You are on page 1of 6

GUDAWALI STOP DAM

CHECKING STABILITY AT FOUNDATION LEVEL

(A) Water is at Afflux HFL 152.50 w1 w2 Bottom width


Taking moment @ A 2.3 4.2 6.50
S No Name L H Area Density V Force H Force LA M+ M-
Foundation
1 W1 1 2.3 4.00 9.20 2.4 22.080 5.35 118.13 R.L. 138.40
2 W2 0.5 4.2 4.00 8.40 2.4 20.160 2.8 56.45 Sill R.L. 143.00
3 W3 1 6.50 4.60 29.90 2.4 71.760 3.25 233.22 Top R.L. 147.00
4 U1 -0.5 6.50 14.10 -45.83 1 -45.825 4.3333 -198.58 HFL 152.50

5 U2 1 6.5 5.50 35.75 1 35.750 3.25 116.19 Afflux HFL 152.50

6 U3 0.5 4.2 4.00 8.40 1 8.400 1.4 11.76


7 Pw1 -1 5.50 8.60 -47.30 1 -47.30 3.95 -186.84
8 Pw2 -0.5 8.60 8.60 -36.98 1 -36.98 2.6333 -97.381
9 Pw3 1 5.50 8.60 47.30 1 47.30 3.95 186.84
10 Pw4 0.5 8.60 8.60 36.98 1 36.98 2.6333 97.38

45.83 112.33 0 819.96 -482.79


EV EH
x = EM/EV = 3.00 EM = 337.17
e = b/2-x = 0.5957 < b/6 ie 1.083

Factor of Safety against over turning = M+/-M- = 1.704 > 1.5 Hence Safe
Factor of safety against Sliding = EH 0.000 < 0.65 Hence Safe
EV
P = Ev/b(1 ± 6e/b)
Pmax = 27.986 2.7986 Kg/cm2 < 10 Kg/cm2
Pmin = 8.128 0.8128 Kg/cm2 < 1 Kg/cm2
Hence Safe
GUDAWALI STOP DAM
CHECKING STABILITY AT FOUNDATION LEVEL

(A) WATER IS AT AFFLUX HFL

14.80 6.5 152.50

152.50
152.5
5.50

U2
5.50 6.50

147.00
147.00

Pw1 w1 U3
4.00 8.60
Pw3
W2 143.00
8.60
w3
Pw2 Pw4
138.40 138.40
8.60 5.50 2.3 4.20 14.10
6.5 8.60
14.10

U1
Pma

14.10
GUDAWALI STOP DAM
CHECKING STABILITY AT FOUNDATION LEVEL

(B) Water is at F T L
w1 w2 Bottom width Foundation R.L. 143.20
2.3 4.2 6.5 Sill R.L. 143

Taking moment @ A Top R.L. 147


S No Name L H Density V Force H Force LA M+ M- HFL 152.5
Afflux HFL 152.5
1 W1 1 2.3 4.00 2.4 22.08 5.35 118.13

2 W2 0.5 4.2 4.00 2.4 20.16 2.80 56.45

3 W3 1 6.5 3.90 2.4 60.84 3.25 197.73


4 U1 -0.5 6.5 8.60 1 -27.95 4.33 -121.12
5 Pw1 -0.5 8.60 8.60 1 -36.98 2.63 -97.381

75.13 -36.98 18.37 372.31 -218.50


EV EH
EM = 153.81
x = EM/EV = 2.166
e = b/2-x = 0.93911 < b/6 1.083
P= Ev/b(1±6e/b)
Pmax = 22.23 t/m2 or 2.223 Kg/cm2 < 10
Pmin = 1.585 t/m2 or 0.159 Kg/cm2 <1

Hence Safe
GUDAWALI STOP DAM
CHECKING STABILITY AT FOUNDATION LEVEL

(A) WATER IS AT FTL

151.40

w1
w2
143 W2

8.20

Pw1
w3
143.20

8.20 5.00 1.50

6.5

U1
8.20
GUDAWALI STOP DAM
CHECKING STABILITY AT FOUNDATION LEVEL OF L/S & R/S WING WALL U/S & D/S

w1 W2/W3 Bottom Width


Taking moment @ A 0.6 5.40 6.00
S No Name L H Area Density V Force H Force LA M+ M-

1 W1 1 0.6 9.20 5.52 2.40 13.248 0.3 3.9744 Top R.L. 147.60
2 W2 0.5 5.4 9.20 24.84 2.40 59.616 2.400 143.078 U/S toe R.L. 138.40
3 W3 0.5 5.4 9.20 24.84 1.7 40.986 4.200 172.141 Foundation R.L. 138.40
4 U1 -0.5 6 9.20 -27.6 1 -27.600 4.00 -110.4 Density of Concrete 2.40

5 Pw1 -0.5 4.18 9.20 -19.23 1.65 -31.726 2.833 -89.8909 Density of Soil ( w ) 1.65

Density of Water 1.00


Cp 0.33
8.37 86.250 -31.726 319.194 -200.291
EV EH
EM = 118.90

x = EM/EV = 2.830
e = b/2-x = 0.170 < b/6 ie 1.000
Factor of Safety against overturning = M+/-M- = 1.94 > 1.5 Hence Safe

Factor of safety against Sliding = EH 0.35 < 0.65 Hence Safe


EV

P = Ev/b(1 ± 6e/b)
Pmax = 9.82 0.982 Kg/cm2 < 10 Kg/cm2
Pmin = 6.97 0.697 Kg/cm2 < 1 Kg/cm2
Hence Safe
GUDAWALI STOP DAM
CHECKING STABILITY AT FOUNDATION LEVEL OF L/S & R/S WING WALL U/S & D/S

147.60

W3

W1
9.20

W2

Pw1

138.40
Cpwh = 4.68 5.40
6.00 0.6

9.20 Pu1

You might also like