You are on page 1of 74

Planning and design of PV power plants

SMA Solar Technology AG Be a solar expert


Disclaimer
The information contained in this presentation is subject to amendment, revision and updating. Certain statements contained in this
presentation may be statements of future expectations and other forward
forward-looking
looking statements that are based on the management
management’ss current
views and assumptions and involve known and unknown risks and uncertainties. Actual results, performance or events may differ materially
from those in such statements as a result of, among others, factors, changing business or other market conditions and the prospects for growth
anticipated by the management of the Company. These and other factors could adversely affect the outcome and financial effects of the
plans and events described herein. The Company does not undertake any obligation to update or revise any forward-looking statements,
whether as a result of new information,
information future events or otherwise.
otherwise You should not place undue reliance on forward-looking
forward looking statements which
speak only as of the date of this presentation.

All information contained herein has been carefully prepared. Nevertheless, we do not guarantee its accuracy or completeness and nothing
herein shall be construed to be a representation of such guarantee.

The information contained in this presentation is subject to amendment, revision and updating. Certain statements contained in this
presentation may be statements of future expectations and other forward-looking statements that are based on the management’s current
views and assumptions and involve known and unknown risks and uncertainties. Actual results, performance or events may differ materially
from those in such statements as a result of, among others, factors, changing business or other market conditions and the prospects for growth
anticipated
ti i t d by
b the
th managementt off theth Company.
C Th
These andd other
th factors
f t could ld adversely
d l affect
ff t the
th outcome
t and
d financial
fi i l effects
ff t off the
th
plans and events described herein. The Company does not undertake any obligation to update or revise any forward-looking statements,
whether as a result of new information, future events or otherwise. You should not place undue reliance on forward-looking statements which
speak only as of the date of this presentation.

This presentation
Thi t ti isi for
f information
i f ti purposes onlyl andd may nott be
b further
f th distributed
di t ib t d or passed
d on to
t any party
t which
whi h is
i nott the
th addressee
dd off
this presentation. No part of this presentation must be copied, reproduced or cited by the addressees hereof other than for the purpose for
which it has been provided to the addressee.

This document is not an offer of securities for sale in the United States of America. Securities may not be offered or sold in the
U it d States
United St t off America
A i absent
b t registration
i t ti or an exemption
ti f
from registration
i t ti under
d theth U.S.
U S Securities
S iti Act
A t off 1933 as
amended.
SMA Solar Technology AG
The SMA Solar Academy

> Transfer of knowledge


> Well-matched
comprehensive
seminar program
> Small, medium and large
scale PV plants

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 3


Organizational Matters

> Escape routes


> Meeting point in case of a fire alarm
> Toilets
>> Smoking area contact data
Solar Academy
> Please
> mute your+49
Phone: cell(0)561-9522-4884
phones or switch them off
> Badges
> e-mail:
il Solaracademy@SMA.de
S l d @SMA d
>> Cafeteria
Download areas:
> http://www.SMA.de/handout
p

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 4


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Seminar Contents

1 Introduction

2 Design of large scale PV plants with SMA components

3 Sunny Design 2.30


2 30

4 Option Code: SC, SSM, TCS, Communit

5 W kh
Workshop

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 5


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Large scale PV plant design

> Environment > Sunny Central


> PV generator/module > Transformer Compact Station
> Combiner Box > Grid
M
> Sunny String Monitor > Monitoring
M

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 6


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Example:

> Environment/cos φ: Germany/cos φ= 1 > Grid: 20 kV / 50 Hz


> PV generator/module: 0,910 MWp / MPV120M > Monitoring: DSL
> Sunny String Monitors: SSM XX-11 > NPR: 80-100%
> Sunny Central:l SC XXX CP
> Transformer Compact Station: TCS XXXX

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 7


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Data sheet: Module MPV 120-M -

Source: www.masdarpv.com
SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 8
1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Module MPV 120-M






Source: www.masdarpv.com
SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 9
1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Design Software

