Professional Documents
Culture Documents
Sachpazis - FLAT SLAB DESIGN TO BS8110-PART 1-1997 PDF
Sachpazis - FLAT SLAB DESIGN TO BS8110-PART 1-1997 PDF
Slab geometry
Span of slab in x-direction; Spanx = 7200 mm
Span of slab in y-direction; Spany = 7200 mm
Column dimension in x-direction; lx = 400 mm
Column dimension in y-direction; ly = 400 mm
External column dimension in x-direction; lx1 = 250 mm
External column dimension in y-direction; ly1 = 250 mm
Edge dimension in x-direction; ex = lx1 / 2 = 125 mm
Edge dimension in y-direction; ey = ly1 / 2 = 125 mm
Effective span of internal bay in x direction; Lx = Spanx – lx = 6800 mm
Effective span of internal bay in y direction; Ly = Spany – ly = 6800 mm
Effective span of end bay in x direction; Lx1 = Spanx – lx / 2 = 7000 mm
Effective span of end bay in y direction; Ly1 = Spany – ly / 2 = 7000 mm
ex A B C
Span x Span x
ey l y1
1
lx1
lx lx
y
an
Sp
2 ly
y
an
Sp
3 ly
Slab details
Depth of slab; h = 250 mm
1
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
2
Characteristic strength of concrete; fcu = 35 N/mm
2
Characteristic strength of reinforcement; fy = 500 N/mm
2
Characteristic strength of shear reinforcement; fyv = 500 N/mm
Material safety factor; γm = 1.15
Cover to bottom reinforcement; c = 20 mm
Cover to top reinforcement; c’ = 20 mm
Loading details
2
Characteristic dead load; Gk = 7.000 kN/m
2
Characteristic imposed load; Qk = 5.000 kN/m
Dead load factor; γG = 1.4
Imposed load factor; γQ = 1.6
2
Total ultimate load; Nult = (Gk × γG) + (Qk × γQ) = 17.800 kN/m
Moment redistribution ratio; βb = 1.0
Ratio of support moments to span moments; i = 1.0
SAGGING MOMENTS
End bay A-B
Effective span; L = 7000 mm
Depth of reinforcement; d = 200 mm
2 2
Midspan moment; m = (Nult × L ) / (2 × (1 + √(1 + i)) ) = 74.823 kNm/m
Support moment; m’ = i × m = 74.823 kNm/m
Design reinforcement
2
Lever arm; K’ = 0.402 × (βb – 0.4) – 0.18 × (βb – 0.4) = 0.176
2
K = m / (d × fcu) = 0.053
Compression reinforcement is not required
z = min((0.5 + √(0.25 – (K / 0.9))), 0.95) × d = 187.3 mm
2
Area of reinforcement designed; As_des = m / (z × fy / γm) = 919 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 × h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 919 mm /m
Provide 20 dia bars @ 150 centres
2 2
Area of reinforcement provided; As_prov = π × D / (4 × s) = 2094 mm /m
PASS - Span reinforcement is OK
Check deflection
2
Design service stress; fs = 2 × fy × As_req / (3 × As_prov × βb) = 146 N/mm
2 2 2
Modification factor; k1 = min(0.55+(477N/mm -fs)/(120×(0.9N/mm +(m/d ))),2) = 1.545
Allowable span to depth ratio; 0.9 × 26 × k1 = 36.151
Actual span to depth ratio; L / d = 35.000
2
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
3
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
Internal column C3
Consider the reinforcement concentrated in half width strip over the support
Depth of reinforcement; d’ = 200 mm
Support moment; m’ = 2 × i × m = 102.884 kNm/m
2
Lever arm; K’ = 0.402 × (βb – 0.4) – 0.18 × (βb – 0.4) = 0.176
2
K = m’ / (d’ × fcu) = 0.073
Compression reinforcement is not required
z = min((0.5 + √(0.25 – (K / 0.9))), 0.95) × d’ = 182.1 mm
2
Area of reinforcement required; As_des = m’ / (z × fy / γm) = 1300 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 × h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 1300 mm /m
Provide 20 dia bars @ 200 centres
2 2
Area of reinforcement provided; As_prov = π × D / (4 × s) = 1571 mm /m
PASS - Support reinforcement is OK
4
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
2
Lever arm; K’ = 0.402 × (βb – 0.4) – 0.18 × (βb – 0.4) = 0.176
2
K = m’ / (d’ × fcu) = 0.078
Compression reinforcement is not required
z = min((0.5 + √(0.25 – (K / 0.9))), 0.95) × d’ = 180.9 mm
2
