash = 0.2sbckfkn (Pu/Achfyt)

b= 350mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 450mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø16
ØMAIN BAR= Ø25
SLO= 85mm.
SLV= 150mm.
Nb= 3-legs // to width 1-legs // to width
Nd= 3-legs // to depth 1-legs // to depth
cc= 40mm.

bc= 270 Ac= 99900 0.3f'cAg= 1630.125 kf= 1


dc= 370 Ag= 157500 nl= 8 kn= 1.333333
Min. Tot. V.B.= 8

Along Lo Lj, confinement:


hxmax= 300 OK
smax= 87.5 OK

Case A Case B Case C


Direction
Ash DCR Remarks Ash DCR Remarks Ash DCR Remarks
Parallel to width 453.33 0.7516 OK 235.88 0.3910 OK N/A N/A OK
Parallel to depth 330.81 0.5484 OK 172.13 0.2854 OK N/A N/A OK

Along Lv:
SLV= 150mm. OK

1-Ø16mm Closed Hoop

3L -Ø16 Cross
Ties // to Depth

1L-Ø16 Cross Ties // to Width


Rectangular Column Transverse Reinforcement
A) Ash = 0.3 (sbcf'c/fyt)[(Ag/Ach)-1]
B) Ash = 0.09 (sbcf'c/fyt)
C) Ash = 0.2sbckfkn (Pu/Achfyt)

b= 400mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 550mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø16
ØMAIN BAR= Ø25
SLO= 100mm.
SLV= 150mm.
Nb= 3-legs // to width 1-legs // to width
Nd= 3-legs // to depth 1-legs // to depth
cc= 40mm.

bc= 320 Ac= 150400 0.3f'cAg= 2277 kf= 1


dc= 470 Ag= 220000 nl= 8 kn= 1.333333
Min. Tot. V.B.= 8

Along Lo Lj, confinement:


hxmax= 300 OK
smax= 100 OK

Case A Case B Case C


Direction
Ash DCR Remarks Ash DCR Remarks Ash DCR Remarks
Parallel to width 543.75 0.9015 OK 352.50 0.5844 OK N/A N/A OK
Parallel to depth 370.21 0.6138 OK 240.00 0.3979 OK N/A N/A OK

Along Lv:
SLV= 150mm. OK

1-Ø16mm Closed Hoop

3L -Ø16 Cross
Ties // to Depth

1L-Ø16 Cross Ties // to Width


Rectangular Column Transverse Reinforcement
A) Ash = 0.3 (sbcf'c/fyt)[(Ag/Ach)-1]
B) Ash = 0.09 (sbcf'c/fyt)
C) Ash = 0.2sbckfkn (Pu/Achfyt)

b= 400mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 550mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø16
ØMAIN BAR= Ø25
SLO= 100mm.
SLV= 150mm.
Nb= 3-legs // to width 1-legs // to width
Nd= 3-legs // to depth 1-legs // to depth
cc= 40mm.

bc= 320 Ac= 150400 0.3f'cAg= 2277 kf= 1


dc= 470 Ag= 220000 nl= 8 kn= 1.333333
Min. Tot. V.B.= 8

Along Lo Lj, confinement:


hxmax= 300 OK
smax= 100 OK

Case A Case B Case C


Direction
Ash DCR Remarks Ash DCR Remarks Ash DCR Remarks
Parallel to width 543.75 0.9015 OK 352.50 0.5844 OK N/A N/A OK
Parallel to depth 370.21 0.6138 OK 240.00 0.3979 OK N/A N/A OK

Along Lv:
SLV= 150mm. OK

1-Ø16mm Closed Hoop

3L -Ø16 Cross
Ties // to Depth

1L-Ø16 Cross Ties // to Width


Rectangular Column Transverse Reinforcement
A) Ash = 0.3 (sbcf'c/fyt)[(Ag/Ach)-1]
B) Ash = 0.09 (sbcf'c/fyt)
C) Ash = 0.2sbckfkn (Pu/Achfyt)

b= 300mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 300mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 28MPa.
fyt= 414MPa.
ØTIES= Ø12
ØMAIN BAR= Ø16
SLO= 75mm.
SLV= 150mm.
Nb= 4-legs // to width 2-legs // to width
Nd= 4-legs // to depth 2-legs // to depth
cc= 40mm.