> Version 2.30


> Electric properties 
> Temperature coefficients 

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 10


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Design Software

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 11


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Design

> PV string length 


> PV generator size 
> Nominal Power Ratio 
> Power
P factor
f t 

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 12


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Design

> Maximum PV voltage VOC (-10 ºC)  M


> Maximum PV current IMPP (+70 ºC, 1000 W/m2)  M
> Minimum PV voltage VMPP (+70 ºC)  M

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 13


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Design

> Annual energy yield  M


> Specific energy yield  M
> Performance ratio  M
> Nominal
N i l power ratio
ti  M

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 14


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - Option Code

1. Maximum DC-Voltage
2. DC connection
3. DC fuses
4 Grounding
4. d
5. Insulation monitoring
6 Communication
6.
7. Fiber optic components
8. Language/Country
9. AC switch
10. String current monitoring
11. AC voltage
12. Cabinet layout

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 15


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - Maximum DC voltage

> Connecting solar modules (V MPP = 109 V) in series increases the voltage in string
> Strings may not exceed the permissible system voltage (VMAX = 1000 V) under the worst
conditions (low temperatures, high radiation, open circuit)
> Each of the strings
g connected to a Sunnyy Central must always
y have the same number of solar
modules connected in series

MPV120M MPV120M MPV120M

...

V OC String < V DC MAX Sunny Central V OC String < 1000 V


SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 16
1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - Maximum DC voltage

 M
SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 17
1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - DC connection

> PV module MPV 120M


> Thin-film technology
> Fuses in plus and isolating blades in minus

 M

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 18


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - DC fuses

> PV module MPV 120M


> Thin-film technology
> Fuses in plus and isolating blades in minus
> Fuse
F sizes:
i 125A/160A/200A/250A/315A/400A

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 19


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - DC fuses

> Maximum current of PV generator 1390.4 A


> Fuses in plus: 5/7/8 fuses are possible
> Possible fuse sizes: 400A/315A/250A
> Reduction
R d ti factor:
f t 00.7
7
> Isolating blades in minus

Maximum current of PV arrays 1390.4 A

Fuses 125 A 160 A 200 A 250 A 315 A 400 A

Reduction factor 0.7 0.7 0.7 0.7 0.7 0.7

I Fuse-max 87.5 A 112 A 140 A 175 A 220 A 280 A

N Inputs DC + 16 13 10 8 7 5

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 20


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - DC fuses

> 5/7/8 inputs with fuses are possible


> 5/7/8 Sunny String Monitor (SSM) are possible too
> Maximum permissible DC current of SSM must be considerate
> M i
Maximum i ibl DC currentt off SSM d
permissible d on ambient
depends bi t
temperature

Sunnyy String
g Monitor

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 21


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - DC fuses

SSM24-11

SSM16-11

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 22


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - DC fuses

SSM24-11

SC 760 CP-10:
8 x Fuse 250 A (I Fuse-max = 175 A) 
7 x Fuse 315 A (I Fuse-max = 220 A) 
5 x Fuse 400 A (I Fuse-max = 280 A) 

SSM16-11

Sunny String Monitor

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 23


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - DC fuses

SC 760 CP-10:
SSM24-11 8 x Fuse 250 A (I Fuse-max = 175 A) 
7 x Fuse 315 A (I Fuse-max = 220 A) 
5 x Fuse 400 A (I Fuse-max
Fuse max = 280 A) 

SSM16-11

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 24


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Option 1: Calculating with SSM 24-11 - DC fuses

> PV generator: 1264 strings


> Inverter: 1 x SC 760 CP-10
> SC 760 CP-10 fuses: 5 x DC + bar
> SC 760 CP
CP-10
10 ffuse size:
i 400A
> SC 760 CP-10 reduction factor: 0,7
> Sunnyy Stringg Monitor: 5 x SSM 24-11

Fuses SC 760 CP 125 A 160 A 200 A 250 A 315 A 400 A

Reduction factor 0.7 0.7 0.7 0.7 0.7 0.7

I Fuse-max 87.5 A 112 A 140 A 175 A 220 A 280 A

N Inputs 16 13 10 8 7 5

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 25


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Option 1: Calculating with SSM 24-11 - DC fuses