Area of reinforcement required; As_des = m’ / (z × fy / γm) = 1383 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 × h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 1383 mm /m
Provide 20 dia bars @ 200 centres
2 2
Area of reinforcement provided; As_prov = π × D / (4 × s) = 1571 mm /m
PASS - Support reinforcement is OK
Corner column A1
Depth of reinforcement; d’ = 206 mm
Total load on column; S = ((Spanx / 2) + ex) × ((Spany / 2) + ey) × Nult = 247 kN
2
Area of column head; A = lx × ly1 = 0.100 m
1/3
Support moment; m’ = S × (1 – (Nult × A / S) ) / 2 = 99.639 kNm/m
2
Lever arm; K’ = 0.402 × (βb – 0.4) – 0.18 × (βb – 0.4) = 0.176
2
K = m’ / (d’ × fcu) = 0.067
Compression reinforcement is not required
z = min((0.5 + √(0.25 – (K / 0.9))), 0.95) × d’ = 189.3 mm
2
Area of reinforcement required; As_des = m’ / (z × fy / γm) = 1211 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 × h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 1211 mm /m
Provide 16 dia bars @ 150 centres
2 2
Area of reinforcement provided; As_prov = π × D / (4 × s) = 1340 mm /m
PASS - Support reinforcement is OK
Edge column A2, A3
Depth of reinforcement; d’ = 202 mm
Total load on column; S = Spanx × (Spany / 2 + ey) × Nult = 477 kN
2
Area of column head; A = lx1 × ly = 0.100 m
1/3
Support moment; m’ = S × (1 – (Nult × A / S) ) / 5.14 = 78.476 kNm/m
2
Lever arm; K’ = 0.402 × (βb – 0.4) – 0.18 × (βb – 0.4) = 0.176
2
K = m’ / (d’ × fcu) = 0.055
Compression reinforcement is not required
z = min((0.5 + √(0.25 – (K / 0.9))), 0.95) × d’ = 188.8 mm
2
Area of reinforcement required; As_des = m’ / (z × fy / γm) = 956 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 × h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 956 mm /m
Provide 16 dia bars @ 175 centres
2 2
Area of reinforcement provided; As_prov = π × D / (4 × s) = 1149 mm /m
5
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
SAGGING MOMENTS
End bay 1-2
Effective span; L = 7000 mm
Depth of reinforcement; d = 220 mm
2 2
Midspan moment; m = (Nult × L ) / (2 × (1 + √(1 + i)) ) = 74.823 kNm/m
Support moment; m’ = i × m = 74.823 kNm/m
Design reinforcement
2
Lever arm; K’ = 0.402 × (βb – 0.4) – 0.18 × (βb – 0.4) = 0.176
2
K = m / (d × fcu) = 0.044
Compression reinforcement is not required
z = min((0.5 + √(0.25 – (K / 0.9))), 0.95) × d = 208.6 mm
2
Area of reinforcement designed; As_des = m / (z × fy / γm) = 825 mm /m
2
Minimum area of reinforcement required; As_min = 0.0013 × h = 325 mm /m
2
Area of reinforcement required; As_req = max(As_des, As_min) = 825 mm /m
Provide 20 dia bars @ 200 centres
2 2
Area of reinforcement provided; As_prov = π × D / (4 × s) = 1571 mm /m
PASS - Span reinforcement is OK
Check deflection
2
Design service stress; fs = 2 × fy × As_req / (3 × As_prov × βb) = 175 N/mm
2 2 2
Modification factor; k1 = min(0.55+(477N/mm -fs)/(120×(0.9N/mm +(m/d ))),2) = 1.579
Allowable span to depth ratio; 0.9 × 26 × k1 = 36.942
Actual span to depth ratio; L / d = 31.818
PASS - Span to depth ratio is OK
Internal bay 2-3
Effective span; L = 6800 mm
6
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
7
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
8
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
PUNCHING SHEAR
Corner column A1
Design shear transferred to column; Vt = ((0.45 × Spanx) + ex) × ((0.45 × Spany) + ey) × Nult = 202 kN
Design effective shear transferred to column; Veff = 1.25 × Vt = 252 kN
2
Area of tension steel in x-direction; Asx_ten = Ascorner = 1340 mm /m
2
Area of tension steel in y-direction; Asy_ten = Ascorner = 1340 mm /m
Column perimeter; uc = lx1 + ly = 650 mm
Average effective depth of reinforcement; d = h – c - φp = 214 mm
9
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
2
