3.2.3 Meter location


Caution: • Do not install the detector on the suction sides of pumps. This could
damage the liner (in particular PTFE liners).
• Verify that the pipeline is always filled on the measuring point, if not - a
correct or accurate measurement is not possible.
• Do not install the detector on the highest point of a pipeline system.
Gas accumulation may follow.
• Do not install the detector in downcomer pipes with free outlet.
• Do not install the detector on pipes with vibrations. If pipes are strongly
vibrating, make sure that detector and amplifier are separated
(separate version).

h > 2 x DN
M1000-15

M1000-16
N
xD
>2

N
xD
-5
>3

M1000-17
M1000-14

MID_M1000_BA_02_1509