> 5 x SSM 24-11


> SSM 24-11 I DC max : 312 A (50 ºC)
> SSM 24-11 fuse sizes: 10A/12A/16A/20A
> SSM 24 11 reduction
24-11 d ti ffactor:
t 0 65 (50 ºC)
0.65
> IString = 1.10 A

Fuses SSM 24-11 10 A 12 A 16 A 20 A

Reduction factor 0.65 0.65 0.65 0.65

Max. I Fuse 6.5 A 7.8 A 10.4 A 13.0 A

Max. Strings Fuse 5 7 9 11

Max. Strings SSM24-11 120 168 216 264

Sunny String Monitor

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 26


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Option 1: Calculating with SSM 24-11 - DC fuses

> Fuse size 20 A


> Up to 11 strings per SSM input
> Up to 264 string per SSM
i necessary to
> It is t use a special
i l combiner
bi boxb with
ith 11 iinputs
t
> High cost of DC cabling

Fuses SSM 24-11 10 A 12 A 16 A 20 A

Reduction factor 0.65 0.65 0.65 0.65

Max. I Fuse 6.5 A 7.8 A 10.4 A 13.0 A

Max. Strings Fuse 5 7 9 11

Max. Strings SSM24-11 120 168 216 264

Sunny String Monitor

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 27


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Option 1: Calculating with SSM 24-11 - DC fuses

> 5 x SSM 24-11 > Special combiner box is necessary


> PV generator has 1264 strings > High cost
> Fuses can not be identical
> 4 x SSM 24
24-11
11 with
ith 20 A ffuse SC 760 CP
CP-10:
10:
5 x Fuse 400 A (I Fuse-max = 280 A) 
> 1 x SSM 24-11 with 16 A fuse
4 x SSM 24-11 
Fuses SSM -11 10 A 12 A 16 A 20 A 96 Fuses (20A) 

1 x SSM 24-11 120 168 216 264 96 Combiner box (11 strings) 

2 X SSM 24-11
24 240 336 432 528
1 x SSM 24-11 
3 X SSM 24-11 360 504 648 792 24 Fuses (16A) 
24 Combiner box (9 strings) 
4 X SSM 24-11 480 672 864 1056

5 x SSM 24-11 
5 X SSM 24-11 600 840 1080 1320
120 Combiner box (11/9 strings) 
120 Fuses (20/10 A) 
Customer combiner cox
1264 Fuses (5A) 
SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 28
1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Option 2: Calculating with SSM 16-11 - DC fuses

> PV generator: 1264 strings


> Inverter: 1 x SC 760 CP-10
> SC 760 CP-10 fuses: 7 x DC + bus
> SC 760 CP
CP-10
10 ffuse size:
i 315 A
> SC 760 CP-10 reduction factor: 0,7
> Sunnyy Stringg Monitor: 7 x SSM 16-11

Fuses SC 760 CP 125 A 160 A 200 A 250 A 315 A 400 A

Reduction factor 0.7 0.7 0.7 0.7 0.7 0.7

I Fuse-max 87.5 A 112 A 140 A 175 A 220 A 280 A

N Inputs 16 13 10 8 7 5

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 29


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Option 2: Calculating with SSM 16-11 - DC fuses

> 7 x SSM 16-11


> SSM 16-11 I DC max : 260 A (50 ºC)
> SSM 16-11 fuse sizes: 10A/12A/16A/20A/25A
> SSM 16 11 reduction
16-11 d ti ffactor:
t 0 65 (50 ºC)
0.65
> I String = 1.10 A

Fuses SSM 16-11 10 A 12 A 16 A 20 A 25 A

d
Reduction f
factor 0.65 0.65 0.65 0.65 0.65

I Fuse-max 6.5 A 7.8 A 10.4 A 13 A 16.25 A

g Fuse
Strings 5 7 9 11 14

Strings SSM16-11 80 112 144 176 224

Sunny String Monitor

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 30


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Option 2: Calculating with SSM 16-11 - DC fuses

> Fuse size 25 A


> Up to 14 strings per SSM input
> Up to 224 string per SSM
i possible
> It is ibl to
t use a special
i l combiner
bi boxb with
ith 14 iinputs
t
> It is possible to use the SMA Combiner Box with 12 inputs

