model of PLC communication system with corresponding close to each other and give rise to frequency groups,
characteristics. which are approximated by narrow bands. Also
The transfer function and noise can thus be estimated characteristic is interference of a known frequency; it
from actual measurements or derived from theoretical appears in TV sets with the European system PAL, with a
analyses. The measurements on PLC channel are frequency of 15.625 kHz.
described in [2] and the theoretical models of power lines
are given in [5].
4. Narrow-band modems in measuring system
3. Types of interference on power lines For the requirements of narrow-band PLC
communication in various control and telemetric systems,
Background colour noise. This type of noise is PLC modems are manufactured in small series. Their
constantly present in the communication channel; its properties are usually rather similar. The Czech company
spectrum is uniform in the band under consideration. The ModemTec Ltd. manufactures modems of the MT23R
noise is of stochastic nature and has a comparatively low series. The modems are designed for data transfer over the
power spectral density (PSD). This type of noise is mostly low-voltage 230 V grid in industrial environment. The
generated by commutator motors. maximum data block length that can be transferred by
these modems at a time is 520 bytes (320 for the MT23R1
Asynchronous impulse interference. This type of model). MT23R modems can transfer any semi-duplex
interference is characterized by high and short voltage protocol; the protocol is not crucial to the response time
peaks of ca. 10 - 100μs in length, which can reach a and the maximum datagram length is 520 bytes.
voltage level of up to 2kV. This type of noise usually
occurs sporadically and is due to various switching
operations and contact switching on loads.
rate [bits/sec]
performed on the one hand in a household with standard
electrical appliances and, on the other hand, in the
industrial environment of a small factory. The subject of
long-term measurement was the rate of communication
and interference on the low-voltage 230V/50Hz grid.
Measuring the interference on power lines via evaluating
the spectral lines present can indicate problems with data
transfer. Another measurement carried out was therefore
the measurement of spectrum on the power line where data
communication was running.
To measure communication rate by means of PLC The same measurement was conducted in an industrial
modems the connection according to the block diagram in environment. The modems communicated over a distance
Fig. 4 was used. The first PC is connected to the PLC of 100m. This environment included machines with
modem by the RS232 serial line, the other PC is connected programmable logic control, stepping motors with control
via Ethernet to the Gnome 232 converter and then via the units, and several frequency converters. The average
RS232 serial line to the PLC modem. The Ethernet/RS232 communication rate obtained is approximately 6.5kbit/s,
converter was used to enable long-term monitoring of the as can be seen from Fig. 6.
transfer rate at regular intervals, using the “Interface
traffic indicator” program. This software monitored the
communication and every fifteen minutes it recorded the
rate [bits/sec]
ModemTec ModemTec
MT23+MT21 MT23+MT21
RS232
RS232
Gnome232
Ethernet
SW-
Interface
Traffic
Indicator Fig. 6 Transfer rate of PLC communication in industrial environment,
distance about 100m.
PLC communication
transfer of file
frequency [kHz]
have been documented and analyzed. It can be seen that Jiri Misurec Ing. (MSc). in 1985, (BUT),
under certain conditions this technology can be used for Ph.D. in 1991 (BUT). Associate Professor
remote data acquisition and control of power grid elements. in 2005 (FEEC BUT). His dissertation dealt
The main problem will evidently be the actual range of with accu-racy enhancement of voltage-to-
frequency converters. After completing his
data communication. It follows from other measurements
post-graduate studies he joined the Dept. of
that this communication is possible over a distance of Tele-communications as an Assistant
several hundred metres. In the measurements mentioned Professor. From 1997 to 2004 he was an
above, a distance of some 100-150m was therefore chosen employee at the firm "E.ON a.s. Brno", but
and thus the measurements were not too much affected by he has partici-pated in the research and teaching at FEEC BUT.
attenuation. As can be seen from works by other authors, Now he gives lectures in and leads the exercise for the subject
it will obviously be necessary to focus more on proposing “Analog technique " and give the lectures in the course "Digital
suitable mathematical models of power lines from the Signal Processing". His research interest is focused on the area of
viewpoint of data communication. It will then be possible analog technique, converters, especially on converters working
both in voltage and current mode. Now he is interested in data
to computer-simulate phenomena on power lines and thus
system for remote data collection, telemetering systems. This
improve the properties of this technology. should be used for comparison of newly developed applications.
In the latest he also cooperates with a number of companies on
implementation of fundamental research results into practise.
Acknowledgments
References
[1] HRASNICA,HAIDINE,LEHNERT. Broadband Powerline
Communications Network design. 2004. ISBN:0-470-
85741-2.
[2] PRASAD, K.V. Principles of Digital Communication
Systems and Computer Networks. Charles RIver Media,
2003. ISBN 1584503297.
[3] ModemTec. www.modemtec.cz [online]. 2008/04/10.
Available from WWW:
<http://www.modemtec.cz/moduly.php>.
[4] DOSTERT, K. Telecommunications over the Power
Distribution Grid- Possibilities and Limitations. Proc 1997
Internat. Symp. on Power Line Comms and its Applications
pp1-9, Saalbau, Essen, Germany April 2-4, 1997.
[5] PROAKIS, John G., MANOLAKIS, Dimitris G. Digital
Signal Processing : Principles, algotithms and applications.
Upper Saddle River, NJ07458 : Prentice-Hall Inc., 1996.
ISBN 0-13-394338-9.
[6] CENELEC [online] 2008/02/15. Available from WWW:
<http://www.cenelec.eu/Cenelec/Homepage.htm>.
[7] DALLY, WILLIAM J., POULTON, JOHN W. Digital
Systems Engineering. Cambridge : Cambrigge University
Press, 1998. ISBN 0-521-59292-5.
[8] OPERA CONSORTIUM. Open PLC Research Alliance :
OPERA [online]. 2008/04. Available from WWW:
<http://www.ist-opera.org/>.
[9] HELD, GILBERT. Understanding broadband over Power
Line. 6000 Broken Sound Parkway NW, Suite 300,
Auerbach Publications, 2006. ISBN 0-8493-9846-0.