bc= 220 Ac= 48400 0.3f'cAg= 756 kf= 1


dc= 220 Ag= 90000 nl= 12 kn= 1.2
Min. Tot. V.B.= 12

Along Lo Lj, confinement:


hxmax= 300 OK
smax= 75 OK

Case A Case B Case C


Direction
Ash DCR Remarks Ash DCR Remarks Ash DCR Remarks
Parallel to width 287.75 0.6361 OK 100.43 0.2220 OK N/A N/A OK
Parallel to depth 287.75 0.6361 OK 100.43 0.2220 OK N/A N/A OK

Along Lv:
SLV= 150mm. OK

1-Ø12mm Closed Hoop

3L -Ø16 Cross
Ties // to Depth

2L-Ø12 Cross Ties // to Width


Rectangular Column Transverse Reinforcement
A) Ash = 0.3 (sbcf'c/fyt)[(Ag/Ach)-1]
B) Ash = 0.09 (sbcf'c/fyt)
C) Ash = 0.2sbckfkn (Pu/Achfyt)

b= 350mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 350mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø12
ØMAIN BAR= Ø25
SLO= 85mm.
SLV= 150mm.
Nb= 4-legs // to width 2-legs // to width
Nd= 4-legs // to depth 2-legs // to depth
cc= 40mm.

bc= 270 Ac= 72900 0.3f'cAg= 1267.875 kf= 1


dc= 270 Ag= 122500 nl= 12 kn= 1.2
Min. Tot. V.B.= 12

Along Lo Lj, confinement:


hxmax= 300 OK
smax= 87.5 OK

Case A Case B Case C


Direction
Ash DCR Remarks Ash DCR Remarks Ash DCR Remarks
Parallel to width 390.37 0.8629 OK 172.13 0.3805 OK N/A N/A OK
Parallel to depth 390.37 0.8629 OK 172.13 0.3805 OK N/A N/A OK

Along Lv:
SLV= 150mm. OK

1-Ø12mm Closed Hoop

3L -Ø16 Cross
Ties // to Depth

2L-Ø12 Cross Ties // to Width


Rectangular Column Transverse Reinforcement
A) Ash = 0.3 (sbcf'c/fyt)[(Ag/Ach)-1]
B) Ash = 0.09 (sbcf'c/fyt)
C) Ash = 0.2sbckfkn (Pu/Achfyt)

b= 350mm. Note: Use at least 10mm ties for VB=32mm and at least 12mm for VB=36mm or larger
d= 350mm. If Case C is a positive value, All Vert. Reinforcements shall have cross ties or lateral supports
Pu= 0.00kN.
f'c= 35MPa.
fyt= 414MPa.
ØTIES= Ø12
ØMAIN BAR= Ø25
SLO= 85mm.
SLV= 150mm.
Nb= 4-legs // to width 2-legs // to width
Nd= 4-legs // to depth 2-legs // to depth
cc= 40mm.

bc= 270 Ac= 72900 0.3f'cAg= 1267.875 kf= 1


dc= 270 Ag= 122500 nl= 12 kn= 1.2
Min. Tot. V.B.= 12

Along Lo Lj, confinement:


hxmax= 300 OK
smax= 87.5 OK

Case A Case B Case C


Direction
Ash DCR Remarks Ash DCR Remarks Ash DCR Remarks
Parallel to width 390.37 0.8629 OK 172.13 0.3805 OK N/A N/A OK
Parallel to depth 390.37 0.8629 OK 172.13 0.3805 OK N/A N/A OK

Along Lv:
SLV= 150mm. OK

1-Ø12mm Closed Hoop

3L -Ø16 Cross
Ties // to Depth

2L-Ø12 Cross Ties // to Width