Fuses SSM 16-11 10 A 12 A 16 A 20 A 25 A

d
Reduction f
factor 0.65 0.65 0.65 0.65 0.65

I Fuse-max 6.5 A 7.8 A 10.4 A 13 A 16.25 A

g Fuse
Strings 5 7 9 11 14

Strings SSM16-11 80 112 144 176 224

Sunny String Monitor

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 31


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Option 2: Calculating with SSM 16-11 - DC fuses

> Up to 1568 strings


> Special combiner box with 14 fuses
> High cost of DC cabling

Fuses SSM 16-11 10 A 12 A 16 A 20 A 25 A

1 x SSM 16-11 80 112 144 176 224

2 X SSM 16-11 160 224 288 352 448

3 X SSM 16-11 240 336 432 528 672

4 X SSM 16-11 320 448 576 704 896

5 X SSM 16-11 400 560 720 880 1120

6 X SSM 16-11 480 672 864 1056 1344

7 X SSM 16-11
16 11 520 784 1008 1232 1568
Sunny String Monitor

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 32


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Option 2: Calculating with SSM 16-11 - SMA Combiner Box

> Up to 24 DC fuses (12 plus/12 minus)


> Fuse sizes 5 A, 10 A, 12 A, 15 A, 20 A, 25 A
> Reduction factor 0.55
> Up
U tto 2 strings
ti per DC ffuses
> Equipped with a DC switch-disconnector
> Overvoltage
g protection
p

SMA Combiner Box

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 33


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Option 2: Calculating with SSM 16-11 - SMA Combiner Box

> Maximum allowable reverse current is 5 A


> Recommended circuit configuration is 5 strings x 6 modules per cluster
> There is no need for a serial fuse per string in the case of a 5 strings per cluster
> From
F 6 strings
ti onward,
d a serial
i l ffuse off 5 A per string
t i iis tto b
be used
d
> Bear in mind that the minus pole of PV generator must be grounded

+ I Cluster = 5,50 A

P = 120 Wp, V OC = 142,2 V, I SC = 1,34 A, I MPP = 1,10 A

6 6 6 6 6

V OC = 853,2 V I String = 1,10 A

1 1 1 1 1

_
SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 34
1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Option 2: Calculating with SSM 16-11 - SMA Combiner Box

> SMA Combiner Box reduces cost


> 12 strings per SMA Combiner Box
> 12 DC + fuses
> Fuse
F size
i 5A
> 1 string per fuse
> 192 strings
g per
p SSM 16-11

SMA Combiner Box

F
Fuses SSM 16-11
16 11 10 A 12 A 16 A 20 A 25 A 25 A

Reduction factor 0.65 0.65 0.65 0.65 0.65 0.65

I Fuse-max 6.5 A 7.8 A 10.4 A 13 A 16.25 A 13.20 A

Strings Fuse 5 7 9 11 14 12

Strings SSM16-11 80 112 144 176 224 192

SMA Combiner Box


SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 35
1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Option 2: Calculating with SSM 16-11 - DC fuses

> 7 x SSM 16-11 > 6 x SSM 16-11 with 25 A fuse


> 1264 strings > 1 x SSM 16-11 with 12 A fuse
> Fuses can not be identical
SC 760 CP-10:
SMA Combiner Box (7 strings) SMA Combiner Box (12 strings)
7 x Fuse 315 A (I Fuse-max = 220 A) 

Fuses SSM 16-11 10 A 12 A 16 A 20 A 25 A 25 A


6 x SSM 16-11 
1 x SSM 16-11 80 112 144 176 224 192
96 fuses (25 A) 

2 X SSM 16-11 160 224 288 352 448 384 96 combiner box (12 strings) 

3 X SSM 16-11 240 336 432 528 672 576


1 x SSM 16-11 
16 fuses (12 A) 
4 X SSM 16-11 320 448 576 704 896 768
16 combiner box ( 7 strings) 
5 X SSM 16-11 400 560 720 880 1120 960
7 x SSM 16-11
16 11 
6 X SSM 16-11 480 672 864 1056 1344 1152 112 combiner box (12/7 strings) 
112 fuses (25/12 A) 
7 X SSM 16-11 520 784 1008 1232 1568 1344
1264 fuses ((5 A)) 