Maximum allowable shear stress; vmax = min(0.8 × √(fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc × d) = 1.811 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 1292 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
2
As_ten = 1731 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) ×0.79×min(100×As_ten/(u×d),3) ×max(400/d,1) /1.25
2
vc = 0.707 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 0.911 N/mm
vc < v <= 1.6 × vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) × u × d / (0.95 × fyv) = 119 mm
Shear reinforcement at a perimeter of 2.25d - (482 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 1613 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
2
As_ten = 2161 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) ×0.79×min(100×As_ten/(u×d),3) ×max(400/d,1) /1.25
2
vc = 0.707 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 0.730 N/mm
vc < v <= 1.6 × vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) × u × d / (0.95 × fyv) = 16 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 1934 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
2
As_ten = 2592 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) ×0.79×min(100×As_ten/(u×d),3) ×max(400/d,1) /1.25
2
vc = 0.707 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 0.609 N/mm
v < vc no shear reinforcement required
Penultimate edge column A2
Design shear transferred to column; Vt = ((0.45 × Spanx) + ex) × (1.05 × Spany) × Nult = 453 kN
Design effective shear transferred to column; Veff = 1.4 × Vt = 634 kN
2
Area of tension steel in x-direction; Asx_ten = Asx_edge = 1148 mm /m
10
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
2
Area of tension steel in y-direction; Asy_ten = Asy1e = 2094 mm /m
Column perimeter; uc = (2 × lx1)+ ly = 900 mm
Average effective depth of reinforcement; d = h – c - φp = 214 mm
2
Maximum allowable shear stress; vmax = min(0.8 × √(fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc × d) = 3.292 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 2184 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
2
As_ten = 3588 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) ×0.79×min(100×As_ten/(u×d),3) ×max(400/d,1) /1.25
2
vc = 0.757 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 1.356 N/mm
1.6 × vc < v <= 2 × vc
2
Shear reinforcement required at perimeter; Asv_req = 5 × ((0.7 × v) - vc) × u × d / (0.95 × fyv) = 947 mm
Shear reinforcement at a perimeter of 2.25d - (482 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 2826 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
2
As_ten = 4628 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) ×0.79×min(100×As_ten/(u×d),3) ×max(400/d,1) /1.25
2
vc = 0.756 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 1.048 N/mm
vc < v <= 1.6 × vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) × u × d / (0.95 × fyv) = 372 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 3468 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
2
As_ten = 5669 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) ×0.79×min(100×As_ten/(u×d),3) ×max(400/d,1) /1.25
2
vc = 0.756 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 0.854 N/mm
vc < v <= 1.6 × vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) × u × d / (0.95 × fyv) = 154 mm
11
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
12
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 0.998 N/mm
vc < v <= 1.6 × vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) × u × d / (0.95 × fyv) = 365 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 3468 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
As_ten = 4734 mm2
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) ×0.79×min(100×As_ten/(u×d),3) ×max(400/d,1) /1.25
