You are on page 1of 2

I.

The gross calorific value of the fuel

CVH= [4.18/100][8080 C% + 34500 (H%-O%/8)+ 2220S%]


35294.248 kJ/kg

CVL = CVH –mw*4.18*588.76


34341.8344984 kJ/kg

II. The minimum air/fuel ratio

(𝑘𝑔_(𝑠∪𝑏))/(𝑘𝑔_𝐹 ) (𝑘𝑔_𝑂2)/(𝑘𝑔_𝐹 )
Sub
�_(𝑶_𝟐,𝒕�)
C 0.88 2.346666667
�_2 ├ �/𝑭┤|_𝒕�
0.043 0.344
S 0.01 0.01
�_2 0.04 -0.04
�_2 0.007 �_(𝑵_𝟐,𝒕�)
Ash 0.02
∑ 1 2.660666667

III. If 25% excess air is supplied compute the percentage composition by volume of the dry flue gas
Compute the gas constant of the flue gases.

kgi/kgf=mi
Flue gases Mi ni=(mi/Mi) Xi=(ni/nt)
CO2 3.2266666667 44 0.073333333 0.142786785
H2O 0.387 18 0.0215 0.0418624892
SO2 0.02 64 0.0003125 0.0006084664
O2 0.6651666667 32 0.020786458 0.0404731576
N2 11.134311594 28 0.397653986 0.7742691018
∑ 0.513586277 1
Rg=(Ru/Mm) 0.276674413 kJ/kgoC
Cp,g
1.198922455 kJ/kgoC
�_(𝑶_𝟐,𝒕�) 2.6607 kgo2/kgf

├ �/𝑭┤|_𝒕�
11.568 kga/kgf

�_(𝑵_𝟐,𝒕�) 8.9074 kgN2/kgf

lume of the dry flue gases.

Xi Mi
6.2826185396
0.7535248062
0.0389418505
1.295141043
21.679534849
30.049761089