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 36


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Option 2: Calculating with SSM 16-11 - SMA Combiner Box

> Optimal solution


> 7 x SSM 16-11
> 112 Combiner Box

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 37


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-11 - DC fuses

> 7 fuses per pole


> Fuse size: 315 A

 M

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 38


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - Grounding

> PV module MPV 120M


> Thin-film technology
> GFDI and minus grounding

 M

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 39


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - Grounding

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 40


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - Insolation monitoring

> With GFDI

 M

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 41


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - Communication

> Touch display

 M

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 42


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - Fiber optic components


Inverter 01 Inverter 02
SC 760 CP-10 SC 760 CP-10
COM-C
in control center/grid operation
Internet
1 500 m

5m

Inverter Inverter
SMA Service
900 m

5m

75 m

Inverter

Copper (100m max. length between 2 Fiber optics single mode


participants) (15 km max. length between 2 participants)
Fiber optics multi mode
(2km max. length between 2 participants)

 M

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 43


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - Language /Country of destination

> Germany

 M

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 44


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - AC switch

> With AC circuit breaker

 M

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 45


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - String current monitoring

> 7 x SSM 16-11


> 7 x 16 = 112 channels
Fiber optic or Ethernet (Cu)
> Max. 8 channels per SMU Splicebox
(optional)
> Max.
M 10 SMU´
SMU s per hub
h b
Fiber optic converter
> Max. 3 hubs per SC 760 CP-10
Switch Service
(E h
(Ethernet )
WebBox
RS485
Inverter
RS485
Sunny String
SCSMC
Monitor
SSM 1 Hub

SSM 2

SSM 3 SC xxx CP

RS485
SSM N
SCSMC: Sunny Central String Monitor Controller

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 46


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - String current monitoring

> 112 channels


> 14 SMUs
Fiber optic or Ethernet (Cu)
> 2 hubs Splicebox
(optional)
> Hub1:
H b1 48 channels
h l RS485 Fiber optic converter
> Hub 2: 64 channels 1 SSM 16-11 Hub 1

2 SSM 16-11 Switch Service


(E h
(Ethernet )
3 SSM 16-11 WebBox
RS485
Inverter
RS485
SCSMC
RS485
4 SSM 16-11 Hub 2

5 SSM 16-11

6 SSM 16-11 SC 760 CP-10

7 SSM 16-11

SCSMC: Sunny Central String Monitor Controller

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 47


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - String current monitoring

> 112 channels


> 14 SMUs
> 2 hubs
> Hub1:
H b1 48 channels
h l
> Hub 2: 64 channels

 M

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 48


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - AC voltage and cabinet layout

> 342 V
> Standard

 M
 M

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 49


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny String Monitor SSM 16-11 - Option Code

> Optimal solution


> 7 x SSM 16-11
> 112 Combiner Box

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 50


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny String Monitor SSM 16-11 - Option Code

SMA Combiner Box

PV strings

Sunnyy Central SC 760 CP-10

Sunny String Monitor SSM 16-11

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 51


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny String Monitor SSM 16-11 - Option Code

> 6 x SSM 16-11


> 96 x SMA Combiner Box
> 1152 strings

5A
1
6 X PVM 120M 25 A
1

12

SMA Combiner Box

Sunnyy Central ((315 A fuse))

16

Sunny String Monitor SSM 16-11

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 52


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny String Monitor SSM 16-11 - Option Code

> 1 x SSM 16-11


> 16 x SMA Combiner Box
> 112 strings

5A
1
6 X PVM 120M 25 A
1

SMA Combiner Box

Sunnyy Central ((315 A fuse))

16

Sunny String Monitor SSM 16-11

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 53


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny String Monitor SSM 16-11 - Option Code


X6

X6

X6

X6

X6

X6
Sunny String Monitor
SSM 16-11

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 54


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny String Monitor SSM 16-11 - Option Code

