1
Given Data:
Effective Span= 63 ft
Effective Width= 3o ft
Live Load= HS20
Concrete Strength (Cylindrical Test) f'c =5000 psi (35 MPa)
Steel a- Grade 40 for Deck Slab fy = 40,000 psi (330 MPa)
b- Grade 60 for Girders fy =60,000 psi (414 MPa)
Dead load :
2
I : Impact factor
3
Design Deck slab according
l
4
d required for slab :
Use steel ɸ 5/8 in and concrete cover 1 in and take top layer 1 in
5
Design of Interior Girders :
Design as T section : assume h for web = 40 in (1.00m)
Dead load :
Live load :
6
Load for back and middle wheel=1.40*16000=22400 lb
7
To calculation max. shear force due to live load, max. shear force
found under back wheel after enter the truck across bridge .The
back wheel without increase while the middle and front wheel
load multiply by factor 1.40
8
Determination of Girder Cross Section Dimensions :
Total h = 48 in
9
Stress calculation :
11
Web Shear Reinforcement
11
12
Max. space between stirrup = d/2 = 40.625/2 = 20 in
Vs =
13
14
15