2
vc = 0.712 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 0.814 N/mm
vc < v <= 1.6 × vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) × u × d / (0.95 × fyv) = 159 mm
Shear reinforcement at a perimeter of 3.75d - (803 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 4110 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
2
As_ten = 5607 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) ×0.79×min(100×As_ten/(u×d),3) ×max(400/d,1) /1.25
2
vc = 0.711 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 0.686 N/mm
v < vc no shear reinforcement required
Penultimate edge column B1
Design shear transferred to column; Vt = (1.05 × Spanx) × ((0.45 × Spany) + ey) × Nult = 453 kN
Design effective shear transferred to column; Veff = 1.4 × Vt = 634 kN
2
Area of tension steel in x-direction; Asx_ten = Asx1e = 2513 mm /m
2
Area of tension steel in y-direction; Asy_ten = Asy_edge = 1148 mm /m
Column perimeter; uc = lx + (2 × ly1) = 900 mm
Average effective depth of reinforcement; d = h – c - φp = 214 mm
2
Maximum allowable shear stress; vmax = min(0.8 × √(fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc × d) = 3.292 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 2184 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
2
As_ten = 4066 mm
13
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
14
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
15
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
2
vc = 0.847 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 0.812 N/mm
v < vc no shear reinforcement required
Internal central column B3
Design shear transferred to column; Vt = (1.05 × Spanx) × Spany × Nult = 969 kN
Design effective shear transferred to column; Veff = 1.15 × Vt = 1114 kN
2
Area of tension steel in x-direction; Asx_ten = Asx1i = 2094 mm /m
2
Area of tension steel in y-direction; Asy_ten = Asye = 1570 mm /m
Column perimeter; uc = 2 × (lx + ly) = 1600 mm
Average effective depth of reinforcement; d = h – c - φp = 214 mm
2
Maximum allowable shear stress; vmax = min(0.8 × √(fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc × d) = 3.254 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 4168 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
2
As_ten = 7636 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) ×0.79×min(100×As_ten/(u×d),3) ×max(400/d,1) /1.25
2
vc = 0.785 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 1.249 N/mm
vc < v <= 1.6 × vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) × u × d / (0.95 × fyv) = 872 mm
Shear reinforcement at a perimeter of 2.25d - (482 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 5452 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
2
As_ten = 9988 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) ×0.79×min(100×As_ten/(u×d),3) ×max(400/d,1) /1.25
2
vc = 0.785 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 0.955 N/mm
vc < v <= 1.6 × vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) × u × d / (0.95 × fyv) = 418 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 6736 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
16
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
2
As_ten = 12340 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) ×0.79×min(100×As_ten/(u×d),3) ×max(400/d,1) /1.25
2
vc = 0.785 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 0.773 N/mm
v < vc no shear reinforcement required
Internal edge column C1
Design shear transferred to column; Vt = Spanx × ((0.45 × Spany) + ey) × Nult = 431 kN
Design effective shear transferred to column; Veff = 1.4 × Vt = 604 kN
2
Area of tension steel in x-direction; Asx_ten = Asxe = 1570 mm /m
2
Area of tension steel in y-direction; Asy_ten = Asy_edge = 1148 mm /m