1. Cabinet
2. Device type
3. Version
4 String fuse
4. f
5. DC switch
6.
6 Connections per input
7. Connector
8. Cable glands with sealing area
9. DC output
10. Language

Sunny String Monitor SSM 16-11

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 55


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny String Monitor SSM 16-11 - Option Code




SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 56
1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny String Monitor SSM 16-11 - Option Code



SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 57


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

SMA Combiner Box - Option Code


X6

X6

X6

X6

X6

X6
SMA Combiner Box

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 58


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

SMA Combiner Box - Option Code



SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 59
1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

SMA Combiner Box - Option Code


SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 60


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - Communication Concept


Inverter 01 Inverter 02
SC 760 CP-10 SC 760 CP-10
COM-C
in control center/grid operation
Internet
1 500 m

5m

Inverter Inverter
SMA Service
900 m

5m

75 m

Inverter

Copper (100m max. length between 2 Fiber optics single mode


participants) (15 km max. length between 2 participants)
Fiber optics multi mode
(2km max. length between 2 participants)

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 61


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - Communication Concept


Inverter 01 Inverter 02
SC 760 CP-10 SC 760 CP-10
COM-C Communit
in control center/grid operation
Internet


1 500 m

5m

Inverter Inverter
SMA Service
900 m

5m

75 m

Inverter

Copper (100m max. length between 2 Fiber optics single mode


participants) (15 km max. length between 2 participants)
Fiber optics multi mode
(2km max. length between 2 participants)

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 62


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Sunny Central 760 CP-10 - Communication Concept


Inverter 01 Inverter 02
SC 760 CP-10 SC 760 CP-10

C
Communit
Internet
1 500 m

5m

Inverter Inverter
SMA Service
900 m

5m

75 m

Inverter

Copper (100m max. length between 2 Fiber optics single mode


participants) (15 km max. length between 2 participants)
Fiber optics multi mode
(2km max. length between 2 participants)

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 63


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Communit - Option Code


SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 64


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Communit - Option Code



SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 65


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Transformer Compact Station and SC 760 CP-10

> Transformerless inverter must not be used (e.g. Sunny Tripower)


> Sunny Centrals require always a medium voltage transformer

UPV-MPP UWR UGrid


G id

~
~
~
Sunny Central Medium voltage transformer

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 66


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Transformer Compact Station and 760 CP-10


SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 67


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

C
Communit
i

Transformer Compact Station and 760 CP-10


X6

X6

X6

2
3 x 342 V 3 x 20 kV

X6

TCS 1600 SC

X6
Inverter 01 TCS 1600 SC Inverter 02

X6

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 68


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Transformer Compact Station TCS 1600 SC - Option Code







SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 69


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Design of large scale PV-Plant Communit

X6

X6

X6

2
3 x 342 V 3 x 20 kV

X6

TCS 1600 SC

X6 Inverter 01 TCS 1600 SC Inverter 02

X6

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 70


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Workshop

> Environment/cos φ: Milan (Italy)/cos φ= 1 > Grid: 20 kV / 50 Hz


> PV generator/module: 1,9 MWp / E19 / 318 > Topology: Ring
> Sunny String Monitors: SSM XX-11 > Monitoring: DSL
S
> Sunny C t l
Central: SC XXX CP XT > NPR:
NPR 80 100%
80-100%
> Transformer Compact Station: TCS XXXX

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 71


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Design

1. PV module data sheet


2. PDF file Sunny Design 2.30
3. Sunny Central data sheet
4 SSM data
4. d t sheet
h t
5. Communit data sheet
6. TCS data sheet
7. Sunny Central option code
8. SSM option code
9. Communit option code
10. TCS option code

SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 72


1. Introduction | 2. Design | 3. Sunny Design | 4. Option Code | 5. Workshop

Allways up to date with the Sunny Newsletter

go.sma.de/news
g /
SMA Solar Technology AG P-P-PD-1-DE-en_WW-124010 73
Let‘s be realistic
and try the impossible!

SMA Solar Technology AG

You might also like