Column perimeter; uc = lx + (2 × ly1) = 900 mm
(Library item: Flat slab shear map C1) Average effective depth of reinforcement; d = h – c - φp = 214 mm
2
Maximum allowable shear stress; vmax = min(0.8 × √(fcu), 5) = 4.733 N/mm
2
Design shear stress at column perimeter; v0 = Veff / (uc × d) = 3.135 N/mm
PASS - Maximum concrete shear stress not exceeded at column perimeter
Shear reinforcement at a perimeter of 1.50d - (321 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 2184 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
2
As_ten = 2989 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) ×0.79×min(100×As_ten/(u×d),3) ×max(400/d,1) /1.25
2
vc = 0.712 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 1.292 N/mm
1.6 × vc < v <= 2 × vc
2
Shear reinforcement required at perimeter; Asv_req = 5 × ((0.7 × v) - vc) × u × d / (0.95 × fyv) = 945 mm
Shear reinforcement at a perimeter of 2.25d - (482 mm)
Length of shear perimeter; u = uc + (2 × (kx × ky) × k × d) = 2826 mm
Area of tension steel at shear perimeter; As_ten = (ky × (px + (kx × k × d)) × Asy_ten) + (kx × (py + (ky × k × d)) ×
Asx_ten)
2
As_ten = 3862 mm
Design concrete shear stress;
1/3 1/3 1/4
vc=(min(fcu,40)/25) ×0.79×min(100×As_ten/(u×d),3) ×max(400/d,1) /1.25
2
vc = 0.712 N/mm
2
Nominal design shear stress at perimeter; v = Veff / (u × d) = 0.998 N/mm
vc < v <= 1.6 × vc
2
Shear reinforcement required at perimeter; Asv_req = (v - vc) × u × d / (0.95 × fyv) = 365 mm
Shear reinforcement at a perimeter of 3.00d - (642 mm)
17
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
18
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
19
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
CURTAILMENT OF REINFORCEMENT
Internal column
1/2 1/3
Radius of circular yield line; r = (lx × ly / π) × (1.05 × Spanx × 1.05 × Spany / (lx × ly)) = 1601
mm
Minimum curtailment length in x-direction; lint_x = Max(r + 12 × D, 0.25 × Spanx) = 1841 mm
Minimum curtailment length in y-direction; lint_y = Max(r + 12 × D, 0.25 × Spany) = 1841 mm
Corner column
1/2
Radius of yield line; r = (lx1 × ly / π) × ((0.45 × Spanx + ex) × (0.45 × Spany + ey)/ (lx1 ×
1/3
ly))
r = 863 mm
Minimum curtailment length in x-direction; lcorner_x = Max(r + 12 × D, 0.2 × Spanx) = 1440 mm
20
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
21
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
A B C
ex
Span x Span x
l x1
ey
1 n e f
l y1 s 0.2 x Spany
n r s r s
c
Span y
a b
q
p e f
0.5 x Spany
x x
2
ly
j j l
Span y
p g h
3
k k m
lx
0.5 x Spanx
0.2 x Spanx
When the effective span in the x direction, Lx, is greater than the effective span in the y direction, Ly, the
reinforcement in the outer layer is assumed to be that in the x direction otherwise it is assumed to be that in the y
direction.
22
Flat Slab Analysis & Design, In accordance with
Project: Job Ref.
BS8110:PART 1:1997
REINFORCEMENT KEY
2
a = 20 dia bars @ 150 centres - (2094 mm /m);
2
b = 16 dia bars @ 200 centres - (1005 mm /m)
2
c = 20 dia bars @ 200 centres - (1570 mm /m);
2
d = 16 dia bars @ 200 centres - (1005 mm /m)
2
e = 20 dia bars @ 125 centres - (2513 mm /m);
2
f = 20 dia bars @ 200 centres - (1570 mm /m)
2
g = 20 dia bars @ 150 centres - (2094 mm /m);
2
h = 20 dia bars @ 200 centres - (1570 mm /m)
2
j = 20 dia bars @ 150 centres - (2094 mm /m);
2
k = 20 dia bars @ 200 centres - (1570 mm /m)
2
l = 20 dia bars @ 150 centres - (2094 mm /m);
2
m = 20 dia bars @ 200 centres - (1570 mm /m)
2
n = 16 dia bars @ 150 centres - (1340 mm /m)
2
p = 16 dia bars @ 175 centres - (1148 mm /m);
2
q = 16 dia bars @ 150 centres - (1340 mm /m)
2
r = 16 dia bars @ 175 centres - (1148 mm /m);
2
s = 16 dia bars @ 200 centres - (1005 mm /m)
2
Distribution bars = 12 dia bars @ 300 centres - (377 mm /m)
23